Impact of cradle immobilization on setup reproducibility during external beam radiation therapy for lung cancer.

PURPOSE: To compare the setup accuracy during fractionated radiation therapy for two patient groups with lung cancer treated with and without an immobilization cradle. METHODS: Three hundred ninety-seven port films from 30 patients immobilized in the Alpha Cradle were compared with 329 port films from 30 patients who were not immobilized with the cradle. All patients were treated with curative intent for nonmetastatic lung cancer. The frequency of physician-requested isocenter shifts were compared in the two groups using a two-tailed chi-square test. Initial port films taken on the first day of treatment, routine films taken usually weekly during radiation therapy, and requested films taken after a requested shift were considered separately. The immobilization device consisted of a custom-made foam cradle that extended from above the head to the knees. Patients were generally treated with their arms above their heads, and treatment setup marks in the immobilized patients were placed on both the patients' skin and the immobilization cradle. For the noncradle patients, setup marks were placed only on the patients' skin. RESULTS: For the routine films, the frequency of physician-requested isocenter shifts was lower in immobilized patients than in the nonimmobilized group (p = 0.139). Most of this reduction was seen on oblique fields (p = 0.038). No benefits were seen among initial or requested films. The two groups were well balanced with regard to stage, age, field size, and total dose. CONCLUSIONS: The use of aggressive immobilization improves the setup reproducibility in patients receiving external beam radiation therapy for lung cancer, especially during treatment with oblique fields. This improvement in treatment accuracy might improve the therapeutic ratio.

Humans↗

Quantification of radiation-induced regional lung injury with perfusion imaging.

PURPOSE: To better understand the dose and time dependence of radiation therapy (RT)-induced regional lung dysfunction as assessed by changes in regional lung perfusion. METHODS AND MATERIALS: Patients who were to receive RT for tumors in and around the thorax, wherein portions of healthy lung would be incidentally irradiated, were prospectively studied. Regional function was assessed pre- and post-RT with single photon emission computed tomography (SPECT) lung perfusion scans, obtained following the intravenous administration of approximately 4 mCi of technetium-99m macroaggregated albumin. Pre-RT computed tomography (CT) scans were used to calculate the three-dimensional (3D) dose distribution, reflecting tissue density inhomogeneity corrections. Each SPECT scan was correlated with the pre-RT CT scan, and the 3D dose distribution. Changes in regional lung perfusion were correlated with regional RT dose, at various time intervals following radiation. RESULTS: The data from 20 patients (7 breast cancer, 5 lymphoma, 1 esophagus, 1 sarcoma, and 6 lung cancer) have been analyzed. Patients with gross intrathoracic lung cancers causing obstruction of regional pulmonary arteries were not included. For most patients, there is a statistically significant dose-dependent reduction in regional blood flow at all time points following radiation. While a time dependence is suggested in the high dose range, the limited amount of data prevents meaningful statistical evaluation. CONCLUSIONS: Radiation therapy-induced regional lung dysfunction occurs in a dose-dependent manner and develops within 3-6 months following radiation. In contrast to classical "sigmoid" dose-response curves, described mainly for changes following whole lung irradiation, these data suggest a more gradual relationship between regional dysfunction and RT dose. Retraction of irradiated lung with secondary movement of unirradiated lung into the "3D-defined irradiated volume" may have introduced inaccuracies into this analysis. Additional studies are currently underway to assess this possibility and better refine this dose-response curve. Studies are underway to determine if changes in assessments of whole lung function, such as pulmonary function tests, can be predicted by summing the regional changes observed.

Dose-Response Relationship, Radiation↗

Impact of setup variability on incidental lung irradiation during tangential breast treatment.

