Single-beat noninvasive imaging of cardiac electrophysiology of ventricular pre-excitation.

OBJECTIVES: The aim of this study was to determine whether noninvasive imaging of cardiac electrophysiology (NICE) is feasible in patients with Wolff-Parkinson-White (WPW) syndrome in the clinical setting of a catheter laboratory and to test the accuracy of the noninvasively obtained ventricular activation sequences as compared with that of standard invasive electroanatomic mapping. BACKGROUND: NICE of ventricular activation could serve as a useful tool in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. METHODS: NICE works by fusing the data from high-resolution electrocardiographic mapping and a model of the patient's cardiac anatomy obtained by magnetic resonance imaging. The ventricular activation sequence was computed with a bidomain theory-based heart model to solve this inverse problem. Noninvasive imaging of cardiac electrophysiology was performed in 7 patients with WPW syndrome undergoing catheter ablation of the accessory pathway. The position error of NICE was defined as the distance between the site of earliest activation computed by NICE and the successful ablation site identified by electroanatomic mapping (CARTO; Biosense Webster, Diamond Bar, California) for normal atrioventricular (AV) conduction as well as for adenosine-induced AV block. RESULTS: The error introduced by geometric coupling of the CARTO data and the NICE model was 5 +/- 3 mm (model discretization 10 mm). All ventricular accessory pathway insertion sites were identified with an accuracy of 18.7 +/- 5.8 mm (baseline) and 18.7 +/- 6.4 mm (adenosine). CONCLUSIONS: The individual cardiac anatomy model obtained for each patient enables accurate noninvasive electrocardiographic imaging of ventricular pre-excitation in patients with WPW syndrome. Noninvasive imaging of cardiac electrophysiology might be used as a complementary noninvasive approach to localize the origin and help identify and understand the underlying mechanisms of cardiac arrhythmias.

Adult↗

Clinical predictors of health-related quality of life after pacemaker implantation.

BACKGROUND: Health-related quality of life (HRQL) is increasingly accepted as an outcome measure when considering the effectiveness of therapeutic interventions. Little is known about the HRQL of patients with different clinical circumstances before and after pacemaker implantation (PMI). The purpose of this study was to investigate the influence of clinical symptoms and ECG diagnoses as predictors of improved HRQL in patients referred for PMI. METHODS: Sixty eight patients with different indications for PMI completed the MacNew Heart Disease Health-related Quality of Life Questionnaire (MacNew) and the Short Form-36 Health Survey (SF-36) before and one, three and six months after PMI. Symptoms, ECG indications and pacing mode were collected using the European Pacemaker Patient Identification Card codes. RESULTS: Within the first month after PMI overall Mac-New but not SF-36 scores improved significantly and was maintained during the entire 6 month follow up period. Improvement in HRQL as measured with the MacNew was rather related to baseline symptoms and ECG diagnosis than to the pacing mode. CONCLUSION: The important finding of this study is that improved HRQL seen after PMI appears to be largely driven by baseline symptoms and the ECG diagnoses rather than the pacing mode of the device.

Aged↗

Transvenous pacemaker lead removal is safe and effective even in large vegetations: an analysis of 53 cases of pacemaker lead endocarditis.

BACKGROUND: The aim of this study was to investigate whether transvenous lead removal is safe and effective in patients with lead vegetations greater than 1 cm in size. METHODS: From 1991 to 2005, a total of 53 patients underwent pacemaker or ICD lead removal for vegetations. Transvenous lead removal using locking stylets and sheaths was performed in 30 patients (56.6%) and was found to be effective in 29 of those patients. In 1 patient, due to rupture of the lead, open heart removal of the ventricular lead remnant and tricuspid valve repair had to be performed due to persistent infection. In 23 of these patients, transesophageal echocardiography (TEE) verified vegetations greater than 1 cm in size. The remaining patients underwent primary lead removal using sternotomy and extracorporeal circulation (ECC). Pacemaker pocket infection was found in 16 patients (55.2%) of the transvenous study group and in 11 patients (45.8%) of the ECC group (P = 0.72). RESULTS: Perioperative mortality was 5.7% (3 patients); all of them underwent primary ECC removal and had severe endocarditis of the tricuspid valve. None of the patients who underwent transvenous lead removal died and there were no further complications such as pericardial tamponade or major pulmonary embolism requiring further interventions, even in patients demonstrating large vegetations. CONCLUSIONS: This study demonstrates that transvenous lead removal is a safe and highly effective procedure for the removal of infected pacemaker and ICD leads, even in patients with large vegetations. Embolism to the lung proceeds mainly without further complications; however, patients with vegetations that might obstruct a main stem of the pulmonary artery should undergo ECC removal.

Aged↗

Effects of cardiac resynchronization therapy on ventricular repolarization in patients with congestive heart failure.

