Impact of automatic adjustment of stimulation outputs on pacemaker longevity in a new dual-chamber pacing system.

INTRODUCTION: Automatic capture verification using the Autocapture (AC) feature enabled by paced evoked response detection and delivery of high energy back-up pulses intends to increase patient safety. Furthermore, adjustment of stimulation outputs can save energy and potentially improve pacemaker (PM) longevity. The purpose of this study was to evaluate the theoretical longevity of a new dual chamber PM with the integrated AC feature (Affinity DR, St. Jude Medical) in comparison to the longevity of a previous model from the same manufacturer without AC (Trilogy DR). METHOD: Affinity PMs were implanted in 16 patients and connected to a compatible lead with low polarization properties. AC was activated when the evoked response was significantly higher than the polarization voltage. Theoretical PM longevity was calculated with and without AC during follow-up. The measured and calculated values were compared to measurements in 19 patients, who consecutively received Trilogy-PMs during the same time period. RESULTS: In only one patient the evoked response was not adequate, and as a result, AC was not programmed. The calculated longevity of the Affinity-PMs 79 +/- 28 days after implantation was significantly higher in comparison to the Trilogy-PMs (Affinity-PMs: 8.9 +/- 1.2 years without and 9.5 +/- 1.1 years with AC; Trilogy-PMs: 6.5 +/- 0.8 years) (p < 0.005). CONCLUSION: The AC feature is an optional algorithm that can be activated in most patients and it significantly prolongs predicted battery longevity due to automatic adjustment of stimulation outputs.

Adult↗

Induction ovens and electromagnetic interference: what is the risk for patients with implanted pacemakers?

Electromagnetic fields may interfere with normal pacemaker function. Despite the introduction of modern pacemakers and bipolar lead systems, electromagnetic interference (EMI) still remains to be a concern during daily lives when patients are exposed to cellular phones, electronic security systems, and several household appliances. The aim of this study was to evaluate potential EMI risk of induction ovens, which are increasingly used in private households. The study included 40 consecutive patients (22 men, 18 women; age 73 +/- 11 years) with implanted DDD, VVI, VDD, and AAI pacemaker systems. The pacemakers were programmed to unipolar sensing and pacing. Sensitivity remained unchanged, if the measured sensing threshold was more than twice the programmed value; otherwise, it was set at half of the measured sensing threshold. Patients were placed in a sitting position at the closest possible distance of about 20 cm between two cooking pots and pacemaker bending the upper part of the body slightly over the induction oven. The energy was increased stepwise to the maximum. One pot was removed and placed again at the highest oven level. Potential interference was monitored continuously. The study showed no incidence of pacemaker malfunction during the entire test while the patients with intrinsic cardiac rhythms were exposed to the induction oven at varying energy strengths. Likewise, there was no external interference when the patients were paced at heart rates of 10-15 beats/min above their heart rates. The programmed parameters remained unchanged after the study. In conclusion, this study shows no EMI risk of an induction oven in patients with bipolar or right-sided unipolar pacemakers.

Aged↗

Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields?

MRI is established as an important diagnostic tool in medicine. However, the presence of a cardiac pacemaker is usually regarded as a contraindication for MRI due to safety reasons. The aim of this study was to investigate the state of a pacemaker reed switch in different orientations and positions in the main magnetic field of 0.5-, 1.5-, and 3.0-T MRI scanners. Reed switches used in current pacemakers and ICDs were tested in 0.5-, 1.5-, and 3.0-T MRI scanners. The closure of isolated reed switches was evaluated for different orientations and positions relative to the main magnetic field. The field strengths to close and open the reed switch and the orientation dependency of the closed state inside the main magnetic field were investigated. The measurements were repeated using two intact pacemakers to evaluate the potential influence of the other magnetic components, like the battery. If the reed switches were oriented parallel to the magnetic fields, they closed at 1.0 +/- 0.2 mT and opened at 0.7 +/- 0.2 mT. Two different reed switch behaviors were observed at different magnetic field strengths. In low magnetic fields (< 50 mT), the reed switches were closed. However, in high magnetic fields (> 200 mT), the reed switches opened in 50% of all tested orientations. No difference between the three scanners could be demonstrated. The reed switches showed the same behavior whether they were isolated or an integral part of the pacemakers. The reed switch in a pacemaker or an ICD does not necessarily remain closed in strong magnetic fields at 0.5, 1.5, or 3.0 T and the state of the reed switch may not be predictable with certainty in clinical situations.

