Search PubMed⌕ Search

Biomedical subjects

F Schmidt

Publications and source records attributed to F Schmidt.

At least 73 records · Page 4Linked to original sources

The impact of ergotamine-induced headache and ergotamine withdrawal on information processing.

Ergotamine abuse and subsequent ergotamine-induced headache is a common problem in the pharmacological treatment of migraine and other headache types; often, withdrawal therapy is necessary. This study investigated whether ergotamine abuse affects information processing and whether withdrawal therapy can lead to an improvement of information processing. We designed a standardized neurophysiological retrospective (ergotamine abuse) and prospective (ergotamine withdrawal) study in a supraregional headache outpatient clinic. Seventy-one patients abusing ergotamine derivatives with subsequent daily headache were enrolled and compared to 36 migraine patients without ergotamine intake and 36 healthy subjects. Information processing was evaluated by latencies and amplitudes of visually evoked event-related potentials (ERP) before and after ergotamine withdrawal therapy. P3 latency of the ERP was significantly increased in ergotamine abuse (442 +/- 45 ms) versus migraine (415 +/- 40 ms) and healthy subjects (410 +/- 33 ms), there was no difference between ergotamine tartrate and dihydroergotamine abuse. The migraine specific loss of habituation in information processing as measured by P3 latency could not be observed in migraine patients with ergotamine abuse. After successful withdrawal therapy in 36 patients, the abnormally prolonged P3 latency was significantly shortened (452 +/- 47 ms versus 433 +/- 30 ms; P < 0.004). Our findings imply that information processing is impaired by ergotamine abuse and can be improved but not normalized after withdrawal therapy. Furthermore, our data provide strong evidence that ergotamine, besides its peripheral effects, has a central mode of action.

Adrenergic alpha-Agonists↗

Preliminary experience with interactive guided brain biopsies using a vertically opened 0.5-T MR system.

The purpose of our study was to evaluate the feasibility and accuracy of brain biopsies performed within a vertically opened MR system. We worked with the interventional 0.5-T MR "SIGNA SP" (General Electric Medical Systems, Milwaukee, Wis.) with an integrated tracking device "Flashpoint Position Encoder" (Image Guided Technologies, USA). As a holding device for this instrument we constructed a special frame. The whole system allows an exact adjustment of an optimum biopsy direction and guidance of the biopsy in a non-stereotactic, interactive mode in near real-time. As biopsy tools we used MR-compatible aspiration and specially made side-cut needles (Daum, Germany; E-Z-EM, USA). We performed a prospective diagnostic brain biopsy study in 18 patients. Guidance of the needle was carried out using gradient-echo single-slice technique. The sample was taken after controlling the exact position of the needle tip on spin-echo images. In 12 cases an exact neuropathological diagnosis was possible. In 6 cases of negative biopsy (4 aspiration biopsies) the samples were not representative. Our results demonstrate the feasibility of interactive MR-guided minimally invasive brain biopsies in an open MR system. The best results were achieved using cut needles for biopsies of contrast-enhancing lesions visible on T1-weighted gradient-echo guidance sequence.

Adult↗

Chondromatosis of the ankle joint (Reichel syndrome).

A case of chondromatosis of the upper ankle joint in childhood is described. It is a monoarticular disease with a good prognosis, frequently without known prior trauma or inflammation, although often free fragments of cartilage are seen in the joint cavities. It originates from the synovium of the joint, and is known in the literature as Reichel syndrome.

Acute Disease↗

Open MR imaging in spine surgery: experimental investigations and first clinical experiences.

INTRODUCTION: The latest open MRI technology allows to perform open and closed surgical procedures under real-time imaging. Before performing spinal trauma surgery preclinical examinations had to be done to evaluate the artifacts caused by the implants. METHODS: The MRT presented is a prototype developed by GE. Two vertically positioned magnetic coils are installed in an operation theater. By that means two surgeons are able to access the patient between the two coils. Numerous tests regarding the material of instruments and implants were necessary in advance. The specific size of the artifact depending on the pulse sequence and the positioning within the magnetic field had to be examined. RESULTS: The magnifying factors of the artifact in the spin echo sequence regarding titanium are between 1.7 and 3.2, depending on the direction of the magnetic vector. Regarding stainless steel they are between 8.4 and 8.5. In the gradient echo sequence the factors are between 7.5 and 7.7 for titanium and between 16.9 and 18.0 for stainless steel. The tip of an implant is imaged with an accuracy of 0 to 2 mm. Since September 1997 16 patients with unstable fractures of the thoracic and lumbar spine have been treated by dorsal instrumentation in the open MRI. Percutaneous insertion of the internal fixator has proven a successful minimally invasive procedure. The positioning of the screws in the pedicle is secure, the degree of indirect reduction of the posterior wall of the vertebral body can be imaged immediately. The diameter of the spinal canal can be determined in any plane. DISCUSSION AND CONCLUSION: The open MRI has proven useful in orthopedic and trauma surgery. The size and configuration of the artifacts caused by instruments and implants is predictable. Therefore exact positioning of the implants is achieved more easily. Dorsal instrumentation of unstable thoracolumbar fractures with a percutaneous technique has turned out safe and less traumatic under MR-imaging. Real-time imaging of soft tissue and bone in any plane improves security for the patient and allows the surgeon to work less invasively and more precisely.