INTRODUCTION: Biventricular pacing has been shown to improve the clinical status of patients with congestive heart failure, but little is known about its influence on ventricular repolarization. The aim of our study was to evaluate the effect of biventricular pacing on ECG markers of ventricular repolarization in patients with congestive heart failure. METHODS AND RESULTS: Twenty-five patients with congestive heart failure, sinus rhythm (SR), and complete LBBB (6 females; age 61 +/- 8 years; NYHA class II-III; echocardiographic ejection fraction 21 +/- 5%; QRS > or = 130 ms) underwent permanent biventricular DDDR pacemaker implantation. A high-resolution 65-lead body-surface ECG recording was performed at baseline and during right-, left-, and biventricular pacing, and the total 65-lead root mean square curve of the QRST complex and the interlead QT dispersion were assessed. The QRS duration was increased during right (RV)- and left ventricular (LV) pacing (127 +/- 26% and 117 +/- 40%; P < 0.05), as compared to SR (100%) and biventricular pacing (93 +/- 16%; ns). The QTc interval was increased during RV and LV pacing (112 +/- 12% and 114 +/- 14%; P < 0.05) as compared to SR (100%) or biventricular pacing (99 +/- 12%). There was no effect on JT interval during all pacing modes. The T(peak-end) interval was increased during right (120 +/- 34%; P < 0.01) and LV pacing (113 +/- 29%; P < 0.05) but decreased during biventricular pacing (81 +/- 19%; P < 0.01). A similar effect was found for the T(peak-end) integral and the T(peak) amplitude. QT dispersion was increased during right ventricular (129 +/- 16 ms; P < 0.05) and decreased during biventricular pacing (90 +/- 12 ms; P < 0.01), as compared to SR (114 +/- 22 ms). CONCLUSIONS: Using a high-resolution surface ECG, biventricular pacing resulted in a significant reduction of ECG markers of ventricular dispersion of repolarization.

Aged↗

A new endocardial "over-the-wire" or stylet-driven left ventricular lead: first clinical experience.

Transvenous left ventricular (LV) leads are primarily inserted "over-the-wire" (OTW). However, a stylet-driven (SD) approach may be a helpful alternative. A new polyurethane-coated, unipolar LV lead can be placed either by a stylet or a guide wire, which can be inserted into the lead body from both ends. The multicenter OVID study evaluates the clinical performance of this new steroid- and nonsteroid eluting lead. The primary endpoint is the LV lead implant success rate after identification of the coronary sinus (CS). Secondary endpoints include complication rate, short- and long-term lead characteristics, overall procedure and LV lead placement duration, total fluoroscopy time, and lead handling characteristics ratings. To date, 96 patients with heart failure (68 +/- 9 years old, 76% men) are enrolled. The CS was identified in 95 patients and, in 85 (88.5%), the LV lead was successfully implanted. The final lead positioning was lateral in 41%, posterolateral in 35%, anterolateral in 18%, and great cardiac vein in 6% of patients. In 70%, the 85 successful implantations, both stylet-driven and guide-wire techniques were used, a stylet only was used in 22%, and a guide wire only in 8%. Mean overall duration of 85 successful procedures was 112 +/- 40 minutes, total fluoroscopy time 28 +/- 15 minutes, and the duration of LV lead placement was 35 +/- 29 minutes. During a 3-month follow-up, the loss of LV capture occurred in three and phrenic nerve stimulation in six patients. The mean long-term pacing threshold is 0.8 V/0.5 ms and pacing impedance is 550 Omega. The OVID data suggest that these new leads are safe and effective. The choice of both OTW and SD techniques during lead implantation offers greater procedural flexibility.

Adult↗

Understanding capture detection.

Automatic capture detection systems are currently available in several cardiac pacing devices. All current systems use low-polarization electrodes and no beat to beat detection system is available for all types of electrodes. In addition the success ratio for currently available systems is not always 100%. Failure to detect capture reliably is often related to the behaviour of the electrode-tissue interface under different circumstances. Pacemaker electrodes can be considered electrochemical cells with complicated characteristics depending on time, temperature and electrical charge. This electrochemical cell is disturbed when a charge is transferred across the electrode-tissue interface during pacing. Several measures can be taken in order to minimise this disturbance or pace polarization artefact (PPA) including the use of high active surface area electrodes and application of tri-phasic pacing pulses. Another factor influencing detection of evoked potentials is the input circuit of the pacemaker affecting the PPA and the evoked response. Positive PPAs can be falsely interpreted as evoked potentials due to the undershoot of the second order filters applied in modern cardiac pacemakers. This paper explains the behaviour of the interface between the electrode and the cardiac tissue in combination with the pacemaker output circuits and input amplifiers under different circumstances.

Cardiac Pacing, Artificial↗

Evaluation of atrial conduction time at various sites of right atrial pacing and influence on atrioventricular delay optimization by surface electrocardiography.

