Search PubMed⌕ Search

Biomedical subjects

G Breithardt

Publications and source records attributed to G Breithardt.

At least 217 records · Page 12Linked to original sources

Multiresolution decomposition of the signal-averaged ECG using the mallat approach for prediction of arrhythmic events after myocardial infarction.

The aim of this study was to analyze the ability of the multiresolution decomposition of the signal-averaged electrocardiogram (ECG) to discriminate between patients who develop life-threatening ventricular arrhythmias after myocardial infarction and those who do not and to compare the predictive values of this approach with those obtained from the analysis of ventricular late potentials in the time domain. Signal-averaged ECGs of 769 prospectively included patients were analyzed. A total of 42 arrhythmic events occurred during the follow-up period. For numerical calculations of wavelet analysis, the total and relative energies of the QRS complex were obtained in seven frequency bands. The combination of the relative energy in the frequency bands 7.8-15.6 Hz and 62.5-125 Hz enhanced statistical performance as compared with the time-domain parameters (positive predictive accuracy, 11.3 vs 8.2%). Combining wavelet transform and time-domain parameters enhanced the predictive values even more (positive predictive accuracy, 14.3%) compared with applying each method alone.

Adult↗

The use of a Perma-Flow graft for coronary artery bypass surgery.

We report on our first clinical use of a Perma-Flow graft for coronary artery bypass surgery (CABG). It may well be that repeated successful use of this graft will offer a chance for revascularization to patients who might otherwise have been denied for lack of appropriate vessels.

Aged↗

Heart rate variability in time domain after acute myocardial infarction.

These results suggest that analysis of heart rate variability recorded even very early after acute myocardial infarction (1 to 2 days after onset of pain) is feasible in clinical routine and strongly related to subsequent arrhythmic events and cardiac mortality. Decreased HRV is considered not only a marker of impaired vagal activity of the heart but complete autonomic impairment, strongly associated with the degree of myocardial damage. HRV represents the integrated response of the cardiovascular system to a variety of different influences: the plasma level of catecholamines, the baroreflex activation and the direct sympathetic and vagal activity. The HRV profile is dynamic-HRV reduction caused by myocardial damage changes over time presenting a progressive increase up to normality over a 2-month follow-up. The observed early differences between anterior and inferior myocardial infarction disappear later in the healing phase. However, group analysis results of different HRV indices are stabile over time and highly reproducible, but presenting large individual variations. HRV parameters which are adjusted to heart rate (e. g. CV) seemed to be more stabile. The role of HRV analysis in risk stratification of patients after myocardial infarction is strongly related to the actual model of the genesis of ventricular arrhythmias. Multiple experimental and clinical studies described the development of life threatening ventricular arrhythmias as a multifactorial event which can not be described adequately using just one risk parameter for stratification. The arrhythmogenic substrate representing the underlying inhomogeneity of electrical behaviour of adjacent myocardial areas might be detectable by the analysis of ventricular late potentials or frequency disturbances from the signal averaged ECG. The autonomic modulation of this substrate is represented by an altered heart rate variability. Possible trigger factors to initiate arrhythmias in a modulated arrhythmogenic substrate like ventricular premature beats or transient myocardial ischemia can be detected by conventional arrhythmia and ST segment analysis from Holter tapes. The optimized combination of these non-invasive risk predictors together with well known evident clinical risk parameters, like left ventricular ejection fraction, may lead to a valid set of screening parameters for individual risk estimation after myocardial infarction.

Autonomic Nervous System↗

Coronary compliance in patients following orthotopic heart transplantation. An intravascular ultrasound study.

