Search PubMed⌕ Search

Biomedical subjects

G Annat

Publications and source records attributed to G Annat.

At least 37 records · Page 2Linked to original sources

Recovery of [13C]bicarbonate as respiratory 13CO2 in mechanically ventilated patients.

Measurement of the nutrient oxidation rate with 13C as a tracer requires knowledge of the value of its coefficient of fractional recovery in the expired gas (FR). We measured FR in nine intensive care patients who were mechanically ventilated and received total parenteral nutrition. NaH13CO3 was administered at a priming dose (3.75 mumol.kg-1.min-1) followed by a continuous infusion (0.05 mumol.kg-1.min-1). Metabolic rate and pulmonary carbon dioxide elimination (VCO2) were measured by using a mass-spectrometer system. The 13C-12C ratio was measured in the expired gas with an isotopic-ratio mass spectrometer and FR was calculated by using standard equations. The average value of FR was 0.899 +/- 0.026 (means +/- SE) and remained stable for each patient on 2 consecutive days. Between patients, the coefficient of variation of FR was 8.6%. Metabolic rate was the only physiological factor found to affect the FR value.

Adolescent↗

Spontaneous baroreflex by sequence and power spectral methods in humans.

Beat-by-beat variations in blood pressure and RR-interval are interrelated by the actions of baroreflex and non-baroreflex responses. This study had two purposes: (1) to examine the spontaneous relationships between RR-interval and systolic blood pressure to determine the relative occurrence of baroreflex and non-baroreflex responses in humans, and (2) to compare the beat-sequence method with a cross spectral estimate of the baroreflex response slope. Eight healthy men were studied during 10 h of quiet, seated rest, and six men and three women were studied during rest, rest plus fixed pace breathing, and a cold pressor test. RR-interval and continuous, non-invasive arterial blood pressure were measured with a computerized system. A baroreflex sequence was defined by a series of at least three consecutive heart beats in which systolic pressure and the following RR-interval either both increased or both decreased. A non-baroreflex relationship was defined by sequences of at least three beats by opposite directional changes of RR-interval and systolic pressure of that beat. The results showed that there were approximately 30% as many non-baroreflex compared to baroreflex slopes. Individual subject mean baroreflex and non-baroreflex slopes were highly correlated (r = 0.72, P < 0.001). Absolute slope values were not different, and they were unaffected by time, fixed pace breathing, or cold pressor test. The data showed the relatively simple beat-by-beat sequence method to yield spontaneous baroreflex response slopes that were quantitatively similar to, and highly correlated with (r = 0.85-0.94), baroreflex response slopes calculated by spectral analysis methods.

Adult↗

Oxygen uptake after major abdominal surgery: effect of clonidine.

To examine the effect of an alpha-2 agonist, clonidine, on oxygen uptake and on the incidence of postoperative shivering, 28 patients presenting for major abdominal surgery were randomly assigned in a double-blind manner to one of two groups. Intraoperatively, 14 patients received 5 micrograms.kg-1 clonidine infused over 3 h (clonidine group), and 14 patients received placebo (placebo group). Oxygen uptake was measured continuously over the first 3 postoperative hours with a mass spectrometer system. Circulatory variables, esophageal temperature, and skin temperature were measured over the first 6 postoperative hours. Heart rate, mean arterial pressure, rate pressure product, and norepinephrine concentration were decreased in the clonidine group (P less than 2 x 10(-4)). There were no differences among groups in the incidence of shivering and in the rate of increase of esophageal temperature. By contrast, oxygen uptake was lower in the clonidine group (P = 4 x 10(-4)). This contrasting pattern may be secondary to a reduction in the intensity of mean muscular tremor in the clonidine group.

Adjuvants, Anesthesia↗

The effects of norepinephrine infusion on oxygen consumption in a patient with septic shock.

