Search PubMed⌕ Search

Biomedical subjects

G Breithardt

Publications and source records attributed to G Breithardt.

At least 271 records · Page 15Linked to original sources

Implantable cardioverter defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy, long QT syndrome, or no structural heart disease.

Recent technical developments in implantable cardioverter defibrillator (ICD) systems and reduced operative mortality and morbidity rates associated with ICD implantation have expanded the indications for ICD treatment of ventricular tachyarrhythmias. This review summarizes data regarding ICD therapy in patients with arrhythmogenic right ventricular cardiomyopathy, long QT syndrome, and idiopathic ventricular fibrillation and presents preliminary concepts for identification of patients who will benefit more from ICD therapy than from pharmacologic and other nonpharmacologic approaches. Recent studies suggest that ICD therapy may improve long-term prognosis by reliably terminating recurrences of life-threatening arrhythmias. Appropriate ICD therapies during mean follow-up periods of 12 to 36 months occurred in 30% of patients with idiopathic ventricular fibrillation to 50% of patients with arrhythmogenic right ventricular cardiomyopathy and long QT syndrome. At present no strict recommendations can be given for ICD implantation in these patients. However, at least in cardiac arrest survivors in whom the clinical arrhythmia is not reproducibly inducible during electrophysiologic study, ICD therapy appears to be superior to other treatment options with regard to long-term survival and thus should be considered as a first-line treatment. We are hopeful that continued study of long-term follow-up with and without ICD treatment and improved risk stratification will lead to better criteria for selection of treatment options.

Adult↗

Detection of regional left ventricular asynchrony in obstructive hypertrophic cardiomyopathy by magnetic resonance imaging.

Cine magnetic resonance imaging was used to analyze global and regional left ventricular function in seven patients with obstructive hypertrophic cardiomyopathy (HC) and 10 normal subjects. In patients with HC a 38% higher left ventricular mass index (106.4 +/- 20.2 gm/m2 vs 77.0 +/- 16.1 gm/m2, p < 0.005) associated with a lower end-diastolic volume index (44.9 +/- 8.9 ml/m2 vs 58.3 +/- 9.0 ml/m2, p < 0.005) resulted in an 85% higher mass-to-volume ratio (2.4 +/- 0.52 vs 1.3 +/- 0.57, p < 0.0005). Stroke volume did not differ significantly, whereas ejection fraction was higher (80.4% +/- 6.5% vs 65.4% +/- 7.2%, p < 0.0005) in patients with HC. Although early diastolic filling fraction was smaller in patients with HC (61.0% +/- 22.8% vs 68.4% +/- 14.6%), the difference did not reach significance because of substantial variability. In patients with HC (in contrast to normal subjects) the time to maximal wall thickening was shorter (p < 0.025) in the hypertrophied basal region of the ventricle (223 +/- 42 msec) than in the apical region (267 +/- 35 msec), reflecting asynchrony between these regions. Additionally, in patients with HC the standard deviation of the time to maximal wall thickening in the basal region was significantly higher when compared with that of normal subjects (40.0 +/- 24 msec vs 16.9 +/- 17 msec, p < 0.0005), reflecting asynchrony even within one region. Thus magnetic resonance imaging can detect regional left ventricular asynchrony, an important cause of impaired diastolic function, in patients with HC and normal global systolic function.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Single-incision implantation of cardioverter defibrillators using nonthoracotomy lead systems.

