Search PubMed⌕ Search

Biomedical subjects

F U Niethard

Publications and source records attributed to F U Niethard.

At least 19 recordsLinked to original sources

Anatomical and biomechanical investigations of the iliotibial tract.

Divergent descriptions of the anatomic location and biomechanical function of the iliotibial tract (IT) can be found in the literature. This study attempted to obtain exact data regarding the anatomic course and material characteristics including the biomechanical properties of this structure. The following were its aims: (1) anatomical investigations of the IT; (2) mechanical properties of the IT; (3) femoral head centralizing force of the IT and subligamentous forces in the height of the greater trochanter in different joint positions by using a custom-made measuring prosthesis and a subligamentous positioned sensor; (4) construction of a finite element model of the proximal femur including the IT and measuring the femoral neck angle under variation. The hip joints and IT in a total of 18 unfixed corpses were evaluated. We studied the anatomic relationship to surrounding structures, as well as the material properties with the help of tensile strength testing utilizing an uniaxial apparatus. During the test, a load-displacement curve was registered, documenting the maximum load and deformation of the IT. To measure the subligamentous pressure at the height of the greater trochanter, a custom-made sensor with a power-recording instrument was constructed. Furthermore, an altered hip prosthesis with a pressure gauge at the height of the femoral neck was used to measure the forces which are directed at the acetabulum. The investigations were done in neutral-0 position and ab/adduction of the hip joint of the unfixed corpse. In addition, we varied the femoral neck angle between 115 degrees and 155 degrees in 5 degrees steps. To confirm the subligamentous forces, we did the same measurements intraoperatively at the height of the greater trochanter before and after hip joint replacement in 12 patients. We constructed a finite element model of the proximal femur and considering the IT. The acquisition of the data was done at physiological (128 degrees), varus (115 degrees), and valgus (155 degrees) femoral neck angles. The influencing forces of the IT at the height of the greater trochanter and the forces at the femoral head or the acetabulum could be measured. Our anatomical investigations revealed a splitting of the IT into a superficial and a deep portion, which covers the tensor fasciae latae. The tensor fasciae latae has an insertion on the IT. The IT continues down the femur, passing over the greater trochanter without developing an actual fixation to the bone. Part of the insertion of the gluteus maximus radiates into the IT. The IT passes over the vastus lateralis and inserts at the infracondylar tubercle of the tibia or Gerdy's tubercle, at the head of the fibula, as well as at the lateral intermuscular septum. Portions also insert on the transverse and longitudinal retinaculum of the patella. Concerning the material properties of the IT, we found a structural stiffness of 17 N/mm extension on average (D = 17 N/mm). The subligamentous measurements at the height of the greater trochanter in the unfixed corpse and intraoperatively during hip joint replacement showed an increase of the forces during adduction and a decrease during abduction of the hip joint. We found thereby a maximum increase up to 106 N with 40 degrees adduction. Concerning the femoral neck angle, we can state that valgus leads to lower subligamentous forces and varus to higher subligamentous forces. The forces directed at the acetabulum, which were measured by the prosthesis with a sensor along the femoral neck, showed a decrease with varus angles and an increase with valgus angles. The highest force of 624 N was measured with 40 degrees adduction and an angle of 155 degrees. The finite element model of the proximal femur showed a sole hip joint-centralizing force of the IT of 655 N with a femoral neck angle of 128 degrees after subtraction of the gluteal muscle force and the body weight. At 115 degrees, we found an increase up to 997 N and a decrease to 438 N at 155 degrees. Concerning the resulting forces in the acetabulum, we found opposite forces in comparison with the force of the IT at the height of the greater trochanter: at 115 degrees, a femoral head-centralizing force of 1601 N; at 128 degrees, 2360 N; and at 155 degrees, 2422 N. By our investigations, we can approximately prove the hip joint-centralizing force of the IT. By variation of the femoral neck angle and the position of the hip joint, we can predict the subligamentous force of the IT and the resulting force at the femoral head or at the acetabulum. The intraoperative measurement of the subligamentous forces of the IT is a good monitoring mechanism for the persistent hip-centralizing function of the IT in the course of hip joint replacement. The surgeon has the opportunity to check the stability of the hip joint after replacement. The finite element model gives the opportunity to check the divergent relative strength by variation of the femoral neck angle and the tension of the IT. In this way, the changes in the forces induced by a displacement osteotomy could be estimated preoperatively.

Aged↗

Patellar hypertension syndrome in adolescence: a three-year follow up.

