Search PubMed⌕ Search

Biomedical subjects

Frank Vanhaecke

Publications and source records attributed to Frank Vanhaecke.

18 recordsLinked to original sources

Selenium speciation from food source to metabolites: a critical review.

Especially in the last decade, a vast number of papers on Se and its role in health issues have been published. This review gives a brief, critical overview of the main analytical findings reported in these papers. Of particular interest is the Se content in different food sources worldwide and the extent to which their consumption is reflected in the Se content of human tissues and body fluids. Several food sources, both natural (Brazil nuts, garlic, Brassica juncea) and Se-enriched (yeast-based supplements), are discussed as to origin, characteristics, Se metabolism and impact of their consumption on the human body. The continuous development of new and improvement of existing analytical techniques has provided different powerful tools to unravel the Se species and their function. An up-to-date literature study on Se speciation analysis is given, illustrating how analytical chemistry in its different facets aids in the identification of Se compounds and provides insight into the complete metabolic pathway of Se throughout the human body. This review includes a detailed image of the current state-of-the-art of Se speciation analysis in these food sources and in human tissues and body fluids.

Body Fluids↗

Liquid chromatography-mass spectrometry (LC-MS): a powerful combination for selenium speciation in garlic (Allium sativum).

Liquid chromatography (LC) hyphenated with both elemental and molecular mass spectrometry has been used for Se speciation in Se-enriched garlic. Different species were separated by ion-pair liquid chromatography-inductively coupled plasma mass spectrometry (LC-ICP-MS) after hot-water extraction. They were identified by on-line reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry (RPLC-ESI-MS-MS). Se-methionine and Se-methylselenocysteine were determined by monitoring their product ions. Another compound, gamma-glutamyl-Se-methylselenocysteine, shown to be the most abundant form of Se in the garlic, was determined without any additional sample pre-treatment after extraction and without the need for a synthesized standard. Product ions for this dipeptide were detected by LC-ESI-MS-MS for three isotopes of Se-78 Se, 80Se: and 82Se. The method was extended to the species extracted during in-vitro gastrointestinal digestion. Because both Se-methylselenocysteine and gamma-glutamyl-Se-methylselenocysteine have anticarcinogenic properties, their extractability and stability during human digestion are very important. Garlic was also treated with saliva, to enable detection and analysis of species extracted during mastication. Detailed information on the extractability of selenium species by both simulated gastric and intestinal fluid are given, and variation of the distribution of Se among the different species with time is discussed. Although the main species in garlic is the dipeptide gamma-glutamyl-Se-methylselenocysteine, Se-methylselenocysteine is the main compound present in the extracts after treatment with gastrointestinal fluids. Two more, so far unknown compounds were observed in the chromatogram. The extracted species and their transformations were analysed by combining LC-ICP-MS and LC-ESI-MS-MS. In both the simulated gastric and intestinal digests, Se-methionine, Se-methylselenocysteine, and gamma-glutamyl-Se-methylselenocysteine could be determined by LC-ESI-MS-MS by measuring their typical product ions.

Chromatography, Liquid↗

In vitro permeation of chromium species through porcine and human skin as determined by capillary electrophoresis-inductively coupled plasma-sector field mass spectrometry.

Since the species that trigger chromium allergy are not yet known, it is important to gain more of an insight into the mechanism of chromium transport through the skin and into the relationship between chromium allergy and chromium species. In vitro permeation studies with porcine and human skin were performed using a Franz static diffusion cell. Investigations attempted to elucidate (i) which Cr compounds are able to permeate through skin, (ii) the influence the Cr concentration in the donor solution has on the Cr permeation, and (iii) the effect that the time of exposure to the donor solution has on Cr permeation. Capillary electrophoresis hyphenated to inductively coupled plasma-sector field mass spectrometry (CE-ICP-SFMS) was used to separate and quantify the Cr species in the receptor fluid. 50 mmol L(-1) phosphate buffer (pH 2.5) was used for CE separation, and two different electrophoretic runs were carried out (in the positive and negative modes). Pneumatic nebulization (PN)-ICP-SFMS was used in order to quantify the total amount of Cr absorbed by the skin after microwave-assisted acid digestion of the tissue. Cr(VI) was found to pass most easily through the skin. Nevertheless, Cr(VI) was also shown to be absorbed more efficiently by the skin than Cr(III), an observation attributed to a more pronounced rejection of the positively charged Cr(III) ions by the skin barrier. These results were in good agreement with in vitro permeation studies previously reported in the literature in which other analytical techniques were used. Differences observed in the permeation of Cr following the application of aqueous Cr donor solutions and Cr-containing simulated sweat donor solutions are also described.

