RF catheter ablation: Lessons on lesions.

The present treatment of atrial fibrillation by radiofrequency catheter ablation requires long continuous lesions in the thin walled left atrium where side effects may lead to serious complications. Better understanding of the physical processes that take place during ablation may help to improve the quality, safety, and outcome of these procedures. These processes include the distribution of power between blood, tissue, and patient; the mechanisms of tissue heating and coagulum formation; the relation between tissue and electrode temperatures; and the effects of increased electrode size and internal and external electrode cooling. With normal electrode-tissue contact, only a fraction of all power is effectively delivered to the tissue. Due to the variability of blood flow cooling, applied power and electrode temperature rise are poor indicators of lesion formation. With a longer electrode, the efficiency of tissue heating is decreased and the greater variation in tissue contact caused by electrode orientation makes lesion formation even more unpredictable. The absence of impedance rise during ablation does not guarantee the absence of blood clot formation on the tissue contact site. Blood clots may unnoticeably be created on the lesion surface and are caused by thermal denaturization of blood proteins, independent of heparinization. Irrigated ablation with external flush may prevent blood clot formation. Irrigation minimally affects lesion size by cooling the tissue surface. Larger lesions may only be created by the application of higher power levels. Electrode cooling, however, impedes electrode temperature feed back and blinds the operator for excessive tissue heating. External cooling alone with preservation of temperature feed back is a promising concept that may lead to improved procedural safety and success.

Animals↗

Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop.

BACKGROUND: Electrode cooling by circulating fluid within the electrode (closed loop) or open irrigation facilitates radiofrequency (RF) ablation. This study compared lesion parameters between closed loop and open irrigation with the use of a canine model. METHODS AND RESULTS: In 8 anesthetized dogs, the skin over the thigh muscle was incised and raised, forming a cradle superfused with heparinized blood (activated clotting time >350 seconds) at 37 degrees C. A 7F 4-mm closed loop electrode (irrigation 36 mL/min) and 7.5F 3.5-mm open irrigation electrode (irrigation 17 mL/min) were positioned perpendicular to the thigh muscle at 10 g contact weight. RF was applied (n=121) at 20 or 30 W for 60 seconds in low (0.1 m/s) or high (0.5 m/s) pulsatile blood flow. Temperatures were measured in the electrode, electrode-tissue interface, and within the tissue at 3- and 7-mm depths. After each RF, the cradle was emptied to examine the electrode and interface for thrombus. There was no difference between closed loop and open irrigation in impedance, lesion depth, or tissue temperature at 20 or 30 W. Interface temperature and electrode temperature were greater in the closed loop application. Thrombus occurred in 32 of 63 closed loop versus 0 of 58 open irrigation RF applications (P<0.05) with interface temperature > or =80 degrees C in all 32 (electrode temperature <40 degrees C in 1, 40 degrees C to 50 degrees C in 26, and >50 degrees C in 5). With closed loop, interface temperature and thrombus incidence were greater at 30 W and low blood flow. With open irrigation, interface temperature remained low (< or =71 degrees C) with no difference between 20 and 30 W or between low and high blood flow. Steam pop occurred at 20 W in 4 of 35 closed loop and 0 of 30 open irrigation and at 30 W in 15 of 28 closed loop and 4 of 28 open irrigation applications (P<0.05). CONCLUSIONS: Lower interface temperature, thrombus, and steam pop, especially in low blood flow, indicate greater interface cooling with open irrigation.

Animals↗

Where to draw the mitral isthmus line in catheter ablation of atrial fibrillation: histological analysis.

AIMS: A linear lesion between the left inferior pulmonary vein orifice and mitral annulus, the so-called mitral isthmus, may improve the success of catheter ablation for atrial fibrillation. Gaps in the lesion line, however, may facilitate left atrial flutter. The aim of the study was to determine the optimal location of the lesion line by serial sectioning of the isthmus area. METHODS AND RESULTS: In a post-mortem study of 16 patients with normal left atria, serial sections of the isthmus area from 10 mm superior to and 30 mm inferior to the isthmus were studied by light microscopy. The length of the isthmus was 35+/-7 mm. On average, the muscle sleeve around the coronary sinus ended 10 mm inferior to the isthmus. The prevalence of a ramus circumflexus <5 mm from the endocardial surface, decreased from 60% in the most superior section to 0% in the most inferior section. Atrial arteries were frequently present in all sections. CONCLUSIONS: The thickness of atrial myocardium, the ramus circumflexus sometimes very close to the endocardium, a myocardial sleeve around the coronary sinus, and local cooling by atrial arteries and veins may complicate the creation of conduction block in the mitral isthmus.