This study describes the placement of a newly designed implantable cardioverter defibrillator in a subpectoral device pocket using the incision for venous access in 16 patients undergoing implantation of an implantable cardioverter defibrillator with a nonthoracotomy lead system. The endocardial lead system consisted of a right atrial/superior vena cava defibrillation spring electrode and a right ventricular bipolar sensing/defibrillation electrode, inserted by cephalic venotomy or by puncturing of the subclavian vein. As a result of intraoperative testing using biphasic shocks the defibrillation threshold (DFT) had to be less than 24 J, otherwise an additional subcutaneous patch electrode was placed in the lateral chest wall near the cardiac apex through another incision. All patients received a nonthoracotomy lead system in combination with a subpectoral device placement. In 11 of 16 patients the endocardial leads alone were sufficient (DFT, 13.4 +/- 7.0 J), 5 of 16 patients (31%) required an additional subcutaneous patch electrode to achieve proper device function (DFT, 14.6 +/- 9.0 J). The operation lasted 93 +/- 20 minutes. This was a significant (p < 0.05) lower time consumption than standard nonthoracotomy approach combined with abdominal device placement (120 +/- 50 minutes). There were no postoperative complications. During follow-up period (average, 4 months), none of the patients reported major local symptoms, especially no device migration occurred. This approach, in contrast to an abdominal device placement, avoids another incision and subcutaneous tunneling of leads. In 11 of 16 patients defibrillator implantation by a single incision in the deltoideopectoral groove was possible.

Aged↗

Nonthoracotomy defibrillator implantation: a single-center experience with 200 patients.

Nonthoracotomy leads for defibrillator implantation and biphasic shocking devices are under investigation. Implantation success and mortality and morbidity of the procedure determine the operative course. Lead-associated complications, late infection, and freedom of sudden cardiac death characterize the follow-up period with respect to the implanted device. From October 1989 to March 1993 in 200 patients, 205 (including five infections caused by reimplantations) transvenous or transvenous-subcutaneous lead systems were tested. Mean ejection fraction was 0.40 +/- 0.16. In 62.5% (125/200) coronary artery disease and in 19% (38/200) cardiomyopathy was the underlying disease (59 patients with prior cardiac operations). Leads were implanted with defibrillation thresholds less than 25 J in 195 patients, whereas 10 patients received intrathoracal patches. Since biphasic shocks became available, no nonthoracotomy lead system has failed in the last 115 consecutive patients. Perioperative mortality in the nonthoracotomy group was 1% (2/195). In 6.2% (12/193) of the surviving patients, perioperative complications occurred. Major problems were bleeding from the device or patch pocket (n = 6) and early infection (n = 2). During the follow-up of 20 +/- 10 months, lead-associated complications (dislocation, lead fracture, insulation defect, loss of sensing) occurred in 9 patients and in 5 patients late infection appeared. Within the follow-up period no patient died suddenly, and 134 patients received therapeutic interventions by the device. Defibrillator implantation using nonthoracotomy leads, especially combined with biphasic shocking devices, is applicable in almost every patient. During the operative course and follow-up, the defibrillator-associated morbidity and mortality is at the same level as or lower than when using patch lead systems.

Adolescent↗

Characterization of atherosclerosis in a patient with familial high-density lipoprotein deficiency.

We describe the cardiovascular state of a 60-year-old homozygous patient with familial HDL deficiency (Tangier disease). The patient was examined by coronary angiography and intravascular ultrasound because of chest pain at rest and on exertion. We found a normal left ventricular function, moderately diffuse coronary sclerosis without stenosis and no critical stenosis of peripheral arteries. Intravascular ultrasound revealed the three layer appearance of arterial intima, media and adventitia with normal thickness. No calcified plaques or intimal hyperplasia could be detected apart from a single, discrete atherosclerotic lesion in one iliac artery segment. Concentric non-occlusive atherosclerotic lesions which are readily detectable with intravascular ultrasound were not found. The lack of severe atherosclerosis was remarkable insofar as massive foam cell formation and the virtually complete absence of circulating HDL is characteristic of Tangier disease and has been previously demonstrated in this patient. Our findings suggest that HDL deficiency and foam cell formation in Tangier disease are not necessarily associated with accelerated development of atherosclerosis.

Adult↗

Validation of intravascular ultrasound in arteriosclerotic peripheral vessels.

