Search PubMed⌕ Search

Biomedical subjects

G B Lund

Publications and source records attributed to G B Lund.

42 records · Page 3Linked to original sources

Biliary manometry versus clinical trial: value as predictors of success after treatment of biliary tract strictures.

PURPOSE: To evaluate the biliary manometric-perfusion test (BMPT) and clinical trial as predictors of long-term success after percutaneous and surgical treatment of biliary tract strictures. PATIENTS AND METHODS: After percutaneous intervention or surgical repair of extrahepatic bile duct strictures, 43 patients underwent long-term biliary intubation (mean, 13 months) with 61 internal-external stents. Before removal of the stents, all 43 patients underwent a BMPT (n = 65) and 24 underwent a 2-3-week clinical trial (n = 27) with stents positioned above the treated region. Patients were followed up 1-46 months (mean, 16 months) after stent removal, with clinical outcome determined by means of physical examination, biochemical evaluation, chart review, and telephone interview. RESULTS: With logistic regression analysis, the BMPT and clinical trial were shown to have equal predictive value in determining treatment success or failure. Eighty-four percent of the clinical outcomes were correctly predicted with BMPT, versus 88% for the clinical trial. Kaplan-Meier survival curve analysis demonstrated the probability of remaining stricture free at 1 year after passing a BMPT and after passing a clinical trial to be 90% and 86% (P = .55), respectively. CONCLUSION: BMPT and clinical trial have similar capabilities in the prediction of long-term patency after treatment of benign biliary tract strictures, but the BMPT is less costly and time consuming for the patient.

Anastomosis, Roux-en-Y↗

Intraductal biliary biopsy: comparison of three techniques.

PURPOSE: To compare the results obtained with three different techniques for percutaneous transhepatic intraductal biopsy. MATERIALS AND METHODS: Eighty-eight patients with obstructive jaundice underwent placement of percutaneous biliary drainage catheters for biliary decompression. As part of the initial procedure or at a subsequent date, intraductal biliary biopsy (n = 109) was performed with use of one or more of three techniques including cytologic brush (n = 53), clamshell forceps under choledochoscopic guidance (n = 31), and clamshell forceps under fluoroscopic guidance (n = 25). RESULTS: Forty-eight patients (55%) had a final diagnosis of malignant disease, and 40 (45%) had a diagnosis of benign disease. One hundred six (97%) biopsy procedures yielded technically adequate specimens. No complications directly related to the biopsy procedures occurred. Overall sensitivity and specificity for each biopsy technique were 26% and 96% for the cytologic brush technique, 30% and 88% for the clamshell forceps under fluoroscopic guidance technique, and 44% and 100% for the clamshell forceps under choledochoscopic guidance technique, respectively. The sensitivities of the biopsy techniques for pancreatic carcinoma and cholangiocarcinoma, respectively, were 47% and 0% for brush; 75% and 0% for fluoroscopic clamshell; and 100% and 27% for choledochoscopic clamshell. CONCLUSION: The choledochoscope-directed biopsy technique had the greatest sensitivity and specificity of the three techniques evaluated, but this difference was not statistically significant versus the brush or fluoroscopic clamshell technique (P > .10). The sensitivity of all three techniques for pancreatic carcinoma was significantly greater than that for cholangiocarcinoma. Multiple biopsies did not increase the overall sensitivity of intraductal biliary biopsy as a diagnostic technique. All three techniques proved to be safe and easy to perform.

Adolescent↗

Volumetric evaluation of blood flow in normal renal arteries with a Doppler flow wire: a feasibility study.

PURPOSE: To evaluate the feasibility of direct intravascular determination of renal artery (RA) blood flow with a Doppler probetipped guide wire. MATERIALS AND METHODS: Potential renal donors (n = 10) with normal RAs (n = 23) underwent evaluation of RA blood flow velocity with use of a 0.018-inch, 12-MHz Doppler guide wire. The RA average peak velocity (APV) was obtained with the flow wire. RA diameter was obtained from the filmed images with magnification corrected to a known standard or by a computerized quantification program. These data were used to determine the vessel's cross-sectional area (CSA). RESULTS: The right and left RA APV, CSA, and blood flow differed insignificantly within the group and averaged 9.7 and 9.0 cm/sec (P = .43), 0.417 and 0.357 cm2 (P = .22), and 382 and 370 mL/min (P = .43), respectively. However, in individuals, the RA CSA and total volumetric blood flow varied by a mean of 29% (range, 4%-56%) and 50% (range, 19%-128%), respectively. CONCLUSION: This study demonstrates that direct intravascular determination of RA blood flow with a Doppler-tipped wire is both feasible and relatively uncomplicated. Results indicate that blood flow can vary significantly, both in kidneys within the same individual and from person to person. The Doppler wire may facilitate measurements of RA blood flow during endoluminal interventions and help determine an optimal endpoint for these procedures.