PURPOSE: This study aimed to determine the variability in treatment setup during a 5-week course of tangential breast treatment for patients immobilized in a customized hemibody cradle, to assess the relationship between the height of the lung shadow on the tangential port film and the percentage of lung volume irradiated, and to estimate the impact of setup variabilities on irradiated lung volume. METHODS: One hundred seventy-two port films were reviewed from 20 patients who received tangential beam treatment for breast cancer. The height of the lung shadow at the central axis (CLD) on each port film was compared to the corresponding simulator film as an assessment of setup variability. A three-dimensional dose calculation was performed, and the percentage of total lung volume within the field was correlated with the CLD. The three-dimensional dose calculation was repeated for selected patients with the location of the treatment beams modified to reflect typical setup variations. RESULTS: The CLD measured on the port films was within 3 mm of that prescribed on the simulator film in 43% (74 of 172) of the port films. The variation was 3-5 mm in 26%, 5-10 mm in 25%, and >10 mm in 6%. The height of the lung shadow correlated with the percentage of lung volume included in the radiation field (r2 = 0.6). Typical variations in treatment setup resulted in < or = 5% fluctuation in the absolute volume of ipsilateral lung irradiated. CONCLUSION: The current immobilization system used in our clinic provides a clinically acceptable reproducibility of patient setup. The height of the lung shadow is reasonably well correlated with the percentage of irradiated lung volume. During a typical 5-week course of radiotherapy, the ipsilateral irradiated lung volume fluctuates <5%.

Breast Neoplasms↗

Changes in plasma transforming growth factor beta during radiotherapy and the risk of symptomatic radiation-induced pneumonitis.

PURPOSE: To determine whether changes in the plasma Transforming Growth Factor beta1 (TGF beta1) concentration during radiotherapy could identify patients at risk for developing symptomatic radiation pneumonitis. METHODS AND MATERIALS: Thirty-six patients who received radiation therapy with curative intent for lung cancer (n = 31), Hodgkin's disease (n = 4), or thymoma (n = 1) were evaluated prospectively. All patients had serial plasma TGF beta1 measurements obtained before, during, and after treatment. Plasma TGF beta1 was quantified using an enzyme-linked immunosorbent assay. Pneumonitis was defined clinically. Plasma TGF beta1 levels were considered to have normalized if the following occurred: the last on-treatment TGF beta1 level was both <7.5 ng/ml and lower than the pretreatment level. RESULTS: Thirteen of these 36 patients developed pneumonitis. Significant changes in plasma TGF beta1 levels during treatment were seen only in the subset of patients whose TGF beta1 levels were >7.5 ng/ml at baseline (n = 22). Failure of plasma TGF beta1 to normalize by the end of treatment, as defined above, much more accurately identified patients at risk for symptomatic pneumonitis if their baseline TGF beta1 was >7.5 ng/ml than if it was <7.5 ng/ml. CONCLUSIONS: Changes in plasma TGF beta1 levels during radiotherapy appears to be a useful means by which to identify patients at risk for the development of symptomatic radiation pneumonitis, particularly in the subset of patients whose pretreatment TGF beta1 levels are >7.5 ng/ml.

Biomarkers↗

A phase III randomized prospective trial of external beam radiotherapy, mitomycin C, carmustine, and 6-mercaptopurine for the treatment of adults with anaplastic glioma of the brain. CNS Cancer Consortium.

PURPOSE: This study was designed to evaluate strategies to overcome the resistance of anaplastic gliomas of the brain to external beam radiotherapy (ERT) plus carmustine (BCNU). Patients were > or = 15 years of age, had a histologic diagnosis of malignant glioma, and a Karnofsky performance status (KPS) > or = 60%. METHODS AND MATERIALS: In Randomization 1, patients were assigned to receive either ERT alone (61.2 Gy) or ERT plus mitomycin C (Mito, IV 12.5 mg/m(2)) during the first and fourth week of ERT. After this treatment, patients went on to Randomization 2, where they were assigned to receive either BCNU (i.v. 200 mg/m(2)) given at 6-week intervals or 6-mercaptopurine (6- MP, 750 mg/m(2) IV daily for 3 days every six weeks), with BCNU given on the third day of the 6-MP treatment. Three hundred twenty-seven patients underwent Randomization 1. One hundred sixty-four received ERT alone, and 163 received ERT + Mito [average 52.7 years; 63% male; 69% glioblastoma multiforme (GBM); 66% had a resection; 56% KPS > or = 90%]. Step-wise analysis of survival from Randomization 1 or 2 indicates that survival was significantly diminished by: (a) age > or = 45 years (b) KPS < 90%; (c) GBM/gliosarcoma histology; (d) stereotactic biopsy as opposed to open biopsy or resection. Median survival from Randomization 1 in both arms (ERT + Mito) was 10.8 months. Median survival from Randomization 2 was 9.3 months for BCNU/6MP vs. 11.4 months for the BCNU group (p = 0.35). Carmustine/6-MP showed a possible survival benefit for histologies other than GBM/GS. Two hundred and thirty-three patients underwent Randomization 2. The proportion of patients in the ERT group who terminated study prior to Randomization 2 was significantly less in the ERT group than in the ERT + Mito group (20 vs. 37%, p < 0.001). CONCLUSIONS: (a) The addition of Mito to ERT had no impact on survival; (b) patients treated with ERT + Mito were at greater risk of terminating therapy prior to Randomization 2; (c) there was not a significant survival benefit to the addition of 6-MP to BCNU.

