Search PubMed⌕ Search

Biomedical subjects

Filippo Cademartiri

Publications and source records attributed to Filippo Cademartiri.

At least 37 records · Page 2Linked to original sources

Effects of primary angioplasty for acute myocardial infarction on early and late infarct size and left ventricular wall characteristics.

UNLABELLED: The effects of reperfusion on early and late infarct size and left ventricular wall characteristics were studied by performing cine-magnetic resonance imaging, first-pass perfusion, and delayed enhancement imaging in 22 patients at five days and five months after successful primary angioplasty for first acute myocardial infarction. Infarct size, end-diastolic wall thickness, and segmental wall thickening were quantified, and the extent of microvascular obstruction (MO) was evaluated qualitatively. Infarct size decreased by 31%. Segments without MO had early increased wall thickness and late partially normalized wall thickening. Segments with MO showed late wall thinning and no functional recovery at five months. OBJECTIVES: We aimed to study the effects of early successful primary angioplasty for ST-segment elevation acute myocardial infarction (AMI) on early and late infarct size and left ventricular (LV) wall characteristics. BACKGROUND: Early reperfusion treatment for AMI preserves LV function, but the effects on early and late infarct size, end-diastolic wall thickness (EDWT), and segmental wall thickening (SWT) are not well known. METHODS: In 22 patients with successful primary angioplasty for first AMI, cine-magnetic resonance imaging (MRI), first-pass perfusion, and delayed-enhancement imaging was performed at five days and five months. The extent of microvascular obstruction (MO) was evaluated on perfusion images. Infarct shrinkage was defined as the difference between the volume of delayed-enhancement at five days and five months. The EDWT and SWT were quantified on cine-MRI. RESULTS: Infarct shrinkage occurred to the same extent in small and large infarctions [r = 0.92; p < 0.001], with a mean decrease of 31% (35 +/- 21 g to 24 +/- 17 g). Dysfunctional segments without MO had an increased EDWT at five days compared with remote myocardium (9.2 +/- 1.7 mm vs. 8.4 +/- 1.7 mm; p < 0.001). At five months, EDWT in these segments became comparable to the thickness of remote myocardium (7.8 +/- 1.6 mm vs. 7.6 +/- 1.4 mm; p = 0.60), and SWT improved (21 +/- 15% to 40 +/- 24%; p < 0.001) but remained impaired (40 +/- 24% vs. 71 +/- 29%; p < 0.001). Segments with MO demonstrated wall thinning at five months (6.4 +/- 1.3 mm vs. 7.6 +/- 1.4 mm; p = 0.006) and no significant recovery in SWT (12 +/- 14% to 17 +/- 20%; p = 0.15). CONCLUSIONS: Infarct size decreased by 31%. Segments without MO had early increased wall thickness and late partial functional recovery. Segments with MO showed late wall thinning and no functional recovery at five months.

Angioplasty, Balloon, Coronary↗

Chronic pseudoaneurysm of the left ventricle.

We present a case of a 55-year-old men who suffered a silent myocardial infarction four years earlier and presented with exertional dyspnoea. Cardiac magnetic resonance imaging (CMR) and Multislice computed tomography (MSCT) was performed and revealed a giant pseudoaneursym of the lateral wall of the left ventricle with the presence of a thrombus in the lateral wall of the pseudoaneursym. We present this case since excellent non-invasive evaluation of the pseudoaneursym was feasible using state-of-the-art imaging modalities. Information on left ventricular geometry and function as well as myocardial viability and coronary anatomy is available when both MSCT and CMR are performed. This combined approach of these two imaging modalities provide clinically relevant information and may guide therapeutic decision making.

Aneurysm, False↗

Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris.

Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as > or = 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures.

Aged↗

High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography.

