Search PubMed⌕ Search

Biomedical subjects

F W McLafferty

Publications and source records attributed to F W McLafferty.

At least 37 records · Page 2Linked to original sources

Thiamin biosynthesis in Escherichia coli. Identification of ThiS thiocarboxylate as the immediate sulfur donor in the thiazole formation.

ThiFSGH and ThiI are required for the biosynthesis of the thiazole moiety of thiamin in Escherichia coli. The overproduction, purification, and characterization of ThiFS and the identification of two of the early steps in the biosynthesis of the thiazole moiety of thiamin are described here. ThiS isolated from E. coli thiI+ is post-translationally modified by converting the carboxylic acid group of the carboxyl-terminal glycine into a thiocarboxylate. The thiI gene plays an essential role in the formation of the thiocarboxylate because ThiS isolated from a thiI- strain does not contain this modification. ThiF catalyzes the adenylation by ATP of the carboxyl-terminal glycine of ThiS. This reaction is likely to be involved in the activation of ThiS for sulfur transfer from cysteine or from a cysteine-derived sulfur donor.

Amino Acid Sequence↗

Creatine kinase: essential arginine residues at the nucleotide binding site identified by chemical modification and high-resolution tandem mass spectrometry.

Phenylglyoxal is an arginine-specific reagent that inactivates creatine kinase (CK). Previous results suggest that modification of the dimeric enzyme at a single arginine residue per subunit causes complete inactivation accompanied by the loss of nucleotide binding; the actual site of modification was not identified. Here, high-resolution tandem mass spectrometry (MS/MS) was used to identify three phenylglyoxal-modified Arg residues in monomeric rabbit muscle CK. Electrospray ionizaton Fourier-transform MS of the phenylglyoxal-modified CK that had lost approximately 80% activity identified three species: unmodified, once-modified (+116 Da), and twice-modified (+232 Da) enzyme in a ratio of approximately 1:4:1. MS/MS restricts the derivatized sites to P122-P212 and P283-V332, whereas MS of Lys-C digestions revealed two modified peptides, A266-K297 and G116-K137. The only Arg in A266-K297 is Arg-291 (invariant), whereas MS/MS of modified G116-K137 shows that two of the three sites Arg-129, Arg-131, or Arg-134 (all invariant) can contain the modification. The recently reported x-ray crystal structure for the octameric chicken mitochondrial CK indicates that its nucleotide triphosphate-binding site indeed contains the equivalent of R291, R129, and R131 reported here to be at the active site of rabbit muscle CK.

Animals↗

Efficient sequence analysis of the six gene products (7-74 kDa) from the Escherichia coli thiamin biosynthetic operon by tandem high-resolution mass spectrometry.

The 10(5) resolving power and MS/MS capabilities of Fourier-transform mass spectrometry provide electrospray ionization mass spectra containing >100 molecular and fragment ion mass values of high accuracy. Applying these spectra to the detection and localization of errors and modifications in the DNA-derived sequences of proteins is illustrated with the thiCEFSGH thiamin biosynthesis operon from Escherichia coli. Direct fragmentation of the multiply-charged intact protein ions produces large fragment ions covering the entire sequence; further dissociation of these fragment ions provides information on their sequences. For ThiE (23 kDa), the entire sequence was verified in a single spectrum with an accurate (0.3 Da) molecular weight (Mr) value, with confirmation from MS/MS fragment masses. Those for ThiH (46 kDa) showed that the Mr value (1 Da error) represented the protein without the start Met residue. For ThiF (27 kDa), MS/MS localized a sequence discrepancy to a 34 residue peptide. The first 107 residues of ThiC (74 kDa) were shown to be correct, with C-terminal heterogeneity indicated. For ThiG (predicted Mr = 34 kDa), ESI/FTMS showed two components of 7,310.74 (ThiS) and 26,896.5 Da (ThiG); MS/MS uncovered three reading frame errors and a stop codon for the first protein. MS/MS ions are consistent with 68 fragments predicted by the corrected ThiS/ThiG DNA sequences.

Amino Acid Sequence↗

Overexpression of recombinant proteins with a C-terminal thiocarboxylate: implications for protein semisynthesis and thiamin biosynthesis.