Cardiac function and electrical stability may be improved by programming of optimal AV delay in DDD pacing. This study tested the hypothesis if the global atrial conduction time at various pacing sites can be derived from the surface ECG to achieve an optimal electromechanical timing of the left heart. Data were obtained from 60 patients following dual chamber pacemaker implantation. Right atrial septal pacing was associated with significantly shorter atrial conduction time (P < 0.0005) and P wave duration (P < 0.005), compared to standard right atrial pacing sites at the right atrial appendage or at the right free wall. The last two pacing sites showed no significant difference. In a group of 31 patients with AV block, optimal AV delay was achieved by programming a delay of 100 ms from the end of the paced P wave to peak/nadir of the paced ventricular complex. Optimization of AV delay resulted in a relative increase of echocardiographic stroke volume (SV) (10.9 +/- 13.7%; 95% CI: 5.9-15.9%) when compared to nominal AV delay (170 ms). Optimized AV delay was highly variable (range 130-250 ms; mean 180 +/- 35 ms). The hemodynamic response was characterized by a weak significant relationship between SV increase and optimized AV delay (R2 = 0.196, R = 0.443, P = 0.047). The study validated that septal pacing is advantageous for atrial synchronization compared to conventional right atrial pacing. Tailoring the AV delay with respect to the surface ECG improved systolic function significantly and was superior to nominal AV delay settings in the majority of patients.

Aged↗

Comparison of the specificity of implantable dual chamber defibrillator detection algorithms.

The aim of the study was to compare the specificity of dual chamber ICDs detection algorithms for correct classification of supraventricular tachyarrhythmias derived from clinical studies according to their size to detect an impact of sample size on the specificity. Furthermore, the study sought to compare the specificities of detection algorithms calculated from clinical data with the specificity calculated from simulations of tachyarrhythmias. A survey was conducted of all available sources providing data regarding the specificity of five dual chamber ICDs. The specificity was correlated with the number of patients included, number of episodes, and number of supraventricular tachyarrhythmias recorded. The simulation was performed using tachyarrhythmias recorded in the electrophysiology laboratory. The range of the number of patients included into the studies was 78-1,029, the range of the total number of episodes recorded was 362-5,788, and the range of the number of supraventricular tachyarrhythmias used for calculation of the specificity for correct detection of these arrhythmias was 100 (Biotronik) to 1662 (Medtronic). The specificity for correct detection of supraventricular tachyarrhythmias was 90% (Biotronik), 89% (ELA Medical), 89% (Guidant), 68% (Medtronic), and 76% (St. Jude Medical). There was an inverse correlation (r = -0.9, P = 0.037) between the specificity for correct classification of supraventricular tachyarrhythmias and the number of patients. The specificity for correct detection of supraventricular tachyarrhythmias calculated from the simulation after correction for the clinical prevalence of the simulated tachyarrhythmias was 95% (Biotronik), 99% (ELA Medical), 94% (Guidant), 93% (Medtronic), and 92% (St. Jude Medical). In conclusion, the specificity of ICD detection algorithms calculated from clinical studies or registries may depend on the number of patients studied. Therefore, a direct comparison between different detection algorithms based on clinical data is difficult. In contrast, simulation of supraventricular tachyarrhythmias using a uniform database may be a better tool for direct comparison of the specificity of ICD detection algorithms.

Arrhythmias, Cardiac↗

The influence of high versus normal impedance ventricular leads on pacemaker generator longevity.

As pacemaker generator longevity is dependent on current consumption and resistance of the pacing lead, the use of a high impedance pacing lead theoretically results in an extension of battery longevity. Therefore, the effect of high versus standard impedance ventricular leads on generator longevity was studied. In 40 patients (21 women, age 73 +/- 13 years) with a standard dual chamber pacemaker indication, a bipolar standard impedance ventricular lead was implanted in 20 patients, the remaining patients received a bipolar high impedance lead in a randomized fashion. All patients received identical pacemaker generators and atrial leads. The estimated longevity of the generator was calculated automatically by a programmed pacemaker algorithm. After a mean follow-up of 39 +/- 4.8 months, no significant differences were observed with respect to mean pacing and sensing thresholds of the atrial and ventricular leads in both groups. However, the high impedance leads displayed a significantly higher impedance and a significantly lower current drain as compared to standard impedance leads (1,044 +/- 139 vs 585 +/- 90 Omega, and 2.2 +/- 0.4 vs 4.3 +/- 1.1 mA). The extrapolated generator longevity was significantly longer in the high impedance lead group, as compared to the standard impedance lead group (107.3 +/- 8.5 vs 97.6 +/- 9.0 months; P = 0.02). In conclusion, implantation of a high impedance lead for ventricular pacing results in a clinically relevant extension of generator longevity.

Aged↗

Atrial noninvasive activation mapping of paced rhythm data.

