Search PubMed⌕ Search

Biomedical subjects

G Adam

Publications and source records attributed to G Adam.

At least 19 recordsLinked to original sources

[Patterns of delayed-enhancement in MRI of ischemic and non-ischemic cardiomyopathies].

Contrast-enhanced MRI using the delayed-enhancement technique (DE-MRI) is widely applied in the clinical work-up of myocardial diseases. Myocardial diseases of varying etiology result in myocardial changes, such as necrosis, fibrosis, edema and metabolite deposition, which can be visualized by DE-MRI. Acute and chronic ischemic diseases based on a coronary artery disease as well as non-ischemic cardiomyopathies display DE. Cardiomyopathies often show a characteristic enhancement pattern. While ischemic lesions are localized in the subendocardium, non-ischemic cardiomyopathies often display an intramyocardial or subepicardial pattern. The typical pattern for dilated cardiomyopathies is band-like and intramyocardial with septal involvement. Arrhythmogenic right-ventricular dysplasias/cardiomyopathies are frequently associated with right-ventricular DE. In the case of amyloid cardiomyopathies which are often restrictive cardiomyopathies, subendocardial and circular DE is typically observed. Hypertrophic cardiomyopathies display patchy intramyocardial DE usually in the anteroseptal region. Acute myocarditis is typically accompanied by intramyocardial or subepicardial DE affecting the lateral wall. In the case of chronic myocarditis, intramyocardial or subepicardial DE is observed most frequently. Cardiac sarcoidosis typically entails patchy subepicardial DE with right- and left-ventricular involvement. Since there is an overlap between the enhancement patterns of cardiomyopathies, the diagnostic accuracy of DE-MRI is limited and the diagnosis must be based on additional clinical and MRI findings. The amount of DE often corresponds with cardiac functional parameters as well as with the frequency of cardiac events so that DE-MRI may be useful for risk stratification. Furthermore, DE-MRI can be helpful in the planning and evaluation of myocardial biopsies and electrophysiological examinations.

Acute Disease↗

Detection of small pulmonary nodules in high-field MR at 3 T: evaluation of different pulse sequences using porcine lung explants.

To evaluate two MR imaging sequences for the detection of artificial pulmonary nodules inside porcine lung explants. 67 agarose nodules ranging 3-20 mm were injected into ten porcine lungs within a dedicated chest phantom. The signal on T1-weighted images and radiopacity were adjusted by adding 0.125 mmol/l Gd-DTPA and 1.5 g/l of iodine. A T1-weighted three-dimensional gradient-echo (T1-3D-GRE; TR/TE:3.3/1.1 ms, slice:8 mm, flip-angle:10 degrees ) and a T2-weighted half-Fourier fast-spin echo sequence (T2-HF-FSE; TR/TE:2000/66 ms, slice:7 mm, flip-angle:90 degrees ) were applied in axial orientation using a 3-T system (Intera, Philips Medical Systems, Best, The Netherlands), followed by CT (16x0.5 mm) as reference. Nodule sizes and locations were assessed by three blinded observers. In nodules of >10 mm, sensitivity was 100% using 3D-GRE-MRI and 94% using the HF-FSE sequence. For nodules 6-10 mm, the sensitivity of MRI was lower than with CT (3D-GRE:92%; T2-HF-FSE:83%). In lesions smaller than 5 mm, the sensitivity declined to 80% (3D-GRE) and 53% (HF-FSE). Small lesion diameters were overestimated with both sequences, particularly with HF-FSE. This study confirms the feasibility of 3 T-MRI for lung nodule detection. In lesions greater than 5 mm, the sensitivity of the 3D-GRE sequence approximated CT (>90%), while sensitivity and PPV with the HF-FSE sequence were slightly inferior.

Animals↗

Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems.

