Search PubMed⌕ Search

Biomedical subjects

G A Krombach

Publications and source records attributed to G A Krombach.

At least 19 recordsLinked to original sources

[Necrosis and reconstruction of the inferior oblique muscle after removal of a wooden intra-orbital foreign body].

A 39-year-old patient presented 3 days after a bicycle accident with a progressive left periorbital inflammatory swelling and diplopia in upgaze. On the day of the accident, a cranial x-ray did not reveal a fracture or an orbital foreign body, and the 2.5 cm skin wound on the left lower eyelid was sutured. For further evaluation, computer tomography) was performed. This did not show a radio-opaque, orbital foreign body. An explorative orbitotomy was carried out and revealed a 3.7 cm long wooden fragment medial to the inferior oblique muscle (OI). The extraconal portion of OI was found to be necrotic. Complete reconstruction of the OI was not possible due to the extent of the necrosis. The residual muscle was fixated to the orbital septum. Recovery was good and the diplopia resolved after 6 months. This case emphasizes the importance of a meticulous inspection of skin wounds with a high risk of remaining wooden foreign bodies and shows the possibility of functional recovery of extraocular muscles following partial reconstruction.

Adult↗

[Diagnostic evaluation of chronic inflammatory intestinal diseases in children and adolescents: MRI with true-FISP as new gold standard?].

PURPOSE: To evaluate the impact of magnetic resonance imaging (MRI) with use of True-FISP sequences in the evaluation of inflammatory bowel-wall changes in children and adolescents with Crohn's disease. Furthermore, the diagnostic procedure in children and adolescents with chronic inflammatory bowel disease (IBD) will be discussed in light of the relevant literature. MATERIAL AND METHODS: Twenty-four children and adolescents aged between 7 and 21 years with suspected or known IBD underwent MRI on a 1.5 T-scanner (Philips ACS-NT, Best, Netherlands). One hour after 1 l of a 2.5 % mannitol solution was given orally, MR imaging was performed using coronal HASTE-M2D, coronal fat-suppressed T2-TSE, axial dynamic T1-weighted GE-sequences before and after i. v.-contrast material injection (0.1 mmol/kg Gd-DTPA) and using a 2D-balanced-FFE-sequence (True-FISP) before and after i. v.-contrast material injection in coronal and axial planes. The MR-images were correlated with endoscopy and the clinical findings. In 14 patients, a recently performed conventional radiographic enteroclysis was available. Each performed MRI sequence was evaluated by three experienced radiologists regarding the sensitivity and specificity of each sequence in the detection of inflammatory bowel wall changes. In addition, the image quality was assessed regarding the different tissue contrasts and the susceptibility to artifacts. The distension of the bowel wall and the patients' acceptance of the MRI examination were recorded. RESULTS: With a sensitivity in detecting inflammatory small bowel changes of 93.3 % (axial pre-contrast, coronal post-contrast) and 100 % (axial post-contrast, coronal pre-contrast), the True-FISP outnumbers the other performed sequences (T1 = 80 %, HASTE = 13.3 % and T2-TSE = 53.3 %). The difference between True-FISP and contrast-enhanced T1 was not statistically significant, whereas the difference between True-FISP and HASTE and T2-TSE, respectively, was statistically significant. The True-FISP sequences revealed a statistically significant superiority regarding the soft-tissue differentiation in comparison to all other performed MR-sequences. The distension of the bowel wall was good in all patients. The patients' acceptance of the MRI examination was excellent. CONCLUSION: The described small bowel MRI examination is appropriate for children and adolescents. With the use of True-FISP sequences, it is a convincing method with an outstanding sensitivity in the diagnosis of IBD. Not least because of the lack of radiation exposure, small bowel MRI ought to replace conventional enteroclysis as a gold standard for IBD diagnosis in children and adolescents.

Adolescent↗

[Heart tumors: magnetic resonance imaging and multislice spiral CT].

