Biomedical subjects
Francis Joffre
Publications and source records attributed to Francis Joffre.
Midterm results of aortic diameter outcomes after thoracic stent-graft implantation for aortic dissection: a multicenter study.
PURPOSE: To evaluate aortic diameter outcomes after stent-graft implantation for aortic dissection in the descending thoracic aorta. METHODS: Fifty patients with type A dissection after ascending aortic surgery (n = 10), type B dissection (n = 34), or intramural hematoma (n = 6) underwent stent-graft repair in 3 centers. Thrombosis and aortic diameter were analyzed by computed tomographic angiography at different levels of the aorta before stent-graft implantation, at discharge, and at follow-up. Measurements were standardized. RESULTS: In all, 67 stent-grafts were implanted for acute (n = 18) and chronic (n = 32) dissection. Stent-graft placement was successfully performed with high technical success (100%) despite 4 major complications (iliac thrombosis in 2 cases, aortic rupture, and a type A dissection) in 3 (6%) patients. Complete thrombosis of the thoracic false lumen was observed in 42% and 63% of cases at discharge and at follow-up (mean 15 months), respectively. At follow-up, the diameters of the entire aorta (mean 5 mm, p < 0.05) and the false lumen (mean 11 mm, p < 0.0001) decreased. Diameters of the abdominal aorta remained stable in association with persistent false lumen perfusion at this level. Aortic diameter results were better in the subgroup of patients with intramural hematoma compared to patients with Marfan syndrome. Three early deaths unrelated to the stent-graft procedure occurred; 2 patients with partial thrombosis of the false lumen died in follow-up secondary to aortic diameter growth. CONCLUSION: Complete thrombosis of the false lumen by stent-graft coverage of the entry tear results in decreased diameter of the entire aorta. In patients with partial thrombosis of the false lumen, the aneurysm continues to enlarge.
Late perforation of a thoracic aortic dacron graft by a metallic stent-graft component.
PURPOSE: To describe a case involving perforation of a previously placed aortic Dacron graft by the uncovered proximal stent of a thoracic stent-graft. CASE REPORT: A 76-year-old man with a surgically treated type A dissection presented with residual type B dissection. Thoracic stent-grafting of the entry site was performed successfully. After 2 years, the patient was admitted for evaluation of a non-pulsating parasternal mass. Computed tomography showed a large, hypodense liquid-like mass affecting the mediastinum up to the subcutaneous tissue. A false aneurysm at the proximal end of the stent-graft was observed arising from an aortic perforation by the uncovered stent. One week later, the mass had almost completely resolved, and the patient has been scheduled for close surveillance. CONCLUSION: This case illustrated the importance of thoroughly examining the long-term durability and compatibility of prosthetic materials.
Post-traumatic venous and systemic air embolism associated with spinal epidural emphysema: multi-slice computed tomography diagnosis.
A 30-year-old man was admitted with chest trauma after a road traffic accident. The patient was paraplegic and suffered from transient monoparesia of the left arm. The chest X-ray revealed a severe right tension pneumothorax and thoracic spine fractures. Emergency right thoracic drainage was carried out followed by angiography. Unfortunately the patient died and an autopsy was not permitted. Consequently post-mortem multi-slice computed tomography (MSCT) was performed, revealing presence of air inside the right cerebral arteries, bilateral pneumothorax accompanied by a severe right tension pneumothorax, bilateral haematic pleural effusion, pneumomediastinum and bilateral lung contusions. Air was also observed within the right coronary artery, ascending aorta and right ventricle. Thoracic and cervical spinal epidural emphysema were diagnosed. Venous air embolism followed by arterial air embolism producing paradoxical embolism was diagnosed. To the best of our knowledge, this is the first case illustrating by post-mortem MSCT such simultaneous complications after chest trauma as spinal epidural emphysema and cerebral and coronary air embolism.
Diagnostic management of pulmonary embolism using clinical assessment, plasma D-dimer assay, complete lower limb venous ultrasound and helical computed tomography of pulmonary arteries. A multicentre clinical outcome study.