BACKGROUND: The diagnostic performance of the latest 64-slice CT scanner, with increased temporal (165 ms) and spatial (0.4 mm3) resolution, to detect significant stenoses in the clinically relevant coronary tree is unknown. METHODS AND RESULTS: We studied 52 patients (34 men; mean age, 59.6+/-12.1 years) with atypical chest pain, stable or unstable angina pectoris, or non-ST-segment elevation myocardial infarction scheduled for diagnostic conventional coronary angiography. All patients had stable sinus rhythm. Patients with initial heart rates > or =70 bpm received beta-blockers. Mean scan time was 13.3+/-0.9 seconds. The CT scans were analyzed by 2 observers unaware of the results of invasive coronary angiography, which was used as the standard of reference. All available coronary segments, regardless of size, were included in the evaluation. Lesions with > or =50 luminal narrowing were considered significant stenoses. Invasive coronary angiography demonstrated the absence of significant disease in 25% (13 of 52), single-vessel disease in 31% (16 of 52), and multivessel disease in 45% (23 of 52) of patients. One unsuccessful CT scan was classified as inconclusive. Ninety-four significant stenoses were present in the remaining 51 patients. Sensitivity, specificity, and positive and negative predictive values of CT for detecting significant stenoses on a segment-by-segment analysis were 99% (93 of 94; 95% CI, 94 to 99), 95% (601 of 631; 95% CI, 93 to 96), 76% (93 of 123; 95% CI, 67 to 89), and 99% (601 of 602; 95% CI, 99 to 100), respectively. CONCLUSIONS: Noninvasive 64-slice CT coronary angiography accurately detects coronary stenoses in patients in sinus rhythm and presenting with atypical chest pain, stable or unstable angina, or non-ST-segment elevation myocardial infarction.

Aged↗

Sixteen-detector row CT angiography of carotid arteries: comparison of different volumes of contrast material with and without a bolus chaser.

PURPOSE: To prospectively compare different volumes of intravenously administered contrast material with and without a bolus chaser at 16-detector row computed tomographic (CT) angiography of the carotid arteries. MATERIALS AND METHODS: Institutional Review Board approval and informed consent were obtained. Seventy-five consecutive patients (44 men, 31 women; mean age, 63 years; range, 22-85 years) were allocated to one of three protocols: group 1, 80 mL of contrast material; group 2, 80 mL of contrast material followed by 40 mL of saline; and group 3, 60 mL of contrast material followed by 40 mL of saline. Bolus tracking was used to synchronize contrast material injection with CT scanning. The attenuation in Hounsfield units was measured from the ascending aorta to the intracranial arteries at 1-second intervals. Differences were tested with the Student t test. RESULTS: The maximum attenuation was reached in the proximal internal carotid artery in all groups. The addition of a bolus chaser to 80-mL contrast material resulted in a higher mean attenuation (323 HU +/- 39 vs 351 HU +/- 60, P = .06), higher maximum attenuation (393 HU +/- 53 vs 425 HU +/- 76, P = .09), and higher minimum attenuation (240 HU +/- 34 vs 264 HU +/- 48, P < .05). Group 3 had lower mean, maximum, and minimum attenuation than did groups 1 and 2 (P < .001). CONCLUSION: The addition of a bolus chaser to 80 mL of contrast material results in a slightly higher attenuation. Decreasing the volume of contrast material from 80 to 60 mL results in a significantly lower attenuation.

Adult↗

Usefulness of multislice computed tomographic coronary angiography to assess in-stent restenosis.

Fifty-one patients (42 men; 60 +/- 12 years of age) who had previous stent implantation underwent multislice computed tomographic coronary angiography. All coronary branches > or = 2.0 mm were independently evaluated by 2 observers and screened for in-stent restenosis (> or = 50%) and occlusion. The consensus reading was compared with the quantitative coronary angiogram. Six of the 74 (8.1%) evaluated stents (3 restenoses and 3 occlusions) were significantly diseased. The sensitivity, specificity, and positive and negative predictive values to identify restenosis were 83.3% (95% confidence interval [CI] 35.9 to 99.6), 98.5% (95% CI 92.1 to 100), 83.3% (95% CI 35.9 to 99.6), and 97.3% (95% CI 92.1 to 100), respectively. One in-stent restenosis remained undetected.

Aged↗

Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates.

