Fast low-angle dual spin-echo (FLADE): a new robust pulse sequence for structural imaging of trabecular bone.

Mechanical strength and fracture resistance of trabecular bone (TB) are largely determined by the structural arrangement of individual trabeculae. Fast 3D spin-echo approaches are preferable to gradient echoes in that they are less sensitive to local induced gradients at the bone/marrow interface caused by magnetic susceptibility difference between the two tissues. FLASE is a 3D pulse sequence that serves this purpose. Here, we present a new pulse sequence dubbed FLADE (fast low-angle dual spin-echo) that overcomes some of the limitations inherent to FLASE, such as sensitivity to artifactual stimulated echoes. The double-echo sequence features a flip angle <90 degrees allowing for TR << T(1). The second phase-reversal pulse has the dual function of creating a second echo and restoring inverted longitudinal magnetization. The prolonged TR, made possible by sampling only half of k(z)-space, is used to collect navigator echoes in adjacent slabs for sensing subpixel translational displacements. FLADE is shown to provide SNR comparable to FLASE while having narrower point-spread function and being more robust to imperfections in the nonselective 180 degree pulses. Structural parameters derived from the in vivo images with the two pulse sequences are highly correlated, therefore suggesting that clinical data obtained with either pulse sequence can be merged.

Bone and Bones↗

General algorithm for automated off-center MRI.

A general formula was derived that automatically modifies any MRI pulse sequence to realize arbitrary field-of-view (FOV) shifts. Unlike conventional techniques for implementing off-center MRI, the new method is completely automatic and can therefore be incorporated into the scanner hardware or software, thereby simplifying the development of MRI pulse sequences. The algorithm was incorporated into a visual pulse sequence programming environment, and several pulse sequences were programmed and tested at various off-center locations using the new technique. Unless there is significant background field inhomogeneity or gradient nonlinearity, research sequences employing the automatic technique need only be programmed and tested at the gradient isocenter, whereas with conventional methods, artifacts can sometimes depend on the position of the FOV.

Algorithms↗

Measurement of phosphorus content in normal and osteomalacic rabbit bone by solid-state 3D radial imaging.

In osteomalacia decreased mineralization reduces the stiffness and static strength of bone. We hypothesized that hypomineralization in osteomalacic bone could be quantified by solid-state (31)P magnetic resonance imaging (SS-MRI). Hypomineralization was measured with a 3D radial imaging technique at 162 MHz (9.4T) in rabbit cortical bone of hypophosphatemic (HY) and normophosphatemic (NO) animals. The results were compared with those obtained by quantitative micro-CT (micro-CT) and (31)P solution NMR. 3D images of 277 microm isotropic voxel size were obtained in 1.7 hr with SNR approximately 9. Mineral content was lower in the HY relative to the NO group (SS-MRI: 9.48 +/- 0.4 vs. 11.15 +/- 0.31 phosphorus wet wt %, P < 0.0001; micro-CT: 1114.6 +/- 28.3 vs. 1175.7 +/- 23.5 mg mineral/cm(3); P = 0.003). T(1) was shorter in the HY group (47.2 +/- 3.5 vs. 54.1 +/- 2.7 s, P = 0.004), which suggests that relaxation occurs via a dipole-dipole (DD) mechanism involving exchangeable water protons, which are more prevalent in bone from osteomalacic animals.

Anatomy, Cross-Sectional↗

Structural MRI of carotid artery atherosclerotic lesion burden and characterization of hemispheric cerebral blood flow before and after carotid endarterectomy.

