Search PubMed⌕ Search

Biomedical subjects

Florian M Vogt

Publications and source records attributed to Florian M Vogt.

At least 19 recordsLinked to original sources

The predisposition to inspiratory upper airway collapse during partial neuromuscular blockade.

RATIONALE: Partial neuromuscular transmission failure by acetylcholine receptor blockade (neuromuscular blockade) or antibody-mediated functional loss (myasthenia gravis), even with a magnitude of muscle weakness that does not evoke respiratory symptoms, can evoke dysphagia and decreased inspiratory airflow, and increases the risk of susceptible patients to develop severe pulmonary complications. OBJECTIVES: To assess whether impaired neuromuscular transmission predisposes individuals to inspiratory upper airway collapse, we assessed supraglottic airway diameter and volume by respiratory-gated magnetic resonance imaging, upper airway dilator muscle function (genioglossus force and EMG), and changes in lung volume, respiratory timing, and peripheral muscle function before, during, and after partial neuromuscular blockade in healthy, awake volunteers. MEASUREMENTS AND MAIN RESULTS: Partial neuromuscular blockade (train-of-four [TOF] ratio: 0.5 and 0.8) was associated with the following: (1) a decrease of inspiratory retropalatal and retroglossal upper airway volume to 66 +/- 22 and 82 +/- 12% of baseline, which was significantly more intense in the retropalatal area; (2) an attenuation of the normal increase in anteroposterior upper airway diameter during forced inspiration to 74 +/- 18% of baseline; (3) a decrease in genioglossus activity during maximum voluntary tongue protrusion to 39 +/- 19% (TOF, 0.5) and 73 +/- 29% (TOF, 0.8) of baseline; and (4) no effects on upper airway size during expiration, lung volume, and respiratory timing. CONCLUSIONS: Thus, impaired neuromuscular transmission, even to a degree insufficient to evoke respiratory symptoms, markedly impairs upper airway dimensions and function. This may be explained by an impairment of the balance between upper airway dilating forces and negative intraluminal pressure generated during inspiration by respiratory "pump" muscles.

Adult↗

Time-resolved contrast-enhanced magnetic resonance angiography of the hand with parallel imaging and view sharing: initial experience.

We sought to compare a three-dimensional, contrast-enhanced, magnetic resonance angiogram (3D CE MRA) sequence combining parallel-imaging (generalised autocalibrating partially parallel acquisitions (GRAPPA)) with a time-resolved echo-shared angiographic technique (TREAT) in an intraindividual comparison to a standard 3D MRA sequence. Four healthy volunteers (27-32 years), and 11 patients (11-82 years) with vascular pathologies of the hand were examined on a 1.5-Tesla (T) MR system (Magnetom Avanto, Siemens, Erlangen, Germany) using two multichannel receiver coils. Following automatic injection (flow rate 2.5 cc/s) of 0.1 mmol/kg gadoterate (Dotarem, Guerbet, Roissy, France), 32 consecutive 3D data sets were collected with the TREAT sequence (TR/TE: 4.02/1.31 ms, FA: 10 degrees, GRAPPA acceleration factor: R=2, TREAT factor: 5, voxel size: 1.0 x 0.7 x 1.3 mm(3)) and a T1-wwighted 3D gradient-echo sequence (TR/TE: 5.3/1.57 ms, FA: 30 degrees, GRAPPA acceleration factor: 2, voxel size: 0.71 x 0.71 x 0.71 mm(3,)). MR data sets were evaluated and compared for image quality and visualisation of vascular details. In the volunteer group, all MR imaging was successful while technical problems prevented acquisition of the standard protocol in two patients. For the corresponding segments, the number of visible segments was equal on both sequences. Overall image quality was significantly better on the standard protocol than on the TREAT protocol. TREAT MRA provided functional information in lesions with rapid blood flow, e.g. detection of feeding and draining vessels in an haemangioma. TREAT-MRA is a robust technique that combines morphological and functional information of the hand vasculature and deals with the very special physiological demands of vascular lesions, such as quick arteriovenous transit time.