INTRODUCTION: Atrial arrhythmias have emerged as a topic of great interest for clinical electrophysiologists. Noninvasive imaging of electrical function in humans may be useful for computer-aided diagnosis and treatment of cardiac arrhythmias, which can be accomplished by the fusion of data from ECG mapping and magnetic resonance imaging (MRI). METHODS AND RESULTS: In this study, a bidomain-theory-based surface heart model activation time (AT) imaging approach was applied to paced rhythm data from four patients. Pacing sites were the right superior pulmonary vein, left inferior pulmonary vein, left superior pulmonary vein, coronary sinus, posterior wall of right atrium, and high right atrium. For coronary sinus pacing, the AT pattern of the right atrium was compared with a CARTO map. The root mean square error between CARTO geometry (85 nodal points) and the surface model of the right atrium was 8.6 mm. The correlation coefficient of the noninvasively obtained AT map of the right atrium and the CARTO map was 0.76. All pulmonary vein pacing sites were identified. The reconstructed pacing site of right posterior atrial pacing correlates with the invasively determined pacing catheter position with a localization distance of 4 mm. CONCLUSION: The individual anatomic model of the atria of each patient enables accurate noninvasive AT imaging within the atria, resulting in a localization error for the pacing sites within 10 mm. Our findings may have implications for imaging of atrial activity in patients with focal arrhythmias or focal triggers.

Adult↗

Global P wave duration on the 65-lead ECG: single-site and dual-site pacing in the structurally normal human atrium.

INTRODUCTION: Pacing is believed to prevent atrial fibrillation by reducing atrial activation time. Exact correlation between P wave duration (PWD) on surface ECG and endocardial atrial activation time is still unexplored. METHODS AND RESULTS: In 15 patients without structural heart disease (9 women, age 45 +/- 14 years), single site [high right atrium (HRA), coronary sinus ostium (CSos), distal CS (CSd), high RA septum (Bachmann's bundle, BB)] and dual-site pacing (various combinations) was performed after ablation of supraventricular tachycardia. A 65-lead surface ECG was recorded simultaneously. Endocardial atrial activation time was measured off-line (stimulus - last bipolar recording), and the respective PWD was assessed using the root mean square and 65-channel summary plots. PWD during pacing from BB was significantly shorter (96 +/- 12 msec) than during HRA (121 +/- 15 msec), CSos (108 +/- 9 msec), and CSd pacing (126 +/- 14 msec; P < 0,01, respectively). PWD during dual-site pacing (HRA+BB, 91 +/- 14 msec; HRA+CSos, 96 +/- 7 msec; HRA+CSd, 90 +/- 7 msec; BB+CSd, 96 +/- 12 msec) was not significantly shorter than during pacing from BB. Correlation between endocardial atrial activation time and PWD was 0.83. CONCLUSION: PWD during single-site and dual-site atrial pacing represents endocardial atrial activation time and can be measured precisely using the 65-lead surface ECG. The fact that high septal pacing results in the shortest PWD may have implications for preventive pacing in patients with atrial fibrillation.

Adult↗

Clinical ECG mapping and imaging of cardiac electrical excitation.

Combining electrocardiographic mapping and 3D+time anatomical data enables noninvasively the imaging of the electrical excitation sequence in the human heart. A bidomain-theory based surface heart model activation time imaging approach was employed to image single beat data of atrial and ventricular depolarisation. Activation time maps were reconstructed for three patients who underwent an electrophysiologic study. The sinus rhythm and a rhythm according to a pacing protocol were reconstructed for two patients. For the third patient the accessory pathway of the WPW syndrome was localized. For focal arrhythmias, this model-based imaging approach might allow the guidance and evaluation of antiarrhythmic interventions, for instance, in case of catheter ablation or drug therapy.

Adult↗

Model-based imaging of cardiac electrical excitation in humans.

Activation time (AT) imaging from electrocardiographic (ECG) mapping data has been developing for several years. By coupling ECG mapping and three-dimensional (3-D) + time anatomical data, the electrical excitation sequence can be imaged completely noninvasively in the human heart. In this paper, a bidomain theory-based surface heart model AT imaging approach was applied to single-beat data of atrial and ventricular depolarization in two patients with structurally normal hearts. In both patients, the AT map was reconstructed from sinus and paced rhythm data. Pacing sites were the apex of the right ventricle and the coronary sinus (CS) ostium. For CS pacing, the reconstructed AT pattern on the endocardium of the right atrium was compared with the CARTO map in both patients. The localization errors of the origins of the initial endocardial breakthroughs were determined to be 6 and 12 mm. The sites of early activation and the areas with late activation were estimated with sufficient accuracy. The reconstructed sinus rhythm sequence was in good qualitative agreement with the pattern previously published for the isolated Langendorff-perfused human heart.

Adult↗