PURPOSE: Assess the effect of heart rate on diagnostic accuracy for the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). MATERIAL AND METHODS: About 120 patients (105 males; 59+/-11 years) with suspected coronary artery disease who underwent conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA (Sensation 16, Siemens, Germany), with the following protocol: collimation 16 x 0.75 mm, gantry rotation time 420 ms, feed/rotation 3.0 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol (Visipaque 320 mg l/ml, Amersham, UK) at 4 ml/s and the delay was defined with a bolus tracking technique. In all patients the mean heart rate (HR) during the scan was used as a criteria to divide the population in two groups of 60 patients each. In one group (Low HR) the 60 patients with lower heart rates, and in the other group (High HR) the patients with higher heart rates. In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (>or=50% lumen reduction) was evaluated in vessels >or=2 mm of diameter using quantitative CA as reference standard. The difference in diagnostic accuracy were compared with a Chi(2) test and a p<0.05 was considered significant. RESULTS: There was no significant difference between the two groups regarding age, gender, weight, mean intravascular attenuation, and calcium score. Overall 1,310 (652 for Low HR and 658 for High HR) segments with 219 (105 for Low HR and 114 for High HR) significant lesions were available for the analysis. The average heart rate was 52+/-4 HU and 63+/-5 HU for Low HR and High HR, respectively (p<0.001). The sensitivity and specificity were 92 and 96% for Low HR and 90 and 92% for High HR (p<0.05). There were 22 vs. 44 false positives, and 8 vs. 12 false negatives in the Low HR and High HR, respectively. CONCLUSION: Increasing HR significantly deteriorates diagnostic accuracy in MSCT-CA.

Chi-Square Distribution↗

Four-dimensional multislice computed tomography for determination of respiratory lung tumor motion in conformal radiotherapy.

PURPOSE: We used four-dimensional multislice spiral computed tomography (MSCT) to determine respiratory lung-tumor motion and compared this strategy to common clinical practice in conformal radiotherapy treatment-planning imaging. METHODS AND MATERIALS: The entire lung volume of 10 consecutive patients with 14 lung metastases were scanned by a 16-slice MSCT. During the scans, patients were instructed to breathe through a spirometer that was connected to a laptop computer. For each patient, 10 stacks of 1.5-mm slices, equally distributed throughout the respiratory cycle, were reconstructed from the acquired MSCT data. The lung tumors were manually contoured in each data set. For each patient, the tumor-volume contours of all data sets were copied to 1 data set, which allowed determination of the volume that encompassed all 10 lung-tumor positions (i.e., the tumor-traversed volume [TTV]) during the respiratory cycle. The TTV was compared with the 10 tumor volumes contoured for each patient, to which an empiric respiratory-motion margin was added. The latter target volumes were designated internal-motion included tumor volume (IMITV). RESULTS: The TTV measurements were significantly smaller than the reference IMITV measurements (5.2 +/- 10.2 cm(3) and 10.1 +/- 13.7 cm(3), respectively). All 10 IMITVs for 2 of the 4 tumors in 1 subject completely encompassed the TTV. All 10 IMITVs for 3 tumors in 2 patients did not show overlap with up to 35% of the corresponding TTV. The 10 IMITVs for the remaining tumors either completely encompassed the corresponding TTV or did not show overlap with up to 26% of the corresponding TTV. CONCLUSIONS: We found that individualized determination of respiratory lung-tumor motion by four-dimensional respiratory-gated MSCT represents a better and simple strategy to incorporate periodic physiologic motion compared with a generalized approach. The former strategy can, therefore, improve common and state-of-the-art clinical practice in conformal radiotherapy.

Aged↗

Noninvasive assessment of coronary plaque burden using multislice computed tomography.

We performed coronary plaque imaging with 16-row multislice computed tomography in 85 patients who had stable angina pectoris and a high pretest likelihood of having coronary plaque to evaluate plaque burden, i.e., extent (number of diseased coronary segments) and size (small vs large) of plaque. We also assessed type of plaque (calcified, noncalcified, or mixed) and its anatomic distribution. Of 85 patients included, 78 (92%) had fully evaluable multislice computed tomograms that allowed assessment of coronary plaque burden, including major and side branches (>or=2 mm), yielding a total of 855 segments. These 78 patients (92% men; mean age +/- SD 58 +/- 11.5 years) were in sinus rhythm, with heart rates of <70 beats/min (spontaneous or induced by beta blocker). Plaque was detected in 57% of all segments (487 of 855). The mean number of segments with plaque per patient +/- SD was 6.2 +/- 3.9. Plaque was classified as large in 33% of segments and small in 67%. Overall, 65% of plaques were calcified, 24% were noncalcified, and 11% were mixed. Plaques were predominantly located in the proximal and middle segments of the main coronary vessels.