BACKGROUND: The aim of this study was to investigate coronary compliance in patients early and 71.8 weeks after orthotopic heart transplantation. METHODS: Thirty patients (mean age 51.4 years, women n = 6) underwent coronary angiography early after orthotopic heart transplantation (mean interval 11.6 +/- 5.5 weeks), by which time 12 recipients had already been treated for episodes of rejection. A total of 153 different coronary segments were investigated using a mechanical 30 MHz intravascular ultrasound system. In all segments, the intimal index and the circumferential extension of the vessel wall, which had a three-layered appearance, were assessed. Systolic-diastolic changes in area, and pressure with respect to vessel wall area, were used to study normalized compliance. All measurements were repeated in a subgroup of 13 patients 71.8 +/- 10.7 weeks after transplantation. RESULTS: At the first investigation, the mean intimal index of all estimated cross-sectional areas was 0.07 +/- 0.10. The mean circumferential extension of the 'three-layered' coronary vessel wall was 74 degrees +/- 101 degrees. No correlation could be found between normalized compliance and the intimal index (r = -0.322, P < 0.001) or between normalized compliance and the circumferential extension of the three-layered vessel wall (r = -0.362, P < 0.001). Donor age did not correlate with normalized compliance either (r = -0.515, P = 0.004). In 12 patients with proven rejection periods before the first investigation, normalized compliance was significantly lower (1.76 +/- 0.81 mmHg-1) than in those without rejection (2.95 +/- 1.22 mmHg-1, P = 0.005). Both the intimal index and the circumferential extension of the three-layered architecture of the vessel wall were significantly higher in recipients with rejection periods. A comparison of the subgroup of 13 recipients between first and second investigation showed that the intimal index increased slightly from 0.03 +/- 0.03 to 0.09 +/- 0.13 (ns) 71.8 weeks after transplantation, but that normalized compliance did not differ significantly between the first and the follow-up investigation. CONCLUSIONS: Early after orthotopic heart transplantation, normalized compliance does not correlate with donor age or the extent of atherosclerotic vessel alterations identifiable by intravascular ultrasound. Early rejection periods are associated with reduced coronary arterial compliance. Using intravascular ultrasound, this adverse functional effect on arterial compliance can be observed together with an increase in the intimal index.

Adult↗

Temperature-controlled radiofrequency catheter ablation of manifest accessory pathways.

OBJECTIVES: The primary objectives of this study were to assess the feasibility of temperature-controlled radiofrequency catheter ablation of left and right sided manifest accessory pathways in patients with Wolff-Parkinson-White syndrome and to gain more insights into biophysical aspects of temperature-controlled catheter ablation in humans. BACKGROUND: The electrode-tissue interface temperature and other biophysical parameters are among important variables determining the efficacy and safety of radiofrequency ablation of accessory pathways. Experimental studies have shown that radiofrequency-induced tissue necrosis can be accurately predicted by monitoring of catheter tip temperature. METHODS: 38 consecutive patients (14 f, 24 m; aged 42 +/- 12 years) with anterograde conducting accessory pathways (left sided: n = 22; right sided: n = 16) underwent temperature-controlled radiofrequency ablation (HAT 200S, Dr Osypka, Germany). The electrode temperature was monitored via a thermistor embedded into a 4 mm catheter tip. Power output was adjusted automatically during energy delivery in a closed loop system (preselected temp.: 70.1 +/- 5.8 degrees C). RESULTS: Accessory pathway conduction was successfully abolished in all patients after the delivery of 2.3 +/- 2.1 radiofrequency pulses (range: 1-9, median: 2). Interruption of the accessory pathway as evidenced by loss of preexcitation occurred after 5.9 +/- 5.4 s. At the time of the interruption of the accessory pathway the catheter tip temperature measured 54.2 +/- 11.2 degrees C in patients with left and 44.9 +/- 5.0 degrees C in patients with right sided accessory pathways, respectively (P < 0.008). Higher temperature levels during left sided applications did not shorten the time it took for the effect to appear (left sided accessory pathway: 7.5 +/- 6.3 s, right sided accessory pathway: 3.7 +/- 2.9 s; ns). The catheter tip temperature was significantly higher during left compared to right sided applications after 5 (52.1 +/- 3.1 degrees C vs 47.2 +/- 4.3 degrees C) and 10 s (61.5 +/- 6.2 degrees C vs 52.7 +/- 4.2 degrees C) following initiation of the impulse (P < 0.005). Power output and delivered energy did not differ significantly at the time of accessory pathway abolition. Peak values of delivered power (45.1 +/- 10.9 W vs 41.3 +/- 10.6 W; P < 0.05) and total delivered energy (2452 +/- 1335 J vs 1392 +/- 762 J; P < 0.02) were significantly higher in the group of right sided pathways compared to left sided applications. The peak temperature measured 77.1 +/- 13 degrees C during effective and 69.9 +/- 14 degrees C during ineffective energy applications (P < 0.05). The time it took for the effect to appear was significantly longer in transiently effective pulses (10.4 +/- 7.2 s) compared to permanently effective applications (5.9 +/- 5.4 s; P < 0.02). Despite temperature control, an abrupt rise in impedance was observed in 10 of 89 (11%) energy applications. No procedure-related complications occurred. CONCLUSIONS: Temperature-controlled radiofrequency ablation of manifest accessory pathways is highly effective and safe. The temperature response is faster and significantly higher in left-sided energy applications compared to right-sided pulses. Peak temperature levels measured at the electrode tip are significantly higher during effective than ineffective pulses. Sudden rises in impedance are not completely prevented during temperature-controlled radiofrequency ablation of accessory pathway, although no procedure-related complications were noted in this patient cohort.

