Search PubMed⌕ Search

Biomedical subjects

G A Wright

Publications and source records attributed to G A Wright.

At least 37 records · Page 2Linked to original sources

Effects of a thirteen-week inhalation exposure to ethyl tertiary butyl ether on fischer-344 rats and CD-1 mice.

The 1990 Clean Air Act Amendments require that oxygenates be added to automotive fuels to reduce emissions of carbon monoxide and hydrocarbons. One potential oxygenate is the aliphatic ether ethyl tertiary butyl ether (ETBE). Our objective was to provide data on the potential toxic effects of ETBE. Male and female Fisher 344 rats and CD-1 mice were exposed to 0 (control), 500, 1750, or 5000 ppm of ETBE for 6 h/day and 5 days/wk over a 13-week period. ETBE exposure had no effect on mortality and body weight with the exception of an increase in body weights of the female rats in the 5000-ppm group. No major changes in clinical pathology parameters were noted for either rats or mice exposed to ETBE for 6 (rats only) or 13 weeks. Liver weights increased with increasing ETBE-exposure concentration for both sexes of rats and mice. Increases in kidney, adrenal, and heart (females only) weights were noted in rats. Degenerative changes in testicular seminiferous tubules were observed in male rats exposed to 1750 and 5000 ppm but were not seen in mice. This testicular lesion has not been reported previously for aliphatic ethers. Increases in the incidence of regenerative foci, rates of renal cell proliferation, and alpha2u-globulin containing protein droplets were noted in the kidneys of all treated male rats. These lesions are associated with the male rat-specific syndrome of alpha2u-globulin nephropathy. Increases in the incidence of centrilobular hepatocyte hypertrophy and rates of hepatocyte cell proliferation were seen in the livers of male and female mice in the 5000-ppm group, consistent with a mitogenic response to ETBE. These two target organs for ETBE toxicity, mouse liver and male rat kidney, have also been reported for methyl tertiary butyl ether and unleaded gasoline.

Administration, Inhalation↗

Water dynamics in human blood via combined measurements of T2 relaxation and diffusion in the presence of gadolinium.

An analytical model of tissue relaxation and restricted diffusion in human blood is presented. The blood tissue model is composed of three different compartments: red blood cells, plasma, and macromolecular protons. The relaxation rate constants and free diffusion coefficients of intracellular and extracellular water may differ. Analytical formulas for signal loss due to relaxation and diffusion in the Carr-Purcell Meiboom-Gill and pulsed-field-gradient multispin echo experiments for this tissue model are derived. The model is fitted to the experimental data for human blood with various concentrations of Gadolinium contrast agent. The obtained model parameters are realistic. The validity and sensitivity of the model are also discussed.

Blood↗

Partial volume effects on vascular T2 measurements.

Quantitative, vascular T2 measurements are of interest for applications such as MR oximetry. In the situation of a vessel with long T2 relaxation times embedded in tissue with relatively short T2 values, contamination of the blood signal from the surrounding tissue can bias T2 measurements. Limited data sampling and vessels running obliquely through the imaging slice can cause significant signal contamination. Using a model of these effects to predict the behavior of T2 measurements under a range of conditions, a set of parameters that provides the best combination of measurement accuracy with a signal-to-noise ratio as high as possible is proposed.

Artifacts↗

Design of practical T2-selective RF excitation (TELEX) pulses.

Traditional T2-based imaging techniques are geared toward imaging long-T2 species. Traditional techniques are, therefore, not optimal in clinical situations where the information of interest lies in the short-T2 species. T2-selective RF excitation (TELEX) is a technique for obtaining a T2-based contrast that highlights short-T2 values while suppressing long-T2 values-opposite to traditional T2 contrast. Previously, TELEX has been demonstrated qualitatively to highlight only very short-T2 values (T2 approximately 0.001 s). When applied to longer T2 values (T2 > or = 0.01 s), TELEX becomes sensitive to deltaB0 non-uniformities. This restricts its application to problems in which the T2 of interest is very short. In this study, TELEX is characterized quantitatively. Furthermore, a bandwidth broadening scheme is developed that reduces the deltaB0 sensitivity of TELEX. This permits the technique to be applied to longer T2 values. The capabilities and limitations of a practical implementation of TELEX are discussed.

Humans↗

Mesenteric ischemia due to hemorrhagic shock: MR imaging diagnosis and monitoring in a canine model.

