Search PubMed⌕ Search

Biomedical subjects

F W Scheller

Publications and source records attributed to F W Scheller.

At least 37 records · Page 2Linked to original sources

Enzymes and antibodies in organic media: analytical applications.

This chapter outlines the influence of organic solvents on antibodies, enzymes, and their reactions, the different kinds of enzyme-solvent systems and the various advantages of organic solvents compared with water, with respect to analytical purposes. Examples for electrochemical, optical and thermometric assays in organic solvents are given. The potential of organic solvents for the modification of immunoassays is exemplified, opening up new applications.

Antibodies↗

Enzymatic substrate recycling electrodes.

A weak chemical signal might result in a large response when biochemically amplified. Enzymatic recycling of the analyte is one of the biochemical ways of providing an effective increase in biosensor sensitivity by several orders of magnitude. The enhancement of sensitivity is provided by consecutive consumption and generation of the analyte on the sensor surface. The principle of enzymatic substrate regeneration using bioelectrocatalysis and coupled enzymes is shortly reviewed and illustrated with some recent developments of biosensors for catecholamines, and its potential for electrochemical immunoassays is outlined.

Biosensing Techniques↗

Ultrasensitive bienzyme sensor for adrenaline.

A biosensor consisting of an analyte-recycling two-enzyme system using laccase (Coriolus hirsutus) and PQQ-dependent glucose dehydrogenase in combination with the electrochemical detection of oxygen depletion at a platinum electrode was used for adrenaline determination in the nano- and subnanomolar concentration range. Measurements were performed in a flow cell providing excellent baseline stability and fast recovery of the sensor. Improved design of the polymer matrix resulted in a lower detection limit of 200 pmol/l for adrenaline. The sensor has successfully been applied to the analysis of adrenaline in effluate of isolated rabbit hearts.

Animals↗

Novel instrumentation for real-time monitoring using miniaturized flow systems with integrated biosensors.

A prototype miniaturized Total Chemical Analysis System (muTAS) has been developed and applied to on-line monitoring of glucose and lactate in the core blood of anaesthetized dogs. The system consists of a highly efficient microdialysis sampling interface sited in a small-scale extracorporeal shunt circuit ('MiniShunt'), a silicon machined microflow manifold and integrated biosensor array for glucose and lactate detection with associated computer software for analytical process control. During in-vivo testing the device allowed real-time on-screen monitoring of glucose and lactate with system response times of less than 5 min, made possible by the small dead volume of the microflow system. On-line glucose and lactate measurements were made in the basal state as well as during intravenous infusion of glucose or lactate. The prototype muTAS is currently suitable for trend monitoring but refinements are necessary before application of the system for determination of individual lactate values.

Animals↗

Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid.

A bienzyme substrate-recycling biosensor in a flow injection analysis system is described for the sensitive measurement of alkaline phosphatase (ALP) and applied to the fast readout of a competitive immunoassay for the widely used pesticide 2,4-dichlorophenoxyacetic acid (2,4-D). The phenol-indicating biosensor consists of a Clark-type electrode covered by a membrane with coentrapped tyrosinase and quinoprotein glucose dehydrogenase. ALP dephosphorylates phenyl phosphate to phenol (K(m) = 36 microM) outside the flow system. Phenol is oxidized in the sensor membrane by the oxygen-consuming tyrosinase via catechol to o-quinone. The quinone is reconverted to catechol by glucose dehydrogenase. This substrate cycling results in a 350-fold amplified sensor response to phenol. The oxygen consumption of the enzyme couple in the presence of phenol is monitored as a decrease in current. A total of 3.2 fM ALP (320 zmol/ 100 microL) has been detected after a 57.5 min incubation with phenyl phosphate. All involved reagents are stable over the time of measurement. The sensor does not produce any measurable blank signals. The immunoassay detects 0.1 microgram/L 2,4-D, the maximum concentration for pesticides allowed in drinking water by European Community regulations. The applicability of this biosensor for fast immunoassay readout is demonstrated by a 2 min incubation. By comparison, a standard photometric method (p-nitrophenyl phosphate) requires overnight incubation.

2,4-Dichlorophenoxyacetic Acid↗

High sensitive competitive immunodetection of 2,4-dichlorophenoxyacetic acid using enzymatic amplification with electrochemical detection.

The amplification cycle consisting of NADH independent oligosaccharide dehydrogenase (ODH) and laccase has been recently reported to be highly sensitive to several catecholamines and p-aminophenol. A competitive immunoassay for 2,4-dichlorophenoxyacetic acid has been developed by combining this amplification cycle with beta-galactosidase as enzyme label resulting in p-aminophenol as product. The combination of enzymatic amplification cycles with a competitive immunoassay yields a highly sensitive measurement of 2,4-dichlorophenoxyacetic acid. Using a monoclonal antibody the linear range of the assay was between 0.02 and 100 ng/l and the c(50) was found at 0.2 ng/l; the detection limit was at 5 pg/l (25 fmol/l) corresponding to 5 amol.

Journal Article↗

Label-free observation of DNA-hybridisation and endonuclease activity on a wave guide surface using a grating coupler.