Adolescent↗

Magnetic resonance imaging of experimental atherosclerotic plaque: comparison of two ultrasmall superparamagnetic particles of iron oxide.

PURPOSE: To evaluate a new ultrasmall superparamagnetic particles of iron oxide (USPIO) compound, ferumoxytol, as a marker of macrophage activity in atherosclerotic plaques and to compare it to ferumoxtran-10. MATERIALS AND METHODS: Ten mature heritable hyperlipidemic (WHHL) female Watanabe rabbits served as the animal model for atherosclerosis, four coeval female New Zealand White (NZW) rabbits were the control group. Five WHHL and two NZW received a single intravenous injection (250 micromol/kg) of either ferumoxtran-10 or ferumoxytol and were subjected to daily MR examinations on a 1.5T whole body scanner for the next five days. Development of signal intensity changes and susceptibility effects was assessed. Statistical analysis was based on a nonparametric Wilcoxon-Mann-Whitney-U test by using a P value at the 0.05 significance level. On day 5, the rabbits were sacrificed and the aorta was referred to histopathology, distribution of iron particles in the vessel wall was analyzed. RESULTS: MRI was feasible in all animals. Three days after injection of ferumoxytol the highest luminal signal intensity measurements were observed in the ferumoxytol group; the highest measurements were five days after injection in the ferumoxtran-10 group (P < 0.05). In the WHHL, susceptibility effects presented as homogeneous dark lines parallel to the aortic wall after ferumoxytol and spotted areas void of signal after ferumoxtran-10. None of these findings were observed in the NZW control groups. CONCLUSION: Ferumoxtran-10 and ferumoxytol at a respective dose of 250 mumol/kg appear well suited for atherosclerotic plaque detection with MRI in experimental atherosclerosis. Ferumoxytol warrants further analysis in humans.

Animals↗

High-resolution continuously acquired peripheral MR angiography featuring partial parallel imaging GRAPPA.

Continuously-moving-table MRI, in contrast to traditional multistation techniques, potentially can improve the scan time efficiency of whole-body applications and provide seamless images of an extended field of view (FOV). Contrast-enhanced MR angiography (CE-MRA) in particular requires high spatial resolution and at the same time has rigid scan time constraints due to the limited arterial contrast window. In this study a reconstruction method for continuously acquired 3D data sets during table movement was combined with a self-calibrated partial parallel imaging algorithm (generalized autocalibrating partially parallel acquisitions (GRAPPA)). The method was applied to peripheral CE-MRA and compared with a standard continuously-moving-table MRA protocol. The gain in scan time was used to increase the data acquisition matrix and decrease the slice thickness. The method was evaluated in five healthy volunteers and applied to one patient with peripheral arterial occlusive disease (PAOD). The protocols were intraindividually compared with respect to the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in selected vessel segments, as well as overall vessel depiction. The combination of the continuously-moving-table technique with parallel imaging enabled the acquisition of seamless peripheral 3D MRA with increased resolution and an overall crisper appearance.

Algorithms↗

Evaluation of steady state free precession imaging of the pancreas.

The aim of this work was to assess the diagnostic value of fast steady state free precession (SSFP) for the detection, characterization, and delineation of pancreatic lesions. Forty-eight patients referred for magnetic resonance (MR) imaging of the pancreas were included in the study. In addition to the standard protocol, axial pre-contrast SSFP slices of the pancreas were acquired. The standard of reference was defined as based on all imaging data other than SSFP, histopathology, surgery, and/or clinical follow-up. A randomized consensus reading of the SSFP data sets was retrospectively conducted by two board-certified radiologists. The presence of pancreatic lesions, local infiltration, and lymph node metastases was evaluated. Sensitivity and specificity were calculated and a receiver operating characteristic (ROC) analysis was performed. The overall sensitivity and specificity of SSFP were 0.93 and 0.77, respectively. Comparable values were achieved for lymph node detection (0.88/0.91) and assessment of vascular infiltration (0.94/0.91). The mean area under the ROC curve (Az) was 0.91. Owing to its potential to detect vascular infiltration and the rapid acquisition time, SSFP imaging should be supplemented as part of a standard MR protocol of the pancreas.