Adult↗

Temperature-controlled slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia using a combined anatomical and electrogram guided strategy.

AIMS: Anatomical and electrogram-guided techniques have been used separately for slow pathway ablation in atrioventricular nodal reentrant tachycardia. The aims of the present study were to analyse electrogram characteristics of target sites and biophysical parameters using a combined anatomical and electrogram-guided technique for temperature-controlled radiofrequency catheter ablation of the slow pathway. METHODS AND RESULTS: Using a temperature-controlled (pre-selected 60 degrees C) catheter system, 53 patients with atrioventricular nodal reentrant tachycardia underwent slow pathway radiofrequency ablation. Mapping was started posteroseptally near the coronary sinus ostium and continued towards the midseptal area if needed. The longest and latest atrial electrograms with an atrioventricular ratio of < or = 0.5 were targeted. After a median of two pulses (mean 2.36 +/- 1.33), atrioventricular nodal reentrant tachycardia was rendered non-inducible in all patients without complications. Successful sites had longer atrial electrograms (78.8 +/- 9.8 vs 67.6 +/- 13.3 ms, P < 0.003) and larger ventricular electrogram amplitudes (92.4 +/- 51.2 vs 63.1 +/- 28.8 mV, P < 0.05) than the failed sites, but had a similar atrioventricular ratio, P-A interval and atrial electrogram amplitude. Overall, an atrial electrogram duration of > or = 70 ms was associated with effective radiofrequency delivery, with 86% sensitivity and 62% specificity. The achieved temperature maximum was 62.3 +/- 9.8 degrees C at successful and 58.8 +/- 9.0 degrees C at unsuccessful sites (ns). There was no significant difference between successful and unsuccessful applications with respect to power output, impedance and total delivery energy. During a pre-discharge study, three patients with inducible atrioventricular nodal reentrant tachycardia underwent a repeat ablation. During 12.3 +/- 2.5 (6-15) months of follow-up, three others had a clinical recurrence of atrioventricular nodal reentrant tachycardia. CONCLUSIONS: The combined approach for slow pathway ablation is highly effective, requiring a low number of radiofrequency pulses. Long atrial activation time seems to be the most powerful predictor of success. Similar catheter tip temperature levels during successful and unsuccessful radiofrequency applications indicate that suboptimal selection of target sites rather than ineffective heating due to poor catheter tissue coupling is responsible for unsuccessful energy delivery.

Adolescent↗

Biphasic defibrillation using a single capacitor with large capacitance: reduction of peak voltages and ICD device size.