Atrial Fibrillation↗

Saline-irrigated radiofrequency ablation electrode with external cooling.

INTRODUCTION: Open flush, irrigated ablation electrodes may improve the safety of radiofrequency catheter ablation by preventing protein aggregation and coagulum formation. This is particularly important in left-sided procedures like catheter ablation of atrial fibrillation. Electrode cooling and the inherent loss of temperature feedback, however, grossly reduce the ability to monitor tissue heating. Intimate contact may not be recognized and the delivery of nominal RF power levels may then lead to excessive tissue heating, steam explosions, and even tamponade. METHODS AND RESULTS: Standard, open flush, irrigated catheters (Sprinklr, Medtronic Inc, Minneapolis, MN) were modified by thermally insulating the irrigation channels inside the ablation electrode. Using the thigh muscle preparation, multiple lesions were created with standard and modified catheters using 60 s, 20-50 Watt applications and a constant saline flush rate of 20 cc/min. A total of 57 lesions were created on five thigh muscles of three dogs. Lesion dimensions were not significantly different between both types of catheter, but the maximum electrode temperature rise during ablation was significantly higher with the modified catheter. Insulation of the irrigation channels improved the correlation coefficient between maximum electrode temperature rise and lesion volume from 0.38 (ns) to 0.62 (P < 0.001). CONCLUSION: Thermal insulation of the irrigation channels facilitates temperature feedback during radiofrequency ablation and controllability of lesion formation.

Animals↗

Radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia in children aided by the LocaLisa mapping system.

AIMS: In young patients, slow pathway ablation for treatment of atrioventricular nodal reentrant tachycardia (AVNRT) carries a small but definite risk of permanent AV block. The aim was to assess the efficacy of slow pathway ablation aided by the LocaLisa mapping system. PATIENTS AND METHODS: Radiofrequency (RF) modification of the slow AV nodal pathway was performed in 26 children < 19 years of age (median age 9.8 years, range 3-18.9). Three measures to limit the risk of AV block were applied: (1) use of LocaLisa, a non-fluoroscopic mapping system, to determine and mark the location of the AV node/His bundle axis, and monitor ablation catheter position, (2) continuous atrial stimulation during RF delivery to monitor AV conduction, and (3) gradual increase of RF power during RF ablation. RESULTS: AVNRT was rendered non-inducible in all patients. Dual AV physiology was abolished in 24/26 patients; 2 patients had single atrial echoes at the end of the procedure. At follow-up, AVNRT recurred in 3 patients (including the above 2), necessitating a second procedure. The median number of RF applications was 4 (3-8); median fluoroscopy time was 16 (7-33)min. One patient developed transient second-degree AV block, with full recovery within 6 weeks of the procedure. CONCLUSIONS: RF modification of the slow AV nodal pathway in children can be safely accomplished, achieving the ideal end-point of abolishing dual AV physiology, aided by use of the LocaLisa mapping system.

Adolescent↗

Pulmonary vein ostium geometry: analysis by magnetic resonance angiography.

