Search PubMed⌕ Search

Biomedical subjects

Folkert J Ten Cate

Publications and source records attributed to Folkert J Ten Cate.

At least 19 recordsLinked to original sources

Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy.

AIMS: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) > or =60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Sixty patients (72% males, mean age 59 +/- 10 years) who were referred for CRT according to the ACC/ESC guidelines were enrolled in the study. All patients underwent spectral PW-TDI before and 1 year after CRT. Two left ventricular (LV) dyssynchrony time intervals, T(O) and T(P) (time to onset and peak of LV myocardial velocity, respectively), LSD were recorded. Left ventricular dyssynchrony was defined as LSD > or =60 ms. Clinical response was defined as an improvement in >1 NYHA class plus improvement in 6-min walk distance (6MWD) > or =25%, echocardiographic response was defined as a > or =15% reduction in LV end-systolic volume (LV-ESV). One year after CRT, 50 patients (83%) were clinical responders and 47 patients (78%) were echocardiographic responders. Both T(O) and T(P) LV dyssynchrony indices failed to predict echocardiographic CRT outcome. In addition, there were no significant differences between 'synchronous' and 'dyssynchronous' patient populations at baseline or follow-up in either clinical (NYHA class and 6MWD) or echocardiographic (LV ejection fraction, LV end-diastolic, and end-systolic) variables. CONCLUSION: The great majority of patients referred for CRT benefit clinically from it. However, spectral PW-TDI failed to predict CRT outcome. When PW-TDI dyssynchrony was applied for selection of proper CRT patients, up to 80-86% of the patients with synchronous LSD that had proven clinical and echocardiographic benefit from CRT would have been denied CRT.

Cardiac Pacing, Artificial↗

Cardiac involvement in adults with m.3243A>G MELAS gene mutation.

Cardiac data in adults with mitochondrial encephalomyopathy, lactic acidosis, and strokelike episodes (MELAS syndrome) or asymptomatic gene carriers with the mitochondrial deoxyribonucleic acid adenine-to-guanine point mutation at nucleotide pair 3243 are scarce. Twelve subjects (mean age 35 +/- 13 years), 8 with MELAS syndrome (patients) and 4 asymptomatic gene carriers (carriers), were enrolled in the study. Each subject underwent electrocardiography, exercise testing, Holter monitoring, echocardiography, and genetic and biochemical analysis for respiratory chain enzyme activity (complex I rest activity) in skeletal muscle. On electrocardiography and Holter monitoring, none of the subjects had evidence of preexcitation, cardiac arrhythmias, or conduction abnormalities. Patients had significantly lower (42 +/- 17% from normal vs 103 +/- 14%, p <0.02) exercise tolerance. All but 1 of the patients and none of the gene carriers had ragged red fibers on muscle biopsy. The mean percentage of gene mutation in skeletal muscle tended to be higher in patients (53 +/- 19%, range 19% to 73%) compared with carriers (33 +/- 20%, range 15% to 62%). Mean complex I rest activity in patients (36 +/- 18%, range 10% to 58%) was significantly (p <0.01) lower compared with carriers (120 +/- 60%, range 72% to 205%). Left ventricular (LV) abnormalities were confined to patients with MELAS syndrome. Two patients had LV hypertrophy, 5 had LV systolic abnormalities, and 5 had LV diastolic dysfunction. Apart from 1 patient with an isolated LV diastolic abnormality, all patients with LV abnormalities had ragged red fibers. Patients with abnormal systolic LV function had a trend toward a higher percentage of mutated skeletal muscle (59.7 +/- 10.7% vs 35.8 +/- 21.3%, p <0.10) and significantly lower complex I rest activity (26.7 +/- 14.0% vs 97.8% +/- 57.9, p <0.01). In conclusion, none of the MELAS gene carriers had cardiac abnormalities, whereas most patients with the MELAS phenotype, particularly those with ragged red fibers, had LV involvement.

Adolescent↗

Usefulness of ultrasound contrast agent to improve image quality during real-time three-dimensional stress echocardiography.