The objective of this paper is to evaluate magnetic field interactions at 1.5 and 3 T for 20 orthodontic devices used for fixed orthodontic therapy. Twenty springs and auxiliary parts made from varying ferromagnetic alloys were tested for magnetic field interactions in the static magnetic field at 1.5 and 3 T. Magnetic translational force F(z) (in millinewtons) was evaluated by determining the deflection angle beta [American Society for Testing and Materials (ASTM standard test method)]. Magnetic-field-induced rotational force F(rot) was qualitatively determined using a five-point scale. beta was found to be >45 degrees in 13(15) devices at 1.5(3) T and translational force F(z) exceeded gravitational force F(g) on the particular object [F(z) 10.17-261.4 mN (10.72-566.4 mN) at 1.5(3) T]. F(z) was found to be up to 24.1(47.5)-fold higher than F(g) at 1.5(3) T. Corresponding to this, F(rot) on the objects was shown to be high at both field strengths (> or = +3). Three objects (at 1.5 T) and one object (at 3 T) showed deflection angles <45 degrees , but F(rot) was found to be > or = +3 at both field strengths. For the remaining objects, beta was below 45 degrees and torque measurements ranged from 0 to +2. Of 20 objects investigated for magnetic field interactions at 1.5(3) T, 13(15) were unsafe in magnetic resonance (MR), based on the ASTM criteria of F(z). The implications of these results for orthodontic patients undergoing MRI are discussed.

Electromagnetic Fields↗

[Multislice CT urography (MSCTU): evaluation of a modified scan protocol for optimized opacification of the collecting system].

PURPOSE: To retrospectively quantify opacification of the urinary tract using a MSCTU protocol based on furosemide and individual adaptation of urographic acquisition delay. MATERIALS AND METHODS: MSCTU examinations obtained from 4-row and 16-row CT scanners in 53 patients (35 men, 18 women, average age 59) were independently reviewed by two radiologists. MSCTUs were performed using a low-dose injection of furosemide. No fixed scan delay for urographic image acquisition was applied. The urographic timing was individually adapted by performing low-dose test images of the distal ureters to display their current opacification. Image analysis included grading of the opacification of the segmented collecting system. The average urographic delay was calculated. Stratified comparisons of mean scores were assessed using the Friedman and Wilcoxon tests. The inter-observer kappa value was calculated. RESULTS: The calculated median scan delay for patients with normal serum-creatinine levels (n = 51) was 418 sec (mean 447 sec; SD, 118 sec). The median number of acquired test images was 2 (range 1 - 6 images). The opacification analysis demonstrated that 98 % of the ICS, 90 % of the proximal, 86 % of the middle, and 83 % of the distal ureteral segments showed opacification greater than 90 %. 9.5 % of the distal ureteral segments could not be visualized. Statistics did not show significant opacification differences between proximal, middle, and distal ureteral segments (p > 0.05). The two observers were largely in agreement (kappa coefficient r = 0.81). CONCLUSION: The analyzed MSCTU technique based on furosemide and scan delay timing by means of test images reliably lead to a homogenous opacification of the entire upper urinary tract. It features the individual adaptation of MSCTU to the excretory rate of the kidneys.

Adolescent↗

[Economic evaluation of angiographic interventions including a whole-radiology in- and outpatient care].

PURPOSE: To determine the economic efficiency of a whole-radiology in- and outpatient treatment with angiographic interventions performed as the main or sole therapy. MATERIALS AND METHODS: The calculations represent the data of a university radiology department, including the following angiographic interventions (neuroradiology not considered): Vascular intervention (PTA, stent implantation) of kidneys and extremities, recanalization of hemodialysis access, chemoembolization, diagnostic arterioportal liver CT, port implantation, varicocele embolization, PTCD, percutaneous implantation of biliary stent. First, the different angiographic interventions are categorized with reference to the German DRG system 2005. Considering the example of a university hospital, the individual cost of each intervention is calculated and correlated with reimbursements by G-DRG2005 and so-called "ambulant operation" (EBM200plus). With these data, profits and losses are calculated for both in- and outpatient care. RESULTS: Radiologic interventions of inpatients yield a profit in the majority of cases. With a base rate of 2900 euros, the profits in our university hospital range between - 872 euros and + 3411 euros (mean: + 1348 euros). On the other hand, those angiographic interventions suitable for "ambulant operation" generate average profits of + 372 euros, if only direct costs are considered. The data of outpatient radiological interventions average between 381 euros up to 1612 euros lower than compared with profits obtained from in patient care. CONCLUSION: Once an angiographic intervention represents the major or sole therapy, German radiologists are advised to operate out- and inpatient care by themselves. In Germany, the G-DRG-system and EBM enable radiology departments to generate considerable proceeds for their hospitals and, secondly, to yield a valuable add-on profit for their own department budget, which then is partly detached from the inflexible conventional reimbursement of radiological services.