A 65-year-old man developed postsurgical septic shock, unresponsive to plasma volume expansion and administration of dopamine and dobutamine. A continuous norepinephrine infusion was then started and the dose increased to 0.62 micrograms.kg-1.min-1 until the mean arterial pressure was 70 mmHg. Prior to and during the norepinephrine infusion, oxygen consumption was continuously measured with a mass spectrometer system. There was a parallel increase in mean arterial pressure and oxygen consumption (+ 35%). There was also an increase in cardiac index and oxygen delivery. Systemic vascular resistance was only transiently increased. In this case with septic shock, norepinephrine infusion improved hemodynamic variables with an associated increase in oxygen consumption.

Aged↗

[Measurement of gas exchange in anesthesia and during resuscitation: principles and applications].

Pulmonary gas exchange measurements can be performed in ICU with commercially available devices. During open-circuit anaesthesia, measurement of VO2 and VCO2 requires the acquisition of fractional concentration of inspired and expired nitrogen, the appropriate calibration of sensors according to the use of anaesthetic gases and to take into account the unsteady state of nitrogen body stores after a change in FiN2. This technique can be readily used to measure energetic expenditure or to specific applications as oxygen cost of breathing, respiratory effects of parenteral nutrition or the metabolic effects of various anaesthetic procedures in man.

Anesthesia↗

Effects of protein intake on pulmonary gas exchange and ventilatory drive in postoperative patients.

The effects of different protein regimens on pulmonary gas exchange and ventilatory drive were examined in eight postoperative patients receiving inspiratory pressure support ventilation. They were studied during 60 consecutive hours, which included two 12-h periods of high protein intake (33%) of total caloric intake provided as protein), each of them being preceded and followed by a 12-h period of standard protein intake (14% of total caloric intake provided as protein). Throughout the study, total caloric intake was 1.5 times the predicted resting energy expenditure. Nitrogen was provided as a 24% branched chain amino acid (BCAA) solution during the period of standard protein intake. During the periods of high protein intake, it was provided as a 24% and a 41% BCAA solution. Pulmonary gas exchange was continuously measured during the second half of each period, with the use of a mass spectrometer system. Measurements of the ventilatory response to CO2 (FICO2 0, 1.5, and 3%) were achieved at the end of each dietary regimen. O2 consumption, CO2 production, respiratory quotient, minute ventilation, and PaCO2 were the same for the three protein regimens. Changing protein intake failed to affect the ventilatory response to CO2. The authors conclude that, in postoperative patients having inspiratory pressure support ventilation, the administration of a high protein intake does not affect the ventilatory drive and the pulmonary gas exchange.

Carbon Dioxide↗

Continuous measurement of pulmonary gas exchange during general anaesthesia in man.

We report a system for the continuous measurement of oxygen uptake (VO2) and carbon dioxide output (VCO2) during open-circuit anaesthesia. Gas concentrations were measured by a mass-spectrometer, and expired flow by a pneumotachograph. The values measured by the system were compared in vitro to values produced by a nitrogen-dilution technique. Excellent correlations were found. Continuous measurements were performed in 21 patients anaesthetized for abdominal surgery. Compared to pure intravenous anaesthesia (flunitrazepam-fentanyl), anaesthesia including the administration of nitrous oxide or nitrous oxide and halothane led to more pronounced and sustained decreases in VO2 and core temperature, with a better cardiovascular stability. Two hours postoperatively, VO2 was not different from preoperative values. After a transient increase at the onset of anaesthesia, the respiratory exchange ratio (VCO2/VO2) returned to preoperative values, and then remained subsequently unchanged. Based on these observations, the system described provides an accurate approach to noninvasively monitoring the pulmonary gas exchange in the operating room.

Aged↗

Energy expenditure in the acute renal failure patient mechanically ventilated.