Adult↗

Conformal radiation therapy with fixed shaped coplanar or noncoplanar radiation beam bouquets: a possible alternative to radiosurgery.

PURPOSE: Three-dimensional (3D) geometric conformation of the therapeutic dose volume to the shape of a target tissue volume is the motivation for both conformal radiotherapy and radiosurgery. Although noncoplanar arcs have a clear physical and geometric advantage over fixed fields for small spherical targets, those advantages are reduced for large or irregularly shaped targets where static fields can be individually shaped. We have developed a system that allows efficient and flexible design and reliable delivery of customized "bouquets" of fixed nonopposed coplanar or noncoplanar shaped fields, resulting in highly uniform dose distributions. This report describes our initial experience using beam bouquets to treat intracranial lesions. METHODS AND MATERIALS: Patients with primary (11) or metastatic (4) intracranial lesions with a maximum diameter less than approximately 6 cm, most of whom candidates for single-fraction radiosurgery, were treated with beam bouquets of four to eight nonopposed coplanar or noncoplanar beams. Doses ranged from 16-20 Gy in four fractions for recurrent lesions (8) to 45 to 68 Gy in 25 to 34 fractions for primary lesions (7). The patients were immobilized with custom foam head supports and face masks attached to a fixed base plate. Planning computed tomography scans were acquired, from which the physician developed the custom beam bouquet using 3D treatment-planning tools. The bouquet was designed based primarily on geometric concerns. The bouquet was subsequently modified to add wedge filters chosen by vector analysis of dose gradients to achieve uniform dose over the volume of beam crossfire. At the time of treatment, the isocenter was placed using the instructions provided by the treatment-planning system and pretreatment orthogonal port films were compared to digitally reconstructed radiographs (DRR) to assure proper isocenter placement. For several situations, the 3D dose distributions resulting from alternative coplanar and noncoplanar plans were compared. RESULTS: Each patient was treated without incident. Daily pretreatment port films showed excellent reproducibility of isocenter placement in 87% of setups. With short follow-up (0-12 months), two patients with recurrent glioblastoma experienced clinical deterioration 2 to 4 weeks following treatment. One had increased edema on scans and responded to steroids. Six patients clinically improved following radiation therapy. Review of alternative treatment plans reveals that the relative utility of coplanar vs. noncoplanar beams is likely dependent on the location of the lesion. Noncoplanar beam bouquets are likely preferable to coplanar beams when the target is located in the central regions of the head. Coplanar beams are likely adequate, and possibly preferable, for peripherally located targets. CONCLUSION: The biological advantages of fractionation and the physical advantages of radiosurgery are exploited with this approach. The use of multiple nonopposed coplanar or noncoplanar conformal wedged fields provides a uniform dose to the target and acceptable dose gradient at the target edge. This technique may prove to be an alternative to arc-based radiosurgery in some settings and has the potential advantages that fractionation should improve the therapeutic ratio, and each beam can be individually shaped to conform to irregularly shaped targets. Additional studies are underway to improve this system and better define its utility.

Adult↗

A customized head and neck support system.

PURPOSE: To describe a customized head and neck immobilization system for patients receiving radiotherapy including a head support that conforms to the posterior contour of the head and neck. METHODS: The system includes a customized headrest to support the posterior head and neck. This is fixed to a thermoplastic face mask that molds to the anterior head/face contours. The shape of these customized head and neck supports were compared to "standard" supports. RESULTS: This system is comfortable for the patients and appears to be effective in reproducing the setup of the treatment. CONCLUSIONS: The variability in the size and shape of the customized posterior supports exceeded that of "standard" headrests. It is our clinical impression that the customized supports improve reproducibility and are now a standard part of our immobilization system. The quantitative analysis of the customized headrests and some commonly used "standard" headrests suggests that the customized supports are better able to address variabilities in patient shape.