Angiography↗

[Functional imaging of submandibular glands: diffusion-weighted echo-planar MRI before and after stimulation].

PURPOSE: To investigate the feasibility of diffusion-weighted (DWI) echo-planar imaging (EPI) to depict the submandibular glands and to measure different functional conditions. MATERIALS AND METHODS: Twenty-seven healthy volunteers were examined. Diffusion weighted sequence was performed prior to stimulation. Exactly 30 seconds after a commercially available lemon juice was given orally, the diffusion weighted sequence was repeated. All examinations were performed by using a 1.5-T superconducting system with a 30 mT/m maximum gradient capability and maximum slew rate of 125 mT/m/sec (Magnetom Symphony, Siemens, Erlangen, Germany). The lower part of the circularly polarized (CP) head coil and a standard two-element CP neck array coil were used. The flexibility of the neck array coil allowed positioning the N1 element (upper part of the coil) right next to the submandibular gland. The axial diffusion-weighted EPI (echo planar imaging) sequence was performed using a matrix of 119 x 128, a field of view of 250 x 250 mm (pixel size 2.1 x 1.95 mm), a section thickness of 5 mm with an interslice gap of 1 mm. The b factors used were 0 sec/mm(2), 500 sec/ mm(2) and 1000 sec/mm(2). Apparent diffusion coefficiant (ADC) maps were digitally transferred to MRIcro (Chris Rorden, Universitiy of Nottingham, Great Britain). After detecting the submandibular glands a region of interest (ROI) was placed manually exactly within the boarder of both submandibular glands, excluding the external carotid artery on ADC maps. These procedures were performed on all ADC slices the submandibular glands could be differentiated in before and after oral stimulation. For statistical comparison of results, a student's t-test was performed with an overall two-tailed significance level of p = 0.05. RESULTS: The visualization of the submandibular glands using the diffusion-weighted EPI sequence was possible in all of the 27 volunteers. Prior to oral stimulation an ADC of 1.31 x 10(-3) mm(2)/sec (95 % CI, 1.39 x 10(-3) mm(2)/sec, 1.44 x 10(-3) mm(2)/sec) was calculated which increased to 1.41 x 10(-3) mm(2)/sec (95 % KI, 1.39 x 10(- 3) mm(2)/sec, 1.44 x 10(-3) mm(2)/sec) 30 seconds after stimulation. This increase proved to be significant (p < 0.001). CONCLUSION: Diffusion-weighted echo-planar MR imaging allows non-invasive quantification of functional changes in the submandibular gland.

Adult↗

[16-Row multidetector CT of the pelvis after iliosacrally inserted osteosynthetic screws: experimental study of dose adjustment on preserved human cadaver specimens].

PURPOSE: The study was performed to assess the necessity of dose adjustment (kV or mAs (eff.)) in 16-slice CT (MDCT) in postoperative controls of iliosacrally inserted osteosynthetic screws (OS) on preserved human cadaver specimens. The minimal tube settings for diagnostic imaging of the pelvic bone were analyzed and the effective doses and important organ doses were calculated. MATERIALS AND METHODS: 16 preserved human cadaver specimens with transiliac osteosynthetic screws were scanned on a 16-slice CT (collimation 16 x 0.75 mm, pitch 0.7) with 10 different tube settings (35, 50, 75, 100, 150 mAs (eff.) and 120 and 140 kV). 32 datasets (blinded for name and scan parameters) with and without OS were independently evaluated by four observers. The 10 series were sorted by subjective image quality (image noise, contours, artifacts), and the series with the lowest but still diagnostic quality was selected. The statistical analysis included multi-rater-kappa-test and Wilcoxon test for paired samples. RESULTS: The multi-reader agreements for sorting the series were fair (kappa = 0.38). The agreements in comparing the lowest diagnostic image qualities were slight to fair (kappa = 0.08-0.23). The paired sample test comparing the lowest diagnostic image quality with and without OS showed no statistical significance (p = 0.29). 87.5 % of the readouts (n = 64 [16 examinations, 4 readers]) with OS and 78.1 % of those without OS could be adequately diagnosed using the three series with the lowest effective doses (0.9-1.4 mSv for men, 1.4-2.0 mSv for women; 120 kV-35 mAs (eff.), 120-50, 140-35). CONCLUSION: MSCT scans of the pelvic bone can be performed with very low effective doses. It is not necessary to adjust tube settings when imaging bones with osteosynthetic screws. If the concept for the control of the pelvic osteosynthetic screw position includes more than 2 conventional films (for example anterioposterior view with additional inlet and outlet views), a low dose CT is preferable to conventional radiography.