Coronary Angiography↗

Impact of coronary calcium score on diagnostic accuracy for the detection of significant coronary stenosis with multislice computed tomography angiography.

One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent multislice computed tomography of the heart and conventional coronary angiography were retrospectively selected. The population was divided into 2 groups depending on their calcium score (CS) (e.g., low CS and high CS). The diagnostic accuracy of multislice computed tomographic scans for detecting significant lesions (>50% lumen reduction) in both groups was compared with quantitative coronary angiography. The sensitivity and specificity of multislice computed tomography were 90% and 92%, and 97% and 91% for low and high CS groups, respectively.

Calcinosis↗

3D reconstruction techniques made easy: know-how and pictures.

Three-dimensional reconstructions represent a visual-based tool for illustrating the basis of three-dimensional post-processing such as interpolation, ray-casting, segmentation, percentage classification, gradient calculation, shading and illumination. The knowledge of the optimal scanning and reconstruction parameters facilitates the use of three-dimensional reconstruction techniques in clinical practise. The aim of this article is to explain the principles of multidimensional image processing in a pictorial way and the advantages and limitations of the different possibilities of 3D visualisation.

Audiovisual Aids↗

Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography.

Assessment of attenuation (measured in Hounsfield units, HU) of human coronary plaques was performed using multislice computed tomography (MSCT) in an ex vivo model. In three ex vivo specimens of left coronary arteries in oil, MSCT was performed after intracoronary injection of four solutions of contrast material (400 mgI/ml iomeprol). The four solutions were diluted as follows: 1/infinity, 1/200, 1/80, and 1/20. All scans were performed with the following parameters: slices/collimation 16/0.75 mm, rotation time 375 ms. Each specimen was scored for the presence of atherosclerotic plaques. In each plaque the attenuation was measured in four regions of interest for lumen, plaque (non-calcified thickening of the vessel wall), calcium, and surrounding (oil surrounding the vessel). The results were compared with a one-way analysis of variance test and were correlated with Pearson's test. There were no significant differences in the attenuation of calcium and oil in the four solutions. The mean attenuation in the four solutions for lumen (35+/-10, 91+/-7, 246+/-18, 511+/-89 HU) and plaque (22+/-22, 50+/-26, 107+/-36, 152+/-67 HU) was significantly different between each decreasing dilution (p<0.001). The mean attenuation of lumen and plaque of coronary plaques showed high correlation, while the values were significantly different (r=0.73; p<0.001). Intracoronary attenuation modifies significantly the attenuation of plaques assessed with MSCT.

Cadaver↗

Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation.

The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1+/-2.4 preprocedural versus 18.6+/-2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2+/-0.2 versus 1.2+/-0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1+/-2.5 mm versus 16.5+/-2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up.

Atrial Fibrillation↗

Recovery of left ventricular function after primary angioplasty for acute myocardial infarction.

AIMS: To study recovery of segmental wall thickening (SWT), ejection fraction (EF), and end-systolic volume (ESV) after acute myocardial infarction (AMI) in patients who underwent primary stenting with drug-eluting stents. Additionally, to evaluate the predictive value of magnetic resonance imaging (MRI)-based myocardial perfusion and delayed enhancement (DE) imaging. METHODS AND RESULTS: Twenty-two patients underwent cine-MRI, first-pass perfusion, and DE imaging 5 days after successful placement of a drug-eluting stent in the infarct-related coronary artery. Regional myocardial perfusion and the transmural extent of DE were evaluated. A per patient perfusion score was calculated and consisted of a summation of all segmental scores. Myocardial infarct size was quantified by measuring the volume of DE. At 5 months after AMI, cine-MRI was performed and SWT, EF, and ESV were quantified. EF increased from 48+/-11 to 55+/-9% (P<0.01). SWT at 5 months was inversely related to baseline segmental DE scores (P<0.001) and segmental perfusion scores (P<0.001). EF and ESV at 5 months were related to acute infarct size (R(2)=0.65; P<0.001 and R(2)=0.78; P<0.001, respectively) and the calculated perfusion score (R(2)=0.23; P=0.02 and R(2)=0.14; P=0.09, respectively) at baseline. CONCLUSION: Marked recovery of left ventricular function was observed in patients receiving a drug-eluting stent for AMI. DE imaging appears to be a better prognosticator than perfusion imaging.

