Search PubMed⌕ Search

Biomedical subjects

Francesco Romeo

Publications and source records attributed to Francesco Romeo.

38 records · Page 3Linked to original sources

Statins modulate oxidized low-density lipoprotein-mediated adhesion molecule expression in human coronary artery endothelial cells: role of LOX-1.

LOX-1, a receptor for oxidized low-density lipoprotein (ox-LDL), plays a critical role in endothelial dysfunction and atherosclerosis. LOX-1 activation also plays an important role in monocyte adhesion to endothelial cells. A number of studies show that 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins) reduce total LDL cholesterol and exert a cardioprotective effect. We examined the modulation of LOX-1 expression and its function by two different statins, simvastatin and atorvastatin, in human coronary artery endothelial cells (HCAECs). We observed that ox-LDL (40 microg/ml) treatment up-regulated the expression of E- and P-selectins, VCAM-1 and ICAM-1 in HCAECs. Ox-LDL mediated these effects via LOX-1, since antisense to LOX-1 mRNA decreased LOX-1 expression and subsequent adhesion molecule expression. Pretreatment of HCAECs with simvastatin or atorvastatin (1 and 10 microM) reduced ox-LDL-induced expression of LOX-1 as well as adhesion molecules (all P < 0.05). A high concentration of statins (10 microM) was more potent than the low concentration (1 microM) (P < 0.05). Both statins reduced ox-LDL-mediated activation of the redox-sensitive nuclear factor-kappaB (NF-kappaB) but not AP-1. These observations indicate that LOX-1 activation plays an important role in ox-LDL-induced expression of adhesion molecules. Inhibition of expression of LOX-1 and adhesion molecules and activation of NF-kappaB may be another mechanism of beneficial effects of statins in vascular diseases.

Atorvastatin↗

[Cardiac MRI with SENSE technology: study of ventricular and valvular functionality in 30 patients].

PURPOSE: The latest innovation in MR imaging is SENSE (SENSitivity Encoding), a technology providing an important solution for the time necessary for signal encoding. In the SENSitivity Encoding (SENSE) approach, an array of multiple, simultaneously operated receiver coils is used for signal acquisition. In particular, the efficacy of SENSE technology is able to reduce the number of phase encodings by a factor (named R factor or Reduction factor) and to evaluate the same k space with fewer readout lines obtaining higher spatial and temporal resolution. MATERIALS AND METHODS: An heterogeneous group of 30 patients with a variety of clinically proven diagnoses underwent Cardiac MR with SENSE technology to evaluate the technique's diagnostic efficacy. The sequences used were "Balanced" Ultrafast Gradient Echo (B-FFE) characterised by a hyper-intense blood signal with multislice multiphase and single slice multiphase acquisitions. RESULTS: In addition to reducing scan times, SENSE technology improved spatial and temporal resolution (40 frames/cardiac cycle) providing optimal dynamic evaluation of valve structures and wall kinesis. Furthermore, the use of the SENSE technique with B-FFE sequences (sB-FFE) enabled the qualitative evaluation of abnormal blood movements and transvalvular flows. CONCLUSIONS: The considerable time savings allowed by SENSE technology and the clear improvement in image quality constitute a step forward in cardiac MR imaging. The possibility of executing morphologic, dynamic, perfusional and spectroscopic studies in the same MR examination session with short acquisition times and good image quality are becoming more feasible.

Adult↗