INTRODUCTION: Anterior knee pain is one of the major causes of knee pain in an adolescent population. It has been suggested that raised intraosseous pressure may play an important role in the development of anterior knee pain in the young patient. MATERIAL AND METHODS: A prospective clinical multicentre study with 27 adolescent patients presenting with anterior knee pain was performed. After failure to respond to conservative treatment, all patients agreed to undergo minimally invasive intraosseous pressure measurements in local anaesthesia. All 27 patients demonstrated a positive "pain provocation test" as a response to increased intrapatellar pressure and were decompressed with a new intraosseous drilling technique. RESULTS: The repeat intraosseous pressure measurement in 27 patients 1 year postoperatively revealed a significant reduction from 43.3+/-13.4 preoperatively to 24.1+/-4.2 mmHg (p<0.001). The pain relief was documented in the form of a reduced VAS from 7.6+/-1.4 to 2.1+/-1.1 cm after 3 years (p<0.001). CONCLUSION: Patients with anterior knee pain and a positive "pain provocation test" were diagnosed as suffering from a hypertension syndrome of the patella. We conclude that simple extraarticular patellar decompression may offer a valuable new form of treatment in this select group of adolescent patients with anterior knee pain.

Arthralgia↗

[Nonsurgical treatment of congenital dysplasia and dislocation of the hip].

Despite general ultrasound screening of the newborn,congenital dysplasia and dislocation of the hip are still among the most common congenital skeletal diseases.A differentiated and stage-adjusted therapy must be the aim because inadequate therapy can lead to necrosis of the femoral head or a residual dysplasia that both require further treatment. Now as before a correct and early diagnosis is absolutely necessary for the treatment of dysplasia of the hip.A once treated hip should be observed until completion of growth.

Child, Preschool↗

Fluordeoxyglucose positron emission tomography detection of inflammatory reactions due to polyethylene wear in total hip arthroplasty.

A patient experienced chronic pain 8 years after total hip arthroplasty. Radiology and bone scanning showed no signs of aseptic loosening, but fluorine-18 fluorodeoxyglucose positron-emission tomography ((18)F-FDG-PET) showed intensive glucose metabolism in the joint capsule and around the prosthesis neck. The surgical intervention revealed soft tissue reaction in this area. Histologic examination showed a granulomatous foreign body reaction against polyethylene debris particles. Infection and rheumatoid arthritis could be excluded clinically, histologically, microbiologically, and with the bone scan. Therefore, FDG-PET detected inflammatory reaction caused by polyethylene wear in total hip arthroplasty and allowed clinicians to decide on interventions, including removal of granulomatous tissue and the replacement of worn artificial joint components to prevent aseptic loosening.

Fluorodeoxyglucose F18↗

[A new coating method for cemented femur shaft implants--biocompatibility, stability during sterlization and adhesive strength].

The main cause of aseptic loosening of cemented stems in total hip arthroplasty is the hydrolytic degradation of the metal-cement interface. In order to prevent this debonding a new multilayer method of coating the implant surface involving the use of a silica-/silane technique to create a durable adhesive bond between metal stem and bone cement has been developed. The biocompatibility of all the elements of the multilayer system was confirmed using a human osteoblast cell culture test. For sterilization purposes, gamma irradiation with a 25 kGy effective dose proved to be the method of choice. The proven biocompatibility and successful sterilization of the coated implants are the main prerequisites for in-vivo usage. On the technical side, the bonding effectiveness of the multilayer coating system was demonstrated by the tensile test, which revealed a significant improvement in the adhesive strength of the cement-metal bond under prolonged moist conditions similar to those met with in the human body.

Bone Cements↗

[Analysis of (18)F-FDG uptake patterns in PET for diagnosis of septic and aseptic loosening after total hip arthroplasty].

AIM: Identification of typical patterns for fluorodeoxy-glucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (ace-tabular and/or femoral component) and prosthetic infection. METHODS: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. RESULTS: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral femoral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. CONCLUSION: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population.

Aged↗

Prognostic significance of the Nasca classification for the long-term course of congenital scoliosis.

AIM: The aim of our investigations was to answer the question of whether the radiologic classification according to the investigations of Nasca has prognostic relevance for congenital scoliosis. Based on our results, a therapeutic concept was given. PATIENTS AND METHODS: Radiographs of 49 patients with a congenital scoliosis were classified according to Nasca. The progression of the malformation was analyzed by regarding the changes over a period of 8.3 years on average. RESULTS: Of the analyzed patients with congenital scoliosis, 73% showed a mean progression rate of 1.8 degrees per year. The most advanced progress of the Cobb angle per year was seen in patients with unilateral unsegmented bars with or without additional hemivertebrae (type 4 according to the Nasca classification) and patients with wedge-formed vertebrae (type 2a according to the Nasca classification). The presence of unilateral bars and the location of the hemivertebra or hemivertebrae (type 4) and wedge-formed vertebrae (type 2a) are the major determinants of deformity. Within the scope of our investigations, the following three factors were seen as deleterious when combined: thoracolumbal and long-distance scoliosis, female gender, and prepubertal growth period. CONCLUSION: From our analysis of 49 patients, we can propose the following therapeutic system for congenital scoliosis. Sole treatment with physiotherapy should only be recommended with congenital scoliosis curves ranging from 0 degrees to 20 degrees according to the Cobb method. With a Cobb angle smaller than 40 degrees and some flexibility remaining in the spine, the congenital scoliosis should be treated additionally with corrective casts. For congenital scoliosis with a Cobb angle of more than 50 degrees, as well as for congenital scoliosis with a poor prognosis (for example unilateral bars), a spondylodesis of the spine should be done before reaching the age of 5 years.

