Search PubMed⌕ Search

Biomedical subjects

Fred Morady

Publications and source records attributed to Fred Morady.

At least 91 records · Page 5Linked to original sources

Anatomy of the pulmonary veins in patients with atrial fibrillation and effects of segmental ostial ablation analyzed by computed tomography.

INTRODUCTION: The anatomic arrangement of pulmonary veins (PVs) is variable. No prior studies have quantitatively analyzed the effects of segmental ostial ablation on the PVs. The aim of this study was to determine the effect of segmental ostial radiofrequency ablation on PV anatomy in patients with atrial fibrillation (AF). METHODS AND RESULTS: Three-dimensional models of the PVs were constructed from computed tomographic (CT) scans in 58 patients with AF undergoing segmental ostial ablation to isolate the PVs and in 10 control subjects without a history of AF. CT scans were repeated approximately 4 months later. PV and left atrial dimensions were measured with digital calipers. Four separate PV ostia were present in 47 subjects; 3 ostia were present in 2 subjects; and 5 ostia were present in 9 subjects. The superior PVs had a larger ostium than the inferior PVs. Patients with AF had a larger left atrial area between the PV ostia and larger ostial diameters than the controls. Segmental ostial ablation resulted in a 1.5 +/- 3.2 mm narrowing of the ostial diameter. A 28% to 61% focal stenosis was present 7.6 +/- 2.2 mm from the ostium in 3% of 128 isolated PVs. There were no instances of symptomatic PV stenosis during a mean follow-up of 245 +/- 105 days. CONCLUSION: CT of the PVs allows identification of anatomic variants prior to catheter ablation procedures. Segmental ostial ablation results in a significant but small reduction in ostial diameter. Focal stenosis occurs infrequently and is attributable to delivery of radiofrequency energy within the PV.

Atrial Fibrillation↗

Role of the coronary sinus in maintenance of atrial fibrillation.

INTRODUCTION: Bursts of tachycardia arising in the pulmonary veins may play an important role in perpetuating atrial fibrillation (AF). However, the role of the coronary sinus (CS) in the perpetuation of AF has been unclear. The aim of this study was to determine whether the CS plays a role in perpetuation of AF. METHODS AND RESULTS: Pulmonary vein isolation was performed by segmental ostial ablation with radiofrequency energy in 22 consecutive patients with paroxysmal AF. Bipolar and unipolar electrograms recorded in the left atrium and CS were analyzed during atrial pacing from the mitral annulus and during AF. There was a mean of 2.5 +/- 0.5 electrical connections between the CS and the left atrium. The electrical connections between the left atrium and CS were ablated with a mean of 6.2 +/- 2.7 minutes of radiofrequency energy applied along the atrial side of the inferior mitral annulus. During AF, episodes of intermittent tachycardia alternated between the left atrium and the CS. Among the 22 patients, sustained AF was still inducible in 9 after pulmonary vein isolation. After electrical disconnection of the CS from the left atrium, sustained AF was inducible in only 3 of these 9 patients. CONCLUSION: The CS may be a source of rapid repetitive electrical activity during AF. The lower probability of inducible sustained AF after electrical disconnection of the CS from the left atrium suggests that the CS may play a role in perpetuating AF.

Atrial Fibrillation↗

Effect of atrial fibrillation duration on probability of immediate recurrence after transthoracic cardioversion.

INTRODUCTION: An immediate recurrence of atrial fibrillation (IRAF) appears to be more common after early restoration of sinus rhythm with an implantable atrial defibrillator than after elective transthoracic cardioversion, which suggests that the probability of IRAF may be related to the duration of AF. METHODS AND RESULTS: Transthoracic cardioversion was performed 85 +/- 187 days (range 7 minutes to 8 years) after the onset of atrial fibrillation in 315 patients (mean age 61 +/- 13 years). IRAF was defined as a recurrence of AF within 60 seconds after restoration of sinus rhythm. IRAF occurred in 56% of patients when cardioversion was performed within 1 hour of the onset of AF compared with 12% of patients when cardioversion was performed after 24 hours of AF (P < 0.001). The duration of AF was the only independent predictor of IRAF among the clinical variables of age, gender, structural heart disease, antiarrhythmic drug therapy, and cardioversion energy (P < 0.01). CONCLUSION: IRAF is more likely to occur when the duration of AF is <1 hour than when the duration is >24 hours. This observation has clinical implications for the most appropriate timing of cardioversion, particularly in patients who receive device therapy for AF.

Atrial Fibrillation↗

Segmental ostial ablation to isolate the pulmonary veins during atrial fibrillation: feasibility and mechanistic insights.