The volume of current implantable cardioverter defibrillators (ICD) is not convenient for pectoral implantation. One way to reduce the size of the pulse generator is to find a more effective defibrillation pulse waveform generated from smaller volume capacitors. In a prospective randomized crossover study we compared the step-down defibrillation threshold (DFT) of a standard biphasic waveform (STD), delivered by two 250-microF capacitors connected in series with an 80% tilt, to an experimental biphasic waveform delivered by a single 450-microF capacitor with a 60% tilt. The experimental waveform delivered the same energy with a lower peak voltage and a longer duration (LVLD). Intraoperatively, in 25 patients receiving endocardial (n = 12) or endocardial-subcutaneous array (n = 13) defibrillation leads, the DFT was determined for both waveforms. Energy requirements did not differ at DFT for the STD and LVLD waveforms with the low impedance (32 +/- 4 omega) endocardial-subcutaneous array defibrillation lead system (6.4 +/- 4.4 J and 5.9 +/- 4.2 J, respectively) or increased slightly (P = 0.06) with the higher impedance (42 +/- 4 omega) endocardial lead system (10.4 +/- 4.6 J and 12.7 +/- 5.7 J, respectively). However, the voltage needed at DFT was one-third lower with the LVLD waveform than with the STD waveform for both lead systems (256 +/- 85 V vs 154 +/- 51 V and 348 +/- 76 V vs 232 +/- 54 V, respectively). Thus, a single capacitor with a large capacitance can generate a defibrillation pulse with a substantial lower peak voltage requirement without significantly increasing the energy requirements. The volume reduction in using a single capacitor can decrease ICD device size.

Adult↗

Improved sensing signals after endocardial defibrillation with a redesigned integrated sense pace defibrillation lead.

Adequate sensing is a basic requirement for appropriate therapy with ICDs. Integrated sense pace defibrillation leads, which facilitate ICD implantation, show a close proximity of sensing and defibrillation electrodes that might affect the sensing signal amplitude by the high currents of internal defibrillation. In 99 patients, we retrospectively examined two integrated sense pace defibrillation leads, either both with a distance of 6 mm between the tip of the lead (sensing cathode) and the right ventricular defibrillation electrode (sensing anode) or one with a distance of 12 mm. Three seconds after a shock of 20 J, mean sensing signal amplitude during sinus rhythm (SR) decreased from 10.5 +/- 4.3 mV to 5.1 +/- 3.7 mV (P < 0.001) for the 6-mm lead, but showed no significant decrease for the 12-mm lead. The degree of signal reduction was inversely related to the time passed since defibrillation. Significant differences in reduction of sensing signal amplitude concerning monophasic and biphasic shocks could not be observed. Mean sensing signal amplitude of VF after shocks that failed to terminate it decreased in the same order as during SR (from 8.3 +/- 4.1 mV to 4.1 +/- 3.2 mV), but resulted in no failure of redetection during ongoing VF. DFTs did not differ for the 6-mm and the 12-mm lead. In conclusion, close proximity of the right ventricular defibrillation coil to the sensing tip of an integrated sense pace defibrillation lead causes energy and time related reduction in sensing signal amplitude after defibrillation, and might cause undersensing in the postshock period. A new lead design with a more proximal position of the right ventricular defibrillation coil avoids these problems without impairing DFTs.

Defibrillators, Implantable↗

Variants of preexcitation--specialized atriofascicular pathways, nodofascicular pathways, and fasciculoventricular pathways: electrophysiologic findings and target sites for radiofrequency catheter ablation.