Equipment Design↗

The effectiveness of immobilization during prostate irradiation.

PURPOSE: To evaluate the effect of a hemibody foam cradle on the reproducibility of patient setup during external beam radiation treatment of prostate cancer. METHODS AND MATERIALS: Between January 1992 and April 1993, 74 patients received external beam radiation treatment to the prostate +/- nodes, generally with a four-field box technique. Forty-four of the 74 patients had a custom-made hemibody foam cast used in an attempt to improve setup accuracy. A review of the routine weekly port films was performed following the completion of therapy to determine the reproducibility of patient setup in all 74 patients. The physician's request of an isocenter shift was used as an indicator of reproducibility. Neither the treating technologists nor the physicians knew at the time the films were taken that the port films would be reviewed for setup reproducibility at a later date. The results were compared between the patients treated with (44) and without (30) an immobilization device. RESULTS: In the 44 immobilized patients, 213 routine checks of the isocenter were performed during the 7-week course of radiation therapy. In 17.4% of these instances (37 out of 213), an isocenter shift was requested. This rate is compared to 23.1% (30 out of 130) in the 30 patients who did not have the immobilization device (p < 0.2). There was a statistically significant reduction in isocenter shifts requested in the anterior to posterior direction in the patients who were immobilized, 5.1% (9 out of 175) vs. 12.6% (13 out of 103) (p < 0.05, two tailed chi-square test). There was no significant improvement in the reproducibility of isocenter placement in the cephalad to caudal or right to left directions. CONCLUSIONS: This custom-made hemibody foam cradle appears to improve the reproducibility of patient setup during the 7-week course of fractionated external beam irradiation for patients with adenocarcinoma of the prostate. This type of immobilization device is now routinely used in our clinic and is recommended for all patients receiving pelvic radiotherapy. These devices are likely to be particularly useful when contemplating dose escalation to minimize the volume of bladder and rectum included in the treatment fields.

Adenocarcinoma↗

Changes in plasma TGF beta levels during pulmonary radiotherapy as a predictor of the risk of developing radiation pneumonitis.

PURPOSE: To determine whether plasma transforming growth factor-beta (TGF-beta) levels measured before and during radical radiotherapy for lung cancer could be used to predict patients at risk for the development of radiation pneumonitis. METHODS AND MATERIALS: The first eight patients with lung cancer (nonsmall cell: seven, small cell: one) enrolled in a prospective study designed to evaluate physiological and molecular biologic correlates of radiation induced normal tissue injury are described. The study began in June 1991. All patients were treated with radiotherapy with curative intent. Plasma transforming growth factor-beta levels were obtained before, weekly during, and at each follow-up after treatment. Pretreatment pulmonary function tests and single photon emission computed tomography scans were obtained to assess baseline lung function and were repeated at follow-up visits. Dose-volume histogram analyses were performed to determine the volume of lung which received > or = 30 Gy. Patients were assessed at each follow-up visit for signs and symptoms of pneumonitis. RESULTS: Five patients developed signs and/or symptoms of pulmonary injury consistent with pneumonitis and three patients did not. In all three patients not developing pneumonitis, plasma TGF-beta levels normalized by the end of radiotherapy. In contrast, four out of five patients who suffered pneumonitis had persistently elevated plasma TGF-beta levels by the end of therapy. This finding appeared to be independent of the volume of irradiated lung. CONCLUSIONS: These results suggest that plasma TGF-beta levels during treatment may be useful to determine which patients are at high risk of developing symptomatic pneumonitis following thoracic radiotherapy. This finding may have implications when planning additional therapy (either chemotherapy or radiotherapy) which may have potentially adverse consequences on the lung.

Adult↗

A simple device to position large/flaccid breasts during tangential breast irradiation.