In this in vitro-study, we validated intravascular ultrasound for the detection of irregular luminal contours, intraarterial structures, intimal thickening in peripheral arteriosclerotic human vessel segments and we compared sonographic criteria to the composition of arteriosclerotic lesions. Sixty-nine post-mortem segments of human peripheral arteries (6 patients) were fixed in formalin, examined with intravascular ultrasound and morphologically evaluated. Specificity, sensitivity, both positive and negative predictive value and accuracy of intravascular ultrasound for the detection of irregular luminal contours, intra-arterial structures and intimal thickening were determined for each of four quadrants. Ultrasonic features (echogeneity, homogeneity, shadowing of echoes) were also compared to the composition of lesions. Intravascular ultrasound detected regular (normal) luminal contours with a high specificity of 96.5%, a sensitivity of 65.0% and an accuracy of 88.4%. Intra-arterial structures were detected with a sensitivity of 88.6%, a specificity of 97.8% and an accuracy of 96.4%. Arteriosclerotic lesions could be localized with a sensitivity of 86.1%, a specificity of 99.1% and an accuracy of 86.9%. Intimal thickening was detectable with a sensitivity of 85.9%, a specificity of 87.8% and an accuracy of 86.2%. Meanwhile, fibrous, atheromatous and combined lesions without calcification did not show shadowing of echoes. The majority of fibrous or atheromatous lesions presented with homogeneous echoes showing hypo-, hyper- and normal density echoes. Using a 20-MHz transducer, homogeneity and echogeneity of echo patterns cannot accurately predict the different components of combined arteriosclerotic lesions.

Aorta, Abdominal↗

[Significance of intravascular ultrasound in arteriosclerotic calcified intima plaques: in vitro comparison of 20 and 12.5 MHz transducers].

The aim of this in vitro study was to analyze the diagnostic performance of intravascular ultrasound (IVUS) in vessel wall calcifications and to compare the accuracy of mechanical 12.5 and 20 MHz transducers. Fourty-three sections of 10 vessels with signs of arteriosclerotic disease on pathologic examination were examined. Slices 500 microns thick were obtained and examined radiographically at 9 fold magnification. In each section, identical segments were defined, amounting to a total of 344 segments. The IVUS sections were analyzed by 3 experienced readers. For statistical evaluation ROC analysis was performed using magnification radiography as a reference. An area under the curve (AUC) of 0.79 was obtained for the 12.5 transducer and of 0.83 for the 20 MHz transducer. Additionally, sensitivity, specificity, and accuracy were determined. Sensitivity depended on the morphology, size, and density of the calcified lesions. We therefore conclude that the sensitivity of intravascular ultrasound concerning calcified arteriosclerotic plaques is limited and that there is no significant (p < 0.01) difference between mechanical 20 and 12.5 MHz transducers in examining iliac arteries.

Angiography↗

Clinical significance and management of ventricular arrhythmias in heart failure.

Ventricular arrhythmias are a frequent finding in patients with heart failure, and heart failure is a major underlying condition which is correlated to sudden death. Therefore, both sudden death and death from progression of heart failure strongly overlap. Besides long-term ECG recording, newer diagnostic techniques have been developed. The prognostic significance of the signal-averaged ECG in patients with advanced left ventricular dysfunction in the presence of coronary artery disease has been demonstrated; however, in patients with dilated cardiomyopathy, signal-averaging for detection of late potentials has not yet been clearly established as a useful diagnostic tool. Furthermore, heart period variability has been shown to correlate to overall mortality but not to a specific mechanism. Finally, programmed ventricular stimulation, though useful in patients with left ventricular dysfunction and/or heart failure in the setting of coronary artery disease, is of questionable significance in patients with dilated cardiomyopathy. With increasing degrees of left ventricular dysfunction, the efficacy of antiarrhythmic drugs decreases. On the other hand, with increasing degrees of heart failure, antiarrhythmic drugs demonstrate a greater negative inotropic effect, more frequent proarrhythmic effects, and more frequent bradyarrhythmias. Currently, several ongoing amiodarone trials are assessing different approaches of antiarrhythmic treatment in patients with heart failure.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

In vitro correlation of intravascular ultrasound and direct magnification radiography for calcified arterial lesions.