Contrast Media↗

Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: assessment of image quality and lesion conspicuity.

PURPOSE: To evaluate the impact of parallel acquisition techniques (PATs) on image quality and detection of liver metastases using three-dimensional volumetric interpolated breath-hold examination (VIBE) for clinical liver imaging. MATERIALS AND METHODS: Forty-nine patients with various primary malignancies underwent abdominal dynamic contrast-enhanced three-dimensional VIBE magnetic resonance imaging (MRI) (1.5 T) using a standard phased array coil. Recently introduced Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) and SENSitivity Encoding (mSENSE) PAT reconstruction algorithms were added to reduce scan time twofold. Overall image quality, motion, and aliasing artifacts were classified on a 5-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements were performed for quantitative comparison. All sequences were evaluated concerning the number of detected lesions. RESULTS: PAT resulted in a reduction of data acquisition time from 23 to 13 seconds. Both GRAPPA and mSENSE data sets yielded 30% less SNR (34.8 +/- 14.1 and 33.1 +/- 13.3, P < 0.001) and 35% less CNR (21.2 +/- 15.0 and 20.9 +/- 12.7, P < 0.05) in comparison to unaccelerated VIBE (SNR = 50.8 +/- 20.3/CNR = 32.5 +/- 19.1). Similarly, PAT revealed lower-image-quality scores than unaccelerated VIBE. GRAPPA resulted in more fold-over artifacts than mSENSE. mSENSE revealed slightly fewer motion artifacts than no PAT. The unaccelerated late-venous-phase VIBE sequence revealed 146 lesions in the same patients. Accelerated images with mSENSE reconstruction detected 138 lesions. GRAPPA revealed 127 lesions, and thus performed inferior to mSENSE. CONCLUSION: At least for arrays with small numbers of elements, such as arrays used in this study, the PAT-induced reduction in scanning times must be weighed against compromises in image quality, which translate into poorer diagnostic performance regarding detection of small hepatic lesions. Thus, the PAT implementations tested in this study should probably be reserved for patients unable to hold their breaths for regular three-dimensional VIBE data sets.

Abdomen↗

Whole-body magnetic resonance imaging featuring moving table continuous data acquisition with high-precision position feedback.

A novel setup for whole-body MR imaging with moving table continuous data acquisition has been developed and evaluated. The setup features a manually positioned moving table platform with integrated phased-array surface radiofrequency coils. A high-precision laser position sensor was integrated into the system to provide real-time positional data that were used to compensate for nonlinear manual table translation. This setup enables continuous 2D and 3D whole-body data acquisition during table movement with surface coil image quality. The concept has been successfully evaluated with whole-body steady-state free precession (TrueFISP) anatomic imaging in five healthy volunteers. Seamless coronal and sagittal slices of continually acquired whole-body data during table movement were accurately reconstructed. The proposed strategy is potentially useful for a variety of applications, including whole-body metastasis screening, whole-body MR angiography, large field-of-view imaging in short bore systems, and for moving table applications during MR-guided interventions.

Algorithms↗

MR venography.

Explore the source record for details and available documents.

Blood Flow Velocity↗

Whole-body MRI for staging patients with head and neck squamous cell carcinoma.