Dobutamine stress echocardiography is an accepted tool for the diagnosis of coronary artery disease. Some investigators have claimed that 3-dimensional imaging improves the diagnostic accuracy of dobutamine stress echocardiography. The purpose of the present investigation was to examine the role of contrast echocardiography in the improvement of segmental quality and interobserver agreement during stress real-time 3-dimensional echocardiography (RT3DE). The study comprised 36 consecutive patients with stable chest pain referred for routine stress testing. Three-dimensional images were acquired with an RT3DE system with an X4 matrix-array transducer. All available reconstructed 2-dimensional segments were graded as optimal, good, moderate, or poor. Wall motion was scored as normal, mild hypokinesia, severe hypokinesia, akinesia, or dyskinesia. At peak stress, 466 of the 612 segments (76%) could be analyzed during conventional RT3DE. With contrast-enhanced RT3DE, the number of available segments increased to 553 (90%). The image quality index during conventional RT3DE was 2.2, whereas with contrast-enhanced RT3DE, it was 3.1. With conventional RT3DE, 2 independent observers agreed on the diagnosis of myocardial ischemia in 85 of 108 coronary territories (79%, kappa = 0.26). With contrast-enhanced RT3DE, agreement increased to 95 of 108 coronary territories (88%, kappa = 0.59). Study agreement on myocardial ischemia was present in 26 of 36 studies (72%, kappa = 0.43) with conventional RT3DE and in 32 of 36 studies (89%, kappa = 0.77) with contrast-enhanced RT3DE. In conclusion, during stress RT3DE, contrast-enhanced imaging significantly decreases the number of poorly visualized myocardial segments and improves interobserver agreement for the diagnosis of myocardial ischemia.

Cardiotonic Agents↗

Septal ablation in hypertrophic obstructive cardiomyopathy improves systolic myocardial function in the lateral (free) wall: a follow-up study using CMR tissue tagging and 3D strain analysis.

AIMS: Alcohol septal ablation (ASA) has been successful in the treatment of symptomatic hypertrophic obstructive cardiomyopathy (HOCM). The aim of this study is to evaluate the effects of ethanol-induced myocardial infarcts on regional myocardial function using cardiac magnetic resonance (CMR) tissue tagging and 3-dimensional (3D) strain analysis. METHODS AND RESULTS: In nine patients (age 52+/-15 years) who underwent ASA, CMR was performed prior to and 6 months after the procedure. Regional myocardial mass was evaluated using cine imaging. Myocardial tagging was used to calculate systolic 3D myocardial strain values. These strain values were used to calculate the shortening index (SI), a robust parameter for myocardial contraction. Maximum end-systolic (ES) SI and systolic SI rate were quantified in three circumferential segments: septum, adjacent, and remote (lateral) myocardium. Compared with baseline, septal and non-septal mass decreased at follow-up (from 72+/-27 to 59+/-21 g; P=0.008 and from 131+/-34 to 109+/-30 g; P=0.008, respectively). In the septum, maximum ES SI and SI rate remained unchanged after ASA. In adjacent myocardium, ES SI remained unchanged, whereas SI rate improved (from -56.5+/-21.1 to -70.0+/-16.7%/s; P=0.02). Both ES SI and SI rate improved significantly in remote myocardium (from -16.9+/-2.8 to -18.8+/-3.2%; P=0.02 and from -70.3+/-9.2 to -86.1+/-15.0%/s; P=0.01, respectively). CONCLUSION: Reduction of left ventricular (LV) outflow tract obstruction in symptomatic HOCM is associated with a significant reduction in myocardial mass and improvement of intramural systolic function in the lateral (remote) wall, indicating reversed LV remodelling.

Adolescent↗

Contrast harmonic intravascular ultrasound: a feasibility study for vasa vasorum imaging.

