Search PubMed⌕ Search

Biomedical subjects

G B Pike

Publications and source records attributed to G B Pike.

At least 37 records · Page 2Linked to original sources

Presurgical motor and somatosensory cortex mapping with functional magnetic resonance imaging and positron emission tomography.

OBJECT: Accurate identification of eloquent cortex is important to ensure that resective surgery in the region surrounding the central sulcus is performed with minimum risk of permanent neurological deficit. Functional localization has traditionally been accomplished using intraoperative cortical stimulation (ICS). However, this technique suffers from several disadvantages that make the development and validation of noninvasive methods desirable. Functional localization accomplished by activation studies in which positron emission tomography (PET) scanning and the tracer [15O]H2O have been used has been shown to correlate well with the results of ICS. Another noninvasive method for functional localization is functional magnetic resonance (fMR) imaging. We compared the locations of activation peaks obtained in individual patients using fMR and [15O]H2O PET imaging. METHODS: Twenty-six combined PET activation-fMR imaging studies were performed in 11 patients who were admitted for evaluation before undergoing surgery in the region surrounding the central sulcus. The PET scans were obtained using bolus injections of the cerebral blood flow tracer [15O]H2O (10 mCi). Multislice T2*-weighted gradient-echo echoplanar images were acquired using a 1.5-tesla MR imaging system. Activation maps were aligned with anatomical MR images and transformed into stereotactic space, after which the locations of activation peaks obtained using both modalities were compared. The average distance between activation peaks obtained using fMR imaging and those obtained using PET imaging was 7.9+/-4.8 mm (p>0.05), with 96% of the peaks being located on either the same or adjacent sulci and gyri. Overlapping of voxels activated by each modality occurred in 92% of the studies. Functional MR imaging failed to activate the primary sensorimotor cortex in one study and produced results that were ambiguous in the clinical setting in three cases. CONCLUSIONS: Overall, fMR imaging produced activation that correlated well with that obtained using PET scanning. Discrepancies between the sites of activation identified using these two techniques may reflect differences in their physiological bases.

Brain Diseases↗

Combined magnetization transfer and proton spectroscopic imaging in the assessment of pathologic brain lesions in multiple sclerosis.

BACKGROUND AND PURPOSE: Conventional MR imaging of multiple sclerosis (MS) provides relatively poor pathologic specificity, which has led to the investigation of more sophisticated MR techniques. The purpose of this study was to combine magnetization transfer (MT) imaging and proton MR spectroscopic imaging (MRSI) to evaluate the specific pathologic features of myelination and neuronal integrity in patients with MS and to determine the relationship between these measures within plaques. METHODS: We acquired conventional MR, MT, and proton MRSI data and evaluated clinical disability in 30 patients with MS, whose conditions were categorized as relapsing-remitting, primary progressive, or secondary progressive. The lesions were classified, using a semiautomated edge-following technique, on T2-weighted MR images, and an analysis of MT and proton MRSI data was conducted for lesion regions as well as for tissue that was categorized as normal. RESULTS: The MT ratio (MTR) of normal-appearing white matter in the patients with MS was significantly lower than in the healthy participants, whereas gray matter values were unchanged. MS lesions showed a large reduction in MTR, with old lesions exhibiting a lower MTR than new lesions. The average lesion MTR and the MR spectroscopic imaging-measured relative concentration of N-acetylaspartate, a marker of neuronal integrity, was positively correlated in patients with relapsing-remitting MS. This relationship was strengthened in regions containing new lesions. CONCLUSION: The integrated use of MT and MR spectroscopic imaging provides a more complete description of the pathologic features of MS than does conventional MR imaging alone, and our data suggest that axonal damage occurs in step with new demyelination and is not a late feature of the disease.

Adult↗

Quantitative magnetic resonance imaging in the assessment of degenerative disc disease.

