Search PubMed⌕ Search

Biomedical subjects

Franz Kainberger

Publications and source records attributed to Franz Kainberger.

26 records · Page 2Linked to original sources

Hypertrophic osteoarthropathy caused by PGE1 in a patient with congestive heart failure during cardiac rehabilitation.

Continuous chronic drug infusion with PGE1 via a portable pump and neuromuscular electrical stimulation (NMES) help to improve the quality of life in patients with severe chronic heart failure waiting for a donor heart, as both treatments can be performed at home. We report a 56-year-old woman suffering from severe chronic heart failure, who was referred for a cardiac rehabilitation program because of progressive muscle weakness and weight loss. Due to her underlying heart disease she was unable to perform voluntary exercise. NMES of both knee extensor muscles was started. Under simultaneous chronic drug infusion with PGE1 via a portable pump the patient developed clinical signs of hypertrophic osteoarthropathy, which prevented her from continuing the rehabilitation program. X-ray examinations and bone scans concurred with the diagnosis of secondary hypertrophic osteoarthropathy. After the PGE1 dose had been reduced, the clinical signs of the osteoarthropathy resolved and the patient was able to continue the rehabilitation program with no difficulty. This case report underlines the importance of being aware of the potential side effects of modern cardiac drugs in the complex treatment of patients waiting for a donor heart.

Alprostadil↗

Benign fibrous histiocytoma of bone: a report of ten cases and review of literature.

The benign fibrous histiocytoma is a rare tumor with only a few descriptions. In order to better define the optimal therapeutic procedure and the necessity of surgery we retrospectively analyzed the patients of the orthopedic department. Benign fibrous histiocytoma occurred in the femur (n = 3), pelvis (n = 2), humerus, tibia, fibula, rib and spine. Pain as the cardinal symptom and a median age of 28 years are factors that differentiate benign fibrous histiocytoma from other metaphyseal fibrous lesions such as the nonossifying fibroma. Radiographic investigation of this entity showed osteolytic lesions with eccentric thinning of the cortex and small fissures. To a variable extent, sclerosis was found in the margin of the lesions. Computer tomography revealed dense soft tissue in the lesions, but one lesion was filled with fluid. The tumor was restricted to bone, with no periosteal or soft tissue reaction. Magnetic resonance imaging showed enhancement of the tumor after administration of contrast medium. All lesions had uniform histological findings. Although no pathologic fracture occurred in any case, local expansion of the tumor was indicated by cortical thinning, small fissures and pain. This implied that the patients needed prophylactic curettage and bone grafting. Surgery restricted to the osteolytic area was sufficient to prevent recurrence.

Adult↗

Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible.

The overall accuracy of a novel surgical computer-aided navigation system for placement of endosseous implants was evaluated. Five dry cadaver mandibles were scanned using high resolution computed tomography (HRCT). The position of four interforaminal dental implants was planned on the computer screen and transferred to the cadaver mandibles using VISIT, a surgical navigation software developed at the Vienna General Hospital. The specimens were HRCT-scanned again to compare the position of the implants with the preoperative plan on reformatted slices after matching of the pre- and postoperative data sets using the mutual information technique. The overall accuracy was 0.96 +/- 0.72 mm (range 0.0-3.5 mm). No perforation of the mandibular cortex or damage to the mandibular canal occurred. We conclude that computer-aided implant surgery can reach a level of accuracy where further clinical developments are feasible.

Cadaver↗

Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery.

We developed a head-mounted display (HMD) with integrated computer-generated stereoscopic projection of target structures and integrated it into visit, a specific oral implant planning and navigation software. The HMD is equipped with two miniature computer monitors that project computer-generated graphics stereoscopically into the optical path. Its position is tracked by the navigation system's optical tracker and target structures are displayed in their true position over the operation site. In order to test this system's accuracy and spatial perception of the viewer, five interforaminal implants in three dry human mandibles were planned with visit and executed using the stereoscopic projection through the HMD. The deviation between planned and achieved position of the implants was measured on corresponding computed tomography (CT) scan images recorded post-operatively. The deviation between planned and achieved implant position at the jaw crest was 0.57 +/- 0.49 mm measured from the lingual, and 0.58 +/- 0.4 mm measured from the buccal cortex. At the tip of the implants the deviation was 0.77 +/- 0.63 mm at the lingual and 0.79 +/- 0.71 mm at the buccal cortex. The mean angular deviation between planned and executed implant position was 3.55 +/- 2.07 degrees. The present in vitro experiment indicates that the concept of preoperative planning and transfer to the operative field by an HMD allows us to achieve an average precision within 1 mm (range up to 3 mm) of the implant position and within 3 degrees deviation for the implant inclination (range up to 10 degrees ). Control during the drilling procedure is significantly improved by stereoscopic vision through the HMD resulting in a more accurate inclination of the implants.

Computer Graphics↗

Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems.