INTRODUCTION: In the present report, the electrophysiologic findings in patients with different types of variants of preexcitation, i.e., atriofascicular, nodofascicular, and fasciculoventricular fibers, and the results of radiofrequency catheter ablation using different target sites are described. METHODS AND RESULTS: Twelve patients (mean age 36 +/- 17 years) with variants of the preexcitation syndromes underwent electrophysiologic study and radiofrequency catheter ablation. The atrial origin of atriofascicular pathways remote from the normal AV node was assessed by application of late atrial extrastimuli that advanced ("reset") the timing of the next QRS complex without anterograde penetration into the AV node. In patients with atriofascicular pathways, ablation of the accessory pathway or the retrograde fast AV node pathway was attempted. Ablation of the atriofascicular pathways was guided by a stimulus-delta wave interval mapping in the first five patients and by recording of atriofascicular pathway activation potentials in the next five patients. A nodofascicular pathway was suggested if VA dissociation occurred during tachycardia and if atrial extrastimuli failed to reset the tachycardia without anterograde penetration into the AV node. A fasciculoventricular connection was suggested if the proximal insertion of the accessory pathway was found to arise from the His bundle or bundle branches. The PR interval was expected within normal limits during sinus rhythm and the QRS complex to be slightly prolonged with a discrete slurring of the R wave, suggesting a small delta wave. Ten of the 12 patients had evidence for atriofascicular pathways and one patient each for a nodofascicular and fasciculoventricular pathway. In six patients, the atriofascicular pathways were successfully ablated, and in two patients, the retrograde fast AV node pathway. In one patient, a concealed right posteroseptal accessory AV pathway served as the retrograde limb and was successfully ablated. The nodofascicular pathway was shown to be a bystander during AV node reentrant tachycardia. After successful fast AV node pathway ablation resulting in marked PR prolongation, no preexcitation was present during sinus rhythm because of the proximal insertion of the nodofascicular pathway distal to the delay producing parts of the AV node. The proximal insertion of the fasciculoventricular pathway was suggested to arise distal to the AV node at the site of the penetrating AV bundle. The earliest ventricular activation at the His-bundle recording site indicated the ventricular insertion of this accessory connection into the ventricular summit. The fasciculoventricular connection gave rise to a fixed ventricular preexcitation and served as a bystander during orthodromic AV reentrant tachycardia incorporating a left-sided accessory AV pathway. CONCLUSION: The majority of patients with variants of the preexcitation syndrome present with specialized atriofascicular pathways that seem to originate from remnants of the specialized AV ring tissue. Nodofascicular and fasciculoventricular pathways exist and may give rise to preexcitation, although their functional role in participation of clinical arrhythmias still needs to be elucidated. In the present study, both a fasciculoventricular pathway and a nodofascicular pathway acted as a bystander.

Adolescent↗

Antithrombin III and fibrinogen as predictors of cardiac events in patients with angina pectoris.

Because measurements of hemostatic factors might aid the prediction of cardiovascular clinical events, we investigated the long-term prognostic importance of selected hemostatic factors in patients with angina pectoris. At recruitment, 209 patients underwent clinical assessment and coronary angiography, and a range of hemostatic factors were measured. During the follow-up period of 9 years, 58 patients (28%) suffered a cardiac event (acute myocardial infarction or death from cardiac causes). The risk of cardiac events was positively related to baseline measurements of fibrinogen (risk ratio per SD [RR] increase 1.29, 95% confidence interval [CI] 0.99 to 1.68, P=.06) and negatively related to antithrombin III activity measurements (RR 0.75, 95% CI 0.59 to 0.95, P=.02). No other hemostatic factor measured was significantly related to the risk of having a cardiac event. Worsening of angina in the few weeks before and ejection fraction evaluation at the initial angiography were both strongly related to the risk of cardiac events. However, the relationships of fibrinogen and antithrombin III measurements to risk remained almost unchanged after adjusting for worsening of angina and ejection fraction. Fibrinogen and antithrombin III may have an important etiologic role in the prognosis of patients with angina pectoris.

Adult↗

Heparin-induced overexpression of basic fibroblast growth factor, basic fibroblast growth factor receptor, and cell-associated proteoheparan sulfate in cultured coronary smooth muscle cells.