Understanding degenerative intervertebral disc diseases hinges on the ability to objectively and noninvasively assess the disc matrix composition and integrity. The potential of quantitative magnetic resonance imaging to meet these demands was evaluated. Analyzing the T1 and T2 signal patterns in the nucleus pulposus with increasing Thompson morphological grade revealed a significant reduction related to grade. This significant decrease in T1 and T2 in the nucleus pulposus with grade 4 degeneration and the corresponding low correlation coefficients with respect to the content of individual matrix molecules suggest that matrix integrity plays an important and distinct role in determining T1 and T2 signal. Similarly, the significant increase in magnetization transfer in the nucleus pulposus observed in grade 4 degeneration did not correlate with the changes in molecular content in these highly degenerated discs. Again, this lack of correlation clearly indicates that the tissue integrity and matrix composition independently contribute to the magnetization transfer signal. This study presents the first clear evidence that quantitative magnetic resonance analysis reflects not only the disc matrix composition, but also the structural integrity of the matrix of the disc.

Adult↗

Standing-wave and RF penetration artifacts caused by elliptic geometry: an electrodynamic analysis of MRI.

Motivated by the observation that the diagonal pattern of intensity nonuniformity usually associated with linearly polarized radio-frequency (RF) coils is often present in neurological scans using circularly polarized coils, a theoretical analysis has been conducted of the intensity nonuniformity inherent in imaging an elliptically shaped object using 1.5-T magnets and circularly polarized RF coils. This first principle analysis clarifies, for the general case of conducting objects, the relationship between the excitation field and the reception sensitivity of circularly and linearly polarized coils. The results, validated experimentally using a standard spin-echo imaging sequence and an in vivo B1 field mapping technique, are shown to be accurate to within 1%-2% root mean square, suggesting that these electromagnetic interactions with the object account for most of the intensity nonuniformity observed.

Artifacts↗

Density compensation functions for spiral MRI.

In interleaved spiral MRI, an object's Fourier transform is sampled along a set of curved trajectories in the spatial frequency domain (k-space). An image of the object is then reconstructed, usually by interpolating the sampled Fourier data onto a Cartesian grid and applying the fast Fourier transform (FFT) algorithm. To obtain accurate results, it is necessary to account for the nonuniform density with which k-space is sampled. An analytic density compensation function (DCF) for spiral MRI, based on the Jacobian determinant for the transformation between Cartesian coordinates and the spiral sampling parameters of time and interleaf rotation angle, is derived in this paper, and the reconstruction accuracy achieved using this function is compared with that obtained using several previously published expressions. Various nonideal conditions, including intersecting trajectories, are considered. The new DCF eliminated intensity cupping that was encountered in images reconstructed with other functions, and significantly reduced the level of artifact observed when unevenly spaced sampling trajectories, such as those achieved with trapezoidal gradient waveforms, were employed. Modified forms of this function were found to provide similar improvements when intersecting trajectories made the spiral-Cartesian transformation noninvertible, and when the shape of the spiral trajectory varied between interleaves.

Humans↗

Magnetization transfer imaging of multiple sclerosis.

While conventional magnetic resonance imaging (MRI) measures signal primarily from the hydrogen nuclei of water, magnetization transfer (MT) MRI indirectly detects macromolecular associated hydrogen nuclei via their magnetic interaction with the observable water. In the normal adult CNS, white matter exhibits the largest MT effect due to the macromolecular content of the highly structured and lipid rich myelin. Pathologies which alter the structural integrity and the relative macromolecular-water composition, such as multiple sclerosis (MS), therefore show abnormal MT. Conventional MRI, which has a high MS lesion detection sensitivity but poor specificity in terms of differentiating the pathological state of a plaque, can thus be supplemented by MT to provide more specific information on the extent of demyelination and axonal loss. In this paper we review the basic concepts of MT imaging and its role in MS lesion characterization.

Adult↗

Pulsed magnetization transfer contrast in gradient echo imaging: a two-pool analytic description of signal response.