Collateral circulation plays a major role in maintaining cerebral blood flow (CBF) in patients with internal carotid artery (ICA) stenosis. CBF can remain normal despite severe ICA stenosis, making the benefit of carotid endarterectomy (CEA) or stenting difficult to assess. Before and after surgery, we assessed CBF supplied through the ipsilateral (stenotic) or contralateral ICA individually with a novel hemisphere-selective arterial spin-labeling (ASL) perfusion MR technique. We further explored the relationship between CBF and ICA obstruction ratio (OR) acquired with a multislice black-blood imaging sequence. For patients with unilateral ICA stenosis (n = 19), conventional bilateral labeling did not reveal interhemispheric differences. With unilateral labeling, CBF in the middle cerebral artery (MCA) territory on the surgical side from the ipsilateral supply (53.7 +/- 3.3 ml/100 g/min) was lower than CBF in the contralateral MCA territory from the contralateral supply (58.5 +/- 2.7 ml/100 g/min), although not statistically significant (p = 0.09). The ipsilateral MCA territory received significant (p = 0.02) contralateral supply (7.0 +/- 2.7 ml/100 g/min), while ipsilateral supply to the contralateral side was not reciprocated. After surgery (n = 11), ipsilateral supply to the MCA territory increased from 57.3 +/- 5.7 to 67.3 +/- 5.4 ml/100 g/min (p = 0.03), and contralateral supply to the ipsilateral MCA territory decreased. The best predictor of increased CBF on the side of surgery was normalized presurgical ipsilateral supply (r(2) = 0.62, p = 0.004). OR was less predictive of change, although the change in normalized contralateral supply was negatively correlated with OR(excess) (=OR(ipsilateral) - OR(contralateral)) (r(2) = 0.58, p = 0.006). The results demonstrate the effect of carotid artery stenosis on blood supply to the cerebral hemispheres, as well as the relative role of collateral pathways before surgery and redistribution of blood flow through these pathways after surgery. Unilateral ASL may better predict hemodynamic surgical outcome (measured by improved perfusion) than ICA OR.

Aged↗

Reproducibility and error sources of micro-MRI-based trabecular bone structural parameters of the distal radius and tibia.

The mechanical competence of trabecular bone is significantly determined, next to material density, by its three-dimensional (3D) structure. Recent advances in micromagnetic resonance imaging (micro-MRI) acquisition and processing techniques allow the 3D trabecular structure to be analyzed in vivo at peripheral sites such as the distal radius and tibia. The practicality of micro-MRI-based noninvasive virtual bone biopsy (VBB) for longitudinal studies of patients hinges on the reproducibility of the derived structural parameters, which largely determine the size of the effect that can be detected at a given power and significance level. In this paper, the reproducibility of micro-MRI-derived trabecular bone structure measures was examined by performing repeat studies in six healthy subjects in whom the distal aspects of the radius and tibia were scanned with a 3D spin-echo sequence at 137 x 137 x 410 microm3 voxel size. Bone volume fraction (BV/TV) and digital topological analysis (DTA) structural parameters including the topological bone surface-to-curve ratio (SCR) and topological erosion index (TEI) were evaluated after subjecting the raw images to a cascade of processing steps. The average coefficient of variation was 4-7% and was comparable for the two anatomic sites and for all parameters measured. The reliability expressed in terms of the intraclass correlation coefficient ranged from 0.95 to 0.97 in the radius and 0.68 to 0.92 in the tibia. Error analysis based on simulations suggests involuntary patient motion, primarily rotation, to be the chief source of imprecision, followed by failure to accurately match the analysis volumes in repeat studies.

Adult↗

Multipoint mapping for imaging of semi-solid materials.

Multipoint k-space mapping is a hybrid between constant-time (single-point mapping) and spin-warp imaging, involving sampling of a k-line segment of r points per TR cycle. In this work the method was implemented for NMR imaging of semi-solid materials on a 400 MHz micro-imaging system and two different k-space sampling strategies were investigated to minimize the adverse effects from relaxation-induced k-space signal modulation. Signal attenuation from T(2) decay results in artifacts whose nature depends on the k-space sampling strategy. The artifacts can be minimized by increasing the readout gradient amplitude, by PSF deconvolution or by oversampling in readout direction. Finally, implementation of a T(2) selective RF excitation demonstrates the feasibility of obtaining short-T(2) contrast even in the presence of tissues with long-T(2). The method's potential is illustrated with 3D proton images of short-T(2) materials such as synthetic polymers and bone.

Animals↗

A noncontact, nondestructive method for quantifying intratissue deformations and strains.

