IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 7. Certification of four reference materials for the determination of enzymatic activity of gamma-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase accord.

This paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase. A document describing the determination of preliminary reference values is also in preparation. The certification of the catalytic activity concentrations as determined by the recently elaborated IFCC primary reference methods at 37 degrees C of four enzyme preparations, namely IRMM/IFCC 452 (gamma-glutamyltransferase), IRMM/IFCC 453 (lactate dehydrogenase 1), IRMM/IFCC 454 (alanine aminotransferase) and IRMM/IFCC 455 (creatine kinase) is described. Homogeneity data were derived from previous results. Stability was assessed using recently obtained data as well as data from previous stability studies. The collaborative study for value assignment was performed under a strict quality control scheme to ensure traceability to the primary reference method. Uncertainty of the materials was assessed in compliance with the Guide to the Expression of Uncertainty in Measurement. The certified values obtained at 37 degrees C are 1.90 microkat/l +/- 0.04 microkat/l (114.1 U/l +/- 2.4 U/l), for gamma-glutamyltransferase, 8.37 microkat/l +/- 0.12 microkat/l (502 U/l +/- 7 U/l), for lactate dehydrogenase 1, 3.09 microkat/l +/- 0.07 microkat/l (186 U/l +/- 4 U/l), for alanine aminotransferase and 1.68 microkat/l +/- 0.07 microkat/l (101 U/l +/- 4 U/l), for creatine kinase. The materials are intended for internal quality control as well as for the evaluation of test systems as required by recent European Union legislation. Furthermore, the materials can be used to transfer accuracy from a reference method to a routine procedure provided the procedures exhibit the same analytical specificity and the certified materials are commutable.

Alanine Transaminase↗

Errors in laboratory medicine.

BACKGROUND: The problem of medical errors has recently received a great deal of attention, which will probably increase. In this minireview, we focus on this issue in the fields of laboratory medicine and blood transfusion. METHODS: We conducted several MEDLINE queries and searched the literature by hand. Searches were limited to the last 8 years to identify results that were not biased by obsolete technology. In addition, data on the frequency and type of preanalytical errors in our institution were collected. RESULTS: Our search revealed large heterogeneity in study designs and quality on this topic as well as relatively few available data and the lack of a shared definition of "laboratory error" (also referred to as "blunder", "mistake", "problem", or "defect"). Despite these limitations, there was considerable concordance on the distribution of errors throughout the laboratory working process: most occurred in the pre- or postanalytical phases, whereas a minority (13-32% according to the studies) occurred in the analytical portion. The reported frequency of errors was related to how they were identified: when a careful process analysis was performed, substantially more errors were discovered than when studies relied on complaints or report of near accidents. CONCLUSIONS: The large heterogeneity of literature on laboratory errors together with the prevalence of evidence that most errors occur in the preanalytical phase suggest the implementation of a more rigorous methodology for error detection and classification and the adoption of proper technologies for error reduction. Clinical audits should be used as a tool to detect errors caused by organizational problems outside the laboratory.

Blood Transfusion↗