CONCLUSIONS: Whole-body MRI is feasible for the tumor staging of patients with malignant head and neck tumors and appears to be a quick, reliable and proven alternative in general and for patients with contraindications to CT. This examination minimizes the logistical effort required compared to multimodality strategies. Its economic impact remains to be determined. OBJECTIVE: To assess the performance of whole-body MRI for staging patients with squamous cell carcinoma of the head and neck region. MATERIAL AND METHODS: This was a randomized, prospective clinical study. For tumor staging, 21 patients (mean age 56.7 years; range 43-80 years) with advanced malignant head and neck tumors underwent whole-body MRI in addition to routinely performed imaging investigations, including sonography, chest X-ray, CT of the head, neck and thorax and endoscopy. All investigations were accomplished within a period of 10+/-3 days in a random order. A randomized, blinded, consensus assessment of all the whole-body MRI examinations was performed by two radiologists. The localization and extent of the primary tumor and metastases were documented for whole-body MRI and compared to the standard of reference (all other imaging modalities as well as histology). Point estimates of the diagnostic accuracy of whole-body MRI were calculated. RESULTS: In accordance with the standard of reference, the overall TNM category was correctly determined with whole-body MRI in all 21 patients. However, four patients were classified as having carcinoma of unknown primary, as the primary tumor was not found with any imaging modality. Two patients had mediastinal, pulmonary and hepatic metastases.

Adult↗

Full-body cardiovascular and tumor MRI for early detection of disease: feasibility and initial experience in 298 subjects.

OBJECTIVE: High diagnostic accuracy, emerging whole-body concepts, and lack of side effects combine to render MRI a natural candidate for screening purposes. The aim of this study was to evaluate the technical feasibility of a comprehensive multiorgan-targeting MRI examination and determine the frequency of findings in subjects without a history of serious disease. SUBJECTS AND METHODS: The study group was composed of 331 subjects. The MRI protocol (mean examination time, 63 min) encompassed the target organs: the brain, arterial system, heart, and colon. Diagnoses were deemed relevant if the physician had to inform the subject about the findings. Subjects with a history of serious illnesses were excluded from subsequent analysis (n=33). All analyses were performed for the resulting subgroup of 298 subjects (247 men, 51 women; mean age, 49.7 years). RESULTS: All 298 examinations were diagnostic excluding eight MR colonography components in which remaining stool hampered reliable diagnosis. Follow-up or radiologic confirmation could be obtained in 75% of all cases with relevant findings (128/169); only one false-positive result was encountered. Of the study group, 21% exhibited signs of atherosclerotic disease. Two cerebral infarctions and one myocardial infarction, previously unknown, were encountered; 12% had peripheral vascular disease. Twelve colonic polyps and nine pulmonary lesions were correctly detected. Of all MRI examinations, 29% revealed relevant additional findings in nontargeted organs. Only one minor allergoid reaction was encountered. CONCLUSION: The presented data point toward an increased use of MRI for screening in the future, but to date screening MRI should not be performed outside a research setting because the cost-benefit relation is unclear.

Adult↗

Myocardial late enhancement in contrast-enhanced cardiac MRI: distinction between infarction scar and non-infarction-related disease.

OBJECTIVE: Our objective was to assess and compare the patterns of late enhancement (LE) in contrast-enhanced cardiac MRI caused by myocardial infarction and different myocardial diseases that are not related to ischemic infarction. MATERIALS AND METHODS: A total of 811 consecutive contrast-enhanced cardiac MRI studies performed for different indications were reviewed for left ventricular myocardial LE after gadopentetate dimeglumine administration. MRI studies were performed on a 1.5-T scanner using an inversion recovery turbo FLASH sequence (TR/TE, 8/4 msec; flip angle, 25 degrees). The LE pattern of ischemic infarction scar was compared with that in nonischemic myocardial disease. RESULTS: LE was found in 421 (52%) patients. In all patients with myocardial infarction, LE included the subendocardial layer. Nineteen patients without history of myocardial infarction and angiographically excluded coronary artery disease showed different patterns of LE caused by myocarditis, sarcoidosis, arrhythmogenic right ventricular dysplasia, cardiomyopathy, endomyocardial fibrosis, and iatrogenic scars after biopsy, ablation of septal hypertrophy, and myocardial laser revascularization. CONCLUSION: LE in contrast-enhanced cardiac MRI is not specific for ischemic infarction. LE in ischemic infarction always involves the subendocardial layer, whereas it does not necessarily do so in other myocardial diseases. Therefore, if LE omit the subendocardial layer, different nonischemic myocardial diseases have to be considered. The pattern of LE might be helpful for the differential diagnosis of myocardial disease and in distinguishing it from ischemic disease.