Animals↗

[Modern diagnostic assessment of the upper urinary tract using multislice CT urography].

The advent of Multislice Computed Tomography (MSCT) has made evaluation of the entire urinary tract with high-resolution sections during a single breath-hold a reality. Acquisition of multiple thin overlapping slices provides excellent two-dimensional (2D) and three-dimensional (3D) reformations of the urinary tract. The concept of "Multislice CT Urography (MSCTU)" has emerged from this technical improvement. As a result, a wide range of pathologies inside and outside the urinary tract can be identified. During the last several years, MSCTU has challenged intravenous urography (IVU) in the evaluation of urinary tract abnormalities. Compared with IVU, MSCT(U) is more sensitive and specific in the detection and characterization of a variety of urinary tract disorders, including renal masses and urolithiasis. The main advantage of IVU has been its ability to offer excellent delineation of pelvicalyceal and ureteral anatomy and to depict subtle uroepithelial abnormalities. MSCTU has already shown promising results for overcoming this challenge. Optimal opacification and distension appear to be an essential requirement for a thorough evaluation of the collecting system. Dedicated preparation strategies have been developed to meet these technical difficulties. The biggest disadvantage of MSCTU is the significant radiation exposure. For broad routine clinical application, there is still a need for dose reduction protocols despite the ongoing technical developments in MSCTU. In this article, we outline the different concepts of technical processing for MSCTU and summarize the current role of MSCTU in the evaluation of the upper urinary tract.

Carcinoma, Transitional Cell↗

Experimental 16-row CT evaluation of in-stent restenosis using new stationary and moving cardiac stent phantoms: experimental examination.

PURPOSE: The aim of this study was to evaluate in-stent restenosiss using a newly developed stationary and moving cardiac stent phantom with three built-in artificial stenoses and a 16-row MDCT. MATERIALS AND METHODS: A newly developed coronary stent phantom with three artificial stenoses--low (approx. 30 %), medium (approx. 50 %) and high (approx. 70 %)--was attached to a moving heart phantom and used to evaluate the ability of 16-row MDCT to visualize in-stent restenosis. High resolution scans (16 x 0.75 mm, 250 mm FOV) were made to identify the baseline for image quality. The non-moving phantom was scanned (16 x 0.75 mm, routine cardiac scan protocol) first without and then with implementation of an ECG signal at various simulated heart rates (HR 40 to 120 bpm) and pitches (0.15 to 0.3). The moving cardiac phantom was scanned at the same simulated heart rates but at a pitch of 0.15. Images were reconstructed at every 10 % of the RR interval using a multi-cycle real cone-beam reconstruction algorithm. Multi-planar reformations (MPR) were made for the image evaluation. The image quality was assessed using a three-point scale, and stent patency and stenoses detection were evaluated using a four-point scale. To evaluate the image quality and to grade the stent stenoses, the median values were calculated while considering the reconstruction interval. RESULTS: The image quality for the static phantom was adequate in 97 % of the measurements. In this phantom, every stenosis was detected independent of the pitch and heart rate used. The dynamic stent phantom yielded the best results at 0 %, 40 %, and 50 % of the RR interval at a pitch of 0.15. The low stenosis was visible at a simulated heart rate of up to 80 bpm. Patency can be detected at heart rates greater than 80 bpm. CONCLUSION: The newly developed moving stent phantom allowed a nearly in-vivo condition for detecting re-stenoses within a stent. In this phantom study the use of a 16-row MDCT allowed the detection of re-stenosis within a coronary stent at a heart rate of up to 80 bpm. This phantom can then be used for future studies, e. g. with a 64-row MDCT.

Artifacts↗

In vitro investigations on the differential pro-oxidant and/or antioxidant properties of cyclosporin A and tacrolimus in human and rat liver microsomes.