Acids↗

Classifying wine according to geographical origin via quadrupole-based ICP-mass spectrometry measurements of boron isotope ratios.

The potential of quadrupole-based ICP-MS as a tool for B-isotopic analysis of wines and its usefulness in provenance determinations were assessed. A precision of 0.1-0.25% RSD (corresponding to a relative standard deviation of the mean of three replicate measurements of 0.06-0.12%) was sufficient to establish small differences in the B isotope ratios in wines from different geographical origins. Each sample measurement was bracketed by measurements of a standard and mass bias drift correction made by interpolation. Sample preparation was kept to a minimum to avoid possible fractionation. Dilution of the wine samples by a factor of 100 with 0.65% HNO3 was found to reduce matrix-induced mass discrimination substantially. Wines from three wine-producing regions, Stellenbosch, Robertson, and Swartland, in the Western Cape Province of South Africa, and wines from specific regions in France (Bergerac) and Italy (Valpolicella) were analyzed by ICP-QMS for their B-isotopic compositions. It was concluded that the 11B/10B ratios can be used to characterize wines from different geographical origins. Average 11B/10B ratios in red wines from South Africa (Stellenbosch), France (Bergerac), and Italy (Valpolicella) were found to differ by between 0.5 and 1.5%.

Boron↗

Multi-element analysis of South African wines by ICP-MS and their classification according to geographical origin.

Wines from three important wine-producing regions, Stellenbosch, Robertson, and Swartland, in the Western Cape Province of South Africa, were analyzed by ICP-MS and the elemental composition used in multivariate statistical analysis to classify the wines according to geographical origin. The method is based on the assumption that the provenance soil is an important contributor to the trace element composition of a wine. A total of 40 elements were determined in 40 wines. Of these, 20 elements: Li, B, Mg, Al, Si, Cl, Sc, Mn, Ni, Ga, Se, Rb, Sr, Nb, Cs, Ba, La, W, Tl, and U showed differences in their means across the three areas. In a stepwise discriminant analysis procedure, functions based on linear combinations of the log-transformed element concentrations of Al, Mn, Rb, Ba, W, and Tl were generated to correctly classify wines from each region. In an alternative approach, a pairwise discriminant analysis procedure, not previously used in wine provenance studies, was tested. In this procedure, the classification was done in three steps, with each step classifying a wine as coming from a certain region or not. The combination of elements characterizing wines from a particular region was different in each region. The discriminant functions were based on the following elements: Al, Mn, Rb, Ba, and W for Stellenbosch; Se, Rb, Cs, and Tl for Robertson; and Al, Mn, Rb, Sr, Ba, and Tl for Swartland. After this procedure, the classification of the wines into one of the groups was 100% successful.

Analysis of Variance↗

Identification of the major selenium compound, Se-Methionine, in three yeast (Saccharomyces cerevisiae) dietary supplements by on-line narrowbore liquid chromatography-electrospray tandem mass spectrometry.

On-line monitoring of six Se-compounds was accomplished by using an XTerra MS C18 column coupled to electrospray tandem mass spectrometry (ES-MS-MS). In view of the nature of the compounds, the positively charged ion pairing agent tetraethylammoniumchloride (TEACl) was added to the mobile phase. The HPLC-ES-MS-MS method was optimized with six commercially available Se-compounds. Substitution of the analytical column by the narrowbore type significantly enhanced the sensitivity of the method. We were able to detect the m/z of these six molecules on-line. Furthermore, all product ions could be monitored. The method was applied to three different yeast-based supplements. They were submitted to proteolytic digestion and screened for their Se-content by HPLC-HG-AFS (hydride generation-atomic fluorescence spectrometry). By application of on-line narrowbore HPLC-electrospray tandem mass spectrometry, the main compound present in these three supplements, Se-Methionine, could be measured on its m/z and its product ions. The method can be further extended for on-line measurement of different Se-species in complex matrices

Chromatography, High Pressure Liquid↗

Capillary electrophoresis hyphenated to inductively coupled plasma-sector field-mass spectrometry for the detection of chromium species after incubation of chromium in simulated sweat.