Transthoracic echocardiography is usually the initial diagnostic test in patients with a suspected cardiac mass. However, this technique is restricted by its small field of views and insufficient acoustic window in some patients. Magnetic resonance imaging (MRI) and, since its introduction, multislice spiral computed tomography allow for detailed delineation of intra and pericardiac tumors, their extent, and their influence on cardiac function. Primary benign and malignant cardiac tumors have several characteristic features in MR imaging. Assessment of such features may narrow down the differential diagnosis or even allow for reliable diagnosis in selected cases. Many such features can also be assessed using MSCT. This article provides an overview of examination protocols of MRI and CT for cases in which a cardiac mass is suspected and describes the appearance of primary and secondary cardiac masses as well as intracavitary thrombi.

Adult↗

Partial percutaneous discectomy for treatment of thoracolumbar disc protrusion: retrospective study of 331 dogs.

OBJECTIVES: To determine retrospectively the prognosis and outcome for dogs diagnosed with thoracolumbar intervertebral disc disease treated with partial percutaneous discectomy (PPD). METHODS: Three hundred and thirty-one dogs presenting with symptoms of thoracolumbar intervertebral disc disease from 1998 to 2003 were treated with PPD. Diagnosis and location of intervertebral disc disease was confirmed by clinical examination, radiography, myelography and magnetic resonance imaging. PPD was performed via fluoroscopy-guided removal of a 5 mm bore cylinder out of the central intervertebral space. RESULTS: Clinical success after surgery was achieved in 159 (88.8 per cent) grade II to IV patients and 58 (38.2 per cent) grade V patients. The mean (sd) time from percutaneous discectomy to first improvement was 8.3 (13.2) days. CLINICAL SIGNIFICANCE: The PPD approach to the thoracolumbar spine involves minor trauma (yielding rapid recovery) and less pain, and produces results comparable with open fenestration. Consequently, this simple minimal invasive technique can be recommended as an alternative to the technique of fenestration and can be easily performed in addition to open surgical decompression techniques or prophylactically. However, it is not a replacement for surgical treatment in dogs with thoracolumbar disc disease that require removal of disc fragments causing spinal cord or nerve root compression.

Animals↗

Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT.

We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence.

Adult↗

[Function tests for the Eustachian tube. Current knowledge].

The Eustachian tube regulates the homeostasis of the middle ear. Problems with its function are predominantly found in childhood. As a consequence, otitis and hearing impairment occur. The most important muscle is the tensor tympani muscle. The complexity of the functional anatomy and physiology are reasons why no function test alone is capable of fulfilling all diagnostic needs. The predictive value of the various Eustachian tube function tests for the outcome of a tympanoplasty is not yet clear. An overview of clinically and scientifically relevant tests for the Eustachian tube function is provided.

Eustachian Tube↗

[Imaging of the abdominal wall: combination of tissue-harmonic-imaging and extended field-of-view sonography].

PURPOSE: To evaluate the combined use of extended field-of-view sonography and tissue harmonic imaging (THI) for assessment of the abdominal wall. MATERIALS AND METHODS: In 32 patients (25 patients without and 7 patients with abdominal wall pathologies) extended field-of-view sonography of the abdominal wall was performed with and without THI using a 7.5 MHz ultrasound transducer. Images with a scan length of 60 cm were acquired above and below the arcuate line. The images were independently assessed by two observers regarding visibility of the anatomic structures and delineation of pathological changes using a 4-point grading scale. Furthermore, the influence of the extent of the subcutaneous fat on the image quality was assessed. For statistical analysis, kappa coefficients, Fisher"s exact test and a repeated measurement analysis of variance (ANOVA) were applied. RESULTS: In all patients, delineation of the abdominal wall was possible with diagnostic image quality. Abdominal wall pathologies were concurrently diagnosed for extended field-of-view sonography with and without utilization of THI. Image quality was rated better with THI when compared to extended field-of-view B-Mode sonography. In comparison to extended field-of-view B-Mode sonography, the agreement between both readers regarding image quality was markedly improved using extended field-of-view sonography in combination with THI. With increasing thickness of the subcutaneous fat layer, image quality was rated significantly better using THI than B-Mode ultrasound. CONCLUSION: Combined use of extended field-of-view sonography and THI improves image quality and documentation of ultrasound examinations. Especially in obese patients, the use of THI is advantageous. Therefore, abdominal wall ultrasound gains additional value in the preoperative planning.

