Lymphoid polyposis of the terminal ileum and colon: a source of clinical error.
A case of lymphoid polyposis of the terminal ileum is presented. The clinical errors arising from confusion of this disorder with adenomatous polyposis are discussed.
Biomedical subjects
Publications and source records attributed to F W LoGerfo.
A case of lymphoid polyposis of the terminal ileum is presented. The clinical errors arising from confusion of this disorder with adenomatous polyposis are discussed.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Prosthetic arterial graft surfaces are relatively thrombogenic and fail to heal with a cellular neointima. The goal of this study was to characterize the in vivo antithrombin properties of a novel Dacron surface with covalently linked recombinant hirudin (rHir) implanted in a canine thoracic aorta with high flow and shear rates. rHir was bound to a knitted Dacron patch using crosslinker-modified bovine serum albumin (BSA) as a basecoat protein. BSA was first reacted with the heterobifunctional crosslinker, sulfo-SMCC. This BSA-SMCC complex was then bound to the carboxylic acid groups of hydrolyzed Dacron patches using the carbodiimide crosslinker, 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride. Iodinated, Traut's-modified rHir (125I-rHir-SH) was then reacted with the Dacron-BSA-SMCC surface, thereby covalently binding 125I-rHir. Graft segments were washed and sonicated to remove any nonspecifically bound 125I-rHir. Dacron-BSA-SMCC-S-125I-rHir patches (n = 5) and control Dacron-BSA patches (n = 5) were implanted in series in the thoracic aortas of canines. These patches were exposed to nonheparinized, arterial blood flow for 2 hours. Patches were explanted and assessed for 125I-rHir loss. Antithrombin activity of explanted 1-cm2 patch segments was evaluated using a chromogenic assay with 1, 5, 10, 15 units of added thrombin. Light microscopy was performed to qualitatively examine the pseudointima. Two animals were excluded from the study owing to excessive bleeding through the knitted 125I-rHir patch. Comparison of preoperative and postoperative 125I-rHir gamma counts revealed an overall decrease of 20+/-5.4% over the period studied. Explanted 125I-rHir patch segments were able to inhibit 1, 5, and 7 NIHU of thrombin, demonstrating retained antithrombin activity. Gross and microscopic examination of the control and test Dacron surfaces showed marked differences. Dacron surfaces with covalently bound 125I-rHir had no gross thrombus and a thin pseudointima of platelets and plasma proteins. In contrast, the control patches had a thick pseudointima composed of fibrin-rich thrombus. rHir, covalently bound to Dacron patches, maintains its biologic activity as well as prevents thrombus formation on the graft surface. This novel antithrombin coating, by modifying the blood/ graft interface, may improve both short- and long-term patency in small-diameter prosthetic arterial grafts and has applications with respect to other implantable or indwelling biomaterials.
Development of a small diameter prosthetic vascular graft with surface based antithrombin properties should aid in maintaining early graft patency in small vessel reconstruction. The purpose of this study was to bind covalently a basecoat protein (canine serum albumin [CSAJ) and a potent antithrombin agent (recombinant hirudin [rHir]) to 4 mm inner diameter poly(carbonate urea) urethane grafts with reactive carboxylic acid groups (cPU). 125I-CSA was covalently bound to 1 cm length segments of cPU grafts using the carbodimide cross-linker, 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC). To bind 125I-rHir covalently, CSA was modified with the heterobifunctional cross-linker sulfosuccinimidyl 4-(N-maleimidomethyl) cyclohexane-1-carboxylate (sulfo-SMCC) before linkage to the cPU surface with EDC (cPU-CSA-SMCC). 125I-rHir was modified with Traut's reagent and reacted with the cPU-CSA-SMCC surface, covalently linking 125I-rHir to surface bound CSA. 125I-CSA binding to the cPU graft surface (34,235 ng/segment) was ninefold, sevenfold, and 10-fold greater than controls with nonspecifically bound 125I-CSA. Covalent linkage of 125I-rHir to the cPU-CSA-SMCC surface (9,974 ng/segment) was 172, 192, and 142-fold greater than controls with nonspecifically bound 125I-rHir. Surface antithrombin properties were characterized using a chromogenic assay to measure residual thrombin activity. Evaluation of surface antithrombin activity showed significantly greater 131I-thrombin inhibition and binding by the cPU surface with covalently bound 125I-rHir, as compared with controls. Release of 125I-rHir from the cPU surface was minimal as compared with controls. Therefore, rHir can be covalently linked to a novel small diameter polyurethane vascular graft surface while maintaining its potent antithrombin properties.