OBJECTIVE: The use of cyclosporin A (CSA) and tacrolimus (TAC) in organ transplantation and in the therapy of immune disorders is often hampered by adverse effects, mainly nephro-, hepato- and neurotoxicity. For the development of these side effects, among others, an increased formation of reactive oxygen species, probably generated by the cytochrome P450 (CYP) system, has been accused. Since in this respect literature data are inconsistent, in the present study possible pro- and/or antioxidant effects of CSA and TAC and the involvement of the CYP system were re-evaluated in vitro. METHODS: Effects of CSA and TAC were examined on CYP mediated oxidase functions by stimulated lipid peroxidation (LPO), H2O2 production, and lucigenin (LC) or luminol (LM) amplified chemiluminescence (CL) in liver microsomes of either untreated rats or of rats treated with beta-naphthoflavone (BNF), phenobarbital (PB) or dexamethasone (DEX) and in human liver microsomes. RESULTS: In rat liver microsomes, CSA displayed pro-oxidant properties (though only very slightly), whereas in human liver microsomes small antioxidant effects were seen. With TAC in both species the antioxidant capacity prevailed. Treatment of rats with BNF or DEX caused an increase in the pro-oxidant effects of CSA with respect to LPO or LM-CL, whereas in liver microsomes of DEX-treated rats H2O2 production and LC-CL were diminished. CONCLUSIONS: CSA seems to have both pro-oxidant and antioxidant properties, whereas with TAC mainly an antioxidant capacity was seen. The CYP system seems to be involved in the pro-oxidant influence of CSA. Whether pro-oxidant or antioxidant effects predominate may depend on the antioxidant capacity of a tissue and on the CYP isoforms mainly present.

Animals↗

[The French Red Cross: a network of care centers dedicated to HIV-AIDS].

The commitment of the French Red Cross Society to the fight against HIV/AIDS in Africa and Asia is based on day care centers (DCC) set up and operated within public hospitals. These outpatient facilities offer global care including clinical and biologic follow-up for patients undergoing anti-retroviral treatment. In most countries these DCC have become reference centers providing support for national decentralization policies. To reinforce the impact of their activities, centers offer regular educational programs and provide extensive training for medical personnel.

Acquired Immunodeficiency Syndrome↗

The phylogenetic structure of the cluster of tobamovirus species serologically related to ribgrass mosaic virus (RMV) and the sequence of streptocarpus flower break virus (SFBV).

Ribgrass mosaic virus (RMV), turnip vein-clearing virus (TVCV) and Youcai mosaic virus (YoMV; formerly designated as oilseed rape mosaic virus; ORMV) belong to the genus Tobamovirus and are arranged in one out of three subgroups because of their common host range, serological cross-reactivity and amino acid composition of their coat proteins. The recently defined species Wasabi mottle virus (WMoV) is closely related to the same subgroup. The distinction of the four species is difficult and the lack of sequence information of a wide range of isolates has led to an unclear nomenclature. To clarify this situation we sequenced the coat protein genes from 18 isolates which were serologically related to members of the species of this cluster. The size of the coat protein was conserved with the exception of one isolate which revealed an N-terminal extension due to the mutation of three stop-codons. Phylogenetic analysis of these CP ORFs resulted in a tree with three clusters each containing at least one of the approved species RMV, TVCV and 1ptYoMV/WMoV in which our isolates were distributed. The tree was congruent and did support the present taxonomic status of species within this subgroup. For practical purpose we developed a subgroup 3 specific primer pair and a species differentiating restriction fragment length polymorphism (RFLP). Sequencing of the genome of Streptocarpus flower break virus (SFBV) which is serologically distantly related to the subgroup 3 viruses revealed a distinct genome organization. Therefore we propose that this virus should be regarded as a member of a species not belonging to any of the subgroups so far established.

Base Sequence↗

Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.