PURPOSE: It is technically difficult to irradiate large pendulous or flaccid breasts with tangential photon fields because they often lie very high or lateral on the chestwall. We, therefore, designed a device to reposition the breast on the chestwall to facilitate treatment. METHODS AND MATERIALS: A device to aid in repositioning the breast on the chestwall has been designed. The device consists of a reinforced polyvinylchloride tube formed into a ring that is placed around the breast. A strap around the patient's chest holds the ring in place. The breast tissue is manually moved to the desired position on the chestwall, whereafter the strap is tightened to maintain the position. Treatment setup marks are placed on the skin peripheral to the breast and on the immobilization mold. RESULTS: Twelve patients with large/flaccid breasts were successfully treated with this device. The technical and physician staff find the reproducibility and acute treatment reactions to be acceptable. Anatomically, the use of this device reduces the volume of lung tissue otherwise included in the tangential fields in patients where the breast lies far lateral. In patients where the breast lies too far cephalad on the chestwall for tangential fields to clear the arm, repositioning of the breast with this device makes tangential fields possible. CONCLUSION: This repositioning appliance aids in the radiation treatment of patients with large or flaccid breasts and, in some instances, renders otherwise nontreatable patients treatable with radiation therapy.

Breast↗

Correlation of mid-sternum and mid-spine positions in 82 patients irradiated for breast cancer.

The validity of designing anterior internal mammary node (IMN) radiation therapy fields based on vertebral body landmarks was tested by reviewing computer tomography (CT) images in 82 patients treated for breast cancer. The horizontal distance between the geometric center of the sternum and the vertebral body was 0-5, 6-10 and > 10 mm in approximately 30%, 25%, and 45% of patients, respectively. This suggests that using the projection of the vertebral bodies to design an anterior internal mammary node field is frequently inaccurate and may lead to inadequate coverage of these lymph nodes.

Breast Neoplasms↗

The utility of SPECT lung perfusion scans in minimizing and assessing the physiologic consequences of thoracic irradiation.

PURPOSE: Three-dimensional single photon emission computed tomography lung perfusion scans (SPECT) provide a unique quantitative 3-dimensional map of the distribution of functioning pulmonary vascular/alveolar subunits, information not provided by other imaging modalities. This report describes our initial experience utilizing these scans to assist in the design of radiation treatment beams and to assess changes in regional lung function following irradiation. METHODS AND MATERIALS: Patients were immobilized and scanned in the treatment position with appropriate fiducial markers. Four millicuries of technetium 99M microaggregated albumin were injected and SPECT images of the lung were generated. Pre-treatment SPECT images were used to help design radiation beams to minimize irradiation of functioning lung. Pre- and post-treatment scans were compared to assess changes in regional function. These changes in function were then correlated with the regional radiation dose. RESULTS: Pre-radiotherapy SPECT scans were obtained in 18 patients (11 with lung cancer). Marked variations in regional function were frequently noted. In patients with primary lung tumors, these variations were not necessarily immediately adjacent to the tumor volume. In general, patients with poor pulmonary function pre-treatment, in whom one would like to spare as much normal lung as possible, had the most non-uniform distribution throughout the lung of functioning vascular/alveolar subunits. In these cases, pre-treatment scans were most useful in designing radiation portals to minimize irradiation of functioning lung. SPECT scans were also used to detect changes in regional lung function secondary to radiotherapy in four patients. With doses in excess of 40 Gy, reductions in regional function were noted 1-6 months following completion of radiotherapy. These reductions were not necessarily accompanied by reductions in conventional pulmonary function tests, which are assessments of whole lung function and may not reflect regional lung injury if the volume affected is small. CONCLUSIONS: SPECT lung scans provide an excellent means of assessing regional lung function, superior to that obtainable with planar images. The functional data provided by the SPECT images is useful in designing "optimal" radiation treatment beams and in assessing the effect of radiotherapy on regional lung functions. Efforts are continuing in our laboratory to develop a dose response curve for regional lung damage using the tools of SPECT scanning and 3-dimensional dose calculations.

Aged↗

125I embedded in an orbital prosthesis for retreatment of recurrent retinoblastoma.

The application of radiation therapy in the retreatment of unilateral recurrent retinoblastoma presents a very difficult dilemma in which consideration must be given to preservation of vision in the remaining eye while tumoricidal doses of irradiation are delivered. A technique is described in which a methylmetraculate eye sphere carrying a single Iodine-125 seed was used to deliver local irradiation to the orbital tissues in a patient with multiple episodes of recurrent retinoblastoma. The tissue dose at 2 mm depth was 2630 cGy while the dose to the retina of the remaining eye and to the optic chiasm was negligible.