The function of soft connective tissues is frequently characterized by quantifying tissue strain (e.g., during joint motion). Conventional techniques for quantifying tendon and ligament strain typically provide surface measures, using markers, stain lines or instrumentation that may influence the tissue. An alternative approach is to quantify intratendinous strain by applying texture correlation analysis to magnetic resonance (MR) images. This paper reports the accuracy and reproducibility of this approach by (1) assessing the reproducibility of MR images, (2) assessing texture correlation accuracy using simulated displacements, and (3) comparing texture correlation measures of displacement and strain from MR images to conventional techniques.

Cadaver↗

Water magnetic relaxation dispersion in biological systems: the contribution of proton exchange and implications for the noninvasive detection of cartilage degradation.

Magnetic relaxation has been used extensively to study and characterize biological tissues. In particular, spin-lattice relaxation in the rotating frame (T(1rho)) of water in protein solutions has been demonstrated to be sensitive to macromolecular weight and composition. However, the nature of the contribution from low frequency processes to water relaxation remains unclear. We have examined this problem by studying the water T(1rho) dispersion in peptide solutions ((14)N- and (15)N-labeled), glycosaminoglycan solutions, and samples of bovine articular cartilage before and after proteoglycan degradation. We find in model systems and tissue that hydrogen exchange from NH and OH groups to water dominates the low frequency water T(1rho) dispersion, in the context of the model used to interpret the relaxation data. Further, low frequency dispersion changes are correlated with loss of proteoglycan from the extra-cellular matrix of articular cartilage. This finding has significance for the noninvasive detection of matrix degradation.

Amino Acid Sequence↗

Trabecular bone volume fraction mapping by low-resolution MRI.

Trabecular bone volume fraction (TBVF) is highly associated with the mechanical competence of trabecular bone. TBVF is ordinarily measured by histomorphometry from bone biopsies or, noninvasively, by means of high-resolution microcomputed tomography and, more recently, by micro-MRI. The latter methods require spatial resolution sufficient to resolve trabeculae, along with segmentation techniques that allow unambiguous assignment of the signal to bone or bone marrow. In this article it is shown that TBVF can be measured under low-resolution conditions by exploiting the attenuation of the MR signal resulting from fractional occupancy of the imaging voxel by bone and bone marrow, provided that a reference signal is available from a marrow volume devoid of trabeculation. The method requires accurate measurement of apparent proton density, which entails correction for various sources of error. Key among these are the spatial nonuniformity in the RF field amplitude and effects of the slice profile, which are determined by B(1) field mapping and numerical integration of the Bloch equations, respectively. By contrast, errors from variations in bone marrow composition (hematopoietic vs. fatty) between trabecular and reference site are predicted to be small and usually negligible. The method was evaluated in phantoms and in vivo in the distal radius and found to be accurate to 1% in marrow volume fraction. Finally, in a group of 12 patients of varying skeletal status, TBVF in the calcaneus was found to strongly correlate with integral bone mineral density of the lumbar vertebrae (r(2) = 0.83, p < 0.0001). The method may fail in large imaging objects such as the human trunk at high magnetic field where standing wave and RF penetration effects cause intensity variations that cannot be corrected. Magn Reson Med 46:103-113, 2001.

Animals↗

Digital topological analysis of in vivo magnetic resonance microimages of trabecular bone reveals structural implications of osteoporosis.

Osteoporosis is a disease characterized by bone volume loss and architectural deterioration. The majority of work aimed at evaluating the structural implications of the disease has been performed based on stereologic analysis of histomorphometric sections. Only recently noninvasive imaging methods have emerged that provide sufficient resolution to resolve individual trabeculae. In this article, we apply digital topological analysis (DTA) to magnetic resonance microimages (mu-MRI) of the radius obtained at 137 x 137 x 350 microm3 voxel size in a cohort of 79 women of widely varying bone mineral density (BMD) and vertebral deformity status. DTA is a new method that allows unambiguous determination of the three-dimensional (3D) topology of each voxel in a trabecular bone network. The analysis involves generation of a bone volume fraction map, which is subjected to subvoxel processing to alleviate partial volume blurring, followed by thresholding and skeletonization. The skeletonized images contain only surfaces, profiles, curves, and their mutual junctions as the remnants of trabecular plates and rods after skeletonization. DTA parameters were compared with integral BMD in the lumbar spine and femur as well as MR-derived bone volume fraction (BV/TV). Vertebral deformities were determined based on sagittal MRIs of the spine with a semiautomatic method and the number of deformities counted after threshold setting. DTA structural indices were found the strongest discriminators of subjects with deformities from those without deformities. Subjects with deformities (n = 29) had lower topological surface (SURF) density (p < 0.0005) and surface-to-curve ratio (SCR; a measure of the ratio of platelike to rodlike trabeculae; p < 0.0005) than those without. Profile interior (PI) density, a measure of intact trabecular rods, was also lower in the deformity group (p < 0.0001). These data provide the first in vivo evidence for the structural implications inherent in postmenopausal osteoporosis accompanying bone loss, that is, the conversion of trabecular plates to rods and disruption of rods due to repeated osteoclastic resorption.