The presence of chromium in chromium-tanned leather represents a considerable health problem since it can lead to chronic allergic contact dermatitis. Apart from trivalent chromium (Cr(III)), which is used for tanning, leather often contains hexavalent chromium (Cr(VI)), resulting from the oxidation of Cr(III) during the tanning process. This study deals with the chromium compounds in simulated sweat when brought into contact with Cr(III) or Cr(VI) and with chromium-tanned leathers. A capillary electrophoresis (CE) method was developed, with inductively coupled plasma-sector field-mass spectrometry (ICP-SF-MS) for element-specific detection. Two different electrophoretic runs, applying once the positive and once the negative polarity mode, were necessary for the detection of positively and negatively charged chromium species. Although sometimes described in the literature, a pre-run derivatization of the chromium-species was not performed here to prevent species transformation. 50 mmol.L(-1) sodium phosphate at a pH of 2.5 was used as CE separation buffer and as make-up liquid for the CE-ICP-SF-MS interface. When applied to simulated sweat samples incubated with Cr(VI), this method showed that methionine is responsible for the reduction of Cr(VI) into Cr(III), which, at its turn, forms a complex with lactic acid. In the case of sweat plus Cr(III), the latter step was also seen. Applied to simulated sweat in contact with leather samples, the method developed showed the presence of the former species among a much more complex pattern.

Chromium↗

Determination of the geographical origin of green coffee by principal component analysis of carbon, nitrogen and boron stable isotope ratios.

In this study we show that the continental origin of coffee can be inferred on the basis of coupling the isotope ratios of several elements determined in green beans. The combination of the isotopic fingerprints of carbon, nitrogen and boron, used as integrated proxies for environmental conditions and agricultural practices, allows discrimination among the three continental areas producing coffee (Africa, Asia and America). In these continents there are countries producing 'specialty coffees', highly rated on the market that are sometimes mislabeled further on along the export-sale chain or mixed with cheaper coffees produced in other regions. By means of principal component analysis we were successful in identifying the continental origin of 88% of the samples analyzed. An intra-continent discrimination has not been possible at this stage of the study, but is planned in future work. Nonetheless, the approach using stable isotope ratios seems quite promising, and future development of this research is also discussed.

Africa↗

Combustive approach for measuring total volatile phosphorus content in landfill gas.

A technique was developed to measure the total gaseous phosphorus content in biogas. The amount of air needed for a neutral to oxidising flame was mixed with the biogas. The gas mixture was burnt in a closed quartz burner and the combustion gasses were bubbled through a nitric acid solution. The phosphate content in the bubbling liquid was determined with sector field ICP-MS. The technique was validated in the lab with phosphine. Afterwards the set-up was installed on a landfill. The total gaseous phosphorus content in the landfill gas, measured with the combustive technique, ranged from 1.65 to 4.44 microg P/m3. At the same time the phosphine concentration in the landfill gas was determined gas chromatographically (GC). The phosphine (PH3) content measured with GC ranged from 7.6 to 16.7 microg PH3-P/m3. Since the phosphine-P content (GC) was consistently higher than the total gaseous phosphorus content (burner/ICP-MS), the hypothesised presence of highly toxic gaseous phosphorus compounds other than phosphine could not be demonstrated.

Chromatography, Gas↗

Hyphenated techniques for speciation of Se in in vitro gastrointestinal digests of Saccharomyces cerevisiae.

A method was developed allowing the separation, detection and identification of Se species extracted from yeast supplements during simulated digestion processes. The in vitro gastric and intestinal digests were studied for their Se compounds by successive high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS) and high-performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-ES-MS-MS) analyses. The conditions for the separation were chosen as to be compatible with both ICP-MS and ES-MS-MS detection. HPLC-ICP-MS was used to screen the extracts for their Se content. By means of HPLC-ES-MS-MS, the compounds extracted were identified on-line according to their retention time, m/ z of the molecular ion and the presence of typical product ions. From these results, it was clear that the main compound extracted by both gastric and intestinal fluid was Se-methionine, which was also the main Se compound extracted by proteolytic digestion from the yeast supplements. Two other minor compounds could be identified as Se-cystine and Se(O)-methionine, a degradation product of Se-methionine.

