Search PubMed⌕ Search

Biomedical subjects

Frances Chan

Publications and source records attributed to Frances Chan.

4 recordsLinked to original sources

Effect of various normalization methods on Applied Biosystems expression array system data.

BACKGROUND: DNA microarray technology provides a powerful tool for characterizing gene expression on a genome scale. While the technology has been widely used in discovery-based medical and basic biological research, its direct application in clinical practice and regulatory decision-making has been questioned. A few key issues, including the reproducibility, reliability, compatibility and standardization of microarray analysis and results, must be critically addressed before any routine usage of microarrays in clinical laboratory and regulated areas can occur. In this study we investigate some of these issues for the Applied Biosystems Human Genome Survey Microarrays. RESULTS: We analyzed the gene expression profiles of two samples: brain and universal human reference (UHR), a mixture of RNAs from 10 cancer cell lines, using the Applied Biosystems Human Genome Survey Microarrays. Five technical replicates in three different sites were performed on the same total RNA samples according to manufacturer's standard protocols. Five different methods, quantile, median, scale, VSN and cyclic loess were used to normalize AB microarray data within each site. 1,000 genes spanning a wide dynamic range in gene expression levels were selected for real-time PCR validation. Using the TaqMan assays data set as the reference set, the performance of the five normalization methods was evaluated focusing on the following criteria: (1) Sensitivity and reproducibility in detection of expression; (2) Fold change correlation with real-time PCR data; (3) Sensitivity and specificity in detection of differential expression; (4) Reproducibility of differentially expressed gene lists. CONCLUSION: Our results showed a high level of concordance between these normalization methods. This is true, regardless of whether signal, detection, variation, fold change measurements and reproducibility were interrogated. Furthermore, we used TaqMan assays as a reference, to generate TPR and FDR plots for the various normalization methods across the assay range. Little impact is observed on the TP and FP rates in detection of differentially expressed genes. Additionally, little effect was observed by the various normalization methods on the statistical approaches analyzed which indicates a certain robustness of the analysis methods currently in use in the field, particularly when used in conjunction with the Applied Biosystems Gene Expression System.

Algorithms↗

Large scale real-time PCR validation on gene expression measurements from two commercial long-oligonucleotide microarrays.

BACKGROUND: DNA microarrays are rapidly becoming a fundamental tool in discovery-based genomic and biomedical research. However, the reliability of the microarray results is being challenged due to the existence of different technologies and non-standard methods of data analysis and interpretation. In the absence of a "gold standard"/"reference method" for the gene expression measurements, studies evaluating and comparing the performance of various microarray platforms have often yielded subjective and conflicting conclusions. To address this issue we have conducted a large scale TaqMan Gene Expression Assay based real-time PCR experiment and used this data set as the reference to evaluate the performance of two representative commercial microarray platforms. RESULTS: In this study, we analyzed the gene expression profiles of three human tissues: brain, lung, liver and one universal human reference sample (UHR) using two representative commercial long-oligonucleotide microarray platforms: (1) Applied Biosystems Human Genome Survey Microarrays (based on single-color detection); (2) Agilent Whole Human Genome Oligo Microarrays (based on two-color detection). 1,375 genes represented by both microarray platforms and spanning a wide dynamic range in gene expression levels, were selected for TaqMan Gene Expression Assay based real-time PCR validation. For each platform, four technical replicates were performed on the same total RNA samples according to each manufacturer's standard protocols. For Agilent arrays, comparative hybridization was performed using incorporation of Cy5 for brain/lung/liver RNA and Cy3 for UHR RNA (common reference). Using the TaqMan Gene Expression Assay based real-time PCR data set as the reference set, the performance of the two microarray platforms was evaluated focusing on the following criteria: (1) Sensitivity and accuracy in detection of expression; (2) Fold change correlation with real-time PCR data in pair-wise tissues as well as in gene expression profiles determined across all tissues; (3) Sensitivity and accuracy in detection of differential expression. CONCLUSION: Our study provides one of the largest "reference" data set of gene expression measurements using TaqMan Gene Expression Assay based real-time PCR technology. This data set allowed us to use an alternative gene expression technology to evaluate the performance of different microarray platforms. We conclude that microarrays are indeed invaluable discovery tools with acceptable reliability for genome-wide gene expression screening, though validation of putative changes in gene expression remains advisable. Our study also characterizes the limitations of microarrays; understanding these limitations will enable researchers to more effectively evaluate microarray results in a more cautious and appropriate manner.

Gene Expression Profiling↗

Long versus short oligonucleotide microarrays for the study of gene expression in nonhuman primates.

The high degree of sequence similarity between human and nonhuman primate (NHP) genomic DNA suggests that human genome sequence-based DNA microarrays may be used effectively to study gene expression in NHP disease models. In the present study, two distinct commercially available human genome microarray platforms, the Affymetrix HG U133A GeneChip System utilizing Human Genome U133A GeneChips and the Applied Biosystems Expression Array System utilizing the Human Genome Survey Microarray, were used to identify and characterize gene expression changes in the anterior cerebellum of a macaque monkey model of human alcoholism. The Affymetrix microarray consists of eleven short oligonucleotide probe sets for each gene while the Applied Biosystems Microarray uses a single long oligonucleotide per gene. Cross-mapping of probes revealed a total of 11,542 genes that are represented on both microarray platforms. Absolute measures of gene expression ("present calls") from the cerebellum RNA samples were 65-70% (Applied Biosystems Expression Array System) and 27-30% (AffymetrixGeneChip System) among these common gene targets. Analysis of variance (ANOVA; p<0.05; >1.2 fold change; detected on at least 50% of the arrays) indicated 932 and 515 differentially expressed genes for the Applied Biosystems and Affymetrix microarrays, respectively. Significance analysis of microarrays (SAM) identified 255 significant genes at 5% false discovery rate (FDR) for the Applied Biosystems data set and five significant genes at 60% FDR (minimum FDR) for the Affymetrix data set. TaqMan assay-based real-time PCR validation of a number of differentially-expressed genes yielded results that agreed well with the array data in the majority of comparisons. This study demonstrates that human sequence-based DNA arrays can be used effectively to detect differential gene expression in an NHP disease model and provides evidence that the use of this long oligonucleotide-based microarray platform may be more suitable for cross-species gene expression studies than a short oligonucleotide-based system.

Alcohol Drinking↗

The involvement of calcineurin in acetylcholine receptor redistribution in muscle.

In this study the intracellular signaling involved in acetylcholine receptor (AChR) redistribution in muscle was investigated. In cultured Xenopus embryonic muscle cells, both the dispersal of preexisting AChR clusters and the induction of new AChR clusters by growth factor-coated polystyrene beads were inhibited by two specific antagonists of the ser/thr phosphatase calcineurin (CaN), Cyclosporin A, (CsA) and FK-506, but not by KN-93 that blocks CaM kinases. Moreover, CaN inhibition decreased AChR clustering in Xenopus muscle cells by beads coated with antibodies that cross-link and activate the agrin receptor MuSK (muscle-specific kinase) and reduced the agrin-induced tyrosine phosphorylation of MuSK in cultured mouse (C2) myotubes. Last, the length and the number of AChR clusters generated by agrin in C2 myotubes were decreased by treatment with CsA, but not KN-93, and following the forced expression of a dominant negative CaN mutant in these cells, but not wild-type CaN or reporter green fluorescent protein. Collectively, our results support a role for CaN signaling in the redistribution of AChRs in muscle induced by synaptogenic signals.

Agrin↗