Magnetization transfer (MT) imaging with a rapid gradient-echo sequence and pulsed saturation provides an efficient means of acquiring high resolution three-dimensional data in vivo. This paper presents a derivation of the theoretical steady-state signal equation for this sequence based on the two-site coupled Bloch equations. Numerical simulations are used to validate the derived expression and experiments are performed on an agar gel model and normal brain. Experimental agar data indicate that direct saturation of the liquid component can be a major source of signal attenuation whereas MT normally dominates in brain tissue. The signal equation presented here establishes the necessary theory for sequence design and optimization and provides insight into model parameters and experimental results.

Agar↗

Magnetization transfer magnetic resonance imaging: a clinical review.

Magnetic resonance imaging has traditionally used the T1 and T2 relaxation times and proton density (PD) of tissue water (hydrogen protons) to manipulate contrast. Magnetization transfer (MT) is a new form of tissue contrast based on the physical concept that tissues contain two or more separate populations of hydrogen protons: a highly mobile (free) hydrogen (water) pool, Hr, and an immobile (restricted) hydrogen pool, Hr, the latter being those protons bound to large macromolecular proteins and lipids, such as those found in such cellular membranes as myelin. Direct observation of the Hr magnetization pool is normally not possible because of its extremely short T2 time (< 200 microseconds). But saturation of the restricted pool will have a detectable effect on the mobile (free) proton pool. Saturation of the restricted pool decreases the signal of the free pool by transferring the restricted pool's saturation. Exchange of magnetization between the free and restricted hydrogen protons is a substantial mechanism for spin-lattice (T1) relaxation in tissues and the physical basis of MT. Through an appropriately designed pulse sequence, magnetization transfer contrast (MTC) can be produced. MT contrast is different from T1, T2, and PD, and it likely reflects the structural integrity of the tissue being imaged. A variety of clinically important uses of MT have emerged. In this clinical review of the neuroradiological applications of MT, we briefly review the physics of MT, the appearance of normal brain with MT, and the use of MT as a method of contrast enhancement/background suppression and in tissue characterization, such as evaluation of multiple sclerosis and other white-matter lesions and tumors. The role of MT in small-vessel visualization on three-dimensional time-of-flight magnetic resonance angiography and in head and neck disease and newer applications of MT are also elaborated.

Brain↗

Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio.

We describe a technique to increase the velocity-to-noise ratio (VNR) of phase-contrast magnetic-resonance velocity images based on making three measurements/flow encoding axis rather than the usual two. A phase-aliased high first moment data set and a nonaliased low first moment data set are acquired, and the high-moment data are phase unwrapped using the low-moment data. The VNR of the resulting measurement is given by that of the high-moment measurement and increases linearly with the first moment. A factor of 4 gain in VNR was observed with only a 50% increase in scan time. Thus, this method is a much more efficient way to increase VNR than simple averaging.

Cerebrospinal Fluid↗

Magnetization transfer contrast MRI of musculoskeletal neoplasms.

Magnetic resonance imaging (MRI) examinations were performed in 15 patients with musculoskeletal neoplasms to assess the value of magnetization transfer contrast in tumor characterization. Multiplanar gradient-recalled echo sequences (TR 500-600/TE 15-20/flip angle 20-30 degrees) were performed first without and then with magnetization transfer contrast generated by a zero degree binomial pulse (MPGR and MTMPGR). Standard T1-weighted spin echo images (SE; TR 300-400/TE 12-20) and either T2-weighted SE (TR 2000-2900/TE 70-80) or T2-weighted fast spin echo (FSE; TR 4000-5000/TE 100-119 effective) images were also obtained. Signal intensities on MTMPGR scans were compared to those on MPGR scans for both tumors and normal tissues. Signal intensity ratios (SIR) and contrast-to-noise ratios (CNR) were also compared for all sequences. MTMPGR images provided better contrast between pathologic tissues and muscle than did standard MPGR images, increasing both conspicuity of lesions and definition of tumor/muscle interfaces. Benign and malignant tumors, with the exception of lipoma, underwent similar degrees of magnetization transfer and could not be distinguished by this technique.

Adipose Tissue↗

Central nervous system tumor, infection, and infarction: detection with gadolinium-enhanced magnetization transfer MR imaging.