OBJECTIVE: We sought to investigate feasibility of vasa vasorum imaging using the novel technique of contrast harmonic intravascular ultrasound. METHODS: Prototype intravascular ultrasound (IVUS) instrumentation was developed for the sensitive detection of micro-bubble contrast agents. The technique, "harmonic" imaging, involves transmitting ultrasound at 20 MHz (fundamental) and detecting contrast signals at 40 MHz (second harmonic). Phantom experiments were conducted to investigate the detection of a small vessel in the wall surrounding a larger vessel. In vivo experiments were conducted in atherosclerotic rabbit abdominal aortas. RESULTS: The phantom experiments showed improved small vessel detection in harmonic mode relative to fundamental mode. For the in vivo experiments, harmonic imaging enabled the visualization of contrast agent outside the aortic lumen through a statistically significant (P < 0.001) enhancement of image power, consistent with the detection of adventitial microvessels. These microvessels were not detected in fundamental imaging mode. CONCLUSIONS: These results indicate the feasibility of contrast harmonic intravascular ultrasound as a new technique for vasa vasorum imaging.

Animals↗

Rapid and accurate measurement of left ventricular function with a new second-harmonic fast-rotating transducer and semi-automated border detection.

Measurement of left ventricular (LV) volume and function are the most common clinical referral questions to the echocardiography laboratory. A fast, practical, and accurate method would offer important advantages to obtain this important information. To validate a new practical method for rapid measurement of LV volume and function. We developed a continuous fast-rotating transducer, with second-harmonic capabilities, for three-dimensional echocardiography (3DE). Fifteen cardiac patients underwent both 3DE and magnetic resonance imaging (reference method) on the same day. 3DE image acquisition was performed during a 10-second breath-hold with a frame rate of 100 frames/sec and a rotational speed of 6 rotations/sec. The individual images were postprocessed with Matlab software using multibeat data fusion. Subsequently, with these images, 12 datasets per cardiac cycle were reconstructed, each comprising seven equidistant cross-sectional images for analysis in the new TomTec 4DLV analysis software, which uses a semi-automated border detection (ABD) algorithm. The ABD requires an average analysis time of 15 minutes per patient. A strong correlation was found between LV end-diastolic volume (r = 0.99; y = 0.95x - 1.14 ml; SEE = 6.5 ml), LV end-systolic volume (r = 0.96; y = 0.89x + 7.91 ml; SEE = 7.0 ml), and LV ejection fraction (r = 0.93; y = 0.69x + 13.36; SEE = 2.4%). Inter- and intraobserver agreement for all measurements was good. The fast-rotating transducer with new ABD software is a dedicated tool for rapid and accurate analysis of LV volume and function.

Adult↗

Intracardiac echocardiography guidance during percutaneous transluminal septal myocardial ablation in patients with obstructive hypertrophic cardiomyopathy.

BACKGROUND: Percutaneous transluminal septal myocardial ablation (PTSMA) recently emerged as an alternative to myectomy for hypertrophic obstructive cardiomyopathy (HOCM) patients with drug-refractory symptoms. The target septal branch selection is a main point to achieve the therapeutic result. METHODS AND RESULTS: We report about PTSMA performed using intracardiac echocardiography (ICE) to guide the procedure in 9 symptomatic HOCM patients. The target septal branch was chosen on the basis of the risk-area visualized using ICE after injection of a contrast agent. During alcohol administration a backscattered signal enhancement of the infarcted area was detected. The procedures were uncomplicated and effective to reduce the gradient from 78.9+/-20.4 mmHg to 7.8+/-7.9 mmHg (p<0.0001). CONCLUSIONS: In this initial experience ICE monitoring during PTSMA was safe and provided high quality and continuous imaging of the treated segment of the septum during the whole procedure.

Adult↗

Myocardial wall thickness predicts recovery of contractile function after primary coronary intervention for acute myocardial infarction.

