Accuracy of segmented MR velocity mapping to measure small vessel pulsatile flow in a phantom simulating cardiac motion.

The purpose of this study was to investigate the accuracy of conventional, segmented, and echo-shared MR velocity mapping sequences to measure pulsatile flow in small moving vessels using a phantom with simulated cardiac motion. The phantom moved either cyclically in-plane, through-plane, in- and through-plane, or was stationary. The mean error in average flow was -2% +/- 3% (mean +/- SD) for all sequences under all conditions, with or without background correction, as long as the region of interest (ROI) size was equal to the vessel cross-sectional size. Overestimation of flow as a result of an oversized ROI was less than 20%, and independent of field of view (FOV) and matrix, as long as the offset in angle between the imaging plane and flow direction was less than 10 degrees. Segmented velocity mapping sequences are surprisingly accurate in measuring average flow and render flow profiles in small moving vessels despite the blurring in the images due to vessel motion. J. Magn. Reson. Imaging 2001;13:722-728.

Blood Flow Velocity↗

Persistent high signal on diffusion-weighted MRI in the late stages of small cortical and lacunar ischaemic lesions.

Diffusion-weighted imaging (DWI) is very sensitive to early brain infarcts. However, the late stages have been insufficiently studied. Infarcts in small vessel disease are often multiple and of different ages, and differentiation between new and old lesions might be difficult. We have therefore studied the change with time in DWI of small (< 3 ml) ischaemic lesions. We imaged 21 patients with an acute lacunar syndrome and a lesion visible on early DWI. They all had three MRI examinations 12-58 h (early), 7-16 and 54-144 days after the onset of stroke; 10 patients with high DWI signal on the third examination had a fourth examination 12-28 months after the stroke. MRI was performed at 1.5 T, using echo-planar DWI with 7 b-values from 0 to 1200 x 10(6) s/m2 and conventional T2-weighted imaging. After 7-16 days 18 of 21 lesions gave high signal on DWI, and 12/16 measurable lesions had a decreased apparent diffusion coefficient (ADC). After 54-144 days ten lesions still gave high DWI signal and two still had an ADC below normal. On the fourth examination there was no remaining high DWI signal and all ADC were higher than normal.

Brain↗

Contrast-enhanced thoracic 3D-MR angiography in infants and children.

PURPOSE: To optimise breath-hold contrast-enhanced MR angiography (MRA) in infants and children with suspected congenital heart or thoracic vessel malformation. MATERIAL AND METHODS: Thirty-nine children (median age 1 year) were examined, using five different ultrafast MRA sequences with a TR between 3.2 and 5.0 ms and the contrast agent meglumine gadoterate. A test injection was used to determine contrast travel time. Different parameters for contrast injection were evaluated. Signal-to-noise ratio (SNR) measurements were performed and image quality and injection timing were evaluated. RESULTS: MRA was successful in all patients and image quality was considered very good in 52%. Adequate SNR was achieved with no significant differences between the MR sequences. SNR decreased only 25-30% between subsequent scans. The mean contrast dose was 0.23 mmol/kg. The mean scan time was 12.5 +/- 3.8 s; the shorter scan times made dynamic examinations possible with high temporal resolution. Highest spatial resolution was obtained with TR 4.6/5.0 sequences. CONCLUSION: A contrast dose of 0.2 mmol/kg b.w. is recommended with an injection rate of 0.5 to 1.2 ml/s, depending on patient size and scan time. The scan delay time should equal the contrast travel time for optimal vessel enhancement. In the future, contrast-enhanced MRA may be a potential alternative to angiocardiography in infants and children.

Adolescent↗

Perfusion-related parameters in intravoxel incoherent motion MR imaging compared with CBV and CBF measured by dynamic susceptibility-contrast MR technique.