Currently there are few data available regarding the application and efficacy of computer-assisted procedures in the sacral spine. In order to optimize and standardize this procedure, a controlled experimental investigation has been performed. The aim of the study is to systematically assess the efficacy of a novel three-dimensional image intensifier used for navigated transiliac screw insertion into the first sacral vertebra. Screws were inserted iliosacrally into the first sacral vertebra of preserved human cadaver specimens. The instrument navigated procedure was performed with the "Siremobil Iso-C(3D) " (Siemens Medical Solutions) and the "Navigation System" by Stryker. The accuracy and quality of the imaging procedure as well as the fluoroscopic exposure times were measured. These results were compared to three control groups (CT-based navigation, C-arm navigation, and fluoroscopic guidance). In each group a total amount of 20 screws was implanted. Screw position was postoperatively assessed by Iso-C(3D) or CT-scan. The navigated procedure using the Iso-C(3D) provided good feasibility characteristics without requiring a specific matching process. It revealed the shortest procedure time of all navigated procedures and significantly decreased fluoroscopic time compared to C-arm navigation and fluoroscopic guidance. Furthermore, Iso-C(3D) navigation showed no screw malposition and was in this regard superior to C-arm navigated and fluoroscopic guided procedures. The quality of imaging was sufficient for accurate placement, but did not share the high-resolution level of CT-based navigation. These findings indicate that application of the Iso-C(3D) for navigated transiliac screw insertion into S1 can be recommended as a feasible and safe technique, enabling the surgeon to reduce procedure and fluoroscopic time. Further progress in improving the quality of the Iso-C(3D) image should be attempted.

Bone Screws↗

Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom.

Measurements of spatial and temporal resolution for ECG-gated scanning of a stationary and moving heart phantom with a 16-row MDCT were performed. A resolution phantom with cylindrical holes from 0.4 to 3.0 mm diameter was mounted to a cardiac phantom, which simulates the motion of a beating heart. Data acquisition was performed with 16x0.75 mm at various heart rates (HR, 60-120 bpm), pitches (0.15-0.30) and scanner rotation times (RT, 0.42 and 0.50 s). Raw data were reconstructed using a multi-cycle real cone-beam reconstruction algorithm at multiple phases of the RR interval. Multi-planar reformations (MPR) were generated and analyzed. Temporal resolution and cardiac cycles used for image reconstruction were calculated. In 97.2% (243/250) of data obtained with the stationary phantom, the complete row of holes with 0.6 mm was visible. These results were independent of heart rate, pitch, scanner rotation time and phase point of reconstruction. For the dynamic phantom, spatial resolution was determined during phases of minimal motion (116/250). In 40.5% (47/116), the resolution was 0.6 mm and in 37.1% (43/116) 0.7 mm. Temporal resolution varied between 63 and 205 ms, using 1.5-4.37 cardiac cycles for image reconstruction.

Electrocardiography↗

[Multislice CT urography Aspects for technical management and clinical application].

The introduction of multislice computed tomography with its well-known advantages has made it possible to visualize the entire urinary tract with thin collimation during a breath-holding phase. CT data acquisition during urographic contrast enhancement for contiguous imaging of the entire upper urinary tract is termed "multislice CT urography" (MSCTU). Multiplanar reconstructions, maximum intensity projections, and average intensity projections can be rendered from the volume datasets to view the urogenital tract. MSCTU will play an important role in the future of modern uroradiology. This article describes the technical aspects involved in the course of the MSCTU examination and identifies additional potential indications for clinical application.

Anatomy, Cross-Sectional↗

[Calcium scoring and coronary angiography performed with multislice spiral CT -- clinical experience].

PURPOSE: To report our clinical experience in calcium scoring and coronary angiography with multislice computer tomography (MSCT). MATERIAL AND METHODS: Cardiac four-row MSCT (Siemens, Volume Zoom, Erlangen, Germany) was performed in 60 patients, comprising 45 patients without known coronary vessel disease (CVD) and falling in an intermediate risk (group I) by calcium scoring, and 15 patients with multivessel disease by the combination of calcium scoring and MSCT coronary angiography (group II). Group I underwent analysis of risk factors as well as patient management in the form of risk profile modulation, indication for invasive selective coronary angiography (SCA) and supplemental myocardial diagnostic evaluation (e. g., SPECT). Agatston and volume scores (Virtuoso, Siemens, Erlangen, Germany) were calculated for calcium scoring. Group II had the calcium scoring and diagnostic accuracy of MSCT in detecting coronary artery stenosis evaluated according to established American Heart Association (AHA) criteria. SCA was used as gold standard. RESULTS: In group I, calcium scoring was positive in 27/45 (60 %) patients, with 14/27 (52 %) consecutively referred to SCA and 2/27 (7 %) to SPECT. SCA revealed significant coronary stenosis (> 60 %) in 5/27 (19 %) patients and SPECT detected myocardial ischemia in 0/2 patients. Patients with obstructive coronary vessel disease showed a significantly increased calcium score of > 300 together with a high risk profile. Patients with negative calcium score showed significantly less risk factors (p < 0.05). The use of calcium scoring in therapeutic procedures in the form of increased modulation of risk factors was documented in 21/45 (47 %) patients. In group II, sensitivity, specificity and diagnostic accuracy for the detection of high grade coronary artery stenosis were 64 %, 99 % and 96 %, and the Agatston and Volume scores were 333 +/- 123 and 334 +/- 136, respectively. CONCLUSION: MSCT can be applied as risk profile module for coronary screening of patients with intermediate risk. As non-invasive alternative for the evaluation of coronary vessel disease, it can be useful in some cases by providing additional information.

