Search PubMed⌕ Search

Biomedical subjects

G Brandon

Publications and source records attributed to G Brandon.

14 recordsLinked to original sources

[The medical record].

Explore the source record for details and available documents.

Continuity of Patient Care↗

Comparative hemodynamic effects of intravenous dobutamine and MDL-17,043, a new cardioactive drug, in severe congestive heart failure.

In 14 patients with severe congestive heart failure (CHF) due to ischemic heart disease or idiopathic dilated cardiomyopathy, the hemodynamic response to intravenous infusion of dobutamine (D) was compared to that of a new non-catechol, non-glycoside, inotropic and vasodilator agent, MDL-17,043 (MDL) administered in incremental intravenous doses. D and MDL produced comparable increases in cardiac index (L/min/m2) (1.8 +/- 0.4 to 2.9 +/- 0.8 and 1.7 +/- 0.3 to 3.3 +/- 0.6, respectively; both p = 0.001) and stroke volume index (ml/beat/m2) (24 +/- 8 to 35 +/- 9 and 22 +/- 7 to 39 +/- 11, respectively; both p = 0.001). Both D and MDL reduced left ventricular filling pressure (29 +/- 5 to 24 +/- 5 and 29 +/- 6 to 17 +2- 6 mm Hg, respectively; both p less than 0.05), and mean right atrial pressure (11 +/- 4 to 8 +/- 4 and 13 +/- 5 to 6 +/- 4 mm Hg, respectively; both p = 0.001). The overall changes in heart rate and mean arterial pressure were small with both D and MDL. However, MDL in comparison to D resulted in a significantly lower left ventricular filling pressure (p = 0.001), mean pulmonary arterial pressure (p = 0.001), and mean arterial pressure (p less than 0.05). The salutary hemodynamic effects of MDL on cardiac index and left ventricular filling pressure were sustained for an average of 9.6 hours, whereas the effects of D dissipated within 30 minutes of stopping the infusion. No serious adverse effects were noted during acute administration with either drug. Therefore, intravenous MDL may be a useful substitute for D in the acute therapy of severe CHF.

Aged↗

[Isotope angiocardiography: amelioration of the measurement of ejection fraction by a new treatment of the image].

Some of the limitations affecting radioisotopic images are their insufficient resolution, structure boundaries and accurate subtraction of background noise. In order to improve the signal-to-noise ratio the images of the recorded heart cycles are treated by the Karhunen-Loeve transformation. Edge detection is based on compression of the image to a bitmap at a chosen level and following of all bits set to one by a pointer. The outlines of the structures as determined by edge tracking are used to define the regions of interest within the enhanced images. Background subtraction applies the principle of interpolative background subtraction by computing an individual background for each point in an irregular region of interest. The resultant images are used to calculate an index of cardiac efficiency which shows high correlation (r = 0.92) with the ejection fraction of contrast biplane left ventricular angiography.

Cardiac Output↗

Echocardiographic changes of cardiac structures and LV function in newborns. A comparative study between normally delivered babies and babies born by caesarian section with regional anaesthesia.

Cardiac chamber size and function indices were studied repeatedly over the first months of life in two groups of babies, born either spontaneously or by caesarian section under peridural anaesthesia. For cardiac chamber size, no significant differences were found between the two groups: cardiac structures increased in size as a linear function of age and weight in all babies. Right ventricular systolic time interval ratios, however, were higher at birth in babies born by caesarian section, and dropped more rapidly during the first 24h. The decrease of RV systolic time interval ratios followed a parabolic function for both groups, thus reflecting the physiological decrease of pulmonary vascular resistance after birth. The possible causes of more rapid decrease in pulmonary vascular resistance in babies born by caesarian section is discussed.

Age Factors↗

Echocardiographic growth patterns of intracardiac dimensions and determination of function indices during the first year of life.

Cardiac dimensions and left and right ventricular function indices were studied consecutively in 53 healthy newborn babies throughout their first year of life. Cardiac dimensions, except right ventricular (RV) dimension, increase linearly with age, weight and body surface area, the relation being best described as a linear function of BSA. Left ventricular function indices do no change significantly during the first year of life. Right ventricular systolic time interval ratio (RVPEP/RVET) is high at birth, but declines rapidly during the first hours and days. This change is best described as a parabolic function and is an indicator of the physiological fall of pulmonary vascular resistances.

Anthropometry↗

Graphical computer techniques for improving the detection of myocardiac ischemia.

Traditional investigative methods to detect and localise cardiac abnormalities are often difficult and time consuming. The use of minicomputers has made a dramatic impact on non-invasive diagnostic techniques in cardiac patients. The Cardiology Division of the Geneva University Hospital has assembled a minicomputer-based data acquisition/visualisation system to study cardiac structures and their associated motions using radionuclide techniques.

Computers↗

Growth patterns of cardiac structures and changes in systolic time intervals in the newborn and infant. A longitudinal echocardiographic study.

A longitudinal study was undertaken in 21 newborns to determine cardiac growth pattern by echocardiography over the course of the first year of life. Most cardiac structures increased in size as a linear function of age and weight; however, the right ventricular end-diastolic diameter remained unchanged so that the RV/LV ratio decreased as a parabolic function of age. Left and right ventricular systolic time intervals (RVSTI, LVSTI) after birth were also studied. The ratio of left ventricular preejection period (LVPEP) to left ventricular ejection time (LVET) decreased markedly immediately after birth and subsequently remained at a constant mean value (0.30 +/- 0.04) for the rest of the study period. Right ventricular systolic time interval ratios (RVPEP/RVET) decreased rapidly and significantly during the first day of life (from a mean value of 0.39 +/- 0.08 in the first 24 hours to 0.28 +/- 0.05 on the 6th day of life). Constant values of 0.24 +/- 0.03 were found from the 3rd month of life onwards. The decrease in RVPEP/RVET in the first days of life followed a parabolic function reflecting the physiological decrease of pulmonary vascular resistance after birth.

Body Weight↗

Pasteurella multocida. Infections after domestic animal bites and scratches.

Pasteurella multocida is a common cause of infection followingbites or scratches caused by dogs and cats. However, it is rarely reported and appar-ently often overlooked as a pathogen. It causes the typical clinical manifestationsof a rapidly developing cellulitis at the site of injury. The infection is potentiallydangerous and can cause a chronic local infection of deep tissues and septicemia. However, it responds well to several antimicrobials, with penicillin being the drug ofchoice

Adolescent↗