OBJECTIVE: Perfusion-related parameters obtained by intravoxel incoherent motion (IVIM) MR imaging (MRI) were compared with cerebral blood volume and flow (CBV and CBF), retrieved by dynamic susceptibility-contrast (DSC) MRI. MATERIAL AND METHODS: Twenty-eight volunteers (average age 68.5 years) were investigated. Spin-echo echo-planar imaging with IVIM-encoding gradients was employed (36 different b values, 0-1200 s/mm2). The perfusion fraction and the pseudo-diffusion coefficient were calculated for regions in thalamus gray matter and frontal white matter, using asymptotic and full fitting. In DSC-MRI, a Gd-DTPA-BMA contrast-agent bolus was monitored using simultaneous-dual FLASH. Deconvolution of the measured tissue concentration-versus-time curve with an arterial input function from the carotid artery was applied, and maps of CBV and CBF were calculated. RESULTS: The correlation between the perfusion fraction and CBV was r=0.56 (p<0.0000006) using asymptotic fitting, and r=0.35 (p<0.0004) when full fitting was applied. Average CBF was 41.5 ml/(min 100 g), to be compared with the IVIM-based value of 63.6 ml/(min 100 g), obtained from the median value of the pseudo-diffusion coefficient in combination with assumptions about capillary network structure. CONCLUSION: The IVIM concept provided results that agreed reasonably with conventional CBV and CBF. The non-linear fitting to noisy signal data was problematic, in accordance with previously presented simulations.

Aged↗

Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques.

Regional cerebral blood flow (rCBF) was assessed using dynamic susceptibility-contrast MRI at 1.5 T. A simultaneous dual FLASH pulse sequence and Gd-DTPA-BMA (0.3 mmol/kg b.w.) were used for examination of 43 volunteers, measuring rCBF in frontal white matter (WM) and in gray matter in the thalamus (GM). Arterial input functions (AIFs) were registered 1) in the carotid artery and 2) in an artery within the GM/WM slice. The measured concentration-vs. -time curve was deconvolved with the AIF using both Fourier Transform (FT) and Singular Value Decomposition (SVD). Relative rCBF was given by the height of the deconvolved response curve. For each volunteer, eight different rCBF maps were calculated, representing different combinations of deconvolution techniques, AIFs, and filters. The average GM-WM rCBF ratios ranged from 2.0-2.2, depending on methodology. Absolute rCBF was 68 +/- 28 ml/(min 100 g) in GM and 35 +/- 13 ml/(min 100g) in WM (mean +/- SD, n = 39). GM-WM rCBF ratios obtained using SVD were 6-10% higher than corresponding ratios obtained using FT.

Adult↗

MR evaluation ex vivo and in vivo of a covered stent-graft for abdominal aortic aneurysms: ferromagnetism, heating, artifacts, and velocity mapping.

Magnetic resonance imaging (MRI) safety was evaluated at 1.5 T in a covered nickel titanium stent-graft (Vanguard) used for endovascular treatment of abdominal aortic aneurysms (AAAs). Imaging artifacts were assessed on MRI with contrast-enhanced (CE) three-dimensional (3D) MR angiography (MRA) and spiral computed tomography (CT) in 10 patients as well as ex vivo. Velocity mapping was performed in the suprarenal aorta and femoral arteries in 14 patients before and after stent-graft placement. For comparison it was also performed in six healthy volunteers. No ferromagnetism or heating was detected. Metal artifacts caused minimal image distortion on MRI/MRA. The artifacts disturbed image evaluation on CT at the graft bifurcation and graft limb junction. No significant differences in mean flow were found in patients before and after stent-graft placement. Our study indicates that MRI at 1.5 T may be performed safely in patients with the (Vanguard) stent-graft. MRI/MRA provides diagnostic image information. Velocity mapping is not included in our routine protocol.

Aortic Aneurysm, Abdominal↗

Absolute cerebral blood flow measured by dynamic susceptibility contrast MRI: a direct comparison with Xe-133 SPECT.