Infection is a major complication when using biomaterials such as polyurethane in the clinical setting. The purpose of this study was to develop a novel infection resistant polyurethane biomaterial using textile dyeing technology. This procedure results in incorporation of the antibiotic into the polymer, resulting in a slow, sustained release of antibiotic from the material over time, without the use of exogenous binder agents. Polycarbonate based urethanes were synthesized that contained either a non-ionic (bdPU) or anionic (cPU) chain extender within the polymer backbone and cast into films. The fluoroquinolone antibiotic ciprofloxacin (Cipro) was applied to bdPU and cPU using textile dyeing technology, with Cipro uptake determined by absorbance reduction of the "dyebath." These dyed bdPU/cPU samples were then evaluated for prolonged Cipro release and antimicrobial activity by means of spectrophotometric and zone of inhibition assays, respectively. Cipro release and antimicrobial activity by dyed cPU segments that were aggressively washed persisted over 9 days, compared with dyed bdPU and dipped cPU control segments that lasted < 24 hours. Dyed cPU segments, which remained in a static wash solution, maintained antimicrobial activity for 11 days (length of study), whereas controls again lost antimicrobial activity within 24 hours. Thus, application of Cipro to the cPU polymer by means of dyeing technology results in a slow sustained release of antibiotic with persistent bacteriocidal properties over extended periods of time.
Boundary layer separation in a plexiglass model carotid bifurcation was investigated in relation to the origin of atherosclerotic plaque clinically found in this region. Our model was comparable to a human carotid in both dimensions and geometry. Water flowed through the model at Reynolds numbers from 200 to 1200 under steady and pulsatile flow conditions, with outflow through the external and internal branches varied. The near-wall flow was visualized by slow injection of dye through ports machined in the model. Under steady flow at a physiological Reynolds number of 500 and a flow split at the bifurcation similar to that of a human carotid at rest, boundary layer separation was found to occur in a carotid sinus across from the external carotid origin, forming a shell of slowly moving fluid around the bifurcation. The rapidly moving mainstream impinged directly on the flow divider. The location of atherosclerotic plaque correlates best with the low shear region of separation and not with the region of high shear at the flow divider. Preliminary studies with pulsatile flow demonstrated little change from the steady flow results.
This is a study of the flow disturbance in a plastic model of an asymmetric vascular bifurcation. A sidearm was attached to the mainlimb at an angle of 15 degrees to the inlet flow axis. Water at steady flow was used and flow patterns were demonstrated by a dye injection technique. The proportion of inlet flow (Qi) exiting from the sidearm (Qs) was varied and flow patterns were recorded photographically. A laser Doppler anemometer (LDA) was used to measure near-wall velocity. At a physiologic Reynolds' number of 500, no flow disturbance occurred in the mainlimb when the sidearm was completely occluded. When the fraction of flow exiting from the sidearm (Qs/Qi) reached 0.19, a region of boundary layer separation developed along the wall of the mainlimb opposite the flow divider. This region of nearly static fluid spread circumferentially around the mainlimb as Qs/Qi increased. Near-wall velocity within the separation decreased and became negative when Qs/Qi = 0.31. When Qs/Qi reached 0.38, the separation enveloped the wall of the entire bifurcation with a shell of slowly moving fluid. At the same time, the rapidly moving mainstream impinged directly on the flow divider. There is a similarity between the region of separation seen in this model and the site of formation of atherosclerotic plaque at the carotid bifurcation. Separation may contribute to atherogenesis by creating a region of low wall shear at bifurcations.
Explore the source record for details and available documents.
This study shows that prosthetic arterial grafts stimulate platelets for as long as 1 year after implantation in a canine model. Carotid-to-distal aorta Dacron (DuPont, Wilmington, DE) grafts (0.8 x 50.0 cm) were tunneled subcutaneously over the right dorsal side, allowing for percutaneous arterial sampling. Thromboxane B2 (TxB2) levels were evaluated at the proximal anastomosis (w), 5.0 (x), 25.0 (y), and 50.0 (z) cm distal from w, and platelet counts and mean platelet volumes were monitored at sites w and z. TxB2 levels increased after blood entered the graft and progressively increased until the blood exited at the distal anastomosis. Platelet counts did not significantly change across the graft. Over time, systemic platelet counts decreased to approximately 50% of each dog's pregraft baseline levels and remained depressed over a 1 year period. Mean platelet volumes peaked 1-3 weeks after implant and remained greater than pregraft levels. Examination of the graft luminal surface showed a developed pseudointima characteristically similar to that which develops in mature human vascular grafts. These results suggest that healed vascular grafts in canines continue to stimulate platelet release of TxB2, reduce systemic platelet counts, and increase mean platelet volumes over 1 year. These data further suggest that platelets are stimulated by the graft and consumed.