Defibrillators, Implantable↗

Impact of fusion avoidance on performance of the automatic threshold tracking feature in dual chamber pacemakers: a multicenter prospective randomized study.

The Autocapture algorithm enables automatic capture verification on a beat-by-beat basis by recognizing the evoked response signal following each pacemaker stimulus. The algorithm intends to increase patient safety while decreasing energy consumption. However, the occurrence of fusion beats, particularly during dual chamber pacing, may limit the energy saving effect of Autocapture. The aim of this multicenter, prospective, randomized study was to evaluate the impact of the Fusion Avoidance (FA) algorithm on the incidence of fusion beats. Thirty-eight patients (mean age 69 +/- 13 years) with intrinsic AV conduction who were implanted with an Affinity DR were studied. After programming a PV/AV delay of 120/190 ms, patients were randomized to FA On or Off. Each group was further randomized with respect to activation of the AutoIntrinsic Conduction Search (AICS) algorithm. The total number of beats, ventricular paced beats, fusion beats, backup pulses, and threshold searches were analyzed from 24-hour Holter recordings. The number of total beats was comparable in both FA groups. The number of total ventricular paced beats, fusion beats, backup pulses, and threshold searches were significantly reduced in the FA On group (% reduction: 68% P < 0.001, 75% P < 0.01, 95% P < 0.01, and 94% P < 0.05, respectively). The number of ventricular paced beats with full capture was significantly reduced when AICS was activated (P < 0.05). In conclusion, the FA algorithm substantially reduces the amount of ventricular paced beats, fusion beats, unnecessary backup pulses and threshold searches, and therefore, provides added benefits in energy saving obtained by Autocapture.

Aged↗

Rate responsive pacing using transthoracic impedance minute ventilation sensors: a multicenter study on calibration stability.

Previous studies showed that transthoracic impedance minute ventilation (IMV), as measured by a pacemaker sensor, is closely correlated to actual minute ventilation (VE) determined by standard methods. The aim of this study was to analyze the changes in the calibration between IMV and VE at rest and during exercise over time. Fifteen patients (age 60 +/- 13 years) with Medtronic Kappa 400 pacemakers completed a baseline visit followed by two visits separated by 1 month and 1 week, respectively. In each patient, VE (L/min) was monitored at rest in the supine and sitting positions and during graded bicycle ergometer exercise using a standard cardiopulmonary metabolic gas analysis system with simultaneous recording of IMV (omega/min) using DR-180 extended telemetry monitors. Calibration at rest was defined as the ratio of IMV to VE, calculated from 1-minute average values in the supine and sitting positions. Calibration during bicycle exercise was defined as intercept (IMV value at VE = 10 L/min-typical VE value at beginning of exercise), and slope of the IMV/VE regression line. The calibration of IMV showed individual variability over time. The magnitude (absolute value) of observed fractional changes in calibration at 1 month was 0.23 +/- 0.20 (rest-supine), 0.20 +/- 0.15 (rest-sitting), 0.18 +/- 0.19 (exercise-intercept), 0.28 +/- 0.35 (exercise-slope), and 0.18 +/- 0.15, 0.15 +/- 0.09, 0.28 +/- 0.39, and 0.27 +/- 0.15, respectively, at 1 week. The magnitude of change at 1 month was not statistically different from the magnitude of change at 1 week. In conclusion, the calibration of IMV, as measured by a pacemaker sensor, versus actual VE may demonstrate variability. However, this study also suggests that the observed changes are not cumulative over time. These results have implications for patient monitoring applications using these sensors and for development of future pacemaker rate response algorithms.

Arrhythmias, Cardiac↗

CARTO three-dimensional non-fluoroscopic electroanatomic mapping for catheter ablation of arrhythmias: a useful tool or an expensive toy for the electrophysiologist?

This review enlightens the application issues of the novel CARTO electroanatomic mapping system (Biosense Webster, Diamond Bar, CA, USA) in both research and clinical electrophysiology. It is a very useful tool in catheter ablation procedures in patients with sustained atrial tachycardias, macroreentrant atrial arrhythmias after surgical correction of congenital heart disease, and ventricular tachycardia in the setting of previous myocardial infarction or other structural heart disease. It can also be useful in other types of arrhythmias, including isthmus dependent atrial flutter and idiopathic ventricular tachycardia, by guiding the ablation procedure and limiting fluoroscopy. The major drawbacks for more widespread use of electroanatomic mapping at present time include the inability to map nonsustained arrhythmias and the associated high costs of the mapping system.

Atrial Flutter↗