Absolute regional cerebral blood flow (CBF) was measured in ten healthy volunteers, using both dynamic susceptibility-contrast (DSC) magnetic resonance imaging (MRI) and Xe-133 SPECT within 4 h. After i.v. injection of Gd-DTPA-BMA (0.3 mmol/kg b.w.), the bolus was monitored with a Simultaneous Dual FLASH pulse sequence (1.5 s/image), providing one slice through brain tissue and a second slice through the carotid artery. Concentration C(t) is proportional to -(1/TE) ln[S(t)/S(0)] was related to CBF as C(t) = CBF [AIF(t) x R(t)], where AIF is the arterial input function and R(t) is the residue function. A singular-value-decomposition-based deconvolution technique was used for retrieval of R(t). Absolute CBF was given by Zierler's area-to-height relation and the central volume principle. For elimination of large vessels (ELV), all MRI-based CBF values exceeding 2.5 times the mean CBF value of the slice were excluded. A correction for partial-volume effects (CPVE) in the artery used for AIF monitoring was based on registration of signal in a phantom with tubes of various diameters (1.5-6.5 mm), providing an individual concentration correction factor applied to AIF data registered in vivo. In the Xe-133 SPECT investigation, 3,000-4,000 MBq of Xe-133 was administered intravenously, and CBF was calculated using the Kanno Lassen algorithm. When ELV and CPVE were applied, DSC-MRI showed average CBF values from the entire slice of 43 +/- 10 ml/(min 100 g) (small-artery AIF) and 48 +/- 17 ml/(min 100 g) (carotid-artery AIF) (mean +/- S.D., n = 10). The corresponding Xe-133-SPECT-based CBF was 33 +/- 6 ml/(min 100 g) (n = 10). The relationships of CBF(MRI) versus CBF(SPECT) showed good linear correlation (r = 0.74-0.83).

Aged↗

Vasodilatation with felodipine in chronic asymptomatic aortic regurgitation.

BACKGROUND: Afterload reduction decreases volume overload on the left ventricle and may thereby delay the need for valve replacement in chronic asymptomatic aortic regurgitation. The aims of this randomized double-blind, placebo-controlled trial were to examine short- and long-term hemodynamic effects of felodipine in chronic asymptomatic aortic regurgitation. METHODS: Sixteen patients were randomly assigned to an intravenous infusion of either felodipine 0. 3 mg or placebo followed by 3 months' treatment with felodipine 10 mg or placebo orally once daily. Magnetic resonance imaging was performed at baseline, immediately after intravenous treatment, and after 3 months of oral treatment. RESULTS: Intravenous felodipine caused a statistically significant reduction in the systemic vascular resistance from (mean +/- SD) 1160 +/- 400 to 970 +/- 320 dynes. s. cm(-5) (P <.05), in the regurgitant volume index from 1.5 +/- 0.8 to 1.3 +/- 0.8 L. min(-1). m(-2) (P <.05), and in the regurgitant fraction from 0.31 +/- 0.15 to 0.26 +/- 0.14 (P <.05). The forward cardiac output index increased significantly from 3.2 +/- 0.9 to 3.5 +/- 0.7 L. min(-1). m(-2) (P <.05). Three months of oral treatment with felodipine caused a corresponding but more pronounced decrease in systemic vascular resistance of 880 +/- 330 dynes. s. cm(-5) (P <.05), regurgitant volume index of 1.2 +/- 0.7 L. min(-1). m(-2) (P <.05), and regurgitant fraction 0.25 +/- 0.11 (P <.05), whereas the forward cardiac output index increased to 3.6 +/- 0.7 L. min(-1). m(-2) (P <.05). No significant changes were found in the placebo group. Left ventricular volumes and ejection fraction remained unaffected by treatment, but compared with the placebo group left ventricular myocardial mass decreased significantly from 137 +/- 24 to 132 +/- 21 g. m(-2) (P <.01). CONCLUSION: In chronic asymptomatic aortic regurgitation, felodipine causes beneficial hemodynamic effects that may postpone the need for valve replacement.

Adult↗

High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging.

Diffusion magnetic resonance imaging (MRI) was performed with a high-resolution segmented echo-planar imaging technique, which provided images with substantially less susceptibility artifacts than images obtained with single-shot echo-planar imaging (EPI). Diffusion imaging performed with any multishot pulse sequence is inherently sensitive to motion artifacts and in order to reduce motion artifacts, the presented method utilizes navigator echo phase corrections, performed after a one-dimensional Fourier transform along the frequency-encoding direction. Navigator echo phases were fitted to a straight line prior to phase correction to avoid errors from internal motion. In vivo imaging was performed using electro cardiographic (ECG) triggering. Apparent diffusion coefficient (ADC) maps were calculated on a pixel-by-pixel basis using up to seven diffusion sensitivities, ranging from b = 0 to 1129 x 10(6) s/m(2).

Adult↗

Clinical lacunar syndromes as predictors of lacunar infarcts. A comparison of acute clinical lacunar syndromes and findings on diffusion-weighted MRI.