Abdominal Wall↗

[The basics of left ventricular functional analysis with MRI and MSCT].

Over the last few years, cross-sectional imaging became clinically accepted for qualitative and quantitative analysis of left ventricular (LV) function. The results have an impact on diagnosis, therapy and follow-up, and some parameters even proved to be independent predictors of mortality. Besides well established cardiologic techniques, such as ventriculography and echocardiography, more recent radiologic techniques, especially magnetic resonance imaging (MRI) and multislice spiral computed tomography (MSCT), became accepted for imaging of LV function. Assessment of LV function with cardiac MRI is based on cine sequences. Over the last years, parallel imaging techniques, fast imaging with steady state free precession and real time sequences were successfully introduced. Further improvements were achieved by stress examinations and MR-tagging. Cardiac MSCT with retrospective ECG-gating allows for reliable determination of LV volumes. Assessment of wall motion is feasible but limited to some degree. Nevertheless, cardiac MSCT is a powerful alternative for patients with contraindications to MRI. Aim of this article is to review theoretical and technical aspects, opportunities and limitations of MRI and MSCT for functional imaging of the heart.

Adult↗

Multicenter evaluation of a new laser guidance system for computed tomography intervention.

PURPOSE: To measure the accuracy of laser-guided punctures and to evaluate the usefulness of the developed laser-guided system. MATERIAL AND METHODS: The study included 67 patients referred for computed-tomography-guided puncture. The majority of the punctured lesions were located in the chest (28 patients) or abdomen (19 patients). The mean diameter of the lesion was 3.1 cm, and the mean path length was 6.8 cm. The laser guide was movable along a horizontal or vertical rail and not physically connected to the CT unit. The angle of insertion was entered manually into the display of the unit by the interventional radiologist. A prospective multicenter trial was carried out. RESULTS: A mean of 1.1 needle passes were necessary to reach the target, and in 55 (84.6%) of the patients the target was reached on the first needle pass. The mean deviation of the needle from the preselected angle was 1.8 degrees. The mean targeting time (from the initial localizing scan until the needle was in the target) was 15.6 min. In every case, both the usefulness and the ease of use of the laser guidance system were subjectively evaluated on a 5-point scale; the mean usefulness score was 4.5, while the mean ease of use score was 4.7. CONCLUSION: Different users at four different centers found the laser guidance system useful and easy to use. A high level of accuracy of the puncture angle was obtained in most cases.

Adult↗

Posterior semicircular canal dehiscence: a morphologic cause of vertigo similar to superior semicircular canal dehiscence.

The aim of this study was to assess imaging findings of posterior semicircular dehiscence on computed tomography and to evaluate incidence of posterior and superior semicircular canal dehiscence in patients presenting with vertigo, sensorineuronal hearing loss or in a control group without symptoms related to the inner ear. Computed tomography was performed in 507 patients presenting either with vertigo ( n=128; 23 of these patients suffered also from sensorineuronal hearing loss), other symptoms related to the inner ear, such as hearing loss or tinnitus ( n=183) or symptoms unrelated to the labyrinth ( n=196). All images were reviewed for presence of dehiscence of the bone, overlying the semicircular canals. Twenty-nine patients had superior semicircular canal dehiscence. Of these patients, 83% presented with vertigo, 10% with hearing loss or tinnitus and the remaining 7% with symptoms unrelated to the inner ear. In 23 patients dehiscence of the posterior semicircular canal was encountered. Of these patients, 86% presented with vertigo, 9% with hearing loss or tinnitus and 5% with symptoms unrelated to the inner ear. Defects of the bony overly are found at the posterior semicircular canal, in addition to the recently introduced superior canal dehiscence syndrome. Significant prevalence of vertigo in these patients suggests that posterior semicircular canal dehiscence can cause vertigo, similar to superior semicircular canal dehiscence.