This study aims to provide a quantitative analysis of the factors affecting the actual precision and stability of optoelectronic and electromagnetic tracking systems in computer-aided surgery under real clinical/intraoperative conditions. A "phantom-skull" with five precisely determined reference distances between marker spheres is used for all measurements. Three optoelectronic and one electromagnetic tracking systems are included in this study. The experimental design is divided into three parts: (1) evaluation of serial- and multislice-CT (computed tomography) images of the phantom-skull for the precision of distance measurements by means of navigation software without a digitizer, (2) digitizer measurements under realistic intraoperative conditions with the factors OR-lamp (radiating into the field of view of the digitizer) or/and "handling with ferromagnetic surgical instruments" (in the field of view of the digitizer) and (3) "point-measurements" to analyze the influence of changes in the angle of inclination of the stylus axis. Deviations between reference distances and measured values are statistically investigated by means of analysis of variance. Computerized measurements of distances based on serial-CT data were more precise than based on multislice-CT data. All tracking systems included in this study proved to be considerably less precise under realistic OR conditions when compared to the technical specifications in the manuals of the systems. Changes in the angle of inclination of the stylus axis resulted in deviations of up to 3.40 mm (mean deviations for all systems ranging from 0.49 to 1.42 mm, variances ranging from 0.09 to 1.44 mm), indicating a strong need for improvements of stylus design. The electromagnetic tracking system investigated in this study was not significantly affected by small ferromagnetic surgical instruments.

Biophysical Phenomena↗

Ankylosing spondylitis, psoriatic arthritis, and reactive arthritis show increased bone resorption, but differ with regard to bone formation.

OBJECTIVE: To test if markers of bone metabolism are altered in patients with seronegative spondyloarthropathies (SSpA). METHODS: We studied biochemical markers of bone resorption and bone formation, osteoprotegerin (OPG), and bone mineral density (BMD) in patients with psoriatic arthritis (PsA), ankylosing spondylitis (AS), and reactive arthritis (ReA) and healthy volunteers. RESULTS: The bone resorption markers urinary deoxypyridinoline and crosslinked telopeptide of collagen-I were significantly increased in patients with AS, PsA, and ReA; in PsA they correlated with the acute phase response (C-reactive protein and erythrocyte sedimentation rate). The bone formation markers were divergent: bone-specific alkaline phosphatase was increased in PsA, but not in AS or ReA. Osteocalcin levels were only elevated in AS. Serum levels of OPG were significantly increased in both AS and PsA. Dual energy x-ray absorptiometry (DEXA) measurements of lumbar spine and femoral neck revealed osteopenia in patients with AS, whereas the DEXA distribution was within normal range in PsA. CONCLUSION: Our data indicate high and, particularly in AS, unbalanced bone turnover in SSpA, consistent with the decrease in BMD found in patients with AS.

Absorptiometry, Photon↗

Guidelines and algorithms: strategies for standardization of referral criteria in diagnostic radiology.

Guidelines can be regarded as special forms of algorithms and have been shown to be useful tools for supporting medical decision making. With the Council Directive 97/43/Euratom recommendations concerning referral criteria for medical exposure have to be implemented into national law of all EU member states. The time- and cost-consuming efforts of developing, implementing, and updating such guidelines are balanced by the acceptance in clinical practice and eventual better health outcomes. Clearly defined objectives with special attention drawn on national and regional differences among potential users, support from organisations with expertise in evidence-based medicine, separated development of the evidence component and the recommendations component, and large-scale strategies for distribution and implementation are necessary. Editors as well as users of guidelines for referral criteria have to be aware which expectations can be met and which cannot be fulfilled with this instrument; thus, dealing with guidelines requires a new form of "diagnostic reasoning" based on medical ethics.

Algorithms↗

Effects of 12 months of recombinant growth hormone therapy on parameters of bone metabolism and bone mineral density in patients on chronic hemodialysis.

BACKGROUND: Renal osteodystrophy is common in patients with chronic renal failure (CRF) on hemodialysis (HD), leading to reduced bone mineral density (BMD) and higher bone fracture incidences. Since growth hormone (GH) and insulin-like growth factor 1 (IGF-1) are known to enhance bone metabolism and BMD, and CRF patients exhibit GH and IGF-1 resistance, recombinant human GH (rhGH) therapy could be beneficial for these patients. METHODS: This study evaluated the effects of a 12-month rhGH therapy on bone metabolism parameters; alkaline phosphatase (AP), osteocalcin (OC), procollagen I carboxyterminal propeptide (PICP), telopeptide ICTP, serum crosslaps, n-terminal propeptide of type III procollagen (PIIINP) and intact parathyroid hormone (iPTH), as well as on BMD of the lumbar spine and the femoral neck in 19 malnourished HD patients (10 females, 9 males) with a mean age of 59.3 +/- 13.4 yrs. Fourteen patients completed the 12-month study. RhGH (0.25 IU/kg) was given subcutaneously 3x/week after each dialysis session. RESULTS: IGF-1 concentrations rose significantly from 169.2 +/- 95.6 to 262.9 +/- 144.4 ng/mL (p<0.01) after 3 months, followed by a slight decline over the next 9 months. PICP as a bone formation marker significantly increased after 3 months from 250.1 +/- 112.6 to 478.5 +/- 235.2 ug/L (p<0.01), as well as PIIINP, whereas OC and bone resorption parameters like ICTP showed only a slight increase (ICTP: 50.3 +/- 18.5 to 70.0 +/- 39.5 ug/L after 3 months (ns)). All bone metabolism parameters slightly declined in the following 9 months, but remained above baseline values after 12 months. PTH rose from 198.0 +/- 139.2 to 456.0 +/- 268.7 ng/ml, p<0.01 after 6 months. BMD of the lumbar spine showed a significant reduction after 3-month rhGH therapy (0.80 +/- 0.17 vs. 0.77 +/- 0.16 g/cm2, p<0.01), but returned to baseline values after 12 months. BMD of the femoral neck remained stable during the entire study. CONCLUSIONS: In summary, 12-month rhGH treatment in patients on chronic HD caused a significant increase in IGF-1, together with an increase in bone turnover. In addition, there was a temporary reduction in BMD of the lumbar spine seen, which returned to baseline values after 12 months.

Absorptiometry, Photon↗