OBJECTIVES: To evaluate if patients with acute lacunar syndromes have acute lacunar infarcts or other types of cerebral lesions on diffusion-weighted MRI. METHODS: Patients with acute lacunar syndromes underwent echo-planar diffusion MRI of the brain within 3 days after stroke onset. Localization and size of lesions with hyperintense signal were determined, compared with clinical characteristics and with findings on follow-up T2-weighted MRI. RESULTS: Twenty-three patients participated in the study. Thirteen patients had pure motor stroke, 1 pure sensory stroke, 8 sensorimotor stroke, and 1 ataxic hemiparesis. Twenty-two patients had at least one lesion with increased signal on diffusion-weighted MR images. These acute lesions were in the internal capsule/ basal ganglia/thalamus in 13 patients, subcortical white matter in 5 patients, brainstem in 2 patients, cortex (multiple small lesions) in 1 patient, and cortex + basal ganglia in 1 patient. The median volume of the lesions was 0.6 ml on the initial examination and on follow-up, of 17 patients after 1 to 5 months, 0.5 ml. CONCLUSIONS: Almost all patients with acute ischemic lacunar syndromes have acute lesions on echo-planar diffusion-weighted MRI within 3 days after stroke onset. These lesions are mostly small and subcortical, compatible with lacunar infarcts caused by single penetrating artery occlusion, but in a minor proportion of patients (2 of 23 in our study) a cortical involvement is found.

Acute Disease↗

Coronary sinus flow measurement by means of velocity-encoded cine MR imaging: validation by using flow probes in dogs.

PURPOSE: To validate coronary sinus flow measurements for quantification of global left ventricular (LV) perfusion by means of velocity-encoded cine (VEC) magnetic resonance (MR) imaging and flow probes. MATERIALS AND METHODS: Measurements of coronary sinus flow were performed in seven dogs by using VEC MR imaging at baseline, single coronary arterial stenosis, dipyridamole stress, and reactive hyperemia. These measurements were compared with flow probe measurements of coronary blood flow (CBF) in the left anterior descending coronary (LAD) and circumflex (CFX) arteries (CBF(LAD+CFX)) and coronary sinus. LV blood perfusion was calculated in milliliters per minute per gram from coronary sinus flow, and LV mass was obtained by using VEC and cine MR imaging. LV mass was validated at autopsy. RESULTS: CBF(LAD+CFX) and coronary sinus flow at VEC MR imaging showed close correlation (r = 0.98, P: <.001). The difference between CBF(LAD+CFX) and MR coronary sinus flow was 3.1 mL/min +/- 8.5 (SD). LV mass at cine MR imaging was not significantly different from that at autopsy (73.2 g +/- 12.8 vs 69. 4 g +/- 12.8). At baseline, myocardial perfusion was 0.40 mL/min/g +/- 0.09 at VEC MR imaging, and CBF(LAD+CFX) was 0.44 mL/min/g +/- 0. 08 (not significant). Reactive hyperemia resulted in 2.7- and 2. 3-fold increases in coronary sinus flow at VEC MR imaging and flow probe CBF(LAD+CFX), respectively. CONCLUSION: VEC MR imaging has the potential to measure coronary sinus flow during different physiologic conditions and can serve as a noninvasive modality to quantify global LV perfusion in patients.

Animals↗

Proton MR spectroscopy and preoperative diagnostic accuracy: an evaluation of intracranial mass lesions characterized by stereotactic biopsy findings.

BACKGROUND AND PURPOSE: MR imaging has made it easier to distinguish among the different types of intracranial mass lesions. Nevertheless, it is sometimes impossible to base a diagnosis solely on clinical and neuroradiologic findings, and, in these cases, biopsy must be performed. The purpose of this study was to evaluate the hypothesis that proton MR spectroscopy is able to improve preoperative diagnostic accuracy in cases of intracranial tumors and may therefore obviate stereotactic biopsy. METHODS: Twenty-six patients with intracranial tumors underwent MR imaging, proton MR spectroscopy, and stereotactic biopsy. MR spectroscopic findings were evaluated for the distribution pattern of pathologic spectra (NAA/Cho ratio < 1) across the lesion and neighboring tissue, for signal ratios in different tumor types, and for their potential to improve preoperative diagnostic accuracy. RESULTS: Gliomas and lymphomas showed pathologic spectra outside the area of contrast enhancement while four nonastrocytic circumscribed tumors (meningioma, pineocytoma, metastasis, and germinoma) showed no pathologic spectra outside the region of enhancement. No significant correlation was found between different tumor types and signal ratios. MR spectroscopy improved diagnostic accuracy by differentiating infiltrative from circumscribed tumors; however, diagnostic accuracy was not improved in terms of differentiating the types of infiltrative or circumscribed lesions. CONCLUSION: MR spectroscopy can improve diagnostic accuracy by differentiating circumscribed brain lesions from histologically infiltrating processes, which may be difficult or impossible solely on the basis of clinical or neuroradiologic findings.

