Search PubMed⌕ Search

Biomedical subjects

G B Stephenson

Publications and source records attributed to G B Stephenson.

9 recordsLinked to original sources

Stabilization of monodomain polarization in ultrathin PbTiO3 films.

Using in situ high-resolution synchrotron x-ray scattering, the Curie temperature TC has been determined for ultrathin c-axis epitaxial PbTiO3 films on conducting substrates (SrRuO3 on SrTiO3), with surfaces exposed to a controlled vapor environment. The suppression of TC was relatively small, even for the thinnest film (1.2 nm). We observe that 180 degrees stripe domains do not form, indicating that the depolarizing field is compensated by free charge at both interfaces. This is confirmed by ab initio calculations that find polar ground states in the presence of ionic adsorbates.

Journal Article↗

Nanometer linear focusing of hard x rays by a multilayer Laue lens.

We report on a type of linear zone plate for nanometer-scale focusing of hard x rays, a multilayer Laue lens (MLL), produced by sectioning a multilayer and illuminating it in Laue diffraction geometry. Because of its large optical depth, a MLL spans the diffraction regimes applicable to a thin Fresnel zone plate and a crystal. Coupled wave theory calculations indicate that focusing to 5 nm or smaller with high efficiency should be possible. Partial MLL structures with outermost zone widths as small as 10 nm have been fabricated and tested with 19.5 keV synchrotron radiation. Focal sizes as small as 30 nm with efficiencies up to 44% are measured.

Journal Article↗

Clocking femtosecond X rays.

Linear-accelerator-based sources will revolutionize ultrafast x-ray science due to their unprecedented brightness and short pulse duration. However, time-resolved studies at the resolution of the x-ray pulse duration are hampered by the inability to precisely synchronize an external laser to the accelerator. At the Sub-Picosecond Pulse Source at the Stanford Linear-Accelerator Center we solved this problem by measuring the arrival time of each high energy electron bunch with electro-optic sampling. This measurement indirectly determined the arrival time of each x-ray pulse relative to an external pump laser pulse with a time resolution of better than 60 fs rms.

Journal Article↗

In situ synchrotron X-ray studies of ferroelectric thin films.

In situ synchrotron X-ray scattering was used to observe both the growth of PbTiO3 films by metal-organic chemical vapour deposition and the behaviour of the ferroelectric phase transition as a function of film thickness. The dependences of growth mode and deposition rate on gas flows and substrate temperature were determined by homoepitaxial growth studies on thick films (>50 nm). These studies facilitated the growth of thin coherently strained PbTiO3 films on SrTiO3 (001) substrates, with thicknesses ranging from 2 to 42 nm. Experiments on the ferroelectric phase transition as a function of film thickness were carried out in these films under controlled mechanical and electrical boundary conditions.

Journal Article↗

Observation of nanoscale 180 degrees stripe domains in ferroelectric PbTiO3 thin films.

We report the observation of periodic 180 degrees stripe domains below the ferroelectric transition in thin films. Epitaxial PbTiO3 films of thickness d=1.6 to 42 nm on SrTiO3 substrates were studied using x-ray scattering. Upon cooling below T(C), satellites appeared around Bragg peaks indicating the presence of 180 degrees stripe domains of period Lambda=3.7 to 24 nm. The dependence of Lambda on d agrees well with theory including epitaxial strain effects, while the suppression of T(C) for thinner films is significantly larger than that expected solely from stripe domains.

Journal Article↗

Antiferrodistortive reconstruction of the PbTiO(3)(001) surface.

We present in situ x-ray scattering measurements of the surface structures of PbTiO(3) (001) in equilibrium with PbO vapor. At 875 to 1025 K, a reconstruction having c(2x2) symmetry is present under most conditions, while a 1 x 6 reconstruction occurs under PbO-poor conditions. The atomic structure of the c(2x2) phase is found to consist of a single layer of an antiferrodistortive structure with oxygen cages counter-rotated by 10 degrees about the titanium ions.

Journal Article↗

Absence of scaling for the intermediate scattering function of a hard-sphere suspension: static and dynamic x-ray scattering from concentrated polystyrene latex spheres.

X-ray photon correlation spectroscopy and small-angle scattering measurements are presented of the dynamics and structure of concentrated suspensions of charge-stabilized polystyrene latex spheres dispersed in glycerol, for volume fractions from 3% to 52%. The static structures of the suspensions show essentially hard-sphere behavior, and the short-time dynamics shows good agreement with predictions for the wave-vector-dependent collective diffusion coefficient. However, the intermediate scattering function is found to violate a scaling behavior found previously for a sterically stabilized hard-sphere suspension.

Journal Article↗

Small-angle X-ray scattering using coherent undulator radiation at the ESRF.

A simple approach for producing a high-coherent-flux X-ray beam for small-angle-scattering studies used at the Troika beamline of the European Synchrotron Radiation Facility is reported. For such small-angle studies it is permissible to reduce the longitudinal coherence .length of the beam, thus increasing the energy bandpass and intensity of the beam, because there is only a small optical path-length difference. By using mirrors and filters to cut unwanted energies from the undulator harmonic structure, a high-flux beam of >10(9) photons s(-1) through a 5 micron-diameter pinhole at 8.2 keV with a bandpass of 1.3% can be produced. The coherent properties of this beam have been measured by analyzing a static speckle pattern from an aerogel sample imaged by a directly illuminated CCD camera. The speckle size and contrast are compared with the expected values based on a statistical analysis of the intensity distribution of speckle patterns obtained using partially coherent conditions. The expected widths of the spatial autocorrelation are found, but there is an apparent incoherent fraction of the beam which reduces the measured contrast. The method presented is to be used as a tool to optimize conditions for diffraction experiments using coherent X-rays.

Journal Article↗

Perfect Crystals in the Asymmetric Bragg Geometry as Optical Elements for Coherent X-ray Beams.

Perfect crystals in the asymmetric Bragg geometry are evaluated as optical elements for manipulating coherent X-ray beams. Such optics can be used to modify the transverse coherence length of a synchrotron X-ray beam, with the intention of increasing the usable coherent flux. The wavelength range, angular divergence and flux of X-rays passing through a pinhole aperture are examined in detail, as functions of source and pinhole size, crystal-to-pinhole separation and the asymmetry factor. In developing this analysis, the behavior of asymmetrically cut crystals is explained in reciprocal space, with reference to the crystal truncation rod associated with the reflection. The results show that, for synchrotron beams that are collimated to a small fraction of the incident Darwin width, the wavelength range accepted by the crystal is typically dispersed into an angular spread in the exit beam. This chromatic aberration greatly reduces the transverse coherence length in a manner that does not conserve the coherent flux. The calculations are in agreement with measurements of the divergence and flux through a micrometer-sized pinhole using a synchrotron wiggler X-ray source.

Journal Article↗