Basic fibroblast growth factor (bFGF), a potent mitogen for arterial smooth muscle cells (SMCs), plays a pivotal role in the pathogenesis of arteriosclerosis and restenosis. Heparin in nanogram quantities may promote or even be required for binding of bFGF to its cognate receptor. Conversely, heparin in microgram doses is a strong inhibitor of arterial SMC replication in vitro and in vivo. Bovine coronary SMCs (cSMCs) express bFGF, bFGF receptor (FGF-R1), and cell membrane-integrated proteoheparan sulfate (HSPG). These three molecules are known to form a trimolecular complex that promotes signal transduction and mitogenesis. The bFGF synthesized by cSMCs is distributed to an intracellular and a pericellular compartment. Resting cultured cells retain about 80% of their bFGF intracellularly; 20% is found in the pericellular region. During proliferation, 70% to 80% of total bFGF is expressed in the pericellular compartment. Trypsinization generates soluble forms of the complex of bFGF with the ectodomains of the bFGF receptor and cell membrane-integrated HSPG in the pericellular compartment, thus allowing quantification of pericellular bFGF by a highly specific enzyme immunoassay. Standard heparin inhibits the proliferation of cSMCs by up to 80% in a concentration range between 10 and 100 micrograms/mL medium in a dose-dependent manner but increases the protein content of cSMCs compared with proliferating control cells. The heparin-induced increase in cellular protein content includes a 60% to 100% increase in the expression of pericellular bFGF, FGF-R1, and cell membrane-integrated HSPG. Thus, under heparin treatment, the heparan sulfate side chains of cell membrane-integrated HSPG incorporate more [35S]sulfate, and the proportion of [35S]heparan sulfate among total glycosaminoglycans increases from 36% to 52%. Fluorescence-activated cell sorting analysis and [3H]thymidine incorporation experiments provide evidence for multiple effects of heparin, including blocks at early and late checkpoints of the cell cycle in heparin-treated cells. These results indicate that heparin, despite its anti-proliferative potency, stimulates the expression of all components of the bFGF system even in coronary SMCs in which growth is inhibited.

Animals↗

Implantable cardioverter-defibrillator: present and future indications.

Indications for of automatic cardioverter-defibrillators of automatic in patients with ventricular tachyarrhythmias have changed since the publications of first guidelines in 1991. Less invasive surgical approaches reduced the perioperative mortality. Tiered therapy devices improved the quality of life by reducing appropriate and inappropriate shocks. A low annual incidence of sudden death with implantable cardioverter defibrillators and frustrating results with antiarrhythmic drugs caused an extension of implantable cardioverter-defibrillator indications. Despite the absence of prospective studies implantable cardioverter-defibrillators have become a first line treatment for patients with ventricular tachyarrhythmias which are not due to acute myocardial infarction. In cardiac arrest survivors implantable cardioverter-defibrillator therapy has become the gold standard due to the low annual incidence of sudden death seen in implantable cardioverter-defibrillator patients. The results of ongoing prospective studies comparing implantable cardioverter-defibrillator therapy to antiarrhythmic drugs have to be awaited and will influence tomorrow's indications for implantable cardioverter-defibrillator therapy in patients with documented ventricular tachyarrhythmias. Additionally, studies evaluating prophylactic implantable cardioverter-defibrillator implantations in patients at high risk for ventricular tachyarrhythmias might expand indications for implantable cardioverter-defibrillator therapy.

Cardiac Pacing, Artificial↗

[Intravascular sonographic findings after orthotopic heart transplantation: comparison with clinical factors].