RATIONALE AND OBJECTIVES: Intravascular ultrasound (IVUS) is an adjunct to contrast angiography that gives additional information concerning the morphology of the vascular wall. The authors examined the accuracy of intravascular ultrasound (IVUS) in the evaluation of calcified lesions within the abdominal aorta and the iliac artery. METHODS: Forty-nine human specimens (iliac artery, 26; abdominal aorta, 23) were examined using a 20-MHz 6.0-F ultrasound catheter, followed by magnification radiography of the same specimens using a newly developed microfocus x-ray tube. Magnification radiographs and ultrasound images were divided into identical sectors to analyze the morphology of calcified arteriosclerotic lesions. RESULTS: A total of 644 sectors was analyzed. Sensitivity of intravascular sonography was 70%, specificity 53%. Sensitivity strongly depended on the morphology of the calcified lesions. CONCLUSION: The detection of calcified arteriosclerotic lesions by means of IVUS revealed a sensitivity of 70% in an in vitro study using human specimens. However, the specificity of IVUS was only 53%, which is basically a random chance occurrence.

Aorta, Abdominal↗

Efficacy of ajmaline and propafenone in patients with accessory pathways: a prospective randomized study.

In a prospective randomized study, we assessed the electrophysiologic effects and the efficacy of ajmaline versus propafenone in patients with accessory pathways (APs). During initiated atrioventricular (AV) reentrant tachycardia or atrial fibrillation (AF), ajmaline (1 mg/kg as bolus followed by infusion of 15 micrograms/kg/min) or propafenone (2 mg/kg, followed by infusion of 30 micrograms/kg/min.) were randomly administered intravenously (i.v.) in 40 patients with APs. AV reentrant tachycardia terminated in 15 of 16 patients (94%) on ajmaline and in 12 of 15 patients (80%, NS) on propafenone. AF ceased in 4 of 4 patients receiving ajmaline and in 3 of 5 patients receiving propafenone (n.s.). During continuous infusion of drugs, AV reentrant tachycardia became noninducible in 10 (50%) patients receiving ajmaline, as compared with 6 (32%) receiving propafenone (NS). Both drugs significantly prolonged the anterograde and retrograde effective refractory periods (ERPs) of the AP. There were no significant differences in changes in electrophysiologic parameters between the two drugs. Ajmaline and propafenone are highly effective and safe in terminating and preventing reinitiation of AV reentrant tachycardia or AF in patients with APs. Both drugs significantly prolonged the anterograde and retrograde ERPs of the APs.

Accessory Nerve↗

Dispersion of ventricular refractoriness in experimental myocardial infarction: effect of sotalol.

UNLABELLED: Dispersion of refractoriness may contribute to the propensity for reentrant arrhythmias. This study was performed to assess the effect of sotalol on the dispersion of refractoriness in experimental myocardial infarction. In 9 mongrel dogs, 14 days after induction of myocardial infarction by an occlusion reperfusion technique, programmed ventricular stimulation and epicardial mapping were performed before and during (3 mg/kg + 0.5 mg/kg per hour) sotalol administration. To assess the spatial distribution of refractoriness, ventricular fibrillation (VF) intervals were analyzed. The rationale for this method is that, during VF, when multiple reentrant wavelets are present, cells are excited as soon as they recover from previous activation. The coefficient of variation (standard deviation x 100) served as an index of spatial distribution of refractoriness. RESULTS: VF was induced before sotalol in 7 dogs and in 5 of 7 during sotalol administration. The mean value of the index VF intervals decreased from 19.8 +/- 2.3 at baseline to 15.8 +/- 2.6 during sotalol (P = 0.011), indicating a more homogeneous distribution of refractoriness. Thus, the antiarrhythmic effects of sotalol may be mediated by its action on the dispersion of refractoriness.

Animals↗

Transvenous-subcutaneous defibrillation leads: effect of transvenous electrode polarity on defibrillation threshold.