Adult↗

Functional evaluation of extracardiac ventriculopulmonary conduits and of the right ventricle with magnetic resonance imaging and velocity mapping.

Extracardiac ventriculopulmonary conduits tend to deteriorate over time, developing both obstruction and regurgitation. In this prospective study, magnetic resonance imaging (MRI) was compared with Doppler echocardiography to determine whether MRI improves the noninvasive evaluation of conduit patients. Twenty-five patients (median age 10 years, range 2.5 to 32) were investigated 27 times with Doppler echocardiography and an MRI protocol with spin echo sequences for morphology, velocity mapping, and multislice gradient echo technique for right ventricular volume measuring. Cardiac catheterization data were available in 6 patients. Echocardiography could assess the morphology of the conduits in 6 patients, whereas MRI demonstrated all conduits efficiently. Doppler echocardiography could evaluate the occurrence of regurgitation in 18 patients and could quantify peak velocity in 20 of the patients. A technically adequate MRI velocity mapping was obtained in 25 patients. There was good agreement between MRI and Doppler echocardiography in establishing or not establishing regurgitation, but Doppler echocardiography was less reliable in evaluating the degree of regurgitation. The correlation between peak velocity determined with Doppler and magnetic resonance imaging was r = 0.63 [corrected]. Correlations between catheterization pressure gradients and noninvasive techniques were r = 0.97 for magnetic resonance imaging [corrected] versus catheterization, and r = 0.86 [corrected] for Doppler versus catheterization. MRI can provide complete information on the morphology and function of extracardiac ventriculopulmonary conduits, as well as of the right ventricle. If the results of MRI and echocardiography with Doppler are in agreement, heart catheterization and angiography can be avoided, even in patients considered for conduit replacement.

Adolescent↗

Magnetic resonance imaging of valvular heart disease.

The optimum management of patients with valvular heart diseases requires accurate and reproducible assessment of the valvular lesion and its hemodynamic consequences. Magnetic resonance imaging (MRI) techniques, such as volume measurements, signal-void phenomena, and velocity mapping, can be used in an integrated approach to gain qualitative and quantitative information on valvular heart disease as well as ventricular dimensions and functions. Thus, MRI may be advantageous to the established diagnostic tools in assessing the severity of valvular heart disease as well as monitoring the lesion and predicting the optimal timing for valvular surgery. This paper reviews the validation of these MRI techniques in assessing valvular heart disease and discusses some typical pitfalls of the techniques, including suggestions for solutions.J. Magn. Reson. Imaging 1999;10:627-638.

Blood Flow Velocity↗

Image artifacts due to a time-varying contrast medium concentration in 3D contrast-enhanced MRA.

The purpose of this work was to study image effects due to time-varying contrast medium concentration in contrast-enhanced three dimensional (3D) magnetic resonance angiography (MRA) images. Two different simulation models (1D and 3D) and two different contrast medium variation schemes were used. Phantom measurements were also performed. Experiments were performed for several different bolus timings. Similar sequence and image object parameters were used in both simulations and measurements (TE/TR 2. 1/7.8 mses, flip angle 30 degrees, T1/T2 1200-80/150-40 msec, flow velocity 100 cm/sec). A small variation in bolus timing yielded large variations in the appearance of the image effects, especially if the center of k-space was sampled in the vicinity of rapid contrast medium concentration variation. For a typical bolus injection in a patient, a severe signal loss but only minor ringing and edge artifacts appeared if the bolus injection was poorly timed. Effects of pulsatile flow were minor. The 3D model proved to be a useful tool in these studies. J. Magn. Reson. Imaging 1999;10:919-928.

