Search PubMed⌕ Search

Biomedical subjects

Frank Dale Morgan

Publications and source records attributed to Frank Dale Morgan.

2 recordsLinked to original sources

Frequency-dependent electroosmosis.

This paper presents a theory for frequency-dependent electroosmosis. It is shown that for a closed capillary the electroosmosis frequency-dependent ratio of DeltaV/DeltaP is constant with increasing frequency until inertial effects become prevalent, at which time DeltaV/DeltaP starts to decrease with increasing frequency. The frequency response of the electroosmosis coupling coefficient is shown to be dependent on the capillary radius. As the capillary radius is made smaller, inertial effects start to occur at higher frequencies. As part of this paper, frequency-dependent electroosmosis is compared to frequency-dependent streaming potentials. In this comparison it is shown that inertial effects start to become more prevalent at higher frequencies for the closed capillary frequency-dependent electroosmosis case than for the frequency-dependent streaming potential case in the same capillary. It is also shown that this difference is due to a second viscosity (transverse) wave that emanates from the velocity zero within the capillary for the electroosmosis case. The second viscosity wave superposes with the viscosity wave that emanates from wall of the capillary to effectively reduce the hydraulic radius of the capillary. Data are presented for a 0.127-mm capillary to support the findings in this paper.

Journal Article↗

Frequency-Dependent Streaming Potentials.

An experimental apparatus and data acquisition system was constructed to measure the streaming potential coupling coefficients as a function of frequency. The purpose of the experiments was to measure, for the first time, the real and imaginary portion of streaming potentials. In addition, the measured frequency range was extended beyond any previous measurements. Frequency-dependent streaming potential experiments were conducted on one glass capillary and two porous glass filters. The sample pore diameters ranged from 1 mm to 34 µm. Two frequency-dependent models (Packard and Pride) were compared to the data. Both Pride's and Packard's models have a good fit to the experimental data in the low- and intermediate-frequency regime. In the high-frequency regime, the data fit the theory after being corrected for capacitance effects of the experimental setup. Pride's generalized model appears to have the ability to more accurately estimate pore sizes in the porous medium samples. Packard's model has one unknown model parameter while Pride's model has four unknown model parameters, two of which can be independently determined experimentally. Pride's additional parameters may allow for a determination of permeability. Copyright 2001 Academic Press.

Journal Article↗