Adult↗

Assessment of liver tissue after radiofrequency ablation: findings with different imaging procedures.

UNLABELLED: Our goal was to assess the typical appearance of normal liver tissue immediately after radiofrequency ablation (RF-ablation) when imaged with contrast-enhanced ultrasound, CT, MRI, 18F-FDG PET, and PET/CT. METHODS: Nineteen RF-ablation sessions were performed on nontumorous liver tissue of 10 Göttingen Mini Pigs. CT, ultrasound, MRI, 18F-FDG PET, and PET/CT were performed immediately after the intervention. All imaging procedures were evaluated qualitatively for areas of increased contrast enhancement (morphologic imaging) and regions of elevated tracer uptake (functional imaging). Images were assessed quantitatively by determination of ratios (r(p/p)) comparing contrast enhancement/tracer uptake in the periphery of the necrosis with contrast enhancement/tracer uptake of normal liver parenchyma. RESULTS: On morphologic imaging, an increase in contrast enhancement surrounding the ablative necrosis was detected in all lesions. Quantification of this area of increased contrast enhancement revealed ratios of r(p/p) = 1.57 +/- 0.2 for CT and r(p/p) = 1.57 +/- 0.19 for MRI. On PET and PET/CT, homogeneous tracer utilization was found surrounding all lesions. There were no areas of a focal or rim-like increase in glucose metabolism. The ratio r(p/p) was found to be 1.05 +/- 0.08 for functional data. Histologic examination revealed pooling of blood in the sinusoids of the lesion's periphery that was caused by outflow obstruction due to the central necrosis. CONCLUSION: On morphologic imaging, a rim-like increase of contrast enhancement was found immediately after RF-ablation resembling peripheral hyperperfusion. This area of contrast enhancement may hamper detection of residual tumor. On the basis of homogeneous tracer distribution surrounding the area of necrosis, PET and PET/CT may serve for early assessment of patients after RF-ablation.

Animals↗

Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries.

The aim of this study was to assess a venous compression technique that is performed with contrast material-enhanced peripheral magnetic resonance (MR) angiography to reduce venous enhancement. Healthy volunteers, as well as patients with correlating digital subtraction angiographic (DSA) findings, were examined. Venous compression was accomplished by placing a cuff at the midfemoral level unilaterally. Arterial signal-to-noise and contrast-to-noise ratios indicated no significant differences between compressed and noncompressed legs. Venous overlay was substantially reduced in the compressed legs. MR angiography with venous compression yielded diagnostic image quality and results that had excellent correlation with DSA findings. High-spatial-resolution peripheral MR angiography of improved diagnostic quality appears feasible, even with long data acquisition times.

Adult↗

Increased time rate of change of gradient fields: effect on peripheral nerve stimulation at clinical MR imaging.

PURPOSE: To increase gradient stimulation from 100% to a fixed 120% level and to assess patient acceptance of the degree of peripheral nerve stimulation (PNS) at magnetic resonance (MR) imaging. MATERIALS AND METHODS: Two hundred ten patients underwent MR imaging of various body regions according to clinical indications. An additional three-dimensional fast low-angle shot sequence with the 120% stimulation level was performed. A patient questionnaire was distributed after MR imaging to document the presence, degree, and location of PNS. Degree was measured with an 11-point scale (score range, 0-10). Age was analyzed between the sexes for significant statistical differences. Furthermore, correlation between location of examination and location and degree of stimulation was performed. To determine stimulation discomfort relative to other factors typically present at MR imaging, the degree of discomfort due to room temperature, size of magnet bore, acoustic noise, examination time, and heating sensation was determined for comparison, as well. RESULTS: Thirty-five (16.7%) patients reported a stimulation sensation during imaging in one or more locations, while six (2.9%) felt very uncomfortable local stimulation (score of 8-10). No significant difference between male and female patients regarding age, sex, and appearance or degree of stimulation sensation could be detected. No significant correlation between location of examination and location and degree of stimulation was recorded. Compared with other side effects, PNS was considered relatively unimportant. CONCLUSION: The 120% gradient stimulation level seems acceptable for routine clinical imaging with this gradient system, since only 2.9% of patients experienced very uncomfortable local stimulation.