Casts, Surgical↗

Improvement of the long-term adhesive strength between metal stem and polymethylmethacrylate bone cement by a silica/silane interlayer system.

A loss of adhesive strength between metal stem and bone cement is clinically found to be a serious problem in total hip arthroplasty and causes many operative revisions. The objective of this study was to improve the long-term adhesive strength at this interface. A new silica/silane interlayer coating system is introduced. The layers are designed to bond the metal stem surface to the polymethylmethacrylate bone cement marginally leakage free. In vitro tensile tests were performed on specimens of TiAl6V4 and CoCrMo that were cemented by pairs with different bone cements with and without the new coating system. The specimens were stored in isotonic saline solution up to 150 days. The adhesive strength decreased about 75% within 30 days of storage on specimens of both metal alloys that were conventionally cemented without the new interlayer system. With the new coating, the high initial adhesive strength (40-50 MPa) could be stabilized for TiAl6V4 over 150 days. For the same 150-day storage period, the adhesive strength of the coated CoCrMo alloy still decreased but the decrease was only half that experienced by the uncoated CoCrMo. The loss of adhesive strength on CoCrMo specimens could be reduced if the metal surface was activated by a plasma treatment. The new coating interface system could help to considerably reduce revision operations caused by debonding effects at the interface metal/polymethylmethacrylate bone cement.

Adhesiveness↗

[Orthopedic/visceral surgery cooperation in pelvic tumors].

Co-operation between orthopaedic surgeons and visceral surgeons is required in the treatment of malignant tumours of the pelvis when the rectum or the iliac vessels are infiltrated. Such infiltration can be expected in malignancies which originate in the sacrum. Most frequently, chordomas are found in this area, that should be resected with wide surgical margins even in advanced tumours to reduce the risk of local recurrence. When resecting the sacrum, the stability of the vertebral column and the pelvis is compromised only at levels above S2. After unilateral resection of the sacral nerve roots S2-S5, there are only minor impairments of the anal and bladder sphincter control. In the case of tumour infiltration of the rectum and simultaneous resection of the sacral nerve roots, abdominoperineal extirpation of the rectum is required even when a safe margin is left between the tumour and the anal sphincter. In different studies, the 5-year survival in patients with a malignancy of the sacrum varies between 52% and 84%. In view of the rarity of these tumours, treatment should be performed only at specialized centers where co-operation is ensured.

Bone Neoplasms↗

Correction of kyphotic deformity before and after transection of the anterior longitudinal ligament--a cadaver study.

With a custom-made measuring unit, two separate experiments, involving six and five cadaveric torsos with intact rib cages and sternums, respectively, were carried out to determine the effect of the transection of the anterior longitudinal ligament with and without osteodiscectomy and its influence on the thoracic kyphosis. The open or thoracoscopically assisted anterior release, as part of the operative treatment of scoliosis or kyphosis, usually consists of a transection of the anterior longitudinal ligament (ALL) and an additional discectomy. A complete osteodiscectomy, however, is not always possible with a minimally invasive approach. As part of our biomechanical research, we attempted to quantify the amount of correction achievable with a defined force prior to and following the isolated transection of the anterior longitudinal ligament. The aim of the study was to clarify whether or not an isolated transection of the anterior longitudinal ligament is sufficient to obtain an adequate anterior release of the spine. In the surgical treatment of kyphotic deformities, anterior release of the spine is performed in the form of a transection of the ALL and discectomy. Recently, video-assisted thoracic surgery has become increasingly popular in spine surgery. As part of this change in surgical technique, the question has arisen as to what extent an isolated transection of the ALL provides an adequate release of the thoracic spine. Eleven human spines were retrieved from fresh cadavers, dissected, and attached to a specially constructed apparatus. The spine was attached to the construct at the twelfth vertebral body. C6 and C7 were fixed in synthetic resin. We installed the instruments in such a manner as to reproducibly apply a torsional moment of 10 Nm to the spine. Motion was only permitted in the sagittal plane. Segmental transections of the ALL were carried out from T3 to T7. For comparison, the sagittal Cobb angle was also documented following an anterior release combined with an osteodiscectomy. With the isolated transection of the ALL, an average correction of the sagittal Cobb angle of 4 degrees in each functional spinal motion segment was recorded. In comparison, the additional osteodiscectomy led to a further average increase of only 2 degrees per level. The measurements performed on human cadavers showed that the isolated transection of the ALL leads to a sufficient anterior release of the thoracic spine, allowing a correction of the kyphotic deformity. The release with a concomitant osteodiscectomy represents a more time-consuming and more invasive procedure resulting in only a slightly greater amelioration of the sagittal Cobb angle, while being associated with a greater patient morbidity.