Chromatography, High Pressure Liquid↗

Validated measurements of the uranium isotopic signature in human urine samples using magnetic sector-field inductively coupled plasma mass spectrometry.

Increased interest in measuring uranium isotope ratios in environmental samples (biological materials, soils, dust particles, water) has come from the necessity to assess the health impact of the use of depleted uranium (DU) based ammunitions during recent military conflicts (e.g., Gulf war, Kosovo) and from the need to identify nondeclared nuclear activities (nuclear safeguards). In this context, very important decisions can arise which have to be based on measurement data of nondisputable uncertainty. The present study describes the certification to 2.5% (k = 2) relative combined uncertainty of n(235U)/n(238U) at ultralow uranium levels (approximately 5-20 pg g(-1)) in human urine samples. After sample decomposition and matrix separation, the isotope ratios were measured by means of a single-detector magnetic sector-field inductively coupled plasma mass spectrometry instrument fitted with an ultrasonic nebulizer. Correction for mass discrimination effects was obtained by means of the certified isotopic reference material IRMM-184. The analytical procedure developed was validated in three complementary ways. First, all major sources of uncertainty were identified and propagated together following the ISO/GUM guidelines. Second, this quality was controlled with a matrix matching NUSIMEP-3 sample (approximately 0.06-0.7% difference from certified). Third, the instrumental part of the procedure was proven to be reproducible from the confirmation of the results obtained for three samples remeasured 7 months later (approximately 1.5% difference). The results obtained for 33 individuals indicated that none seemed to have been exposed to contamination by DU.

Humans↗

Determination of ultra-trace amounts of Fe in AgNO3 solutions by means of isotope dilution analysis applying an inductively coupled plasma mass spectrometer equipped with a dynamic reaction cell.

The development of an ICP-MS method for the determination of ultra-trace amounts of Fe in AgNO(3) solutions using isotope dilution for calibration is described. AgNO(3) solutions are used as raw materials in the production of traditional photographic materials, and it is known that contamination with metal traces can influence the quality of the films thus produced. After adding an appropriate amount of an (54)Fe-enriched spike and permitting isotopic equilibration to take place, Ag was selectively removed from the solutions by precipitation as AgBr. Although to some extent, co-precipitation of Fe is possible under the given circumstances, an incomplete recovery of the analyte element did not affect the accuracy of the results, owing to the use of isotope dilution for calibration. NH(3) was used as a reaction gas in a quadrupole-based ICP-MS instrument, equipped with a dynamic reaction cell (DRC), providing interference-free measurement of the (54)Fe/(56)Fe ratio. The limit of detection (LOD) obtained using this procedure was approximately 0.01 micro g g(-1). This is an excellent value in comparison with the detection limit obtained with the more traditional approach: sample dilution and external calibration with a Fe standard solution (LOD ~1 micro g g(-1)). To validate the method, recovery experiments were carried out. In all instances, a quantitative recovery was established. Finally, the method was applied to the analysis of AgNO(3) solutions. A large variation in Fe concentration was observed. Depending on the Fe content in the samples, relative standard deviations typically ranged between 1 and 14%.

Journal Article↗

Overcoming spectral overlap in isotopic analysis via single- and multi-collector ICP-mass spectrometry.

For isotope ratio applications where an internal isotope ratio precision >0.05-0.1% relative standard deviation suffices, single-collector inductively coupled plasma mass spectrometry (ICPMS) is fit-for-purpose, but for detecting more subtle variations in the natural isotopic composition of a target element, only multi-collector ICPMS (MC-ICPMS) can compete with thermal ionization mass spectrometry (TIMS). While as a result of the extensive sample preparation (analyte isolation) preceding TIMS and the "softer" ionization in vacuum, spectral interferences only seldom occur with this technique, their occurrence is recognized to be the most important drawback of ICPMS. This paper discusses high mass resolution and chemical resolution in a collision or dynamic reaction cell as powerful and versatile means to overcome spectral overlap and illustrates how their introduction has led to a substantial extension of the application range of ICPMS for isotope ratio applications. High mass resolution is the most elegant and straightforward way to overcome the problem of spectral overlap. Offering the possibility to operate the mass analyzer at a higher mass resolution, while at the same time preserving the flat-topped or trapezoidal peak shape required for highly precise isotope ratio measurements, was a challenge for the manufacturers of MC-ICPMS instrumentation. It will be discussed how these apparently contradicting requirements could be fulfilled simultaneously and an overview of the current situation will be given. Chemical resolution in a collision or dynamic reaction cell is an alternative to high mass resolution for overcoming spectral overlap. Real-life examples will be given to illustrate how also this approach can be used to advantage in isotope ratio work. Despite the greater flexibility and straightforwardness of high mass resolution, some situations will be discussed where chemical resolution is to be preferred. Finally, some desires as to future instrumentation are formulated.