Adult↗

In vivo MR micro imaging with conventional radiofrequency coils cooled to 77 degrees K.

Cryogenically cooled conventional surface coils are shown to provide significant signal-to-noise ratio (SNR) gains for MR micro imaging of tissue structure in vivo. Measurements are described which employ a simple, all-polyvinyl chloride (PVC) vacuum dewar capable of maintaining a bath of liquid nitrogen around the coil, within 5 mm of the tissue to be imaged. Images acquired in vivo at 64 MHz with a 2-cm diameter copper coil cooled to 77 K demonstrated a gain in SNR of approximately 2.7 +/- 0.3 relative to those obtained with the same coil at room temperature under otherwise identical conditions. This increase is consistent with the reduction in coil resistance and the minor contribution to overall resistance from the imaging object. The performance of the coil is illustrated with images from the human finger and rabbit eye and potential applications are discussed.

Animals↗

Postprocessing technique to correct for background gradients in image-based R*(2) measurements.

Background static magnetic field gradients are a source of signal loss in gradient-echo imaging, as they typically result from discontinuity in the magnetic susceptibility at air-tissue boundaries. Moreover, these induced gradients severely compromise the measurement of R*(2), the effective transverse relaxation rate, which is of interest in many biomedical applications of MRI. Since the slice thickness is usually larger than the in-plane pixel dimensions, gradients parallel to the slice-select direction are of particular concern. In this work, a post-processing technique is introduced which attempts to correct the signal on the assumption that the background gradients are approximately linear across the voxel and the signal decay in the absence of these gradients is exponential. In this case, the time-domain signal is weighted by a sinc function characterized by the amplitude G(b) of the background gradient, which is typically not known a priori. The algorithm searches for the estimate of G(b) which yields the optimum fit of the corrected experimental data to an exponential. It is shown to be effective as long as this gradient is below a critical threshold. Evaluation in a phantom and in the human brain at 1.5 and 4 T demonstrates that this method can restore R(2)* in spite of the apparent rate constant exceeding the true value by up to 100%. Contrary to prospective correction techniques, the approach presented in this study does not prolong scan time.

Adult↗

High-speed spectroscopic imaging for cancellous bone marrow R(2)* mapping and lipid quantification.

In this work an interleaved multiple-gradient-echo chemical shift imaging (IMGE-CSI) technique was designed, implemented and evaluated at 1.5 and 4T for high-resolution lipid quantification and R(2)* measurement in-vivo. The method is analogous to echo planar CSI but utilizes conventional gradient echoes, exploiting the principle of spectroscopic bandwidth extension by interleaving temporally offset gradient-echo trains. It is shown that IMGE-CSI is able to measure true fat volume fraction in oil/water mixtures with high accuracy, not possible with Dixon-type methods which approximate the spectrum as consisting of only two spectral components. Correlation of the CSI- derived volume fractions with volumetry afforded r(2) > 0.99 with a slope of 0.98. The method is shown to be able to quantify regional variations in bone marrow composition in vivo with a spatial resolution of 2.5 x 2.5 x 5 mm(3.) R(2)* was obtained by multi-line spectral curve fitting. For the measurement of R(2)* in cancellous bone marrow the method is shown to agree well with time-domain fitting techniques but is superior in instances where the marrow has both hematopoietic and fatty constituents. Finally, excellent inter-scan reproducibility (1% coefficient of variation for global means and medians) was achieved, yielding r(2) = 0.98 of the test-retest correlation for three scans in four test subjects. In conclusion, IMGE-CSI is found to enable highly accurate lipid quantification and measurement of cancellous bone marrow R(2)* at spatial resolutions and scan times typical of standard clinical protocols.