BACKGROUND: The purpose of this study was to determine the feasibility and mechanistic implications of segmental pulmonary vein (PV) ostial ablation during atrial fibrillation (AF). METHODS AND RESULTS: Forty consecutive patients underwent PV isolation for AF. Among 125 PVs targeted for isolation, ablation was performed during AF in 70 veins and during sinus rhythm in 55 veins. A decapolar Lasso catheter was positioned near the ostium. During AF, ostial ablation was performed near the Lasso catheter electrodes that recorded a tachycardia with a cycle length shorter than in the adjacent left atrium. During sinus rhythm, ostial ablation was guided by PV potentials. Complete PV isolation was achieved in 70 PVs (100%) ablated during AF and in 53 PVs (96%) ablated during sinus rhythm (P=0.4). The mean durations of radiofrequency energy needed for isolation were 7.4+/-4.4 and 5.2+/-3.9 minutes during AF and sinus rhythm, respectively (P<0.01). Before ablation, an immediate recurrence of AF (IRAF), occurred after cardioversion in 18 of 40 patients, and IRAF was consistently abolished by PV isolation. The probability of AF termination during isolation of a PV was directly related to the extent of tachycardia in that vein. As more PVs were isolated, induction of persistent AF by rapid pacing became less likely. CONCLUSIONS: Segmental ostial ablation guided by PV tachycardia during AF is feasible and as efficacious as during sinus rhythm. The responses to cardioversion, ablation, and rapid pacing observed in this study imply that IRAF is triggered by the PVs and that PV tachycardias may play an important role in the perpetuation of AF.

Atrial Fibrillation↗

Comparison of amiodarone versus ibutilide for the prevention of immediate recurrences of atrial fibrillation during pulmonary vein isolation.

During segmental ostial ablation for pulmonary vein isolation, pulmonary vein potentials are easily identified during sinus rhythm or left atrial pacing. Therefore, maintenance of atrial fibrillation (AF) during the procedure is desirable. However, cardioversion is occasionally followed by an immediate recurrence of AF. This study compared the efficacy of ibutilide and amiodarone in preventing immediate recurrences of AF in patients who underwent pulmonary vein isolation. The subjects of this study were 25 patients (mean age 56 +/- 10 years) who underwent pulmonary vein isolation for AF who had an immediate recurrence of AF within 60 seconds after 2 transthoracic cardioversions. The patients were randomized to receive an infusion of either 300 mg of amiodarone over 10 minutes or 1 mg of ibutilide over 5 minutes. Cardioversion was repeated 15 minutes after the drug infusion. If immediate recurrences of AF occurred 2 more times, the alternative study drug was administered, and cardioversion was repeated. Immediate recurrences of AF were suppressed by amiodarone in 8 of 10 patients (80%), and by ibutilide in 9 of 15 patients (60%, p = 0.4). After crossover, immediate recurrence of AF was suppressed in 2 of 6 patients (33%) by amiodarone, and in 1 of 2 patients (50%) by ibutilide (p = 0.6). Ibutilide and amiodarone, when used alone or in combination, prevented immediate recurrences of AF in 20 of 25 patients (80%). There were no adverse drug effects. Ibutilide and amiodarone were equally effective in suppressing immediate recurrences of AF. Overall, immediate recurrences of AF can be prevented by amiodarone and/or ibutilide in 80% of patients.

Aged↗

Clinical significance of early recurrences of atrial fibrillation after pulmonary vein isolation.

OBJECTIVES: The purposes of this study were to describe the prevalence of early recurrences of atrial fibrillation (ERAF) that occur within two weeks after pulmonary vein (PV) isolation, and to determine whether ERAF is predictive of long-term outcome after PV isolation. BACKGROUND: Atrial fibrillation (AF) sometimes recurs within days after PV isolation and may prompt an early repeat intervention. METHODS: Segmental PV isolation was performed using radiofrequency energy in 110 consecutive patients (mean age 53 +/- 11 years) with paroxysmal (93 patients) or persistent (17 patients) AF. Three to four PVs were targeted for isolation in all patients. Pulmonary vein isolation was complete in 338 of the 358 PVs that were targeted (94%). RESULTS: Early recurrences of AF occurred in 39 of 110 patients (35%) at a mean of 3.7 +/- 3.5 days after the procedure. The prevalence of ERAF was similar in patients with paroxysmal and persistent AF (33% and 47%, respectively, p = 0.4). Beyond the first two weeks, at 208 +/- 125 days of follow-up, 60 of the 71 patients without ERAF (85%) and 12 of the 39 patients with ERAF (31%) were free of recurrent AF in the absence of antiarrhythmic drug therapy (p < 0.001). CONCLUSIONS: Early recurrences of AF occur in approximately 35% of patients within two weeks after isolation of three to four PVs, and are associated with a lower long-term success rate than in patients without ERAF. However, approximately 30% of patients with ERAF have no further symptomatic AF during long-term follow-up. Therefore, temporary antiarrhythmic drug therapy may be more appropriate than early repeat ablation in patients with ERAF.