Brachytherapy↗

Design of a plastic minicolpostat applicator with shields.

A plastic intracavitary applicator system for the treatment of cancer of the uterine cervix is described. This applicator has a minicolpostat and a mechanism for affixing the tandem to the colpostats. Traditional afterloading refers only to the radioactive source. Both the source and the ovoid shield are afterloaded together in this applicator in contrast to traditional afterloading systems which afterload the source alone. A potential advantage of our applicator system is that it allows high quality CT localization because the sources and shields can be removed and the applicator is made of plastic. The advantages and disadvantages of this variation to the Fletcher system as well as other aspects of applicator design are discussed. An experimentally verified dose calculation method for shielded sources is applied to the design problems associated with this applicator. The dose distribution calculated for a source-shield configuration of the plastic applicator is compared to that obtained with a commercial Fletcher-Suit-Delclos (FSD) applicator. Significant shielding improvements can be achieved for the smallest diameter ovoid, that is, in the minicolpostat. The plastic minicolpostat dose distributions are similar to those produced by the conventional larger diameter colpostats. In particular, the colpostat shielding for rectum and bladder, which is reduced in the metal applicator's minicolpostat configuration, is maintained for the plastic minicolpostat. Further, it is shown that, if desired, relative to the FSD minicolpostat, the mucosa dose can be reduced by a suitable change of the minicolpostat source position.

Brachytherapy↗

Transperineal templates for brachytherapy treatment of pelvic malignancies--a comparison of standard and customized templates.

A technique is described for the design and construction of customized templates for transperineal implants and interstitial hyperthermia of pelvic malignancies. The design of the template and the distribution of the transperineal Iridium-192 seed ribbons are based on prior optimization of the dose distribution. The target volume is defined by means of pelvic examination and pertinent radiographic studies including a CT. The pelvic CT study is obtained with a plastic obturator in the rectum or the vagina. The obturator is used as a reference structure for aligning the target contour from each image plane to form a composite 2-dimensional contour of maximum tumor extent in a plane perpendicular to the obturator. Dose distributions are calculated to determine the placement of the Iridium-192 seed ribbons in the template. Laparoscopic guidance is used for actual placement of brachytherapy source needles together with a rectal or vaginal obturator to stabilize the template and to assure that the needle placement conforms with the planned geometry. Dose distributions for 10 consecutive patients calculated for customized templates as well as for five commercially available standard templates show that the customized templates are superior to standard templates in that the planned dose distribution matches the configuration of the target volume and is more uniform than with standard templates.

Adult↗

High-dose areas are unintentionally created as a result of gap shifts when the prescribed dose in the two adjacent areas are different.

A large number of methods have been described for matching adjacent fields to prevent over- or underdosage at a field junction. Most authors recommend that the location of field junctions be shifted to different locations during the course of the treatment in an effort to "smear out" any dose inhomogeneity regardless of which field matching technique is used. This report focuses on the considerable variation in dose that can occur when the dose in the two adjacent treatment areas is different at the time of the gap shift. In a typical cranio-spinal treatment we found a 16% dose increase over the prescribed central axis dose.

Brain Neoplasms↗

First place 1989 Alpha Cradle Award winner. Positioning and immobilization device for patients receiving radiation therapy for carcinoma of the breast.

Careful treatment planning and dose calculation, combined with effective positioning and immobilization, may improve the probability of tumor control. Modern radiation therapy equipment has had a significant impact on the accuracy of dose calculation and delivery. However, the problems of patient repositioning and immobilization, which may represent the area of the greatest variance in precise treatment delivery, still need much improvement. On this premise, many site specific repositioning and immobilizing devices have been developed in our institution for radiation therapy. Alpha Cradles have been used for positioning of patients undergoing irradiation for carcinoma of the breast at our institution for several years but did not provide adequate support for the arm. A modification of an Alpha Cradle was developed specifically for breast treatments and is described in this report. The modification, which is easily made, consists of a mold which conforms tightly to the arm and allows minimal variation in repositioning of the arm. A handle, built into the device, offers the patient a comfortable resting place for the hand and also fixes the orientation of the hand during the treatments. This device offers a very comfortable support for the elevated arm and greatly improves the accuracy of repositioning the patient.

Awards and Prizes↗