A facile and rapid method for the production of protein C-terminal thiocarboxylates on DNA-encoded polypeptides is described. This method, which relies on the mechanism of the cleavage reaction of intein-containing fusion proteins, can produce multi-milligram quantities of protein C-terminal thiocarboxylate quickly and inexpensively. The utility of this method for protein semisynthesis and implications for studies on the biosynthesis of thiamin are discussed.

Electrophoresis, Polyacrylamide Gel↗

Comparison of algorithms and databases for matching unknown mass spectra.

The most used algorithms for the identification of electron-ionization mass spectra are INCOS and probability based matching (PBM). For unknown spectra of high purity, approximately 75% of rank 1 answers are correct for both algorithms, matched against the National Institute of Standards and Technology 62,235 spectrum database. With matching criteria that retrieve 50% of the possible correct answers from the Wiley 228,998 spectrum database, 54% of the PBM and 42% of the INCOS answers are correct; for 85% purity unknowns, 48% and 27% are correct. For an unknown spectrum of two compounds, neither was reported in the first three INCOS answers; eight of the first ten PBM answers identify both components.

Algorithms↗

Two-dimensional mass spectrometry of biomolecules at the subfemtomole level.

Multiple dimensions of unique molecular structure information can now be obtained from proteins and DNA using mass spectrometry. Less than 10(-16) mol of the active major histocompatibility complex signaling peptide in a mixture of thousands can be identified. For large proteins (> 40 kDa), the high resolving power (> 10(5) and 10(-17) mol sensitivity of Fourier-transform mass spectrometry provide exact molecular weight values (+/- 1 or 2 Da) for mixture components, indicating error or modifications compared with the predicted DNA sequence. Selecting a specific molecular species, its two-dimensional spectrum indicates the part of the molecule that is modified; a three-dimensional spectrum of that fragment further isolates the modification site.

Alkyl and Aryl Transferases↗

Identification of modification sites in large biomolecules by stable isotope labeling and tandem high resolution mass spectrometry. The active site nucleophile of thiaminase I.

A widely used procedure for site localization of covalent protein modifications involves proteolysis, partial chromatographic separation of the resulting complex mixture, and tandem mass spectrometry (MS/MS) to identify peptides whose molecular weight (Mr) has been increased appropriately by the modification. As found previously for MS of small molecules, this study shows that protein fragment identification can be greatly simplified by labeling the modification with stable isotopes. Further, the high resolution capabilities of Fourier transform MS make possible the direct identification of CH3/CD3-labeled peptides without chromatographic separation. Although separate Asp-N, Lys-C, and alpha-chymotrypsin digests of thiaminase I (42 kDa) yielded as many as 70 peptides, FTMS identification of the labeled peptide localized the modification site of a mechanism-based inhibitor to Arg101-Lys121, Asp90-Gly122, and Gly107-Tyr119, respectively. The measured mass difference values of the two labels agreed with that expected for CH3/CD3, 3.019 Da, with a standard deviation of 0.005 Da, providing persuasive identity verification. MS/MS fragmentation narrowed the site to Pro109-Phe118 and also caused loss of the derivative with a sulfur atom, uniquely identifying Cys113 as the thiaminase I active-site nucleophile among the 379 amino acids.

Alkyl and Aryl Transferases↗

Attomole protein characterization by capillary electrophoresis-mass spectrometry.

Electrospray ionization with an ultralow flow rate (</=4 nanoliters per minute) was used to directly couple capillary electrophoresis with tandem mass spectrometry for the analysis and identification of biomolecules in mixtures. A Fourier transform mass spectrometer provided full spectra (>30 kilodaltons) at a resolving power of approximately 60,000 for injections of 0.7 x 10(-18) to 3 x 10(-18) mole of 8- to 29-kilodalton proteins with errors of <1 dalton in molecular mass. Using a crude isolate from human blood, a value of 28,780.6 daltons (calculated, 28,780.4 daltons) was measured for carbonic anhydrase, representing 1 percent by weight of the protein in a single red blood cell. Dissociation of molecular ions from 9 x 10(-18) mole of carbonic anhydrase gave nine sequence-specific fragment ions, more data than required for unique retrieval of this enzyme from the protein database.

Animals↗

Sequence tag identification of intact proteins by matching tanden mass spectral data against sequence data bases.