Adolescent↗

MR-based full-body preventative cardiovascular and tumor imaging: technique and preliminary experience.

Recent improvements in hardware and software, lack of side effects, as well as diagnostic accuracy make magnetic resonance imaging a natural candidate for preventative imaging. Thus, the purpose of the study was to evaluate the feasibility of a comprehensive 60-min MR-based screening examination in healthy volunteers and a limited number of patients with known target disease. In ten healthy volunteers (7 men, 3 women; mean age, 32.4 years) and five patients (4 men, 1 woman; mean age, 56.2 years) with proven target disease we evaluated the performance of a comprehensive MR screening strategy by combining well-established organ-based MR examination components encompassing the brain, the arterial system, the heart, the lungs, and the colon. All ten volunteers and five patients tolerated the comprehensive MR examination well. The mean in-room time was 63 min. In one volunteer, insufficient colonic cleansing on the part of the volunteer diminished the diagnostic reliability of MR colonography. All remaining components of the comprehensive MR examination were considered diagnostic in all volunteers and patients. In the five patients, the examination revealed the known pathologies [aneurysm of the anterior communicating artery ( n=1), renal artery stenosis ( n=1), myocardial infarct ( n=1), and colonic polyp ( n=2)]. The outlined MR screening strategy encompassing the brain, the arterial system, the heart, the lung, and the colon is feasible. Further studies have to show that MR-based screening programs are cost-effective in terms of the life-years saved.

Adult↗

HASTE MRI versus chest radiography in the detection of pulmonary nodules: comparison with MDCT.

OBJECTIVE: The purpose of our study was to compare the diagnostic accuracy of an ultrafast ECG-triggered black blood-prepared HASTE sequence with chest radiography for the detection of pulmonary nodules. SUBJECTS AND METHODS. Sixty-four patients with various primary malignancies who had undergone radiography and MDCT of the chest also underwent ECG-triggered black blood-prepared HASTE MRI of the lung. MR images and radiographs were interpreted separately. The number, location, and size of detected lesions were recorded, and each hemithorax was classified as affected or not affected on the basis of a grade reflecting the conspicuity of nodular involvement. Sensitivity, specificity, and positive and negative predictive values for the detection of pulmonary nodules with diameters of 5 mm or larger were determined, using MDCT findings as the standard of reference. Lesions with diameters smaller than 5 mm were not evaluated. Additional lesion-by-lesion comparisons between MDCT and MRI findings were performed. RESULTS: MDCT confirmed pulmonary lesions in 32 patients, whereas HASTE MRI revealed lesions in 30 patients and chest radiography, in 19 patients. MDCT revealed 226 nodules in 32 patients, whereas MRI HASTE revealed 227 lesions in 30 patients. Conspicuity scale-based sensitivity and specificity for chest radiography were 55.8% and 92.4%, respectively, whereas HASTE MRI had a sensitivity of 93.0% and a specificity of 96.2%. Positive and negative predictive values for chest radiography were 80% and 79.3%, respectively, and for HASTE MRI, 93.0% and 96.2%, respectively. The sensitivity of HASTE MRI increased with lesion size, ranging from 94.9% for nodules between 5 and 10 mm in diameter to 100% for lesions exceeding 3 cm in diameter. CONCLUSION: ECG-triggered black blood-prepared HASTE MRI is reliable for detecting pulmonary nodules exceeding 5 mm and has proven significantly more accurate than conventional chest radiography. The technique appears useful as an adjunct to MRI of the heart, great vessels, or chest, potentially increasing the diagnostic yield of MRI examinations.