30 patients (mean age 51.4 +/- 11.6 years; female n = 6) were studied early after orthotopic heart transplantation (11.6 +/- 5.5 weeks). Twelve recipients had undergone specific treatment for biopsy proven rejection. Using a mechanical intravascular ultrasound device (3.5-F catheter), 153 coronary artery segments (16 left coronary main stem, 122 left anterior descending artery, 15 left circumflex artery) were studied. Intimal index and circumferential extension of a three-layer appearance of the vessel wall were assessed. In all segments, systolic-diastolic changes in area (delta A) with respect to vessel area and pressure (delta P) were used to study normalized compliance (normalized compliance = [delta A/A]/delta P [mm Hg-1 x 10(3)]). Intravascular ultrasound findings were correlated to perioperative ischemia time, LDL/HDL-ratio, Lp(a) and donor age. In a subgroup of 13 recipients, intravascular ultrasound investigation was repeated after an interval of 67.4 +/- 10.2 weeks. At first investigation, mean intimal index of all coronary segments was 0.07 +/- 0.10. Mean circumferential extension of a three-layer appearance of the vessel wall was 84 +/- 112 degrees. Normalized compliance was 2.43 +/- 1.90 mm Hg-1 in the left main stem 2.45 +/- 1.47 mm Hg-1 within the left anterior descending artery, and 2.66 +/- 1.72 mm Hg-1 within the circumflex artery (differences n.s.). No correlation was found between intimal index and normalized compliance (r = -0.322), nor between circumferential extension of intimal thickening and normalized compliance (r = -0.362). Furthermore, there was no correlation between normalized compliance and donor age. Normalized compliance was significantly lower in recipients with proven rejection than in those without (1.76 +/- 0.81 versus 2.95 +/- 1.22 mm Hg-1, p = 0.005). Both, intimal index and circumferential extension of intimal thickening, were significantly higher in recipients following rejection periods (p < 0.05). The extent of coronary vessel wall alterations on ultrasound correlated to donor age but not to perioperative ischemia time, LDL/HDL-ratio and Lp(a). Re-investigation of a subgroup of 13 recipients 67.4 +/- 10.2 weeks after the first study showed an insignificant increase of the intimal index (from 0.03 to 0.09) and of the circumferential extension of intimal thickening (from 40 to 111 degrees). Normalized compliance changed from 2.53 +/- 1.48 to 2.87 +/- 1.33 mm Hg-1 (differences n.s.). Early after orthotopic heart transplantation, a significant correlation between atherosclerotic coronary vessel wall alterations assessed by intravascular ultrasound and donor age can be confirmed. Heart recipients following rejection periods present with significantly more atherosclerotic vessel wall alterations and a severely reduced compliance of the coronary vessels.

Adult↗

[Inadequate therapies with implantable cardioverter-defibrillators--incidence, etiology, predictive factors and preventive strategies].

Patients with implantable cardioverter defibrillators (ICD) often suffer inappropriate ICD-therapies. The incidence, causes and risk factors of ICD-therapies for a rhythm other than ventricular tachyarrhythmias (VT) were determined retrospectively in 462 consecutive patients (pts). Inappropriate ICD-therapies were identified based on stored R-R intervals and/or electrograms. Eighty-two pts (18%) had inappropriate ICD-therapies. Actuarial rates for inappropriate ICD-therapies were 13%, 20%, 24% and 29% at 1, 2, 3 and 4 years after ICD-implantation, respectively. Atrial fibrillation with rapid ventricular response was the most common cause (34 pts, 39%). In 26 pts (30%), sinus tachycardia triggered inappropriate ICD-therapies, in 21 pts (24%) overseeing, mostly due to fractures and insulation failures of the leads, in three pts atrial flutter, in two pts non-sustained VT, in one pt supra-ventricular tachycardia and in another pt T-wave double sensing caused inappropriate ICD-therapies. In order to prevent recurrences of inappropriate ICD-therapies due to atrial fibrillation or sinus tachycardia, a rate stability (n = 19) or onset (n = 15) criterion was programmed, 41 pts additionally received beta-blocking agents and/or digoxin. In pts with overseeing an operative revision of lead system was performed. During further follow-up (15 +/- 13 months), 15 pts had recurrences of inappropriate ICD-therapies (eight pts due to atrial fibrillation, three due to sinus tachycardia and four due to overseeing). On multivariate analysis (Cox regression), history of atrial fibrillation, maximum heart rate during exercise and low cut-off rate for VT-detection were predictors of inappropriate ICD-therapies. Thus, inappropriate ICD-therapies are frequent, especially in the first year after implantation. Additional detection criteria, beta-blocking agents and/or digoxin prevent recurrences in most patients. In patients with a history of atrial fibrillation, high heart rate during exercise or a low cut-off rate for VT-detection, activation of additional detection criteria should be considered directly after ICD-implantation.