Analysis of Variance↗

Benign focal liver lesions: spectrum of findings on SonoVue-enhanced pulse-inversion ultrasonography.

The prevalence of benign focal liver lesions (BFLL) is high both in the general population and in patients with known malignancies. The gray-scale ultrasound (US) technique is usually the first-line imaging modality used in the radiological workup of such lesions, but unfortunately it lacks specificity. Furthermore, Doppler examination may often be unsatisfactory owing to motion artefacts, or when small or deeply located lesions are evaluated. Recently, microbubble-based contrast agents used in combination with gray-scale US techniques, which are very sensitive to nonlinear behavior of microbubbles, have led to a better depiction of both microvasculature and macrovasculature of focal hepatic masses, thus improving the reliability of using US in the assessment of liver tumors. This review illustrates the spectrum of enhancement patterns of BFLL on contrast-enhanced ultrasonography with SonoVue, a second-generation microbubble-based contrast agent.

Adenoma, Liver Cell↗

Value of preprocedure multislice computed tomographic coronary angiography to predict the outcome of percutaneous recanalization of chronic total occlusions.

We performed multislice computed tomographic coronary angiography in 45 patients who had chronic total occlusions and were scheduled for percutaneous recanalization. Multivariate analysis identified a blunt stump (by conventional angiography), occlusion length >15 mm, and severe calcification (by multislice computed tomographic coronary angiography) as independent predictors of procedural failure.

Coronary Angiography↗

Improved diagnostic accuracy with 16-row multi-slice computed tomography coronary angiography.

OBJECTIVES: We sought to compare the diagnostic value of multi-slice computed tomography (MSCT) coronary angiography (CA) to detect significant stenoses (> or =50% lumen diameter reduction) with that of invasive CA. BACKGROUND: The latest 16-row MSCT scanner has a faster rotation time (375 ms) and permits scanning with a higher X-ray tube current (500 to 600 mA) during MSCT CA when compared with previous scanners. METHODS: We studied 51 patients (37 men, mean age 58.9 +/- 10.0 years) with stable angina or atypical chest pain. Patients with pre-scan heart rates > or =70 beats/min received oral beta-blockade. The heart was scanned after intravenous injection of 100 ml contrast (iodine content, 400 mg/ml). Mean scan time was 18.9 +/- 1.0 s. The MSCT scans were analyzed by two observers unaware of the results of invasive angiography, and all available coronary branches > or =2 mm were included. RESULTS: Invasive CA demonstrated normal arteries in 16% (8 of 51), non-significant disease in 21% (11 of 51), single-vessel disease in 37% (19 of 51), and multi-vessel disease in 26% (13 of 51) of patients. There were 64 significant lesions. Sensitivity, specificity, and positive and negative predictive values for detection of significant lesions on a segment-based analysis were 95% (61 of 64, 95% confidence interval [CI] 86 to 99), 98% (537 of 546, 95% CI 96 to 99), 87% (61 of 70, 95% CI 76 to 98), and 99% (537 of 540, 95% CI 98 to 99), respectively. All patients with angiographically normal coronary arteries or significant lesions were correctly identified. Three of 11 patients with <50% lesions were incorrectly classified as having single-vessel disease. CONCLUSIONS: The 16-row MSCT CA reliably detects significant coronary stenoses in patients with atypical chest pain or stable angina pectoris.

Coronary Angiography↗

Multislice CT coronary angiography: how to do it and what is the current clinical performance?

The introduction of multislice computed tomography (MSCT) has allowed non-invasive coronary angiography. Although widely applied, extensive information on technical details of the technique is lacking. This survey offers detailed information on patient preparation, data acquisition, reconstruction and interpretation. In addition, a summary of the available studies using MSCT for non-invasive angiography is provided. Based on pooled analysis of direct comparisons between MSCT and invasive angiography, the weighted mean sensitivity and specificity of current 16-slice MSCT for the detection of coronary artery disease are 88% and 96%, respectively. At present, the technique is particularly well suited for reliable exclusion of coronary artery disease. It is important to emphasise that MSCT only provides anatomical images, visualising the presence of atherosclerosis; information on the haemodynamic significance of these lesions (i.e. ischaemia) cannot be derived.

Clinical Trials as Topic↗