Aged↗

[Stretched polyethylene (UHMWPE)--a new substance modification for minimizing wear in artificial knee joint replacement].

Polyethylene wear is a major cause of aseptic loosening of knee endoprostheses. With the aim of minimizing this mechanical wear, we stretch-modified the structure of polyethylene. From plates of UHMWPE, stretched PE samples were produced under defined conditions, and subsequently submitted to friction tests in a fluid environment (cycles 5 x 10(5), frequency 1.5 Hz, load 500 N, contact stress 10 MPa). After load testing, the stretched samples revealed a 70% reduced wear rate in comparison with non-stretched samples. Microscopic examination (light microscopy, scanning electron microscopy) showed abrasive scratches in all test samples, but only in the non-stretched specimens were signs of pitting found. Translating these results to unidirectional tractive rolling on the tibial plateau in the knee joint suggests that a significant reduction in polyethylene wear can be expected. However, further experimental investigations need to be carried out to confirm this highly promising possibility.

Elasticity↗

Madelung deformity: clinical features, therapy and results.

In a retrospective study, 31 patients with Madelung deformity were reviewed. They were treated at one institution during a period of 15 years. On first presentation, the mean age was 22.5 years with a range from 10 years to 64 years. Twenty-four patients (77%) were female. The main complaints were pain, limited range of motion, and objectionable appearance. A family history of Madelung deformity was present in four patients (13%). The diagnosis of Leri-Weill syndrome could not be confirmed in any case. There was no correlation between the clinical appearance and the extent of radiologic abnormality. Five patients (16%) were operated on because of permanent pain. On postoperative examination, only one patient revealed no restricted range of mobility and no pain, whereas the other four patients improved in terms of pain but showed only limited improvement of function. The vast majority of patients, however, required no surgical therapy.

Adolescent↗

Clonal chromosome abnormalities in enchondromas and chondrosarcomas.

We report cytogenetic findings in short-term cell cultures from five enchondromas and four chondrosarcomas. Clonal chromosome aberrations were found in one case of enchondroma, and in all cases of chondrosarcoma. The only enchondroma with nonrandom abnormalities had a reciprocal t(8;17)(q23;p13), and monosomies 9, 19, and/or 22. In contrast to the few karyotypic findings in one of five enchondromas, the four chondrosarcomas were commonly characterized by cytogenetic heterogeneity, with a tendency for increasing karyotypic complexity in higher grade tumors. Two cases, one grade III and one metastasizing grade II chondrosarcoma, revealed hypodiploid stem- and sidelines with loss of chromosomes 6, 10, 13, 14, and 22, as common chromosomal abnormalities, suggesting a distinct karyotypic pattern in a subset of biologically aggressive chondrosarcomas.

Adolescent↗

Diagnostic and therapeutic management of lumbar and thoracic spondylodiscitis--an evaluation of 59 cases.

Fifty-nine patients with spondylodiscitis (SD) of the thoracic and/or lumbar spine were followed-up clinically and radiologically [X-ray, computed tomography (CT), magnetic resonance imaging (MRI)] over a mean time of 2.2 years (1-6.5 years). All patients without abscess formation (n = 35) were treated conservatively. Out of the group with abscess formation (n = 24) 6 patients were also treated conservatively, 11 were drained under CT control and 7 were operated. At time of diagnosis, "signs of florid inflammation" were seen in 60% of the roentgenograms, in 93% of the CTs and in all of the MRls. The sensitivity to differentiate between SD with and without abscess formation was 85% by MRI and 69% by CT. "Signs of regressive inflammation" and "signs of increasing osseous consolidation", essential facts for starting remobilization, could first be seen using CT 6 weeks after onset of therapy. Using MRI these signs were seen with a considerable delay at 12 weeks. Clinically, only 3 of the 59 analyzed patients developed recurrent SD. In conclusion, MRI is the radiological method of choice for establishing the diagnosis of SD, in particular with regard to differentiating between cases with and without abscess formations. In contrast, CT is superior for performing success control after treatment. Therapeutically, conservative, minimal-invasive and operative procedures are not rival but rather complementary.

Abscess↗