Artifacts↗

Open MRI-guided neurosurgery.

OBJECTIVES: A number of different image-guided surgical techniques have been developed during the past decade. None of these methods can provide the surgeon with information about the dynamic changes that occur intra-operatively. MATERIAL AND METHOD: The first vertical open 0.5T MRI-scanner for intra-operative MRI-guided neurosurgery in Germany was installed at the University of Leipzig during the summer 1996. Since autumn 1996 a number of surgical procedures including biopsies (n = 31), craniotomies (n = 32), transsphenoidal procedures (n = 8) and interstitial lasertherapies (n = 3) have been performed using intra-operative MR image guidance. RESULTS: The development of MR-compatible and MR-safe non-magnetic instruments and components had to be solved. Specific surgical instruments were developed to perform biopsies, craniotomies, microsurgical tumour resections and transsphenoidal procedures in the 0.5-T open MRI. Several components required adaptation including the head holder the stereotactic navigation device, the high speed drill, the suction unit, the ultrasonic aspirator, the bipolar coagulation, the laser probe and the surgical microscope. All these newly developed technical features enable the neurosurgeon to perform a large number of surgical procedures under direct control and guidance of intra-operative MR imaging. In contrast to frame-based for framless navigation systems, intra-operative MRI provides accurate and immediate information during the progress of surgery. These intra-operative images allow definitive localization and targeting of the lesions and accommodate anatomical changes that may occur during surgery. CONCLUSION: Intra-operative MRI is helpful for navigation as well as determining of tumour margins to achieve a complete and safe resection of intracranial lesions. Complications related to the surgical procedure are reduced and the risk of neurological deterioration due to tumour removal and postoperative complications is minimized. It can be concluded that the intra-operative application of interventional MRI technology may represent a major step forward in the field of neurosurgery.

Biopsy↗

The dispute about the external sphincter and the urogenital diaphragm.

PURPOSE: Basic scientific facts, such as anatomical structures, are rarely subjected to critical reappraisal. Nevertheless, several clinical phenomena exist which are inconsistent with the description of the anatomy of the so-called external sphincter muscle and urogenital diaphragm. MATERIALS AND METHODS: We performed a global examination of the anatomy of the entire lower urinary tract in 50 male autopsy specimens. For comparison magnetic resonance imaging of the same regions was performed on 12 healthy patients. RESULTS: Direct comparison of the results of both methods revealed the exact same topography of the bladder neck. The external sphincter or musculus sphincter urethrae is an independent morphological unit separated from the surrounding pelvic floor muscles by connective tissue. CONCLUSIONS: The musculus transversus perinei profundus or deep transverse perineal muscle, which is believed to constitute the major element of the urogenital diaphragm, does not exist. There is histomorphological evidence that the external sphincter consists of a striated (musculus sphincter urethrae transversostriatus) and smooth muscle (musculus sphincter urethrae glaber) component.

Adolescent↗

[MR-track pointer. A reusable device for localization during interventions].

PURPOSE: Development of an helpful instrument for a better planning and orientation during MR guided interventions. MATERIAL AND METHODS: We developed a reusable, sterilizable instrument that can be filled both with a solution of Gd-DTPA (1%) and with a sodium chloride solution (0.9%). The pointer has a diameter of 3 and 5 mm resp. and its length is 100-150 mm. The instrument can be combined with an interactive stereotactic tracking device. RESULTS: The MR-Track-Pointer can be fixed to the two handpieces of the integrated interactive tracking system without problems. The pointer can be seen both on T1w and T2w sequences inside and outside of the tissue. This new instrument can be interactively used for reliable planning the biopsy trajectory, planning craniotomies and identifying structures which are only visible on MR images. CONCLUSIONS: The MR-Track-Pointer is an ideal supplement for the integrated virtual tracking system. It permits a minimal invasive orientation and facilitates the exact localisation of suspect lesions in sensible regions during MR guided interventions, e.g. diagnostic biopsies and tumour resections.

Biopsy↗

An automatic method for the identification and interpretation of clustered microcalcifications in mammograms.