BACKGROUND: During a catheter ablation procedure for selective electrical isolation of pulmonary vein (PV) ostia, the size of these ostia is usually estimated using fluoroscopic angiography. This measurement may be misleading, however, because only the projected supero/inferior ostium diameters can be measured. In this study, we analyzed 3-dimensional magnetic resonance angiographic (MRA) images to measure the minimal and maximal cross-sectional diameter of PV ostia in relation to the diameter that would have been projected on fluoroscopic angiograms during a catheter ablation procedure. METHODS AND RESULTS: In 42 patients with idiopathic atrial fibrillation who were scheduled for selective electrical isolation of PV ostia, the minimal and maximal diameters of these ostia were measured from 3-dimensional MRA images. Thereafter, these images were oriented in a 45 degrees right or left anterior oblique direction and the projected diameter of the PV ostia were measured again. The average ratio between maximal and minimal diameter was 1.5+/-0.4 for the left and 1.2+/-0.1 for the right pulmonary vein ostia. Because of the orientation and oval shape of especially the left pulmonary vein ostia, their minimal diameters were significantly smaller than the projected diameters. CONCLUSION: Pulmonary vein ostia, especially those at the left, are oval with the short axis oriented approximately in the antero/posterior direction. Consequently, PV ostia may sometimes be very narrow despite a rather normal appearance on angiographic images obtained during a catheter ablation procedure.

Atrial Fibrillation↗

High incidence of thrombus formation without impedance rise during radiofrequency ablation using electrode temperature control.

The authors hypothesized that during RF ablation, the electrode to tissue interface temperature may significantly exceed electrode temperature in the presence of cooling blood flow and produce thrombus. In 12 anesthetized dogs, the skin over the thigh muscle was incised and raised to form a cradle that was superfused with heparinized canine blood (ACT > 350 s) at 37 degrees C. A 7 Fr, 4-mm or 8-mm ablation electrode containing a thermocouple was held perpendicular to the thigh muscle at 10-g contact weight. Interface temperature was measured at opposite sides of the electrode using tiny optical probes. RF applications (n = 157) were delivered at an electrode temperature of 45 degrees C, 55 degrees C, 65 degrees C, and 75 degrees C for 60 seconds, with or without pulsatile blood flow (150 mL/min). Without blood flow, the interface temperature was similar to the electrode temperature. With blood flow, the interface temperature (side opposite blood flow) was up to 36 degrees C and 57 degrees C higher than the electrode temperature using the 4- and 8-mm electrodes, respectively. After each RF, the cradle was emptied and the electrode and interface were examined. Thrombus developed without impedance rise at an interface temperature as low as 73 degrees C without blood flow and 80 degrees C with blood flow (11/16 RFs at 65 degrees C electrode temperature using 4 mm and 13/13 RFs at an electrode temperature of 55 degrees C using an 8-mm electrode with blood flow). With blood flow, interface temperature markedly exceeded the electrode temperature and the difference was greater with an 8-mm electrode (due to greater electrode cooling). In the presence of blood flow, thrombus occurred without an impedance rise at an electrode temperature as low as 65 degrees C with a 4-mm electrode and 55 degrees C with an 8-mm electrode.

Analysis of Variance↗

Radiofrequency catheter ablation of junctional ectopic tachycardia with preservation of atrioventricular conduction.

Junctional ectopic tachycardia is a relatively rare disorder, frequently refractory to drug therapy, and with a poor prognosis in childhood. This report describes a successful radiofrequency catheter ablation of the focus of this arrhythmia in a 9-year-old girl with preservation of normal atrioventricular conduction, using precise catheter navigation with the LocaLisa system and carefully titrated RF delivery.

Atrioventricular Node↗

Soft thrombus formation in radiofrequency catheter ablation.

During RF catheter ablation, local temperature elevation can result in coagulum formation on the ablation electrode, resulting in impedance rise. A recent study has also demonstrated the formation of a so-called soft thrombus during experimental ablations. This deposit poorly adhered to the catheter tip and did not cause an impedance rise. The mechanism of soft thrombus formation and the role of the natural coagulation system are unknown. The formation of a soft thrombus was investigated experimentally by temperature-controlled RF delivery in heparinized blood at different heparin concentrations and in serum. After 60 seconds of RF delivery in blood with an electrode target temperature of 80 degrees C, a semisolidified mass had formed around the ablation electrode at all heparin concentrations. A smaller but structurally similar deposit had formed after RF delivery in serum. Scanning electron microscopy analysis revealed that these deposits consist of denaturized and aggregated proteins, and not of a classical thrombus. The formation of the so-called soft thrombus resultsfrom heat induced protein denaturation and aggregation and occurs independent of heparin concentration and also in serum. The formation of such deposits may occur at temperatures well below 100 degrees C, which may have important consequences for further development of ablation technologies.

Catheter Ablation↗