The objective of the study was to assess the clinical validity of a non-invasive diagnostic strategy for acute pulmonary embolism using clinical assessment combined with both ELISA D-dimer and complete lower limb ultrasound (US) examination of proximal and distal veins, before single-detector helical computed tomography (CT) of pulmonary arteries. We expected the strategy to have a high diagnostic exclusion power and to safely decrease the number of CT scans. This prospective, multicenter outcome study included 274 consecutive outpatients. All underwent a priori clinical probability, D-dimer and bilateral complete lower limb US assessments. Only patients with a high clinical probability and both tests negative, or positive D-dimer and negative US assessments, underwent CT. This was deemed necessary in 114 patients (42%). At baseline, venous thromboembolism (VTE) was detected in 110 patients (40%), either by US showing proximal (n=65) or distal (n=36) thrombosis, or by CT (n=9). Anticoagulant was withheld in the remaining patients with negative results in both D-dimer and US but a non-high clinical probability (n=59), or in both US and CT (n=90), or with negative US (n=6) and inadequate CT (n=9). All patients underwent a three-month clinical follow-up. VTE occurred in one patient with inadequate CT, yielding an incidence of 0.6% [95% confidence interval: 0.1-3.4]. No patient died from VTE or had major bleeding. Using clinical probability, ELISA D-dimer and complete US before helical CT is a safe strategy resulting in a substantial reduction in CT scans.
Application of the Suchey-Brooks method to three-dimensional imaging of the pubic symphysis.
Age determination is a major field of interest in forensic anthropology. Among the different methods based on macroscopic skeletal study, the Suchey-Brooks method, which analyzes the pubic symphysis, is one of the most reliable. We applied the Suchey-Brooks method to three-dimensional computed tomographic reconstructions of the pubic symphysis. We demonstrated excellent agreement between the results of analysis of bone samples and those of the three-dimensional images, in particular regarding ridges of the articular surface and delimitation of the extremities. The accuracy of age estimation did not significantly differ (Wilcoxon test) between the Suchey-Brooks method applied to bones and the same method applied to CT images. Using high-quality images, this approach seems as reliable as the standard Suchey-Brooks method and offers several advantages: no bone preparation, no damage to bone material, and the possibility of application to living individuals.
FEMIC (Fibromes Embolisés aux MICrosphères calibrées): uterine fibroid embolization using tris-acryl microspheres. A French multicenter study.
PURPOSE: A French multicenter registry was set up to confirm the safety and efficacy of large calibrated tris-acryl gelatin microspheres for embolization of symptomatic fibroids. METHODS: Technical recommendations included embolization using large microspheres (>500 microm) with no secondary embolization agent. Postprocedural pain, clinical improvement and adverse events were prospectively evaluated during a follow-up period of at least 6 months. RESULTS: Eighty-five women complaining of fibroid-related symptoms entered the study. In seven women, a secondary embolization agent was used in addition to microspheres. Complete resolution of menorrhagia was achieved in 84% of women at 24 months and significant uterine and fibroid volume reductions were noted after 6 months (37% and 73%, respectively). Three women experienced definitive amenorrhea (4%) and two women required hysteroscopic resection of a fibroid. Eight women were treated by hysterectomy because of treatment failure. In seven of these women, treatment failure was explained by an additional cause of symptoms including diffuse adenomyosis, endometrial hyperplasia or ovarian artery supply to the fibroids. CONCLUSION: Limited uterine artery embolization using large microspheres has good clinical success rate with low postprocedural pain and complications. Women can expect excellent midterm results with a high level of symptom control and significant fibroid volume reduction. Confidence in the end-point recommended here may require the experience of several cases.
Magnetic resonance imaging contrast-enhanced relaxometry of breast tumors: an MRI multicenter investigation concerning 100 patients.