PURPOSE: To quantitatively measure the degree of contrast enhancement of central nervous system (CNS) tumor, infection, and infarction by means of magnetization transfer (MT) magnetic resonance (MR) imaging. MATERIALS AND METHODS: T1-weighted MR images obtained before and after administration of contrast material with and without MT in 14 patients with CNS tumors were evaluated by means of a contrast-to-noise ratio (C/N). Another 72 patients with a variety of lesions underwent contrast material-enhanced T1-weighted MR imaging prospectively with and without MT; C/N was also evaluated. RESULTS: All lesions had a higher C/N on T1-weighted postcontrast MT images than on conventional images. C/N was 65 +/- 5 (mean +/- standard error) for MT and 42 +/- 4 for conventional images. C/N improved by a factor of 1.6-2.1 in the three disease categories. In intracranial tumors, the MT technique itself did not contribute significantly (P < .001) to the increase in C/N in the absence of gadopentetate dimeglumine. In fact, the C/N was lower for nonenhanced T1-weighted MT images. CONCLUSION: Concurrent use of gadopentetate dimeglumine and MT results in a statistically significant (P < .001) increase in C/N in CNS tumor, infection, and infarction.

Adult↗

Improved detection of enhancing and nonenhancing lesions of multiple sclerosis with magnetization transfer.

PURPOSE: To determine whether magnetization transfer imaging can improve visibility of contrast enhancement of multiple sclerosis plaques. METHODS: Fifty-nine enhancing and 63 nonenhancing lesions in 10 patients with multiple sclerosis were evaluated to calculate contrast-to-noise ratios on conventional T1-weighted and T1-weighted magnetization transfer images. The signal intensity of the lesion and the background (white matter) were measured on precontrast T1-weighted and T1-weighted magnetization transfer images (800/20/1 [repetition time/echo time/excitations]) and on postcontrast T1-weighted and T1-weighted magnetization transfer images. Mean contrast-to-noise ratios was calculated for all lesions. RESULTS: The contrast-to-noise ratio was significantly higher for enhancing and nonenhancing lesions on T1-weighted magnetization transfer images than on conventional T1-weighted images. For enhancing lesions, the contrast-to-noise ratio was significantly higher on postcontrast T1-weighted magnetization transfer images, 32 +/- 2 compared with 21 +/- 2 on conventional T1-weighted images. Fifty of the 59 enhancing lesions were seen on both the T1-weighted and the T1-weighted magnetization transfer images. Nine enhancing lesions were seen only on the postcontrast T1-weighted magnetization transfer images. In addition, of 63 nonenhancing lesions seen on proton-density, T2-weighted, and T1-weighted magnetization transfer images, 16 were not seen on the conventional T1-weighted images. Seven of the 63 nonenhancing lesions and 7 of the 59 enhancing lesions had high signal intensity on the precontrast T1-weighted magnetization transfer images suggestive of lipid signal, a finding not seen on the conventional precontrast T1-weighted images. CONCLUSION: Magnetization transfer improves the visibility of enhancing multiple sclerosis lesions, because they have a higher contrast-to-noise ratio than conventional postcontrast T1-weighted images. High signal intensity on both nonenhancing and enhancing lesions noted only on precontrast T1-weighted magnetization transfer suggests a lipid signal was unmasked. If magnetization transfer is used in multiple sclerosis patients, a precontrast magnetization transfer image is necessary.

Adult↗

Magnetic resonance velocity imaging using a fast spiral phase contrast sequence.

Time-resolved velocity imaging using the magnetic resonance phase contrast technique can provide clinically important quantitative flow measurements in vivo but suffers from long scan times when based on conventional spin-warp sequences. This can be particularly problematic when imaging regions of the abdomen and thorax because of respiratory motion. We present a rapid phase contrast sequence based on an interleaved spiral k-space data acquisition that permits time-resolved, three-direction velocity imaging within a breath-hold. Results of steady and pulsatile flow phantom experiments are presented, which indicate excellent agreement between our technique and through plane flow measurements made with an in-line ultrasound probe. Also shown are results of normal volunteer studies of the carotids, renal arteries, and heart.