Case-Control Studies↗

[Sonografic evaluation of oxygenation in head and neck cancer].

BACKGROUND: Tumor oxygenation is an important aspect of radiosensitivity. The authors describe a new method for a non-invasive assessment of tumor oxygenation in head and neck cancer. PATIENTS AND METHODS: A group of 20 patients with neck metastases of squamous cell cancer of the head and neck region was surveyed. At first a pO (2)-polarography was performed in the metastatic cervical nodes to investigate the tissue oxygenation. In a second step, the vascularisation of these nodes was visualised by color duplex sonography. In order to evaluate the extent of vascularisation in these nodes, the density of color pixels was quantified by a custom-made software program. The color pixel density and the pO (2) values were correlated and the statistic significance was calculated by Pearson's test. RESULTS: The mean vascularisation as evaluated by the means of color duplex sonography was 7.78 % [95 % CI 6.04 - 9.51]. The interindividual pO (2) values in the stroma of metastatic lymph nodes ranged between 9.0 and 27.4 mmHg (16.6 [95 % CI 14.06 - 19.13]). The mean values of pO (2)-fractions < 2.5/< 5.0/10 mm Hg were 32.25 %, 44.25 % and 53.29 % respectively. The median value of the pO (2)-fraction was 10.49 % [95 % CI 7.13 - 13.85]. The vascularisation as evaluated by color pixel density showed a statistically significant correlation with the pO (2)-fractions < 5.0 and < 10 mmHg (p < 0.045 and < 0.0001) and with the mean (p < 0.002) and median values of tissue pO (2) values (p < 0.0001) in polarography. CONCLUSION: The results in a limited number of patients suggest, that the proposed sonographic method allows a reliable non-invasive evaluation of tissue oxygenation in cervical metastases of squamous cell head and neck cancers.

Adult↗

Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI.

PURPOSE: To assess the value of different image reconstruction algorithms for assessment of the left ventricular function using retrospectively ECG-gated multislice spiral computed tomography (MSCT) of the heart. MATERIAL AND METHODS: MSCT and cine magnetic resonance (MR) imaging of the heart were performed in 15 patients. For MSCT, standard and multisegmental image reconstruction with improved temporal resolution were used. Standardized multiplanar reformats in the short axis and long axis views were reconstructed from MSCT data. End-systolic (ESV) and end-diastolic volume (EDV), stroke volume (SV), ejection fraction (EF) and myocardial mass (MM) were calculated. Left ventricular wall motion was assessed qualitatively. RESULTS: MSCT was in acceptable agreement with MR imaging for quantification of the ventricular function. According to the Bland-Altman approach the mean differences for the left ventricular volumes (ESV, EDV, SV) ranged from -9.6 ml to 3.1 ml with standard image reconstruction and from -0.6 ml to 1.9 ml utilizing multisegmental image reconstruction with limits of agreement ranging from -26.6 ml to 12.5 ml and -15.6 ml to 15.0 ml, respectively. Applying the multisegmental image reconstruction algorithm, a significantly improved agreement with the MR data was found for EDV, SV and EF. For wall motion analysis, standard image reconstruction showed a significant difference to MR imaging with a correspondence in 83.75% of the 240 assessed segments, while multisegmental image reconstruction agreed with MR imaging in 92.5% of the segments. CONCLUSION: Multisegmental image reconstruction improves the quantitative assessment of left ventricular function when compared to standard image reconstruction. Multisegmental image reconstruction allows qualitative wall motion analysis.

Adult↗

Measurement of motor evoked potentials following repetitive magnetic motor cortex stimulation during isoflurane or propofol anaesthesia.