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using extracellular contrast agents has proved to be useful for the characterization of breast tumors. DCE-MRI has demonstrated a high sensitivity (around 95%) but a rather poor and controversial specificity, varying, according to the different studies, from 45% to 90%. In order to increase (a) the specificity and (b) the robustness of this quantitative approach in multicenter evaluation (five MRI units), a quantitative approach called dynamic relaxometry has been developed. According to the proposed method, the time-dependent longitudinal relaxation rate measured on region of interest of the lesion was calculated during the contrast uptake, after intravenous bolus injection of contrast agent. A specifically developed method was used for fast R(1) measurements. Relaxometry time curves are fitted to the Tofts model allowing the measurement of the parameters describing the enhancement curve (maximum relation rate enhancement, initial, 30-s and 60-s slopes) and the tissue parameters [transfer constant (K(trans) min(-1)) and extracellular extravascular space fraction (v(e))]. Correspondence factorial analysis followed by hierarchical ascendant classification are then performed on the different parameters. Higher K(trans) values were observed in infiltrative ductal carcinomas than in infiltrative lobular carcinomas, in agreement with data published by other groups. Specificity of DCE-MRI has been increased up to 85%, with a sensitivity of 95% with K(trans)/v(e) and enhancement index I (ratio of initial slope by maximum relaxation rate enhancement). A multiparametric data analysis of the calculated parameters opens the way to include quantitative image-based information in new nosologic approaches to breast tumors.
Diagnostic performance of complete lower limb venous ultrasound in patients with clinically suspected acute pulmonary embolism.
A limited ultrasound (US) confined to the popliteal and femoral veins is usually performed to detect deep vein thrombosis (DVT) in patients with clinically suspected acute pulmonary embolism (PE). Our objective was to assess the diagnostic accuracy of complete lower limb US examining both the proximal and distal veins in this setting. In this prospective study, 210 consecutive patients were included. Complete US was performed by independent operators and compared blindly with a reference strategy combining clinical probability, ventilation perfusion scan and pulmonary angiography to a three-month clinical follow-up. Simultaneously, VIDAS D-dimer (DD) assay and helical computed tomography (HCT) of the lungs were assessed independently and blindly. PE was present in 74 patients (35%). Complete US detected DVT in 91 patients (43%), proximal in 51 and distal in 40. Sensitivity and specificity with a 0.95 confidence interval were respectively 0.93 [0.85 - 0.97] and 0.84 [0.77 - 0.89]. Limited US detected DVT in only 46 patients (22%). Sensitivity and specificity were respectively 0.55 [0.44 - 0.66] and 0.96 [0.92 - 0.98]. For DD they were 0.92 [0.83 - 0.96] and 0.24 [0.17 - 0.32] and for HCT 0.84 [0.73 - 0.90] and 0.87 [0.80 - 0.92]. Complete lower limb US has higher sensitivity and capacity to exclude PE than limited US, but a slightly lower specificity. Complete US results also compared favourably with those of HCT and DD. The utility of including this method in diagnostic strategies for PE needs to be assessed in cost-effectiveness analysis and in outcome studies.
Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations.
The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean+/-SD value: 34+/-12.9 vs 43+/-13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean+/-SD value: 17+/-2.75 vs 14+/-3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening ( n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%).
Midterm outcomes of thoracic aortic stent-grafts: complications and imaging techniques.
PURPOSE: To evaluate the midterm outcomes of thoracic aortic stent-grafting and the performance of computed tomographic angiography (CTA), radiography, and magnetic resonance angiography (MRA) in endograft surveillance. METHODS: Forty-seven patients with traumatic thoracic aortic ruptures (n=16), aneurysms (n=14), false aneurysms (n=3), penetrating ulcers (n=3), and dissections (n=11) treated with stent-grafts were monitored in follow-up using chest radiography and CTA in all patients and MRA in 23 patients. Two perpendicular maximal aortic diameters, the sum of these diameters, and the elliptical cross-sectional area were determined and compared to baseline for the entire group and in subgroup analyses according to lesion type. CTA, MRA, and radiography were compared for their ability to detect endoleak, monitor stent-graft configuration, and measure aortic diameters. RESULTS: The mortality rate was 8.5%. Severe complications were observed in 14.8% (6% neurological complications); 12 (25.5%) patients had primary endoleaks. Over a mean 11-month follow-up (range 0.25-46 months), the aortic diameters decreased for all patients without endoleak (p<0.001). In the diameter/area subgroup analyses, only the traumatic rupture cohort demonstrated significant decreases in all 4 measurements. CTA and MRA measurements correlated well, but chest radiography was superior to both for visualizing stent-graft shape. In terms of endoleak detection, MRA missed only 1 (12.5%) endoleak (type II) seen on CTA; there were no false positive results with MRA. CONCLUSIONS: Morbidity and mortality observed after thoracic stent-grafting are acceptable. Radiography is better for monitoring stent-graft conformation, while CTA provides the best overall morphological information. The performance of MRA in endoleak detection is encouraging.