Molecular and fragment ion data of intact 8- to 43-kDa proteins from electrospray Fourier-transform tandem mass spectrometry are matched against the corresponding data in sequence data bases. Extending the sequence tag concept of Mann and Wilm for matching peptides, a partial amino acid sequence in the unknown is first identified from the mass differences of a series of fragment ions, and the mass position of this sequence is defined from molecular weight and the fragment ion masses. For three studied proteins, a single sequence tag retrieved only the correct protein from the data base; a fourth protein required the input of two sequence tags. However, three of the data base proteins differed by having an extra methionine or by missing an acetyl or heme substitution. The positions of these modifications in the protein examined were greatly restricted by the mass differences of its molecular and fragment ions versus those of the data base. To characterize the primary structure of an unknown represented in the data base, this method is fast and specific and does not require prior enzymatic or chemical degradation.

Amino Acid Sequence↗

Mechanistic studies on thiaminase I. Overexpression and identification of the active site nucleophile.

Thiaminase I (EC 2.5.1.2) catalyzes the replacement of the thiazole moiety of thiamin with a wide variety of nucleophiles. Here we report the sequencing of a thiaminase I clone from Bacillus thiaminolyticus, the overexpression of the cloned gene in Escherichia coli, and the purification and characterization of the enzyme. Recombinant thiaminase I functions as a monomer with a Km for thiamin of 3.7 +/- 0.6 microM and a kcat of 34 s-1. Electrospray ionization Fourier-transform mass spectrometry identified a single sequencing error and demonstrated heterogeneity, finding molecular weights of 42,127, 42,198, and 42,255 due to added Ala and Gly-Ala at the amino terminus. Similar analysis of the 4-amino-2-methyl-6-chloropyrimidine inactivated enzyme indicated that the active site nucleophile involved in catalysis of the substitution reaction is located between Pro79 and Thr177. Subsequent cysteine-specific labeling and site-directed mutagenesis identified Cys113 as the active site nucleophile.

Alkyl and Aryl Transferases↗

Isotopic assignment in large-molecule mass spectra by fragmentation of a selected isotopic peak.

For large ( > 5 kDa) ionic species, Fourier transform ion cyclotron resonance instruments yield by far the highest mass accuracy. However, this can be compromised by misassignment of the isotopic content based on predicted natural abundances of the isotopic peaks. As an alternative method independent of natural abundance variations, high-resolution isolation and dissociation of a single isotopic peak yields a distribution of isotopic peak abundances characteristic of the isotopic content of the precursor peak. Accuracy is enhanced if the precursor peak is abundant and of minimum heavy isotope content, and if the product species is abundant and of intermediate mass. In addition, such spectra of the highest mass products are useful for identifying complementary product pairs, a key step in sequencing proteins and nucleotides.

Amino Acid Sequence↗

Broadband quadrupolar axialization of large multiply charged ions to enhance measurement and minimize conformational restrictions.

For high-resolution Fourier transform mass spectrometry of electrosprayed proteins, the signal-to-noise ratio of measuring nozzle-skimmer fragment ions can be improved substantially by their broadband quadrupolar axialization (QA), even without increasing their concentration in the ion cyclotron resonance cell. Axialization of the product ions makes possible larger, more concentric ion orbits for measurements. QA allowed the identification of new sequence-indicative product ions from a 29 kDa protein. However, QA of large molecular ions gives little increase in signal, consistent with original trapping near the cell axis. By recentering of ions undergoing ion-molecule reactions, these can be carried out at much higher kinetic energy and pressures; for cytochrome c this increases the achievable H-D exchange by 40%, corresponding to exchange at all the active sites of its completely denatured conformer.

Carbonic Anhydrases↗

Sampling error in small-bore sheathless capillary electrophoresis/electrospray-ionization mass spectrometry.

