Search PubMed⌕ Search

Biomedical subjects

F W Campbell

Publications and source records attributed to F W Campbell.

At least 37 records · Page 2Linked to original sources

Tolerance to visual defocus.

Low-resolution optical systems are more tolerant to defocus than are high-resolution systems. We wished to determine whether this principle applies to human vision. We used psychophysical methods to measure the effects of defocus in normal eyes under low-resolution conditions. Modulation transfer of sine-wave gratings was measured as a function of dioptric defocus at low and medium spatial frequencies. We defined the depth of focus at a given spatial frequency to be the dioptric range for which the modulation transfer exceeds 50% of its peak value. For dilated pupils, depth of focus increased from about 2.5 diopters (D) at 3.5 cycles/deg to about 17 D at 0.25 cycles/deg. From our results we predicted that tasks requiring only low spatial frequencies will be more tolerant to defocus than tasks requiring higher spatial frequencies. This prediction was confirmed in a letter-recognition experiment. The increasing tolerance to defocus at low spatial frequencies also implies that individuals with low acuity will be more tolerant to defocus than people with normal vision. We confirmed this prediction by measuring tolerance to defocus in 30 low-vision eyes.

Humans↗

The importance of eye movements in the analysis of simple patterns.

How important are eye movements to visual pattern analysis? Previous findings indicate that at least one visual task (counting) is seriously impaired without them. We asked whether a comparable limitation applies to pattern recognition. Subjects were presented with pairs of randomly generated arrays composed of black and white pixels. The subjects indicated whether the arrays were identical or differed by one pixel. In one experiment, they were instructed to use normal eye movements, in another they were required to fixate on a point between the arrays. When eye movements were permitted, subjects' performance showed evidence for a search in which the discrepant pixel was eventually found, given adequate inspection time. When fixation was required, search was less efficient and the discrepant pixel was sometimes not found, despite prolonged inspection time. These results were independent of target size over a wide range. Our findings indicate that eye movements play a crucial role in pattern analysis that is not related to resolution.

Eye Movements↗

Effect of Fresnel prism dispersion on contrast sensitivity function.

Fresnel prisms are often used in orthoptics for binocular anomalies and in low vision for visual field defects. These prisms are made of optical polyvinyl chloride (PVC) and this material increases chromatic dispersion and produces a loss of contrast. In this study, the effect of chromatic dispersion on contrast sensitivity is determined. Contrast thresholds over a wide range of spatial frequencies are obtained on a number of subjects with the use of Fresnel prisms ranging from 5 to 30 prism dioptres. As predicted there is a decrease in visual acuity and cut-off spatial frequency threshold as prism power increases. Similarly, a decrease in contrast sensitivity at high and medium spatial frequencies is recorded.

Form Perception↗

Vernier acuity: interactions between length effects and gaps when orientation cues are eliminated.

It is shown that Vernier acuity is nearly proportional to line length (in the range 5-20 arc min), provided that the orientation of the target is randomized from trial to trial and provided that no gap interrupts the line. The effect of a pair of gaps, one in each of the Vernier bars leads to the conclusion that line terminations dissect the target into independent parts prior to the visual analysis of shape and orientation cues, which are only assessed between such features.

Adult↗

The effect of the site of placement of temporary epicardial pacemakers on ventricular function in patients undergoing cardiac surgery.

Temporary epicardial pacing leads are routinely placed in patients after cardiac surgery, but the positioning of ventricular leads and the use of atrial leads is not uniform. We examined the effect of the epicardial pacing site on ventricular function in 18 patients undergoing coronary surgery. Pacing wires were sutured in the right atrium, left ventricular apex, right ventricular apex, and right ventricular outflow tract before cardiopulmonary bypass. After atrial pacing, eight patients were ventricularly paced (group I) and 10 were atrioventricular (AV) sequentially (PR = 0.12 sec) paced (group II) at 100/minute from the three ventricular sites. Comparison of the groups showed that the addition of atrial activation during ventricular pacing resulted in higher cardiac indexes (2.54 +/- 0.61 vs 1.67 +/- 0.45 liters/min/m2;p less than .00005), higher systolic blood pressures (121 +/- 24 vs 89 +/- 26 mm Hg; p = .006), lower central venous pressures (5.5 +/- 3.2 vs 10.2 +/- 2.2 mm Hg; p = .048), and similar pulmonary arterial pressures (19.5 +/- 7.6/10.8 +/- 6.7 vs 24.7 +/- 3.5/15.4 +/- 3.4 mm Hg; p = NS). Cardiac index did not differ among group I patients during pacing from the different ventricular sites. In group II, cardiac index during pacing from the right ventricular apex was higher than during pacing from the right ventricular outflow tract or the left ventricular apex (2.62 +/- 0.57 vs 2.49 +/- 0.54 and 2.51 +/- 0.76 liters/min/m2, respectively; p = .03). Right ventricular outflow tract pacing resulted in higher cardiac indexes than left ventricular apical pacing in patients with stenosis of the left anterior descending coronary artery of 90% or more, while left ventricular apical pacing produced higher cardiac indexes in the absence of such lesions (p = .006).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

The recovery cycle of the pattern visual evoked potential in normal subjects and patients with multiple sclerosis.