OBJECTIVES: We sought to determine whether end-diastolic wall thickness (EDWT) can predict recovery of regional left ventricular contractile function after percutaneous coronary intervention (PCI). BACKGROUND: Regional contractile function does not recover in all patients after PCI for acute myocardial infarction (AMI). Prediction of functional recovery after AMI may help in clinical decision making. METHODS: Forty consecutive patients with AMI were studied with left ventricular contrast echocardiography for accurate wall thickness and function measurement and myocardial perfusion immediately after and two months following PCI. RESULTS: Out of 640 segments, 175 (27%) dysfunctional segments in the infarct territory were analyzed for EDWT, wall function, and perfusion. One hundred and three (59%) dysfunctional segments presented with an EDWT <11 mm and 72 (41%) presented with an EDWT > or =11 mm. Perfusion (partial or complete) was present in 63 segments with an EDWT <11 mm (61%) and 71 segments with an EDWT > or =11 mm (99%) (p < 0.001). At two months' follow-up, 66 of 72 segments with an EDWT > or =11 mm (92%) improved, whereas only 35 of 103 of the dysfunctional segments with an EDWT <11 mm (34%) improved (p < 0.0001). CONCLUSIONS: Wall thickness is an easy parameter to predict recovery of function after revascularization. Moreover, combining EDWT and perfusion, segments with an EDWT > or =11 mm, and presence of perfusion have the highest chance of recovery; segments with an EDWT <11 mm and perfusion have an intermediate chance of recovery. In segments with an EDWT <11 mm and no perfusion, chances of recovery are very low.

Adult↗

Permanent pacing for complete atrioventricular block after nonsurgical (alcohol) septal reduction in patients with obstructive hypertrophic cardiomyopathy.

Nonsurgical septal reduction is a newly developed, catheter-based therapeutic option for patients with drug-refractory obstructive hypertrophic cardiomyopathy. A circumscribed septal infarction is generated to reduce the left ventricular outflow tract gradient. The spontaneous regression of complete atrioventricular block after the procedure and the main complication of the intervention are examined, and treatment with permanent pacing is evaluated.

Cardiac Pacing, Artificial↗

Diastolic coronary vascular reserve: a new index to detect changes in the coronary microcirculation in hypertrophic cardiomyopathy.

OBJECTIVES: The present study introduces a modification of the diastolic coronary conductance concept that maintains its sensitive properties to detect changes in the coronary microcirculation in human hypertrophy. BACKGROUND: Decrements of coronary flow in hypertrophy have been explained by changes in the coronary microcirculation. No measure is available to detect these changes. METHODS: Doppler velocity catheters were introduced into the left anterior descending artery (LAD) and left circumflex coronary artery (LCx) of patients with obstructive hypertrophic cardiomyopathy (HCM) (n = 11) and into the LAD of cardiac transplant recipients (n = 9). The diastolic coronary conductance was measured at rest and after maximal hyperemia induced by a bolus injection of adenosine. Diastolic coronary vasodilator reserve (DCVR) was calculated as the hyperemic diastolic coronary conductance, divided by the coronary conductance during resting conditions. RESULTS: Left ventricular outflow tract gradient in the HCM group (83 +/- 31 mm Hg) was significantly higher (p < 0.05). Septal wall thickness was significantly increased (p < 0.05), while wall thickness was unchanged in the posterior wall of the HCM group. The coronary flow reserve was significantly decreased in the HCM-LCx region (to 64 +/- 7% of control) and in the HCM-LAD regions (to 57 +/- 7% of control). The DCVR was only decreased in the HCM-LAD (to 46 +/- 3% of control) and not in the HCM-LCx group (86 +/- 6%, p > 0.05). Esmolol did affect the pressure gradient and systolic shortening, but did not affect the maximal diastolic conductance. CONCLUSIONS: The DCVR, in contrast with the coronary flow reserve, is decreased in those regions that display a disturbance in the microcirculation and may, therefore, offer a new way to study coronary adaptations in patients with hypertrophy.

Adenosine↗

Guiding and optimization of resynchronization therapy with dynamic three-dimensional echocardiography and segmental volume--time curves: a feasibility study.

