Search PubMed⌕ Search

Biomedical subjects

F T Hambrecht

Publications and source records attributed to F T Hambrecht.

At least 19 recordsLinked to original sources

Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex.

The feasibility of producing a visual prosthesis for the blind using intracortical microstimulation (ICMS) of the visual cortex was studied in a 42-year-old woman who had been totally blind for 22 years secondary to glaucoma. Thirty-eight microelectrodes were implanted in the right visual cortex, near the occipital pole, for a period of 4 months. Percepts reported as small spots of light, called phosphenes, were produced with 34 of the 38 implanted microelectrodes. Threshold currents for phosphene generation with trains of biphasic pulses were as low as 1.9 microA, and most of the microelectrodes had thresholds below 25 microA. Phosphene brightness could be modified with stimulus amplitude, frequency and pulse duration. Repeated stimulation over a period of minutes produced a gradual decrease in phosphene brightness. Phosphenes did not flicker. The apparent size of phosphenes ranged from a "pin-point' to a "nickel' (20 mm diameter coin) held at arm's length. Phosphene size usually decreased as stimulation current was increased but increased slightly as the train length (TL) was increased. At levels of stimulation near threshold, the phosphenes were often reported to have colours. As the stimulation level was increased, the phosphenes generally became white, greyish or yellowish. Individual phosphenes appeared at different distances from the subject. When two phosphenes were simultaneously generated, the apparent distances of the individual phosphenes sometimes changed to make them appear to be at about the same distance. When three or more phosphenes were simultaneously generated, they became coplanar. Except for rare occasions, phosphenes extinguished rapidly at the termination of the stimulation train. When stimulation TLs were increased beyond 1 s, phosphenes usually disappeared before the end of the train. The duration of phosphene perception could be increased by interrupting a long stimulation train with brief pauses in stimulation. Intracortical microelectrodes spaced 500 microns apart generated separate phosphenes, but microelectrodes spaced 250 microns typically did not. This two-point resolution was about five times closer than has typically been achieved with surface stimulation. With some individual microelectrodes, a second closely spaced phosphene was sometimes produced by increasing the stimulation current. Phosphenes moved with eye movements. When up to six phosphenes were simultaneously elicited, they all moved with the same relative orientation during eye movements. All phosphenes were located in the left hemi-field with the majority above the horizontal meridian. There was a clustering of most of the phosphenes within a relatively small area of visual space. The potentially greater microelectrode density and lower power requirements of ICMS compared with surface stimulation appears encouraging for a visual prosthesis. However, further studies with blind subjects are required to optimize stimulation parameters and test complex image recognition before the feasibility of a visual prosthesis based on ICMS can be established.

Adult↗

Functional electrical stimulation: an overview.

The development of future neural prostheses involves much more than connecting commercially available stimulators to disabled individuals. Safe and effective operation of prostheses requires fundamental studies of the electrode-tissue interface. The electrochemistry of the interface must be controlled to prevent toxic byproducts. Histopathological studies of stimulated tissue are necessary to establish safe limits of stimulation and to determine mechanisms of neural damage when it does occur. Electrophysiological studies elucidate which neural pathways are excited and help in the design of more selective electrode arrays. Biomaterials are required that protect the implant from the hostile environment of the body. Presently available materials are being improved and totally new materials are being developed. One of the goals of neural prostheses developers is a nonhermetic packaging material that can be applied to miniature implants without appreciably increasing their size. The techniques used to make integrated circuits on silicone substrates are ideally suited to making ultraminiature electrodes with self-contained electronic signal processing. Both integrated circuit stimulating and recording electrodes are being designed and fabricated.

Biocompatible Materials↗

Criteria for selecting electrodes for electrical stimulation: theoretical and practical considerations.

Smaller, more charge-intensive electrodes are needed for "safe" stimulation of the nervous system. In this paper we review critical concepts and the state of the art in electrodes. Control of charge density and charge balance are essential to avoid tissue electrolysis. Chemical criteria for "safe" stimulation are reviewed ("safe" is equated with "chemically reversible"). An example of a safe, but generally impractical, charge-injection process is double-layer charging. The limit here is the onset of irreversible faradaic processes. More charge can be safely injected with so-called "capacitor" electrodes, such as porous intermixtures of Ta/Ta2O5. BaTiO3 has excellent dielectric properties and may provide a new generation of capacitor electrodes. Faradaic charge injection is usually partially irreversible since some of the products escape into the solution. With Pt, up to 400 muc/cm2 real area can be absorbed by faradaic reactions of surface-adsorbed species, but a small part is lost due to metal dissolution. The surface of "activated" Ir is covered with a multilayer hydrated oxide. Charge injection occurs via rapid valence change within this oxide. Little or no metal dissolution is observed, and gassing limits are not exceeded even under stringent conditions.

Electric Injuries↗

Neural prostheses.

Explore the source record for details and available documents.

Audiovisual Aids↗

Electrical stimulation of the brain. III. The neural damage model.

A major concern in the use of neural prostheses is whether electrical stimualtion can cause irreversible damage to neurons. The Neural Damage Model was devised to study the problem and to provide guidlines. The cerebral cortex of cats was stimulated continuously for 36 hours with balanced, biphasic waveforms. The charge per phase, charge density and current density were varied in 16 separate tests. Of these stimulus parameters the charge per phase was more closely correlatable with neuronal damage than charge density and current density. Furthermore, the findings in this study suggest that current flow is more important than electrochemical reactions in causing neural damage. Correlation between blood-brain barrier (BBB) breakdown and neuronal damage was valid only in the group of animals sacrificed immediately following stimulation. The BBB is restored within one month following electrical injury. Convulsive seizures occurred in all but one of the animals during electrical stimulation. A technique for localizing the electrode sites at autopsy and in the microscopic sections is described.

Animals↗