INTRODUCTION: The defibrillation threshold (DFT) of a transvenous-subcutaneous electrode configuration is sometimes unacceptably high. To obtain a DFT with a sufficient safety margin, the defibrillation field can be modified by repositioning the electrodes or more easily by a change of electrode polarity. In a prospective randomized cross-over study, the effect of transvenous electrode polarity on DFT was evaluated. METHODS AND RESULTS: In 21 patients receiving transvenous-subcutaneous defibrillation leads, the DFT was determined intraoperatively for two electrode configurations. Two monophasic defibrillation pulses were delivered in sequential mode between either the right ventricular (RV) electrode as common cathode and the superior vena cava (SVC) and subcutaneous electrodes as anodes (configuration I) or the SVC electrode as common cathode and the RV and subcutaneous electrodes as anodes (configuration II). In each patient, both electrode configurations were used alternately with declining energies (25, 15, 10, 5, 2 J) until failure of defibrillation occurred. The DFT did not differ between both configurations (18.3 +/- 8.2 J vs 18.9 +/- 8.9 J; P = 0.72). Eleven patients had the same DFT with both electrode configurations, 5 patients a lower DFT with the RV electrode as cathode, and 5 patients a lower DFT with the SVC as cathode. Four patients had a sufficiently low DFT (< or = 25 J) with only 1 of the 2 configurations. CONCLUSION: A change of electrode polarity of transvenous-subcutaneous defibrillation electrodes may result in effective defibrillation if the first electrode polarity tested fails to defibrillate. In general, neither the RV electrode nor the SVC electrode is superior if used as a common cathode in combination with a subcutaneous anodal chest patch.

Adult↗

Radiofrequency catheter ablation of idiopathic left ventricular tachycardia: further evidence for microeentry as the underlying mechanism.

INTRODUCTION: Idiopathic left ventricular tachycardia with a QRS pattern of right bundle branch block and left-axis deviation constitutes a rare but electrophysiologically distinct arrhythmia entity. The underlying mechanism of this tachycardia, however, is still a matter of controversy. This report describes findings in a 42-year-old man who underwent successful radiofrequency catheter ablation of idiopathic left ventricular tachycardia. METHODS AND RESULTS: On electrophysiologic study, the tachycardia was reproducibly induced and terminated with double ventricular extrastimuli. Intravenous verapamil terminated the tachycardia whereas adenosine did not. Detailed left ventricular catheter mapping during sinus rhythm revealed a fragmented delayed potential at the mid-apical region of the inferior site near the posterior fascicle of the left bundle branch. At the same site, continuous electrical activity throughout the entire cardiac cycle was recorded during ventricular tachycardia. Repeated spontaneous termination of this continuous electrical activity in late diastole was followed immediately by termination of the tachycardia. Single application of radiofrequency current for 20 seconds at this site completely abolished inducibility of the tachycardia. After catheter ablation, at the identical site of preablation recording of the fractionated potential during sinus rhythm, no fragmented delayed activity could be recorded. There was no complication from the ablation procedure. CONCLUSION: The preablation recordings of fragmented delayed potentials during sinus rhythm and continuous diastolic electrical activity during tachycardia, together with ablation characteristics and previously reported electrophysiologic properties of this arrhythmia, may further support microreentry as the underlying mechanism in idiopathic left ventricular tachycardia.

Adult↗

Recurrence and late block of accessory pathway conduction following radiofrequency catheter ablation.

INTRODUCTION: Many issues regarding the recurrence of accessory pathway conduction and the long-term outcome of late block of accessory pathway conduction are still unknown or controversial. METHODS AND RESULTS: Data from 217 patients who underwent an initially successful radiofrequency ablation of accessory pathways and 7 patients with late block of accessory pathway conduction following an initially unsuccessful ablation were analyzed. During a mean follow-up of 19 +/- 11 months, accessory pathway conduction resumed in 21 (10%) of 217 patients following an initially successful ablation and in 6 (86%) of 7 patients with late block of accessory pathway conduction (P < 0.01). After initially successful ablations, the recurrence rates of accessory pathway conduction at 1, 3, and 6 months were 5.9%, 7.4%, and 11.3%, respectively. A late electrophysiologic study at 6 months uncovered recurrence in only 1 of 124 asymptomatic patients, but failed to detect the late recurrence in 2 patients in whom the accessory pathway conduction resumed after more than 6 months. Multivariate analysis revealed that independent predictors for recurrence of accessory pathway conduction were concealed accessory pathway, presence of transient effect of radiofrequency pulse, and more than 5 pulses required for initial cure. Accessory pathway location, length of the tip electrode of the ablation catheter, and repeat radiofrequency pulses ("safety pulses") after effective pulses did not predict resumption of accessory pathway conduction. CONCLUSIONS: After initially successful ablation, the recurrence rates of accessory pathway conduction at 1, 3, and 6 months were 5.9%, 7.4%, and 11.3%, respectively. Late electrophysiologic testing had little prognostic value in asymptomatic patients following successful ablation. Application of "safety pulses" did not prevent recurrence. Late block of accessory pathway conduction did not predict long-term efficacy.