OBJECTIVE: To assess a new approach for guiding and hemodynamic optimization of resynchronization therapy, using three-dimensional (3D) transthoracic echocardiography. BACKGROUND: Resynchronization therapy for heart failure provides the greatest hemodynamic benefit when applied to the most delayed left ventricular (LV) site. Currently, the ideal LV pacing site is selected according to acute invasive hemodynamic assessment and/or tissue Doppler imaging. METHODS: A total of 16 patients with advanced heart failure and an implanted biventricular pacemaker were included in this study. Transthoracic apical LV images at equidistant intervals were obtained using a prototype, fast-rotating second harmonic transducer to reconstruct 3D LV datasets during sinus rhythm (SR), right ventricular (RV) apical and biventricular pacing mode. A semi-automated contour analysis system (4D LV analysis, TomTec, Germany) was used for segmental wall motion analysis and identification of the most delayed contracting segment and calculation of global LV function. RESULTS: Data acquisition duration was 10 s and analyzable 3D images were obtained in 12 patients. Of these patients, data during SR were available in 9 and during biventricular pacing in 11. The greatest contraction delay during SR was found in the anterior and antero-septal segments in five of nine patients. Biventricular pacing resulted in reduction of the contraction delay in seven of eight patients. The global LV function did not change significantly. CONCLUSION: 3D echocardiography with appropriate analytic software allows detection of the most delayed LV contracting segment and can be used to select the optimal pacing site during resynchronization therapy.

Aged↗

Hypertrophic cardiomyopathy in a large community-based population: clinical outcome and identification of risk factors for sudden cardiac death and clinical deterioration.

OBJECTIVES: This study evaluates the clinical course and identifies risk factors for sudden cardiac death (SCD) and clinical deterioration in hypertrophic cardiomyopathy (HCM) in a large community-based population. Comparison was made with data from six tertiary referral and six nonreferral institutions. BACKGROUND: Hypertrophic cardiomyopathy is a disease with marked heterogeneity in clinical presentation and prognosis. Risk factors for SCD are not well defined in patients free of referral bias. METHODS: Between 1970 and 1999, 225 consecutive patients (mean age [+/-SD] 41+/-16 years) were examined and followed at yearly intervals. RESULTS: Forty-four deaths were recorded of which 27 cases were cardiovascular. Fourteen patients died suddenly, six were successfully resuscitated, and seven patients died of congestive heart failure. The annual mortality, annual cardiac mortality, and annual mortality due to sudden death were 1.3%, 0.8%, and 0.6%, respectively. At least one New York Heart Association (NYHA) functional class deterioration was reported in 33% of the patients with a significant (> or =50 mm Hg) left ventricular outflow tract (LVOT) gradient in contrast to 7% without obstruction. The presence of syncope was related to SCD (p < 0.05). Younger age and more severe functional limitation distinguishes patients from in hospital-based centers from the ones in community-based centers. CONCLUSIONS: Hypertrophic cardiomyopathy is a benign disease in an unselected population with a low incidence of cardiac death. Syncope was associated with a higher incidence of SCD and patients with a significant LVOT obstruction were more susceptible to clinical deterioration.

Adult↗

Visualization of myocardial perfusion after percutaneous myocardial septal ablation for hypertrophic cardiomyopathy using superharmonic imaging.

Harmonic imaging is used for detection of ultrasound contrast agents in myocardial perfusion studies. However, harmonic imaging has limitations because of the presence of tissue harmonics, which results in less specificity and sensitivity, thus, lower contrast-to-tissue ratio. We describe a clinical example using superharmonic imaging. This technique detects the third, fourth, and fifth harmonics. These harmonics are not created in tissue, resulting, hence, in a high contrast-to-tissue ratio. After myocardial alcohol ablation for hypertrophic cardiomyopathy areas of nontreated and treated myocardium, normal and low flow could be visualized with superharmonic imaging.

Cardiomyopathy, Hypertrophic↗

Contrast harmonic imaging.

The behavior of ultrasound contrast agents depends highly on the acoustic pressure of the insonified ultrasound wave. For low pressure the expansion and compression is linear to the pressure, for medium acoustic pressure nonlinear behavior starts to occur and for high pressures, but still in the diagnostic range transient scattering can be noticed, resulting in an enhanced scattering followed by a disappearance of the bubble. The nonlinear and transient regime can be utilized for imaging of the contrast agent in or nearby tissue. The magnitude of the nonlinear signal from the contrast has to compete with the nonlinear component of the ultrasound wave, which is generated during propagation. It is shown that contrast is superior to tissue when using low frequencies and imaging the third or fourth harmonic of the transmitted frequency.

Journal Article↗