BACKGROUND: Isoflurane and propofol reduce the recordability of compound muscle action potentials (CMAP) following single transcranial magnetic stimulation of the motor cortex (sTCMS). Repetition of the magnetic stimulus (repetitive transcranial magnetic stimulation, rTCMS) might allow the inhibition caused by anaesthesia with isoflurane or propofol to be overcome. METHODS: We applied rTCMS (four stimuli; inter-stimulus intervals of 3, 4, 5 ms (333, 250, 200 Hz), output 2.5 Tesla) in 27 patients and recorded CMAP from the hypothenar and anterior tibial muscle. Anaesthesia was maintained with fentanyl 0.5-1 microg kg(-1) x h(-1) and either isoflurane 1.2% (10 patients) or propofol 5 mg kg(-1) x h(-1) with nitrous oxide 60% in oxygen (17 patients). RESULTS: No CMAP were detected during isoflurane anaesthesia. During propofol anaesthesia 333 Hz, four-pulse magnetic stimulation evoked CMAP in the hypothenar muscle in 75%, and in the anterior tibial muscle in 65% of the patients. Less response was obtained with 250 and 200 Hz stimulation. CONCLUSIONS: In most patients, rTCMS can overcome suppression of CMAP during propofol/nitrous oxide anaesthesia, but not during isoflurane anaesthesia. A train of four magnetic stimuli at a frequency of 333 Hz is most effective in evoking potentials from the upper and lower limb muscles. The authors conclude that rTCMS can be used for evaluation of the descending motor pathways during anaesthesia.

Adult↗

The petromastoid canal on computed tomography.

The objective was to assess visibility and anatomy of the petromastoid canal in high-resolution CT. Computed tomography images of 188 patients were reviewed for delineation of the petromastoid canal. This bony canal connects the mastoid antrum with the cranial cavity and houses the subarcuate artery and vein. The diameter, obtained in the middle portion of the canal, was compared with the diameter of the vestibular and cochlear aqueduct in all patients, and absolute values measured in 20 cases. Collimation was 1 mm in 164 and 2 mm in 24 examinations. Additionally, temporal bone of a cadaver was imaged and microdissected. The petromastoid canal was identified bilaterally in all 164 scans that were obtained with a slice thickness of 1 mm. In 5 of the 24 patients imaged with a collimation of 2 mm, the canal was not visible, most probably due to partial-volume effects. The petromastoid canal had the same diameter as the cochlear aqueduct in 42/44 (right/left), exceeded it in 66/61 and was smaller in 75/78 cases. In comparison to the vestibular aqueduct it had an equal diameter in 38/41 (right/left), exceeded it in 63/61, and was rated as smaller in 82/81 temporal bones. Diameters for the canals were: petromastoid canal 0.51+/-0.04 mm; cochlear aqueduct 0.57+/-0.03; and vestibular aqueduct 0.63+/-0.06 mm. Microdissection of the specimen revealed the entire course of the canal and demonstrated a similar appearance of the structure as in the images. The petromastoid canal can easily be identified on high-resolution, thin-slice CT images. Knowledge of the anatomy of this bony canal prevents misinterpretation as pathological structure, such as fracture line, which might occur if this structure is not known.

Adult↗

Virtual endoscopy combined with intraoperative neuronavigation for planning of endoscopic surgery in patients with occlusive hydrocephalus and intracranial cysts.

We assessed the clinical value of MR ventriculoscopy (virtual endoscopy, VE) combined with image-guided frameless stereotaxy for endoscopic surgery of occlusive hydrocephalus and intracranial cysts. VE was obtained in 20 patients with hydrocephalus and three with intracranial cysts. All surgical operations were endoscopic. The path of the rigid endoscope to the target point was planned using neuronavigation. VE was carried out along the same trajectory retrospectively in 20 cases and prospectively in three. The results were analysed for demonstration of anatomical landmarks and structures at risk. VE was successful in all patients. Possible obstacles to endoscopic access to the lamina terminalis and the basal cisterns and structures at risk, such as the basilar artery, were clearly shown in relation to the direction of the endoscope. However, the floor of the third ventricle and septum pellucidum were not clearly seen and possible abnormalities could therefore not be appreciated. VE can provide realistic simulation of endoscopic third ventriculostomy and cystostomy. The appropriate trepanation point and trajectory of the endoscope can be assessed with regard to the size of the foramen of Monro and the position of vulnerable structures. This simulated trajectory can be adapted to the field of operation by image-guided neuronavigation. This regime may potentially reduce the risk of damage to intracranial structures.