Aorta↗

Quality assessment of localization technique performance in small volume in vivo 1H MR spectroscopy.

A new phantom and evaluation method for experimental evaluation of 1H-magnetic resonance spectroscopy single volume localization techniques regarding signal contamination (C), defined as the part of the signal originating outside the volume of interest, is presented. The quality assessment method is based on a spherical phantom with an oil/water interface in order to reduce susceptibility effects, and applied for stimulated-echo acquisition method (STEAM) and spin-echo (SE) sequences, echo times of 270, 135, and 10 ms, and cubic volumes of interest (VOI) of 1(3), 1.5(3), 2(3), 2.5(3), and 3(3) cm3. To be able to mimic measurements of the contamination in three dimensions the physical gradients representing the three orthogonal directions for slice selection were shifted in the pulse sequences. Contamination values in one dimension differed between 6.5% and 8.4% in SE sequences, and between 0.7% and 13.8% in STEAM sequences. In STEAM sequences a decrease of C with increasing VOI size was observed while SE sequences showed comparable C values for the different VOI sizes tested. The total contamination in three dimensions were 19% and 18% in SE and STEAM sequences with a TE of 270 ms, and 7% in a STEAM sequence with a TE of 10 ms, respectively. The presented evaluation method is easily applied to the new phantom and showed high reproducibility.

Artifacts↗

Left-to-right cardiac shunts: comparison of measurements obtained with MR velocity mapping and with radionuclide angiography.

PURPOSE: To investigate the agreement between two noninvasive methods, magnetic resonance (MR) velocity mapping and first-pass radionuclide angiography, to quantify the pulmonary-to-systemic blood flow ratio (QP/QS) in adults, adolescents, and children with left-to-right cardiac shunts. MATERIALS AND METHODS: The accuracy and precision of MR velocity mapping were studied in 12 control subjects (six men, six women) and in a phantom. MR velocity mapping and radionuclide angiography were performed on the same day in 24 patients (16 adults, two adolescents, six children; five male patients, 19 female patients). RESULTS: The mean error in QP/QS at MR velocity mapping in phantom experiments was -1% +/- 1 (mean +/- SD). In control subjects, QP/QS at MR velocity mapping was 1.03 +/- 0.03, and the cardiac index was 3.1 L/min/m2 +/- 0.2 and 3.2 L/min/m2 +/- 0.3 for women and men, respectively. In patients, QP/QS at radionuclide angiography was 14% +/- 13, higher than at MR velocity mapping. Interobserver variability was four times higher for radionuclide angiography compared with MR velocity mapping, 0% + 16 versus 0% +/- 4 (n = 12). The difference between repeated MR flow measurements in the same vessel was -1% +/- 5 (n = 36). CONCLUSION: The data suggest that MR velocity mapping is accurate and precise for measurements of shunt size over the whole range of possible QP/QS values.

Adolescent↗

Radiological diagnosis of acute stroke. Comparison of conventional MR imaging, echo-planar diffusion-weighted imaging, and spin-echo diffusion-weighted imaging.

PURPOSE: To compare conventional MR imaging, echo-planar diffusion-weighted imaging (EP-DWI) and spin-echo diffusion-weighted imaging (SE)-DWI at radiological diagnosis of acute stroke. MATERIAL AND METHODS: Twenty-seven patients (30-85 years old) were examined. Clinical examination was performed before MR imaging. All MR examinations were assessed by an experienced neuroradiologist blinded to clinical findings. RESULTS: In EP-DWI, every patient had a lesion corresponding to the clinical findings. EP-DWI was used as the gold standard. In conventional PD+T2 imaging, 23/59 focal lesions were interpreted as acute, which was false in 11 lesions, and 36/59 lesions were considered to be old, 6 were in fact acute. Nine acute lesions were only detected retrospectively and 12 acute lesions were not detected at all on PD+T2. SE-DWI including the apparent diffusion coefficient correlated fairly well with EP-DWI but the procedure was impractical. CONCLUSION: EP-DWI is reliable for diagnosis of early ischemic stroke, while SE-DWI performs reasonably well. Conventional PD+T2 imaging is not reliable for diagnosis of early ischemia.

Acute Disease↗