Adolescent↗

A prospective randomized cross-over comparison of mono- and biphasic defibrillation using nonthoracotomy lead configurations in humans.

INTRODUCTION: For current implantable defibrillators, the nonthoracotomy approach to implantation fails in a substantial number of patients. In a prospective randomized cross-over study the defibrillation efficacy of a standard monophasic and a new biphasic waveform was compared for different lead configurations. METHODS AND RESULTS: Intraoperatively, in 79 patients receiving nonthoracotomy defibrillation leads, the defibrillation threshold was determined in the initial lead configuration for the mono- and biphasic waveform. In each patient, both waveforms were used alternately with declining energies (20, 15, 10, 5 J) until failure of defibrillation occurred. Three different initial lead configurations were tested in different, consecutive, nonrandomized patients using a bipolar endocardial defibrillation lead alone (A; n = 36) or in combination with a subcutaneous defibrillation patch (B; n = 24) or array (C; n = 19) lead. The lowest successful defibrillation energy with the biphasic waveform was less than, equal to, or higher than with the monophasic waveform in 64%, 28%, and 8% of patients, respectively, and on average significantly lower with the biphasic waveform for all three lead configurations (A: 11.3 +/- 4.4 J vs 14.5 +/- 4.5 J; B: 9.7 +/- 4.7 J vs 15.1 +/- 4.5 J; C: 7.9 +/- 4.5 J vs 12.4 +/- 4.9 J). Defibrillation efficacy at 20 J was significantly improved by the biphasic waveform (91% vs 76%). CONCLUSION: In combination with nonthoracotomy defibrillation leads, the biphasic waveform of a new implantable cardioverter defibrillator showed superior defibrillation efficacy in comparison to the standard monophasic waveform. Defibrillation thresholds were improved for lead systems with and without a subcutaneous patch or array lead.

Adult↗

Aortic valve replacement with cryopreserved pulmonary allograft.

Experimental as well as clinical data support the finding of using the pulmonary valve as a systemic semilunar valve. From January 1990 to December 1992, 89 patients received pulmonary cryopreserved allografts as aortic valve replacement. Sixteen subjects suffering from native or prosthetic valve endocarditis were included. Age ranged from 10 to 74 years. Sixty-five patients received isolated aortic valve replacement and 24 patients required additional surgical measures, such as coronary artery bypass graft, mitral valve reconstruction, replacement of the ascending aorta, supravalvular patch aortoplasty, ventricular septal defect closure, or myectomy. All operations were performed with normothermic bypass and cold cardioplegic arrest. Follow-up is maintained by visits to the outpatient clinic and echocardiographic assessment of the valve status every 3 months during the first year and every 6 months thereafter. There were four early and three late deaths. Four valves had to be removed: one intraoperatively and three 2, 4, and 24 months postoperatively. Echocardiographic assessment proved that gradients across the valve were low or absent. The majority of patients showed trivial or no aortic regurgitation during follow-up. No thromboembolic events have been observed and no new endocarditis occurred. Thus, event-free survival at 3 years is 87%. The results with pulmonary allografts have shown to be comparable to aortic allografts. Even in patients with acute native or prosthetic valve endocarditis, the use of cryopreserved pulmonary allografts has shown no adverse effects. We continue to implant cryopreserved pulmonary allografts in the aortic position. The long-term function of the valve, however, must be established, making continued evaluation of postoperative patients mandatory.

Adolescent↗