The recovery cycle of amplitude and latency of the P100 of the chequerboard pattern reversal visual evoked response was studied in 16 normal subjects and 20 patients with multiple sclerosis. There was no clear-cut pattern of recovery with respect to amplitude but at interstimulus intervals of less than 40 msec the latency of the test response P100 tended to be significantly delayed, the magnitude of this delay being virtually constant at intervals of 20 msec or less. Only 8 of 40 eyes from the 20 multiple sclerosis patients showed a pattern of recovery of latency significantly different from the normal subjects. Possible mechanisms for these observations are discussed with particular reference to current concepts of the pathophysiology of multiple sclerosis.

Electroencephalography↗

Why do we measure contrast sensitivity?

The fundamental advantage of measuring the contrast sensitivity of the eye using sinusoidal gratings is that it gives a more complete description of its functional range. Such measurements increase our understanding of how we perceive events in the visual world. The technique can also be applied to other animals whose visual system is matched to a different visual environment. Moreover, single neurones can be measured and compared with psychophysical results. In recent years it has also become possible to investigate abnormal vision using clinical material.

Amblyopia↗

The visual display terminal issue: a consideration of its physiological, psychological and clinical background.

The publicity which has been given to Visual Display Terminals (VDTs) in recent years has been prompted by initial complaints from operators of visual and postural discomfort. The interest resulting from these complaints has led to much work being carried out on what appeared to be a potentially large problem. This work has precipitated recommendations and specifications from many quarters which in many cases are overcritical and rigid and do not take into account the great flexibility of the visual system and the need for mobility to maintain postural comfort. In this paper the VDT issue is considered with reference to: the known physiology of the visual and postural mechanisms; the psychological factors such as fatigue, boredom, stress and performance of operators; and the clinical aspects of ocular comfort.

Color↗

The discriminability of spatial phase relationships in amblyopia.

Previous work has shown that anomalies in the contrast sensitivity functions of amblyopes are often insufficient to explain the degree of visual deficit in more complex tasks. Our stimuli were compound gratings composed of a fundamental and its third harmonic, added in either square-wave or triangle-wave phase. At medium to high spatial frequencies we find that many amblyopes, unlike normal observers, are unable to distinguish between such gratings which have identical power spectra, but different phase spectra. In this frequency range they can, however, easily distinguish between a compound grating and its fundamental component alone. It seems that in amblyopia visual processing occurs over a more truncated frequency range than is implied by detection experiments. Various explanations of this observation are considered.

Adolescent↗

A demonstration of the visual importance and flexibility of spatial-frequency amplitude and phase.

To establish how little information the human visual system requires for recognition, common objects were digitally manipulated in the Fourier domain. The results demonstrate that it is not only possible, but also quite efficient, for a (biological) visual system to exist with very few phase relationships among the component spatial frequencies of the (retinal) image. A visual example is then presented which illustrates how certain phase relationships can hinder, or completely eliminate, the recognition of visual scenes.

Densitometry↗

Analysis and restitution of visual function in a case of cerebral amblyopia.

In a patient suffering from a severe bilateral dysfunction in both occipital and parietal areas we have found: (1) A loss of contrast-sensitivity, being strongest in the range of spatial frequencies where the normal eye is most sensitive; (2) Virtually normal grating resolution, a severe loss in letter acuity (about 15-fold), and a very strong loss in vernier acuity (about 100-fold); (3) Rapid partial recovery of contrast sensitivity due to stimulation; (4) Slow partial recovery of letter acuity due to CAM rotating grating treatment; (5) No improvement of a 10-fold temporal retardation in the speed of reading. Evidence is presented that the residual impairment of vision depends upon improper synthesis of spatial frequency components originating from a heavy loss in processing speed and abnormally long store duration for high spatial frequency information.

Adult↗

The physics of visual perception.

By measuring the contrast threshold for gratings of different waveform and spatial frequency, Campbell & Robson suggested in 1968 that there may be 'channels' tuned to different spatial frequencies. By using the technique of adapting to a high contrast grating, it was possible to measure the band-pass characteristics of these channels. Similar techniques were used to establish the orientational tuning of the channels. Reasons are put forward why it is advantageous to organize the visual system in this manner.

Form Perception↗