Twenty mechanically ventilated patients with acute renal failure were studied on 31 occasions to determine their energy expenditure (EE) during a 2 h period before a hemodialysis. Oxygen consumption and CO2 elimination were measured continuously with a mass spectrometer system. EE (1660 +/- 48 kcal day-1) was close to the total caloric intake (1682 +/- 83 kcal day-1) and represented 1.19 +/- 0.03 times the predicted resting energy expenditure (PREE) with large inter-individual variations (0.7-1.7 PREE). EE/PREE was higher when sepsis was present (1.31 +/- 0.03 versus 1.14 +/- 0.02; p less than 0.05). Glucose oxidation rate (4.35 mg kg-1 min-1) exceeded glucose intake (2.6 mg kg-1 min-1). Respiratory quotient was 1.02 +/- 0.01. Nitrogen loss was 17.3 +/- 1.7 g day-1 and nitrogen balance -11.9 +/- 1.9 g day-1. In conclusion, EE values were scattered but never exceeded 1.7 times the PREE. Sepsis increased EE. With a nutritional support covering EE, nitrogen balance remained markedly negative and a preferential utilisation of glucose and lipogenesis occurred.

Acute Kidney Injury↗

Added inspiratory work of breathing during CPAP ventilation: comparison of two demand-valve devices with a continuous flow-system.

Measurements of added inspiratory work (AIW) of breathing imposed by three different CPAP systems were performed in 10 patients. One system was a continuous flow system while the two others were demand flow systems separated from respirators (Ohmeda VD 101 and Draeger CPAP 800 devices). AIW was calculated from pressure and flow signals recorded at the mouthpiece level. The AIW calculated with the two demand-flow systems was found to be the same as the AIW calculated with the continuous flow system although the results obtained by the Draeger device were less constant. The results obtained with the Ohmeda device in our patients conflicted with data previously published using a lung model.

Acute Disease↗

Plasma vasopressin, neurophysin, renin and aldosterone during a 4-day head-down bed rest with and without exercise.

The purpose of this study was to investigate the main renal and hormonal responses to head-down bed rest, which is currently considered a reliable experimental model for the simulation of weightlessness. Urinary output and electrolytes, plasma renin activity (PRA), aldosterone (PA), antidiuretic hormone (ADH) and immunoreactive neurophysin-I (Np) were measured in eight adult volunteers submitted to a 4-day head-down bed rest (-6 degrees) after a 24-h control period in the horizontal position (day 0). Four of the eight subjects were submitted to two 1-h periods of controlled muscular exercise (50% VO2max) from day 1 to day 4. Throughout the head-down bed rest period, urinary output remained stable, although lower than in the control period (day 0), but the urinary Na/K ratio decreased. Plasma electrolytes and osmolality, and creatinine clearance remained unchanged. There was no significant difference between exercising and non-exercising subjects. At the hormonal level, PRA and PA increased during the head-down bed rest. This increase was more pronounced in the group with exercise. At the end of the tilt period, PRA and PA were about 3 times higher than on day 1. No significant changes could be observed for ADH and Np. It is concluded that a 4-day head-down bed rest results in no apparent changes in neurohypophyseal secretory activity, and in a progressive secondary hyperaldosteronism.

Adult↗

[Continuous measurement of gas exchange during artificial ventilation].

A system for on-line measurement of respiratory gas exchange in patients undergoing artificial ventilation is described. Fractional concentrations were measured by a mass spectrometer and expired flow by a pneumotachometer; signals processing was carried out by a microcomputer. The accuracy of the measurement of the burning methanol RQ was within 1.6% at FIO2 lower or equal to 0.4. When compared to a reference method (the Douglas bag method), correlation was found to be excellent. The major problem in measuring gas exchange in a ventilated patient is that physiological signals are contaminated by artefacts which may lead to erroneous computations. An algorithm was developed in order to identify and disregard artefacted periods or ventilatory unsteady state in the patients. The technique used for data processing gave reliable continuous measurements of respiratory gas exchange for periods up to 24 h, without interfering with the nursing of the ventilated patients.

Algorithms↗