Blood Flow Velocity↗

Magnetization transfer time-of-flight magnetic resonance angiography.

Time-of-flight (TOF) angiography based on inflow enhancement is limited by the steady-state signal differences between blood and the surrounding stationary tissues. We present a new TOF sequence in which magnetization transfer contrast is used to supplement wash-in effects. Angiograms demonstrating the superior performance of this technique are presented.

Blood Vessels↗

Three-dimensional display of cortical anatomy and vasculature: magnetic resonance angiography versus multimodality integration.

We present two methods for acquiring and viewing integrated three-dimensional (3D) images of cerebral vasculature and cortical anatomy. The aim of each technique is to provide the neurosurgeon or radiologist with a 3D image containing information which cannot ordinarily be obtained from a single imaging modality. The first approach employs recent developments in MR which is now capable of imaging flowing blood as well as static tissue. Here, true 3D data are acquired and displayed using volume or surface rendering techniques. The second approach is based on the integration of x-ray projection angiograms and tomographic image data, allowing a composite image of anatomy and vasculature to be viewed in 3D. This is accomplished by superimposing an angiographic stereo-pair onto volume rendered images of either CT or MR data created with matched viewing geometries. The two approaches are outlined and compared. Results are presented for each technique and potential clinical applications discussed.

Brain↗

Radiosurgery with photon beams: physical aspects and adequacy of linear accelerators.

The question of the adequacy of isocentric linear accelerators (linacs) for use in radiosurgery is addressed. The general physical requirements for radiosurgery, mainly a high spatial and numerical accuracy of dose delivery, reasonable treatment time, and low skin and leakage dose as well as cost considerations are examined. Various linac-based procedures are analyzed in view of their ability to meet these requirements and are contrasted with the clinically proven system of the Gamma unit. It is shown that the linac-based multiple converging arcs techniques and the dynamic rotation meet the stringent physical requirements on dose delivery and are thus viable alternatives to radiosurgery with the commercially available and dedicated Gamma unit.

Costs and Cost Analysis↗

Radiosurgery of cerebral arteriovenous malformations with the dynamic stereotactic irradiation.

From December 1986 through December 1988, 33 patients with inoperable arteriovenous malformation (AVM) were treated in our center with the dynamic stereotactic radiosurgery, which uses a standard 10 MV isocentric linear accelerator. There were 18 females and 15 males with a median age of 26 years (range: 9-69) and a median follow-up time of 16 months (range: 7-32). The arteriovenous malformation volumes treated ranged from 0.2 to 42 cm3. The prescribed doses at the isocenter varied from 50 to 55 Gy and were given as a single fraction in the majority of the patients (31/33). Late complications consisting of intracranial bleeding and/or hemiparesis were observed in three patients. To date, 21 patients underwent repeat angiographic studies at 1 year post-treatment. A complete obliteration of the lesion was achieved in 38% of these patients. For the patients whose arteriovenous malformation nidus was covered by a minimum dose of 25 Gy, the total obliteration rate was 61.5% (8/13), whereas none of the patients who had received less than 25 Gy at the edge of the nidus obtained a total obliteration. Our preliminary analysis at 1 year post-radiosurgery reveals results comparable to those previously reported for other radiosurgical techniques for the same follow-up period.

Adolescent↗

Integration of stereoscopic DSA with three-dimensional image reconstruction for stereotactic planning.

Following 4 years of experience using a microcomputer-based system for the planning of stereotactic neurosurgery, we have now developed a workstation with the capability of displaying and analyzing three-dimensional images for this purpose. In addition to viewing volumetrically rendered three-dimensional computer tomograms and magnetic resonance images, we may directly view and analyze stereoscopic digital angiograms. In addition to each set of images being viewed in isolation, we may also combine the three-dimensional anatomical images with the stereoscopic angiograms. This new system is based on a computer equipped with a light polarization switched screen capable of displaying stereoscopic images directly to the observer, thus permitting him to interact with the three-dimensional volume directly, determining coordinates and positioning probe trajectories.

Angiography, Digital Subtraction↗