Two previously unreported sources of systematic error in electrokinetic injection caused by induced (hydrodynamic) flow in sheathless capillary electrophoresis/electrospray have been characterized for an interface constructed from 5 microns i.d. capillary column(s) with a 2-5 microns i.d. electrospray tip(s). The tip of a sheathless interface is usually exposed to the atmosphere, resulting in evaporation of buffer solvent and inducing flow inside the column; such flow can cause a significant underestimation of injection size for quantitative electrokinetic sampling by as much as 50%. This bias can be eliminated during the injection process by temporarily immersing the tip in buffer solvent. The second source of hydrodynamic flow results from the electrostatic pull exerted by the electrospray process on the buffer, reducing migration times. Reduction in migration times causes an overestimation of sampling volume if there are no electrospray processes during the sampling event. The magnitude of this effect is a complex function of electrophoretic and electrospray parameters and has been measured to be as high as 15% for 5 microns i.d. capillaries. The possible deterioration of electrophoretic resolution caused by these processes is not yet clarified.

Animals↗

Direct sequence data from heterogeneous creatine kinase (43 kDa) by high-resolution tandem mass spectrometry.

Isoelectric focusing separation of recombinant rabbit muscle creatine kinase (CK) and its 282Cys-->282Ser mutant shows the presence of three and two isoforms, respectively, that exhibit equivalent enzymatic activity. Electrospray ionization coupled with Fourier-transform mass spectrometry (10(5) resolving power) of both CKs indicates that their major components are within +/- 2 Da of the M(r) value predicted from the cDNA sequences of these mixtures. Dissociation of (M + nH)n+ gives no evidence that the components of either CK are isomers; the masses of the 51 fragment ions correlate completely (+/- 1 Da) with the values predicted from the cDNA sequence and confirm the identities of 21 of the 380 amino acids and the 282Cys-->282Ser replacement in the mutant. The results are consistent with one or two steps of post-translational amidation/deamidation (NH2-->OH, 16 Da-->17 Da), each of which would produce only a 1 Da difference in M(r), with the fragment masses indicating that at least one modification occurs between residues 212 and 282.

Animals↗

Sequence verification of human creatine kinase (43 kDa) isozymes by high-resolution tandem mass spectrometry.

Amino acid sequencing by recombinant DNA technology, although dramatically useful, is subject to base reading errors, is indirect, and is insensitive to posttranslational processing. Mass spectrometry techniques can provide molecular weight data from even relatively large proteins for such cDNA sequences and can serve as a check of an enzyme's purity and sequence integrity. Multiply-charged ions from electrospray ionization can be dissociated to yield structural information by tandem mass spectrometry, providing a second method for gaining additional confidence in primary sequence confirmation. Here, accurate (+/- 1 Da) molecular weight and molecular ion dissociation information for human muscle and brain creatine kinases has been obtained by electrospray ionization coupled with Fourier-transform mass spectrometry to help distinguish which of several published amino acid sequences for both enzymes are correct. The results herein are consistent with one published sequence for each isozyme, and the heterogeneity indicated by isoelectric focusing due to 1-Da deamidation changes. This approach appears generally useful for detailed sequence verification of recombinant proteins.

Artifacts↗

Attomole-sensitivity electrospray source for large-molecule mass spectrometry.

Full mass spectra of high resolving power are obtained from 0.2 nL sample volumes of large (> 10 kDa) nucleotides and proteins using a new electrospray ionization (ESI) system combined with Fourier transform mass spectrometry. The ESI needles are fabricated by laser-heated pulling of fused-silica tubing (5-20 microns i.d.), followed by chemical etching and surface metalization. Total analyte loaded at the instrument of 8.6 fmol and 216 amol produces signal-to-noise ratios of 400:1 and 60:1, respectively, and resolving power of > 10(5) for full mass spectra, while the total amount of material consumed is approximately 150 and 10 amol, respectively.

Animals↗

Gas-phase folding and unfolding of cytochrome c cations.

Water is thought to play a dominant role in protein folding, yet gaseous multiply protonated proteins from which the water has been completely removed show hydrogen/deuterium (H/D) exchange behavior similar to that used to identify conformations in solution. Indicative of the gas-phase accessibility to D2O, multiply-charged (6+ to 17+) cytochrome c cations exchange at six (or more) distinct levels of 64 to 173 out of 198 exchangeable H atoms, with the 132 H level found at charge values 8+ to 17+. Infrared laser heating and fast collisions can apparently induce ions to unfold to exchange at a higher distinct level, while charge-stripping ions to lower charge values yields apparent folding as well as unfolding.

Animals↗