Bone Marrow↗

Relationship between cancellous bone induced magnetic field and ultrastructure in a rat ovariectomy model.

The site-dependent variations in trabecular bone morphology were studied in the rat tibia by magnitude and phase difference three-dimensional nuclear magnetic resonance microscopy and image processing, and the implications of ovariectomy were evaluated. Specimens excised from the proximal tibial metaphysis in ovariectomized (n = 7) and intact control (n = 4) rats were imaged at 9.4T with their anatomic axes parallel to the direction of the magnetic field. An echo-offset 3D rapid spin-echo excitation pulse sequence was used to generate phase difference maps, from which the standard deviation of the phase difference, sigma(delta psi), was calculated. In addition, a fictitious rate constant, R2', was calculated from the slope of the exponential portion of the Fourier transform of the phase difference histogram. Trabecular bone volume fraction was also determined in the same volume of interest. The results show strong correlations between bone volume fraction and both sigma(delta psi) and R2', suggesting that these parameters could be useful for nondestructive assessment of trabecular bone volume.

Animals↗

Topological analysis of trabecular bone MR images.

Recently, imaging techniques have become available which permit nondestructive analysis of the three-dimensional (3-D) architecture of trabecular bone (TB), which forms a network of interconnected plates and rods. Most osteoporotic fractures occur at locations rich in TB, which has spurred the search for architectural parameters as determinants of bone strength. In this paper, we present a new approach to quantitative characterization of the 3-D microarchitecture of TB, based on digital topology. The method classifies each voxel of the 3-D structure based on the connectivity information of neighboring voxels. Following conversion of the 3-D digital image to a skeletonized surface representation containing only one-dimensional (1-D) and two-dimensional (2-D) structures, each voxel is classified as a curve, surface, or junction. The method has been validated by means of synthesized images and has subsequently been applied to TB images from the human wrist. The topological parameters were found to predict Young's modulus (YM) for uniaxial loading, specifically, the surface-to-curve ratio was found to be the single strongest predictor of YM (r2 = 0.69). Finally, the method has been applied to TB images from a group of patients showing very large variations in topological parameters that parallel much smaller changes in bone volume fraction (BVF).

Aged↗

Cross-sectional study of osteopenia with quantitative MR imaging and bone densitometry.

PURPOSE: To evaluation the cancellous bone-induced intravoxel spin dephasing rate (R2') and its relationship to bone mineral density and marrow fat and to examine these parameters as predictors of vertebral fracture status. MATERIALS AND METHODS: R2' and R2, the rate constants for reversible and irreversible spin dephasing, and marrow fat fraction were measured in the lumbar vertebrae and proximal femur. One hundred thirty-nine subjects (mean age, 62.4 years +/- 11.4 [SD]; 33 men, 106 women) had spinal dual-energy x-ray absorptiometric bone mineral density (BMD) T scores ranging from +3 to -5. R2', BMD, and bone marrow composition as determinants of vertebral fracture status were examined. RESULTS: Strongest single predictors of fracture status for BMD and R2' were the Ward triangle (r(2) = 0.48) and trochanter (r(2) = 0.37), respectively. Combined, the two parameters and sites increased fracture prediction (r(2) = 0. 62), whereas the combination of multiple BMD sites did not. Multivariate regression involving marrow fat fraction further improved fracture status prediction. R2' was correlated with BMD at all sites, although slopes differed by a factor of up to 2.5, which reflected differences in trabecular orientation relative to the static field. R2, the true transverse relaxation rate, was negatively correlated with marrow fat fraction. A non-age-related increase in marrow fat fraction in osteoporosis parallels earlier findings in animal models. CONCLUSION: Cancellous bone marrow R2' measured in the proximal femur provides information, which, with BMD, improves prediction of vertebral fracture status.

Absorptiometry, Photon↗