Search PubMed⌕ Search

Biomedical subjects

G Bortel

Publications and source records attributed to G Bortel.

8 recordsLinked to original sources

Classification of continuous diffraction patterns: a numerical study.

The very intense and short pulses of future X-ray free electron lasers may allow the atomic resolution imaging of small, non-periodic objects. Preliminary estimates show that images obtained from single pulses do not contain statistically enough photons to allow successful reconstruction. Therefore multiple exposures of randomly oriented identical replicas have to be taken and the individual images have to be classified according to the object's orientation. The classification has been analytically treated by Huldt et al. [Huldt, G., Szoke, A., Hajdu, J., 2003. J. Struct. Biol. 144, 219.]. In this paper we extend the analytical results with numerical model calculations. This allows us to simulate realistic situations, which we will face in real experiments. We find significant deviations from the analytical expectations, even in the ideal case of spherical particles with random atomic distributions. We introduce a new norm for the individual scattering patterns and describe a criterion to select images belonging to similar orientation, which makes the classification more reliable in practice. We also discuss the effects of particle shape and size, partial orientational ordering, the measurement's resolution and the charge error caused by the Coulomb explosion.

Imaging, Three-Dimensional↗

Crystal monochromator with a resolution beyond 10(8).

Monochromatization with crystal diffraction has been achieved to a resolution (lambda/delta lambda) beyond 10(8). The monchromator is specifically designed for 23.880 keV synchrotron radiation (lambda = 51.9 pm) for applications involving nuclear resonant scattering from 119Sn. The design uses asymmetrically cut silicon (12 12 12) crystal reflections from two single-crystalline monoliths oriented in a dispersive geometry. A transmitted energy bandwidth of 140 +/- 20 mu eV was measured, corresponding to a resolution of 1.7 x 10(8). Methods of improving efficiency, wavelength stability and resolution are discussed.

Journal Article↗

Wavelength-dispersive double flat-crystal analyzer for inelastic X-ray scattering.

A double flat-crystal analyzer for inelastic X-ray scattering is described. The general correlation between the energy and direction of the X-rays transmitted by the analyzer allows one to collect data for a range of energy transfers simultaneously. Such an analyzer with 120 meV resolution was built to operate at the copper K edge. Experimental results show that this X-ray optic can be an alternative to a conventional spherical-focusing backscattering analyzer in resonant inelastic X-ray scattering experiments or when flexible energy resolution or high momentum resolution is required.

Journal Article↗