PURPOSE: To test whether changes in the percentage of oxygenated hemoglobin (%HbO2) and blood flow in the superior mesenteric vein (SMV), as measured with magnetic resonance (MR) imaging in vivo, can be used to diagnose and monitor mesenteric ischemia due to hemorrhagic shock in a canine model. MATERIALS AND METHODS: Eight mongrel dogs (weight range, 20-30 kg) underwent fasting for 24 hours before the experiments. MR imaging measurements of SMV %HbO2 and volume flow rate were obtained at the resting state and after 5%, 10%, and 15% of the blood volume of the dogs had been removed sequentially, which led to a total blood volume depletion of 30%. In four dogs, resuscitation was performed with normal saline solution in a volume equal to the total volume of blood removed. RESULTS: SMV %HbO2 and SMV flow measurements at the different stages of blood removal were all significantly different (P < .05) from baseline measurements and from each other. After volume replacement with normal saline solution, SMV %HbO2 and flow were not significantly different (P > .05) from the baseline values. CONCLUSION: SMV %HbO2 and volume flow rate, as measured with MR imaging in vivo, can be used to diagnose and monitor mesenteric ischemia due to hemorrhagic shock in a canine model.

Animals↗

Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography.

At magnetic resonance angiography in nine patients, a test bolus of gadopentetate dimeglumine was injected to determine transit time from venous injection to arrival in the carotid arteries. Mean times to onset of enhancement were calculated (arterial, 15.7 seconds [range, 10-22 seconds]; venous, 23.4 seconds [range, 16-30 seconds]; optimal imaging time, 7.78 seconds [range, 6-10 seconds]). Transit time was calculated correctly with a test bolus examination.

Aged↗

Dermal absorption and pharmacokinetics of isopropanol in the male and female F-344 rat.

Isopropanol (IPA), as a 70% aqueous solution, was applied under occluded conditions to the shaved backs of male and female Fischer F-344 rats for a period of 4 hr. Maximum analyzed blood concentrations of IPA were attained at 4 hr and decreased steadily following removal of the test material. Blood concentrations were below the limit of quantification at 8 hr. Acetone (ACE) blood levels rose steadily during the 4-hr exposures and continued to rise following removal of the test material, reaching peak analyzed levels at 4.5 hr (male) and 5 hr (females). ACE blood concentrations were below the limit of quantification at 24 hr. Basic pharmacokinetic parameters were similar for male and female rats with mean, first-order elimination half-lives for IPA and ACE of 0.8 to 0.9 hr and 2.1 to 2.2 hr, respectively. Following iv administration of [14C]IPA, 50-55% of the dose was eliminated as 14CO2 with lesser amounts recovered as expired volatiles or in urine. Total recoveries following iv administration were 83% for both males and females. Following a 4-hr dermal exposure to [14C]IPA (70% aqueous solution), 84-86% of the dose was recovered from the application site. Dermal absorption rates were calculated by two independent methods. The values obtained were 0.78 +/- 0.03 and 0.85 +/- 0.04 mg/cm2/hr for males and 0.77 +/- 0.13 and 0.78 +/- 0.16 mg/cm2/hr for females. Calculated permeability coefficients of 1.37 to 1.50 x 10(-3) cm/hr for males and 1.35 to 1.37 x 10(-3) cm/hr for females indicate that in the rat, IPA is rapidly absorbed dermally when applied under occluded conditions.

2-Propanol↗

An analytical model of restricted diffusion in bovine optic nerve.

An analytical model of restricted diffusion in bovine optic nerve is presented. The nerve tissue model is composed of two different objects: prolate ellipsoids (axons) and spheres (glial cells) surrounded by partially permeable membranes. The free diffusion coefficients of intracellular and extracellular water may differ. Analytical formulas for signal loss due to diffusion in the pulsed gradient spin echo (PGSE) experiment for this tissue model are derived. The model is fitted to experimental data for bovine optic nerve. The obtained model parameters are shown to be reasonable. The model describes all of the characteristics of the PGSE data: anisotropy, upward curvature of decay curves, and diffusion time dependence. The validity and sensitivity of the model are also discussed.

Animals↗

Three-dimensional flow-independent peripheral angiography.

A magnetization-prepared sequence, T2-Prep-IR, exploits T1, T2, and chemical shift differences to suppress background tissues relative to arterial blood. The resulting flow-independent angiograms depict vessels with any orientation and flow velocity. No extrinsic contrast agent is required. Muscle is the dominant source of background signal in normal volunteers. However, long-T2 deep venous blood and nonvascular fluids such as edema also contribute background signal in some patients. Three sets of imaging parameters are described to address patient-specific contrast requirements. A rapid, spiral-based, three-dimensional readout is utilized to generate high-resolution angiograms of the lower extremities. Comparisons with x-ray angiography and two-dimensional time-of-flight angiography indicate that this flow-independent technique has unique capabilities to accurately depict stenoses and to visualize slow flow and in-plane vessels.