Hybridisation of nucleic acid oligomers to an immobilised target has been observed in real time using evanescent field technology. A biotinylated 24-mer with random sequence including the EcoRI recognition site was immobilised via streptavidin onto a grating coupler wave guide surface. Hybridisation of 22-mer, 15-mer and 8-mer was observed. Activity of restriction endonuclease EcoRI was visualised by measurement of the loss of bound DNA after incubation.

Base Sequence↗

Enhancing biosensor performance using multienzyme systems.

Enhancing the performance of biosensors, in terms of increasing the range of analytes that may be detected, and the sensitivity and specificity of the detection event, would improve the prospects for commercializing this technology. Coupling the catalytic activities of several enzymes is one approach being used to address these issues. Sequences of enzymes, where ligand binding triggers the activation of enzymes, or where biocatalytic pre-concentration of intermediates permits augmentation of the signal, may be used. In addition, enzymatic recycling of the analyte can be used to increase the sensitivity by several orders of magnitude.

Animals↗

Enzyme activation for activator and enzyme activity measurement.

A new sensing principle of enzyme activation is demonstrated for the determination of glycogen phosphorylase b and its allosteric effector AMP. As the indicator of the phosphorylase catalysed glycogen phosphorolysis, glucose-1-phosphate formation has been detected with an enzyme sequence comprising coentrapped alkaline phosphatase, mutarotase and glucose oxidase on a hydrogen peroxide indicating electrode. The optimized three-enzyme sensor was useful for the determination of 0.005-0.2 U.ml-1 glycogen phosphorylase a and b. A biosensor for AMP and inorganic phosphate has been developed by coupling glycogen entrapped phosphorylases to the three-enzyme indicator membrane. The measurement of AMP is based on the modulation of the phosphorylase b catalysed glycogen phosphorylating activity. The proposed sensor responds to AMP between 5 and 150 microM. The calibration graph of the reagentless phosphate sensor is linear between 0.05 and 1 mM.

Adenosine Monophosphate↗

Second generation biosensors.

Enzyme-membrane electrodes using glucose oxidase in combination with peroxide detection dominate in the field of laboratory analyzers for diluted samples. Using the same indication principle, extremely fast responding glucose sensors have been fabricated by covering thin metal electrodes with a porous enzyme layer. In the second generation auxiliary enzymes and/or co-reactants are coimmobilized with the analyte converting enzyme in order to improve the analytical quality and to simplify the performance. Following this line oxidizable interferences are suppressed by using a glucose oxidase/peroxidase complex which communicates with the electrode at a low working potential. Furthermore, fluctuations of pH or buffer capacity are ineffective when using a glucose oxidase/peroxidase layer covered fluoride FET in the potentiometric glucose determination. Enzymatic recycling of the analyte and/or accumulation of intermediates increase the sensitivity by several orders of magnitude. Inclusion of NAD bound to PEG in the glucose dehydrogenase layer allows a reagentless glucose measurement.

Biosensing Techniques↗

Amperometric bi-enzyme based biosensor for the detection of lactose--characterization and application.

Based on the glucose oxidase-beta-galactosidase sequence an enzyme probe for the specific determination of lactose has been developed. beta-Galactosidases from different sources have been compared, the sensor containing beta-galactosidase from Curvularia inaequalis has been characterized in respect of optimal pH, enzyme loading, apparent activity and functional stability. The response of the bi-enzyme probe depends linearly on lactose concentration between 0.02 and 3.00 mmol dm-3. The application to different milk and foodstuff samples resulted in good correlations toward enzymatic photometric (y = (0.956x-1.67) mmol dm-3) and infrared detection (y = (1.0772x-0.3909)%). Using a measuring frequency of 100 h-1 the serial imprecision is about 2% for diluted milk, urine, or foodstuff samples.

Animals↗

Glucose measurement in diluted blood.

The sensitivity, measuring range and lifetime of enzyme electrodes using glucose oxidase sandwiched between dialysis membranes or alternatively in a polyurethane layer directly on the surface of a platinum electrode are compared. The GOD modified electrode exhibits the highest sensitivity. However, the signal depends strongly on the stirring rate. Using the sandwich membranes up to 120 diluted blood samples per hour with a serial coefficient of variation below 1% can be analyzed.

Biosensing Techniques↗

Electrochemical immunoassays.

Immunoassays (IA) use the specific antigen antibody complexation for analytical purposes. Radioimmunoassays (RIA), fluorescence immunoassays (FIA) and enzyme immunoassays (EIA) are well established in clinical diagnostics. For the development of hand-held devices which can be used for point of care measurements, electrochemical immunoassays are promising alternatives to existing immunochemical tests. Moreover, for opaque or optically dense matrices electrochemical methods are superior. Potentiometric, capacitive and amperometric transducers have been applied for direct and indirect electrochemical immunoassays. However, due to their fast detection, broad linear range and low detection limit, amperometric transducers are preferred. Competitive and noncompetitive amperometric immunoassays have been developed with redox compounds or enzymes as labels. This review will give an overview of the most frequently applied principles in electrochemical immunoassays. The potential of an indirect competitive amperometric immunoassay for the determination of creatinine within nanomolar range and the circumvention of the most serious problem in electrochemical immunoassays, namely regeneration, will be discussed.

Animals↗