Anti-Arrhythmia Agents↗

Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation.

BACKGROUND: The pulmonary veins (PVs) have been demonstrated to often play an important role in generating atrial fibrillation (AF). The purpose of this study was to determine the safety and efficacy of segmental PV isolation in patients with paroxysmal or persistent AF. METHODS AND RESULTS: In 70 consecutive patients (mean age, 53 +/- 11 years) with paroxysmal (58) or persistent (12) AF, segmental PV isolation guided by ostial PV potentials was performed. The left superior, left inferior, and right superior PVs were targeted for isolation in all patients, and the right inferior PV was isolated in 20 patients. Among the 230 targeted PVs, 217 (94%) were completely isolated, with a mean of 6.5 +/- 4.2 minutes of radiofrequency energy applied at a maximum power setting of 35 W. A second PV isolation procedure was performed in 6 patients (9%). At 5 months of follow-up, 70% of patients with paroxysmal and 22% of patients with persistent AF were free from recurrent AF (P<0.001), and 83% of patients with paroxysmal AF were either free of symptomatic AF or had significant improvement. Among various clinical characteristics, only paroxysmal AF was an independent predictor of freedom from recurrence of AF (P<0.05). One patient developed unilateral quadrantopsia after the procedure. There were no other complications. CONCLUSIONS: With a segmental isolation approach that targets at least 3 PVs, a clinically satisfactory result can be achieved in >80% of patients with paroxysmal AF. The clinical efficacy of pulmonary vein isolation is much lower when AF is persistent than when it is paroxysmal.

Adult↗

Mechanism of ventricular tachycardia termination by pacing at left ventricular sites in patients with coronary artery disease.

OBJECTIVE: The mechanism by which pacing terminates ventricular tachycardia (VT) may depend on the location of the pacing site relative to the reentry circuit. The purpose of this study was to compare the mechanisms by which pacing terminates VT at left ventricular (LV) sites with and without concealed entrainment (CE) in patients with prior myocardial infarction. METHODS AND RESULTS: LV mapping was performed in 29 patients (26 men, 3 women, mean age 67 +/- 11 years, ejection fraction 0.28 +/- 0.11) with 55 hemodynamically-tolerated VTs (mean cycle length 478 +/- 92 msec). A total of 408 pacing trains were delivered at 102 sites with CE. Radiofrequency catheter ablation was successful in 41 of 55 VT's. At sites with concealed entrainment, VT was terminated by pacing at 17/41 (41%) successful and at 4/61 (7%) unsuccessful ablation sites (p<0.01). Termination without global ventricular capture was the most frequent termination mode (10/21), followed by termination with orthodromic (4/21) and non-orthodromic capture (7/21). CONCLUSION: In patients with prior myocardial infarction, pacing at sites of CE during VT usually terminates VT either without global capture or by orthodromic capture. Termination of VT by pacing without global capture or with orthodromic capture at sites of CE suggests that the site is within a critical area of the reentry circuit.

Aged↗

Analysis during sinus rhythm of critical sites in reentry circuits of postinfarction ventricular tachycardia.

BACKGROUND: Critical sites within reentry circuits of postinfarction ventricular tachycardia (VT) were identified during sinus rhythm (SR) and VT to determine whether electrogram characteristics during SR may be helpful in identifying successful ablation sites. METHODS: In 33 patients (mean age 67 +/- 11 yrs) with prior infarction, mapping and radiofrequency (RF) catheter ablation of 57 hemodynamically-tolerated VT's (cycle length 478 +/- 96) were performed. The morphologies of electrograms (EGM) at sites of concealed entrainment (CE) were compared during SR and VT. RF energy was delivered at 94 sites (51 successful and 43 unsuccessful ablation sites). RESULTS: During SR, isolated potentials (IP), but not late potentials (LP) recorded via the mapping catheter, were associated with successful ablation. At 29/39 sites with an IP during sinus rhythm, an isolated diastolic potential (IDP) also was present during VT, whereas at 4 sites IP's were present only during SR (p < 0.001). At 11/29 sites where isolated potentials were present during SR and VT, the morphology of the isolated potential during VT and SR was similar; and all but one of these sites were successful ablation sites (p = 0.01). The EGM amplitude during VT correlated with the amplitude during SR (R = 0.9, p < 0.001). An identical pacemap was present during SR at 33/94 sites; this was not associated with successful ablation. CONCLUSION: SR mapping may be helpful in identifying critical sites of reentry in postinfarction VT. At sites within the reentry circuit, characteristics of sinus rhythm EGM's that are associated with successful ablation include the presence of IP's, but not the presence of LP's.