Angiography↗

T2 accuracy on a whole-body imager.

MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends to be overestimated due to temporary storage of the magnetization along the longitudinal axis where it decays more slowly with a time constant T1 > T2. To reduce the T1 dependence while preventing signal loss, we utilize simple 90x180y90x composite pulses and good RF cycling patterns. These trains are critical for T2 accuracy over typical ranges of RF and static field inhomogeneities and refocusing intervals. T1 signal decay during each 90x180y90x pulse must be accounted for to yield accuracy within 5% when the pulse-width is 10% or more of the refocusing interval. A simple correction scheme compensates for this T1-related error effectively.

Humans↗

In vivo magnetic resonance evaluation of blood oxygen saturation in the superior mesenteric vein as a measure of the degree of acute flow reduction in the superior mesenteric artery: findings in a canine model.

RATIONALE AND OBJECTIVES: The authors tested the hypothesis that changes in oxygen saturation (%HbO2) in the superior mesenteric vein (SMV), as measured with in vivo magnetic resonance (MR) oximetry, correlate with the degree of acute superior mesenteric artery (SMA) flow reduction. METHODS: Ten mongrel dogs were studied. A catheter was inserted into the SMV, and a perivascular ultrasonic flow probe and an adjustable mechanical occluder were placed around the SMA. MR oximetry was carried out at the resting state and after the SMA was constricted to predetermined levels (0%-75% of initial flow). In seven dogs, SMV blood samples were obtained immediately before and after each MR measurement; %HbO2 was measured simultaneously by using an oximeter. With linear regression analysis, the SMV %HbO2 measurements obtained at MR imaging were compared with those obtained at oximetry. With a logistic model, MR imaging changes in SMV %HbO2 were compared with the degree of SMA flow reduction. RESULTS: SMV %HbO2 measurements obtained with MR imaging correlated well with those obtained with oximetry (r = .97). Changes in SMV %HbO2 measured at MR imaging also correlated well with the degree of SMA flow reduction, as determined with a logistic model (P = .01). CONCLUSION: Noninvasive in vivo MR measurements of SMV %HbO2 can be used to determine the degree of acute SMA flow reduction with a high degree of accuracy in a canine model.

Animals↗

Correlation of radionuclide and optical tracer assessments of fluid flow in artificial ventricles.

Characterization of flow properties of an artificial ventricle may aid development of designs to minimize thrombosis. Techniques for determining two such flow properties, viz. ventricular clearance rate and ejection fraction, are compared and validated here for polyurethane and silicone rubber ventricles operated in a mock circulatory loop at various stroke volumes and pulse rates. Ventricular clearance rats were measured both by clinical radionuclide tracer techniques and by an optical tracer method. Ejection fractions were measured by radionuclide imaging and validated by direct measurements of flow rate and ventricular volume. Results from the two methods for ventricular clearance are in close agreement. The optical tracer method is superior in spatial resolution, convenience and economy, but the radionuclide tracer method for ejection fraction gives excellent agreement with the absolute measurements.

Animals↗

Chronic mesenteric ischemia: use of in vivo MR imaging measurements of blood oxygen saturation in the superior mesenteric vein for diagnosis.

PURPOSE: To determine if dogs and humans with chronic mesenteric ischemia demonstrate a decrease in the percentage of oxygenated hemoglobin (%HbO2) in the superior mesenteric vein (SMV) after a meal. MATERIALS AND METHODS: In 10 dogs, ameroid rings were surgically implanted around the superior mesenteric arteries to create gradual stenosis. Pre- and postoperative angiograms and pre- and postprandial magnetic resonance (MR) oximetry measurements of the SMV %HbO2, with flow-independent T2 measurements of venous blood, were obtained at different times. In 10 patients with atherosclerotic disease and six patients with symptomatic chronic mesenteric ischemia, the same measurements were obtained after at least 6 hours of fasting and at 15, 35, and 45 minutes after ingestion of a liquid nutritional supplement. RESULTS: In seven dogs, the postprandial SMV %HbO2 increased an average of 2.5% +/- 0.8 before surgery and decreased an average of 6.3% +/- 2.1 when hemodynamically significant (>70%) stenosis of the superior mesenteric artery developed 7-14 days after surgery. In the 10 patients without ischemia, the SMV %HbO2 increased by 4.6% +/- 0.6, whereas in the symptomatic patients a postprandial decrease of 8.8% +/- 0.7 occurred (P < .0001). CONCLUSION: Measurement of the SMV %HbO2 with MR oximetry is a promising test for diagnosis of chronic mesenteric ischemia.