Adolescents with partial growth hormone (GH) deficiency develop alterations of body composition after GH discontinuation and require follow-up.
It is now a consensus to resume GH treatment in adolescents with severe GH deficiency (GHD) at retesting to prevent the occurrence of adult GHD syndrome. However, we do not have any data on the follow-up of adolescents with nonsevere GHD at completion of treatment. This report presents preliminary data from a 1-yr prospective study that includes the first 91 patients retested. Anthropometric data, IGF-I and IGF binding protein-3 levels, glycemia and insulinemia, lipid profile, and body composition using dual x-ray absorptiometry and abdominal computed tomography scan were recorded at completion of GH treatment and 1 yr later. Body composition was significantly different at both evaluations, with increased total body fat and decreased lean body mass in the partial GHD group vs. the normal group. Moreover, these alterations worsened after 1 yr without GH in the partial GHD group, whereas there were no modifications in the normal group. We did not find any metabolic alterations such as elevated triglyceride, total cholesterol, or insulin levels. Adolescents with reconfirmed partial GHD exhibit alterations in body composition after 1 yr without GH, whereas those retested normal do not. These changes are similar to those described in severe GHD, although less marked, and justify a precise follow-up.
[Imaging of the aorta].
Imaging of the aorta has greatly been improved by the recent development of helical computed tomography and magnetic resonance imaging. This report develops typical features of variety of aortic diseases including dissections, aneurysms, aortic rupture, non aneurismal atherosclerotic diseases, arteritis, aortic coarctation and postoperative aorta. The place for the different imaging modalities is discussed according to the disease involved.
Endovascular treatment of aberrant systemic arterial supply to normal basilar segments of the right lower lobe: case report and review of the literature.
We report the case of a 17-year-old man with acute chest pain due to a partial thrombosis of a pseudosequestration. Unlike a true sequestration, there was a normal bronchial distribution and the involved lung parenchyma was normal on CT scan. A therapeutic transarterial embolization of the aberrant systemic artery from the proximal abdominal aorta was performed successfully. The patient did not suffer from further chest pain during the follow-up of 12 months. A contrast-enhanced CT scan 4 months later demonstrated complete occlusion of the embolized aberrant artery. Our case represents an alternative treatment to surgery for this rare abnormality.
Congenital pelvic arteriovenous malformation in male patients: a rare cause of urological symptoms and role of embolization.
OBJECTIVES: Congenital pelvic arteriovenous malformations (pAVM) are rare in male patients. The purpose of our study was to obtain information about the presenting symptoms, differential diagnosis, radiological diagnosis and therapy. PATIENTS AND METHODS: The record of two men with congenital pAVM were reviewed to evaluate the initial symptomatology, diagnostic examinations and findings, therapeutic procedures and clinical outcome. Furthermore, our data are compared to the findings of all men reported in the literature. RESULTS: Including the two cases reported by us, the data on 17 men with congenital pAVM could be analyzed. Most men presented with unspecific symptoms like pelvic discomfort, pain, impotence or dysuria. The radiological diagnosis was established by magnetic resonance imaging (MRI) or by computed tomography (CT) and was confirmed by angiography in all cases. Therapy consisted of surgical excision in nine cases, embolization in four cases, embolization and surgery in three cases and medical supervision in one case. CONCLUSION: Pelvic arteriovenous malformations in male patients are rare. Because of the lack of specific symptoms, they are difficult to diagnose. CT or MRI and arteriography make the diagnosis. Intra-arterial embolization can be considered as the first line treatment.