Action Potentials↗

Clinical predictors of successful cephalic vein access for implantation of endocardial leads.

BACKGROUND: The purpose of this study was to determine whether there are any patient characteristics that predict successful use of the cephalic vein for endocardial lead implantation. METHODS: One-hundred fifty consecutive patients who underwent implantation of one or more endocardial pacemaker (N = 63) or defibrillator (N = 87) leads using a cephalic vein approach were included in this prospective study. The mean age of the patients was 63 +/- 14 years, and 115 (77%) were men. Ninety-one patients (61%) had coronary artery disease, 77 patients (51%) had hypertension, and 42 patients (28%) had diabetes. The mean ejection fraction was 0.34 +/- 0.17. RESULTS: At least one lead was successfully implanted using a cephalic vein approach in 96 patients (64%). The most common reason for failure of the cephalic vein approach was a small cephalic vein, found in 25 patients (17%). Independent predictors of successful cephalic vein use were diabetes (p < 0.001), ejection fraction < or = 0.40 (p < 0.05), and male gender (p < 0.05). At least one endocardial lead was implanted in 19 of the 24 (79%) men who had an ejection fraction < or = 0.40 and diabetes, compared to 4 of the 11 (36%) women who had an ejection fraction > 0.40 and did not have diabetes. The only independent predictor of successful cephalic vein implantation among nondiabetics was an ejection fraction < or = 0.40 (p < 0.01). Body size was not an independent predictor of successful cephalic vein use. CONCLUSION: Baseline patient characteristics influence the likelihood of successful endocardial lead implantation using a cephalic vein approach. Diabetes, ventricular dysfunction, male gender and are associated with an increased likelihood of a successful implant using the cephalic vein. Smaller leads and and better techniques are needed to improve the success rate of cephalic vein implantation in all patients.

Aged↗

Pulmonary vein isolation: comparison of bipolar and unipolar electrograms at successful and unsuccessful ostial ablation sites.

INTRODUCTION: No prior studies have quantitatively analyzed the characteristics of bipolar or unipolar electrograms that may be helpful in identifying successful ostial ablation sites in patients with atrial fibrillation undergoing segmental pulmonary vein isolation. METHODS AND RESULTS: The characteristics of bipolar and unipolar electrograms recorded at 185 successful and 120 unsuccessful ostial pulmonary venous ablation sites were analyzed in 21 patients with atrial fibrillation. A decapolar Lasso catheter was positioned near the ostia of the pulmonary veins, and a conventional ablation catheter was used to deliver radiofrequency energy at individual ostial sites where pulmonary vein potentials were recorded. With both bipolar and unipolar recordings, the only timing parameter that distinguished successful from unsuccessful ostial ablation sites was the timing of the electrogram recorded by the ablation catheter relative to the earliest pulmonary vein potential recorded by the Lasso catheter. With both bipolar and unipolar recordings, electrograms demonstrated a larger amplitude at successful than at unsuccessful ablation sites. Unipolar electrograms had a steeper intrinsic deflection at successful than at unsuccessful ostial ablation sites. The morphologies of the unipolar electrograms recorded by the ablation catheter and by the contiguous electrode of the Lasso catheter usually were identical. CONCLUSION: In patients undergoing segmental isolation of the pulmonary veins, unipolar recordings provide more information than bipolar recordings helpful in distinguishing successful from unsuccessful ostial ablation sites. Furthermore, unipolar recordings, but not bipolar recordings, allow accurate localization of the position of the ablation catheter relative to the electrodes of the Lasso catheter.

Adult↗

Response of pulmonary vein potentials to premature stimulation.

INTRODUCTION: Pulmonary vein potentials reflect depolarization of muscle fascicles within the myocardial sleeves that surround the pulmonary veins. The response of pulmonary vein potentials to premature stimulation has not been described. METHODS AND RESULTS: In 31 patients with paroxysmal atrial fibrillation referred for segmental isolation of the pulmonary veins, programmed stimulation with a single atrial extrastimulus was performed from the coronary sinus. Bipolar and unipolar electrograms were recorded with a decapolar Lasso catheter positioned sequentially within the left superior, left inferior, and right superior pulmonary veins, near the ostium. Premature stimulation often resulted in greater separation of the atrial and pulmonary vein potentials recorded within the pulmonary veins, fractionation of the pulmonary vein potentials, a change in the circumferential activation sequence of the pulmonary vein potentials, and dropout of pulmonary vein potentials. CONCLUSION: In response to premature stimulation, the muscle fascicles within the myocardial sleeves that surround the pulmonary veins display a greater degree of decremental conduction than do the myocardial fibers in the adjacent left atrium, and they display heterogeneity in conduction properties and refractoriness. Discrimination of pulmonary vein potentials from atrial electrograms is facilitated by premature stimulation.

Angiography↗