Adult↗

Isopropanol: summary of TSCA test rule studies and relevance to hazard identification.

The toxicity of isopropanol (IPA) has been extensively studied as a result of a Test Rule under Section 4 of the Toxic Substances Control Act. In general, the data showed that IPA has a low order of acute and chronic toxicity; does not produce adverse effects on reproduction; is neither a teratogen, a selective developmental toxicant, nor a developmental neurotoxicant; and is not genotoxic or an animal carcinogen. IPA is, however, a potential hazard for transient central nervous system depression at high exposure levels. In addition, IPA produced effects to several rodent toxicity endpoints at high dose levels (i.e., motor activity, male mating index, and exacerbated renal disease) which are of unclear relevance to human health. The data generated by these studies confirmed that IPA acts as a typical short-chain alcohol in mammalian biological systems. It produces a significant narcotic effect upon exposure at high levels for extended periods of time, with no irreversible effects even after repeated exposure, which is consistent with other short-chain alcohols. The metabolism of IPA appears equivalent across species with rapid conversion to acetone and carbon dioxide. Overall, these studies demonstrate IPA exposure is a low potential hazard to human health. This information will allow for an improved assessment of the human health risks from IPA exposure.

1-Propanol↗

Coronary angiography with magnetization-prepared T2 contrast.

A magnetization-prepared, T2-weighted sequence (T2 Prep) is used to suppress muscle and venous structures. When combined with lipid suppression, this technique improves the visualization of the coronary arteries. T2 Prep was designed to be rebust in the presence of flow as well as B0 and B1 inhomogeneities and may be combined with virtually any imaging technique. Here, it is implemented with both a single-slice spiral acquisition and a multi-slice spiral method that acquires up to 15 slices in a single breath-holding interval.

Arteries↗

Oxygen saturation of blood in the superior mesenteric vein: in vivo verification of MR imaging measurements in a canine model. Work in progress.

PURPOSE: To evaluate the accuracy of magnetic resonance (MR) imaging in estimating oxygen saturation of blood (%HbO2) in the superior mesenteric vein (SMV) of a canine model in vivo. MATERIALS AND METHODS: MR imaging was used to measure the T2 of blood in samples obtained via a catheter placed in the SMV in seven mongrel dogs. %HbO2 was measured with a reflectance oximeter. These measurements were obtained at the resting state, during superior mesenteric artery occlusion, and after reperfusion. MR imaging and oximeter measurements were then compared by using linear regression analysis. RESULTS: Refocusing intervals (tau 180) of 12 and 24 msec were used for 17 and 18 %HbO2 measurements with MR imaging, respectively. With tau 180 of 12 msec, there was an excellent correlation between MR imaging measurements and oximeter measurements (r = .969). The intercept was 5.3% and the slope was 0.959. With tau 180 of 24 msec, r = .953, the intercept was 15.4%, and the slope was 0.817. CONCLUSION: Estimates of %HbO2 in the SMV with MR imaging are accurate in the range of most clinical interest.

Animals↗

Incorporating lactate/lipid discrimination into a spectroscopic imaging sequence.

A spectroscopic imaging sequence incorporating a two-shot lactate editing method was used in two human brain studies to image lactate and NAA. The subtractive editing method allows separate images of lactate, NAA, and lipids to be collected during a single study with no SNR penalty. The sequence uses a spectral-spatial excitation for slice selection and water suppression, and employs inversion recovery and an echo time of 136 ms for additional lipid suppression.

Aspartic Acid↗

Pulsed saturation transfer contrast.

In vivo 1H conventional NMR image contrast generation usually relies on the macroscopic T1 and T2 relaxation parameters of the tissues of interest. Recently cross-relaxation related image contrast has been reported by Wolff and Balaban in animal models. Due primarily to the broad lineshape of the intended saturation spin pool and the use of off-resonance irradiation, high specific absorption rate and an auxiliary RF amplifier have been necessary to produce these images. The relatively long spin-lattice relaxation property of this spin pool, however, suggests the use of pulse methods to achieve saturation. In this paper, we show that short-T2 spin pools can be selectively saturated with short intense RF pulses. Cross-relaxation time constants can be measured using the technique of saturation recovery. In vivo magnetization-transfer-weighted images can be produced using pulses on commercial whole-body imagers without additional hardware.

Adipose Tissue↗