Adult↗

[Dose optimization for multislice computed tomography protocols of the midface].

PURPOSE: To optimize multislice computed tomography (MSCT) protocols of the midface for dose reduction and adequate image quality. MATERIALS AND METHODS: MSCT (Somatom Volume Zoom, Siemens) of the midface was performed on 3 cadavers within 24 hours of death with successive reduction of the tube current, applying 150, 100, 70 and 30 mAs at 120 kV as well as 40 and 21 mAs at 80 kV. At 120 kV, a pitch of 0.875 and collimation of 4x1 mm were used, and at 80 kV, a pitch of 0.7 and collimation of 2x0.5 mm. Images were reconstructed in transverse and coronal orientation. Qualitative image analysis was separately performed by two radiologists using a five-point scale (1 = excellent; 5 = poor) applying the following parameters: image quality, demarcation and sharpness of lamellar bone, overall image quality, and image noise (1 = minor; 5 = strong). The effective body dose [mSv] and organ dose [mSv] of the ocular lens (using the dosimetry system "WINdose") were calculated, and the interobserver agreement (kappa coefficient) was determined. RESULTS: For the evaluation of the lamellar bone, adequate sharpness, demarcation and image quality was demonstrated at 120 kV/30 mAs, and for the overall image quality and noise, 120 kV/40 mAs was acceptable. With regard to image quality, the effective body dose could be reduced from 1.89 mSv to 0.34 mSv and the organ dose of the ocular lens from 27.2 mSv to 4.8 mSv. Interobserver agreement was moderate (kappa = 0.39). CONCLUSION: Adequate image quality was achieved for MSCT protocols of the midface with 30 mAs at 120 kV, resulting in a dose reduction of 70 % in comparison to standard protocols.

Face↗

[MR-sialography: optimisation and evaluation of an ultra-fast sequence in parallel acquisition technique and different functional conditions of salivary glands].

PURPOSE: To optimise a fast sequence for MR-sialography and to compare a parallel and non-parallel acquisition technique. Additionally, the effect of oral stimulation regarding the image quality was evaluated. MATERIAL AND METHODS: All examinations were performed by using a 1.5-T superconducting system. After developing a sufficient sequence for MR-sialography, a single-shot turbo-spin-echo sequence (ss-TSE) with an acquisition time of 2.8 sec was used in transverse and oblique sagittal orientation in 27 healthy volunteers. All images were performed with and without parallel imaging technique. The assessment of the ductal system of the submandibular and parotid gland was performed using a 1 to 5 visual scale for each side separately. Images were evaluated by four independent experienced radiologists. For statistical evaluation, an ANOVA with post-hoc comparisons was used with an overall two-tailed significance level of P =.05. For evaluation of interobserver variability, an intraclass correlation was computed and correlation >.08 was determined to indicate a high correlation. RESULTS: All parts of salivary excretal ducts could be visualised in all volunteers, with an overall rating for all ducts of 2.26 (SD +/- 1.09). Between the four observers a high correlation could be obtained with an intraclass correlation of 0.9475. A significant influence regarding the slice angulations could not be obtained (p = 0.74). In all healthy volunteers the visibility of excretory ducts improved significantly after oral application of a Sialogogum (p < 0.001; eta (2) = 0.049). The use of a parallel imaging technique did not lead to an improvement of visualisation, showing a significant loss of image quality compared to an acquisition technique without parallel imaging (p < 0.001; eta (2) = 0.013). CONCLUSION: The optimised ss-TSE MR-sialography seems to be a fast and sufficient technique for visualisation of excretory ducts of the main salivary glands, with no elaborate post-processing needed. To improve results of MR-sialography, it is reasonable to use an oral Sialogogum.

Computing Methodologies↗