Journal Article↗

Detection of metals in proteins by means of polyacrylamide gel electrophoresis and laser ablation-inductively coupled plasma-mass spectrometry: application to selenium.

The capabilities of laser ablation-inductively coupled plasma-mass spectrometry for the detection of trace elements in a gel after gel electrophoresis were systematically studied. Figures of merit, such as limit of detection, linearity, and repeatability, were evaluated for various elements (Li, V, Cr, Mn, Ni, Cu, Zn, As, Se, Mo, Pd, Ag, Cd, Pt, Tl, Pb). Two ablation strategies were followed: single hole drilling, relevant for ablation of spots after two-dimensional (2-D) separations, and ablation with translation, i.e., on a line, relevant for one-dimensional (1-D) separations. This technique was applied to the detection of selenoproteins in red blood cells extracts after a 1-D separation (sodium dodecyl sulfate-polyacrylamide gel electrophoresis) and the detection of selenium-containing proteins in yeast after 2-D electrophoresis (2-DE). The detection procedure was further improved by using the dynamic reaction cell technology, which allowed the removal of the Ar_2(+) interference and hence the use of the most abundant Se isotope, (80)Se. Reaction gases were compared (methane, carbon monoxide, ammonia, oxygen and the combination of argon (collision gas) and hydrogen (reaction gas)). In each instance, the reaction cell parameters were optimized in order to obtain the lowest detection limit for Se (as (80)Se(+), (82)Se(+) or (77)Se(+); and as (80)Se(16)O(+), (82)Se(16)O(+) or (77)Se(16)O(+) with O(2) as the reaction gas). Carbon monoxide was found to offer the best performance. The detection limit with the use of DRC and He as transport gas was 0.07 microg Se g(-1) gel with single hole drilling and 0.15 microg Se g(-1) gel for ablation with translation.

Animals↗

Electrothermal vaporisation ICP-mass spectrometry (ETV-ICP-MS) for the determination and speciation of trace elements in solid samples - A review of real-life applications from the author's lab.

The use of electrothermal vaporisation (ETV) from a graphite furnace as a means of sample introduction in inductively coupled plasma mass spectrometry (ICP-MS) permits the direct analysis of solid samples. A multi-step furnace temperature programme is used to separate the vaporisation of the target element(s) and of the matrix components from one another. Sometimes, a chemical modifier is used to enable a higher thermal pre-treatment temperature, by avoiding premature analyte losses (stabilisation) or promoting the selective volatilisation of matrix components. In almost all instances, accurate results can be obtained via external calibration or single standard addition using an aqueous standard solution. Absolute limits of detection are typically ~1 pg, which corresponds to 1 ng/g for a typical sample mass of 1 mg. Real-life applications carried out in the author's lab are used to illustrate the utility of this approach. These applications aim at trace element determination in industrial and environmental materials. The industrial materials analysed include different types of plastics - Carilon, polyethylene, poly(ethyleneterephtalate) and polyamide - and photo- and thermographic materials. As samples from environmental origin, plant material, animal tissue and sediments were investigated. Some applications aimed at a multi-element determination, while in other, the content of a single, but often challenging, element (e.g., Si or S) had to be measured. ETV-ICP-MS was also used in elemental speciation studies. Separation of Se-containing proteins was accomplished using polyacrylamide gel electrophoresis (PAGE). Subsequent quantification of the Se content in the protein spots was carried out using ETV-ICP-MS. As the volatilisation of methylmercury and inorganic mercury could be separated from one another with respect to time, no chromatographic or electrophoretic separation procedure was required, but ETV-ICP-MS as such sufficed for Hg speciation in fish tissue.

Mass Spectrometry↗