Adult↗

[Methods of catheter ablation in ventricular tachycardic arrhythmias].

Catheter ablation has evolved as the therapy of choice in patients with atrioventricular nodal reentrant tachycardia or atrioventricular tachycardia involving accessory pathways. Radiofrequency current catheter ablation is now generally accepted and most frequently used. In patients with ventricular tachycardia and no organic heart disease (idiopathic ventricular tachycardia) the success rates range between 80-90%. In addition, in patients with bundle branch reentrant tachycardia up to 100% success rates are described. The usefulness of radiofrequency ablation in patients with structural heart disease is still controversial. Although in patients with incessant ventricular tachycardia high acute success rates are observed, the results in post-myocardial infarction tachycardia or dilative cardiomyopathy range only between 40 and 75%. Further refinement of localization techniques as well as improvement of ablation technology is mandatory until the routine use of this technique as a curative procedure for ventricular tachycardia is defined.

Atrioventricular Node↗

[Pharmacologic therapy of ventricular tachyarrhythmias: value of class III anti-arrhythmia drugs].

Treatment strategies in patients with life-threatening ventricular tachyarrhythmias (i.e. sustained ventricular tachycardia, ventricular fibrillation, aborted sudden cardiac death) are changing. Amiodarone and d,l-sotalol, chosen by electrophysiologic study guidance, can be considered as drugs of choice for the pharmacological treatment. Compared to these agents, which both have additional electrophysiologic effects, the new pure class III agents seem to be less effective. With regard to antiarrhythmic efficacy, clinical trials comparing the long-term efficacy of antiarrhythmic agents and the implantable cardioverter/defibrillator are under way. Preliminary results indicate that the implantable cardioverter/defibrillator may provide superior outcome with regard to sudden cardiac death compared to the use of class III agents.

Amiodarone↗

The relation of interleukin-6, tumor necrosis factor-alpha, IL-2, and IL-2 receptor levels to cellular rejection, allograft dysfunction, and clinical events early after cardiac transplantation.

Immunoregulatory cytokines have been implicated in the pathophysiology of graft dysfunction after heart transplantation (HTx). In 15 consecutive patients undergoing HTx we prospectively determined levels of interleukin-6 (IL-6), tumor-necrosis-factor-alpha (TNF-alpha), interleukin-2 (IL-2), and soluble-interleukin-2-receptor (sIL-2-R) at eight points in time during biopsy and right heart catheterization and within 12 hr of echocardiography during the first three months after HTx. Blood was taken from the pulmonary arterial line. IL-6-levels correlated positively with hemodynamic and echocardiographic parameters of pump dysfunction--namely, pulmonary capillary wedge pressure, pulmonary arterial pressure, right atrial pressure, heart rate--and negatively with isovolumic relaxation time and stroke volume independent of the degree of cellular rejection as classified by the ISHLT criteria. A similar pattern was found for TNF-alpha- and sIL-2-R, while IL-2 correlated negatively with left and right heart filling pressures and positively with fractional shortening. In the three patients who died of sepsis or multiorgan failure within the study period IL-6-, TNF-alpha, and sIL-2-R-levels were elevated and IL-2-levels were suppressed compared with the 12 patients with a stable clinical course. IL-6 and sIL-2-R correlated positively while IL-6 and IL-2 correlated negatively. In this pilot study, a cytokine pattern with elevated levels of IL-6, TNF-alpha, and sIL-2-R as well as suppressed levels of IL-2 in the early period after HTx corresponds to impaired hemodynamics independent of cellular rejection and may indicate an unfavorable prognosis. These cytokines may therefore be useful for monitoring and warrant further study.

Adult↗