Electrocardiography↗

Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology.

CONTEXT: Deciding on the appropriate therapy for patients with malignant diseases mandates accurate tumor staging with whole-body coverage. Magnetic resonance imaging (MRI) and a combined modality including positron emission tomography (PET) and computed tomography (CT) provide whole-body tumor staging in a single session. OBJECTIVE: To determine the staging accuracies of both whole-body PET/CT and whole-body MRI for different malignant diseases. DESIGN, SETTING, AND PATIENTS: Prospective, blinded, investigator-initiated study of 98 patients (mean age, 58 years; range, 27-94 years) with various oncological diseases who underwent back-to-back whole-body glucose analog [18F]-fluorodeoxyglucose-PET/CT and whole-body MRI for tumor staging. The study was conducted at a university hospital from December 2001 through October 2002 and had a mean follow-up of 273 days (range, 75-515 days). The images were evaluated by 2 different, blinded reader teams. The diagnostic accuracies of the 2 imaging procedures were compared. MAIN OUTCOME MEASURES: Correct classification of the primary tumor, regional lymph nodes, and distant metastasis (overall TNM stage) using whole-body PET/CT and whole-body MRI. Secondary outcome measures were accurate assessment of T-stage, N-stage, and M-stage by the 2 imaging procedures. RESULTS: Of 98 patients, the overall TNM stage was correctly determined in 75 with PET/CT (77%; 95% confidence interval [CI], 67%-85%) and in 53 with MRI (54%; 95% CI, 44%-64%) (P<.001). Compared with MRI, PET/CT had a direct impact on patient management in 12 patients. Results from MRI changed the therapy regimen in 2 patients compared with PET/CT. Separate assessment of T-stage (with pathological verification) in 46 patients revealed PET/CT to be accurate in 37 (80%; 95% CI, 66%-91%) and MRI to be accurate in 24 (52%; 95% CI, 37%-67%) (P<.001). Of 98 patients, N-stage was correctly determined in 91 patients with PET/CT (93%; 95% CI, 86%-97%) and in 77 patients with MRI (79%; 95% CI, 69%-86%) (P =.001). Both imaging procedures showed a similar performance in detecting distant metastases. CONCLUSIONS: The feasibility and diagnostic accuracy of the whole-body staging strategies of PET/CT and MRI are established. Superior performance in overall TNM staging suggests the use of [18F]-fluorodeoxyglucose-PET/CT as a possible first-line modality for whole-body tumor staging.

Adult↗

Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging.

The aim of this study was to compare the image quality of a saturation-recovery gradient-recalled echo (GRE; TurboFLASH) and a saturation-recovery SSFP (SR-TrueFISP) sequence for myocardial first-pass perfusion MRI. Eight patients with chronic myocardial infarction and 8 volunteers were examined with a TurboFLASH (TR 2.1 ms, TE 1 ms, FA 8 degrees ) and a SR-TrueFISP sequence (TR 2.1 ms, TE 0.9 ms, FA, 50 degrees ) on a 1.5 T scanner. During injection of 0.05 mmol/kg BW Gd-DTPA at 4 ml/s, three short axis slices (8 mm) of the left ventricle (LV) were simultaneously scanned during breath-hold. Maximum signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) between infarcted and normal myocardium, and percentage signal intensity change (PSIC) were measured within the LV lumen and in four regions of the LV myocardium for the three slices separately. For the LV lumen, SR-TrueFISP was superior in SNR and PSIC (factor 3.2 and 1.6, respectively). Mean maximum SNR, PSIC, and CNR during peak enhancement in the LV myocardium were higher for SR-TrueFISP compared with TurboFLASH (factor 2.4, 1.25, and 1.24, respectively). The SNR was higher in the septal portion of the ventricle than in anterior/posterior and lateral regions. The SR-TrueFISP provides higher SNR and improves image quality compared with TurboFLASH in first-pass myocardial perfusion MRI.

Adult↗