Adolescent↗

Error analysis in cranial neuronavigation.

Neuronavigation systems are now an important component of many modern neurosurgical treatment strategies. Their support facilities intraoperative orientation and makes neurosurgical operations more precise and less traumatic. Computer-aided neurosurgery is definitively not a temporary fashionable phenomenon, the concept of neuronavigation is here to stay. This report summarizes a ten-years-long experience and presents an error analysis of 108 failures (12.4 %) in a total of 874 image-guided cranial neurosurgical procedures with an arm-linked (mechanical) system and two different infrared-light emitting (optical) systems. The application of neuronavigation incurs multiple reasons for pitfalls because of the complex man-machine interface. Principally, we have to differentiate two types of errors: "machine made errors" due to soft- or hardware failure and "man made errors" generally, due to inadequate handling of the navigation system. The error analysis demonstrated that the so-called human interface plays the main role causing a high error rate.

Bias↗

[MR contrast media for cardiovascular imaging].

MR contrast media improve the diagnostic capability of MRI and MRA. They are used in the discrimination of viable and non-viable myocardium, transmural and non-transmural infarction, occlusive and reperfused infarction and for measurement of myocardial perfusion. Currently, clinical studies are almost completely restricted to the use of extracellular non-specific MR contrast media (i. e., Gd-DTPA, Gd-DTPA,-BMA, Gd-BOPTA, Gd-D03A). However, the feasibility of using intravascular, necrosis specific or intracellular MR contrast media or endogeneous substrates as specific MR contrast media in cardiovascular imaging has been demonstrated in experimental and a few clinical studies. Intravascular contrast media (i. e., MS-325 or NC100150 Injection) allow assessment of microvascular integrity and performance of MR angiography. Necrosis specific contrast media (i. e., Gadophrin-2) have been used for sizing the extent of infarcted myocardium while intracellular contrast media (i. e., Mn-DPDP) delineate viable myocardium. Endogenous contrast media (i. e., Deoxyhemoglobin, Na (+) or K (+)) have been tested for detecting the alterations in concentrations of these ions in infarcted myocardium and for perfusion measurements. Furthermore, intravascular MR contrast media may be useful for MRA and MRI guided cardiovascular interventions.

Contrast Media↗

[Relevance of colour-duplex echography for detection and therapy of recurrences in the follow-up of head and neck cancer].

BACKGROUND: Head and neck malignancies have a high rate of recurrences. Since the prognosis is often limited an early detection and therapy onset is essential for survival. This study surveys the relevance of regular colour-duplex echography examinations in the follow-up for detection and therapy of recurrent head and neck carcinomas. PATIENTS AND METHODS: In a prospective non-randomized study 43 patients were surveyed over a mean observation period of 28 (8-44) months. In addition to clinical and colour-duplex echography (CDS) examinations, computed tomography (CT) and positron-emission-tomography using 18fluorodeoxyglucose (PET) were performed. RESULTS: A recurrence was detected in 17/43 (39.5 %) patients. The median survival was 42 months. CDS was the most reliable procedure for the diagnosis of regional recurrences with an accuracy of 94.2 %. Sensitivity and specificity of CDS for the diagnosis of all recurrences was found to be 80 % and 78,6 % respectively. CT yielded identical results. In PET sensitivity was 82.4 % and specificity was found to be 88.4 %. In clinical examinations including panendoscopy sensitivity was 64.7 % only. In 7/17 recurrences a therapy was performed with curative intention. In 4 cases an early diagnosis by CDS contributed to a successful therapy. CONCLUSION: CDS is the imaging procedure of choice for the routine follow-up of head and neck cancer patients. In order to perform a comprehensive assessment of the head and neck region, for re-staging and to exclude second primary tumours additional (pan)endoscopy is necessary. CDS supports due to a high resolution and reliability an early therapy onset and a minimal invasive therapy. Thus, this procedure can significantly contribute to the successful treatment of recurrences in head and neck cancer.

Adenocarcinoma↗