Adult↗

The biliary manometric perfusion test and clinical trial--long-term predictive value of success after treatment of bile duct strictures: ten-year experience.

PURPOSE: To evaluate the long-term predictive value of the biliary manometric perfusion test and clinical trial for determining patency after treatment of bile duct strictures. MATERIALS AND METHODS: One hundred four patients with benign biliary disease were treated with surgical (n = 59) or percutaneous (n = 45) techniques followed by intubation with large-caliber silicone stents. Prior to removal of the biliary stents, patients underwent a biliary manometric perfusion test (n = 168) and/or a clinical trial (n = 105) to objectively and subjectively evaluate the treated site for potential long-term patency. The patients were followed up for 1-87 months, and clinical outcomes were determined. Kaplan-Meier survival curves were generated for three patient groups, including those who (i) passed either test, (ii) failed either test, and (iii) failed either test, were re-treated, and passed either test. RESULTS: Final successful treatment outcomes were documented in 47 (92%) surgically and 31 (86%) percutaneously treated patients, respectively (P = .001). The Kaplan-Meier survival curves determined the probability of patency at 0, 2, 4, and 6 years after treatment to be 1.0, .96, .78, and .59, respectively, after passing a biliary manometric perfusion test; and 1.0, .91, .78, and .78, respectively, after passing a clinical trial (P > .10). The probability of patency at 4 years after treatment was .45 after failing a biliary manometric perfusion test, and at 6 months was zero after failing a clinical trial (P = .001 and .001, respectively, vs the same test in the passing group). Seventy-nine percent of patients who failed either test required an additional period of repeated stent placement or reoperation. After repeated treatment, the probability of patency at 0-4 years was .80 and .88, respectively, for the biliary manometric perfusion test and clinical trial (P > .05 and P > .10, respectively, vs same test in the group that passed). CONCLUSION: Patients who initially pass either the biliary manometric perfusion test or clinical trial have a significantly increased probability of patency versus those who fail; however, patients who fail either test and who then receive definitive additional treatment have a similar probability of patency as those who initially pass. Although the log rank test demonstrated the Kaplan-Meier survival curves from the biliary manometric perfusion test and clinical trial not to be significantly different in any of the three groups (ie, passing, failing, re-treated), the biliary manometric perfusion test is recommended over the clinical trial because of its simplicity, immediate results, and predicted cost savings.

Adult↗

Translumbar inferior vena cava catheters: safety and efficacy in peripheral blood stem cell transplantation.

Most patients who need peripheral blood stem cell transplantation do not have peripheral venous access that would allow apheresis for stem cell collection. Subclavian apheresis catheters have an unacceptably high incidence of thrombosis-related access failure. A technique has been developed for translumbar placement of permanent, subcutaneously tunneled, silicone rubber apheresis catheters into the inferior vena cava, and 40 of these catheters have been placed in 36 patients for stem cell collection. Twenty-six catheters have been left in place for venous access during the transplantation procedure. These catheters had a very low rate (2.3%) of apheresis-related related complications. Access failure was attributed to thrombosis in 10 catheters (25%) and to mechanical complications in another 9 (22%), but access was regained in all but 4 of these cases. The catheters functioned well as venous access devices during transplantation, only rarely developing complications during that time. Venograms performed at the time of removal of 16 catheters showed no case of caval occlusion. A residual fibrin sheath was found around 14 catheters. There was no clinical or computed tomographic scan evidence of bleeding after placement or removal of the catheters. Percutaneously placed, translumbar inferior vena cava apheresis catheters provide a safe and effective route for the collection of peripheral blood stem cells for transplantation, and they can be left in place for venous access during transplantation.

Catheterization, Peripheral↗