A useful endovascular technique for treating modular limb disconnection in a bifurcated stent-graft.
PURPOSE: To report a technique for treating a type III endoleak owing to disconnection of an iliac graft limb from a modular aortic stent-graft. TECHNIQUE: A hydrophilic guidewire is introduced via a homolateral femoral access and passed through the thrombosed iliac extension. Once the errant graft limb is recanalized, wire exchange for an extra stiff guidewire facilitates passage of an angioplasty balloon into the stent. Inflated under low pressure, the balloon is used to push the thrombosed limb retrograde into the aneurysm sac. With the aortoiliac axis restored, a new covered stent can be deployed. CONCLUSIONS: This approach is one of several that may be used to treat a type III endoleak arising from a disconnected and occluded stent-graft limb. It avoids the bleeding complications of thrombolysis and restores the aortoiliac axis so that another stent-graft may be implanted to re-exclude the aneurysm.
Preliminary results of a new expanded-polytetrafluoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt procedures.
OBJECTIVE: The purpose of our study was to evaluate the feasibility and the safety of transjugular intrahepatic portosystemic shunts (TIPS) with a new expanded-polytetrafluoroethylene-covered stent and the influence of the covering on occlusion rate. SUBJECTS AND METHODS: Twenty cirrhotic patients (57 +/- 11 years old) admitted with a history of esophageal variceal bleeding (n = 11), refractory ascites (n = 5), or both (n = 4) were included. Five of the patients were treated for TIPS revision, and 15 as de novo TIPS placements. The endoprostheses used were composed of a 2-cm noncovered nitinol stent and a 4- to 8-cm expanded-polytetrafluoroethylene graft covering, and were placed from the portal vein to the ostium of the hepatic vein. Patients underwent Doppler sonography at discharge and again at 1, 3, 6, 9, 12, and 15 months and underwent venography with portosystemic pressure gradient measurement at 6 months and whenever necessary. RESULTS: At the time of this writing, complications included three TIPS restenoses and one recurrent ascites successfully treated by balloon dilation, two cases of segmentary liver ischemia, and one patient with encephalopathy that required shunt reduction. After TIPS placement, the portosystemic pressure gradient dropped from 18 +/- 5 to 5 +/- 4 mm Hg. Primary and secondary patency rates were 80% and 100%, respectively, at 387 days. CONCLUSION: These results clearly show the feasibility of TIPS placement with the Gore TIPS endoprosthesis stent-graft and its improved patency compared with results in the literature for bare stents. These preliminary results must be certified further with randomized comparative trials between covered and noncovered TIPS stents.
Stent-graft treatment of penetrating thoracic aortic ulcers.
PURPOSE: To evaluate the efficacy of stent-graft placement for the treatment of penetrating thoracic aortic ulcers. METHODS: Ten patients (7 men; mean age 73.8 years, range 69-79) were treated for penetrating thoracic aortic ulcers using Talent or Excluder stent-grafts. Preoperative examinations included computed tomographic angiography (CTA), transesophageal echography, and digital subtraction angiography (DSA). Follow-up included predischarge multimodal imaging and periodic CTA scans after discharge. Endoleaks, aortic diameter changes, and clinical complications were tracked. RESULTS: Technical success was achieved in 100%, but 1 major neurological complication led to death 3 months after the procedure. Radiological follow-up detected 4 early, endoleaks (3 type I and a type II), all of which spontaneously regressed, and 1 secondary type II endoleak. The mean aortic diameter decreased by 22% over a mean 9-month follow-up. CONCLUSIONS: Aortic ulcers are potentially lethal lesions. Considering its low morbidity and mortality, endovascular repair could widen the treatment options for these lesions.