We investigated a method for a fully automatic identification and interpretation process for clustered microcalcifications in mammograms. Mammographic films of 100 patients containing microcalcifications with known histology were digitized and preprocessed using standard techniques. Microcalcifications detected by an artificial neural network (ANN) were clustered and some cluster features served as the input of another ANN trained to differentiate between typical and atypical clusters, while others were fed into an ANN trained on typical clusters to evaluate these lesions. The measured sensitivity for the detection of grouped microcalcifications was 0.98. For the task of differentiation between typical and atypical clusters an Az value of 0.87 was computed, while for the diagnosis an Az value of 0.87 with a sensitivity of 0.97 and a specificity of 0.47 was obtained. The results show that a fully automatic computer system was developed for the identification and interpretation of clustered microcalcitications in mammograms with the ability to differentiate most benign lesions from malignant ones in an automatically selected subset of cases.

Breast Diseases↗

Hypertension-induced end-organ damage : A new transgenic approach to an old problem.

Angiotensin (Ang) II-induced organ damage has fascinated students of hypertension since the work of Wilson and Byrom. We are investigating a double transgenic rat (dTGR) model, in which rats transgenic for the human angiotensinogen and renin genes are crossed. These rats develop moderately severe hypertension but die of end-organ cardiac and renal damage by week 7. The heart shows necrosis and fibrosis, whereas the kidneys resemble the hemolytic-uremic syndrome vasculopathy. Surface adhesion molecules (ICAM-1 and VCAM-1) are expressed early on the endothelium, while the corresponding ligands are found on circulating leukocytes. Leukocyte infiltration in the vascular wall accompanies PAI-1, MCP-1, and VEGF expression. The expression of TGF-beta and deposition of extracellular matrix proteins follows, which is accompanied by fibrinoid vasculitis in small vessels of the heart and kidneys. Angiotensin-converting enzyme inhibitors and AT1 receptor blockers each lowered blood pressure and shifted pressure natriuresis partially leftward by different mechanisms. When combined, they normalized blood pressure, pressure natriuresis, and protected from vasculopathy completely. Renin inhibition lowered blood pressure partially, but protected from vasculopathy completely. Endothelin receptor blockade had no influence on blood pressure but protected from vasculopathy and improved survival. We show evidence that Ang II stimulates oxidative stress directly or indirectly via endothelin 1 and that NFkappaB is upregulated in this model. We speculate that the transcription factors NFkappaB and AP-1 are involved with initiating chemokine and cytokine expression, leading to the above cascade. The unique model and our pharmacological probes will enable us to test these hypotheses.

Angiotensin II↗

Monocyte infiltration and adhesion molecules in a rat model of high human renin hypertension.

Hypertension and kidney damage in the double transgenic rat (dTGR) harboring both human renin and human angiotensinogen genes are dependent on the human components of the renin angiotensin system. We tested the hypothesis that monocyte infiltration and increased adhesion molecule expression are involved in the pathogenesis of kidney damage in dTGR. We also evaluated the effects of long-term angiotensin-converting enzyme (ACE) inhibition, AT1 blockade, and human renin inhibition on monocyte recruitment and inflammatory response in dTGR. Systolic blood pressure and 24-hour albuminuria were markedly increased in 7-week-old dTGR as compared with age-matched normotensive Sprague Dawley rats. We found a significant monocyte/macrophage infiltration in the renal perivascular space and increased expression of intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1) in the interstitium, intima, and adventitia of the small renal vessels. alphaLbeta2 integrin and alpha4beta1 integrin, the corresponding ligands for ICAM-1 and VCAM-1, were also found on infiltrating monocytes/macrophages. The expression of plasminogen activator inhibitor-1 and fibronectin in the kidneys of dTGR were increased and distributed similarly to ICAM-1. In 4-week-old dTGR, long-term treatment with ACE inhibition (cilazapril), AT1 receptor blockade (valsartan), and human renin inhibition (RO 65-7219) (each drug 10 mg/kg by gavage once a day for 3 weeks) completely prevented the development of albuminuria. However, only cilazapril and valsartan were able to decrease blood pressure to normotensive levels. Interestingly, the drugs were all equally effective in preventing monocyte/macrophage infiltration and the overexpression of adhesion molecules, plasminogen activator inhibitor-1, and fibronectin in the kidney. Our findings indicate that angiotensin II causes monocyte recruitment and vascular inflammatory response in the kidney by blood pressure-dependent and blood pressure-independent mechanisms. ACE inhibition, AT1 receptor blockade, and human renin inhibition all prevent monocyte/macrophage infiltration and increased adhesion molecule expression in the kidneys of dTGR.

Angiotensinogen↗

Application of the ADEPT strategy to the MDR resistance in cancer chemotherapy.

New prodrugs consisting of a beta-D-glucuronic acid linked to a MDR reversal agent (verapamil, quinine or dipyridamole) through a self-immolative spacer were synthesized. Four of them were selected for their reduced cytoxicity and beta-glucuronidase enzymatic efficient hydrolysis. Combined use of these prodrugs with a beta-D-glucuronyl-spacer-doxorubicin (HMR1826) according to an ADEPT strategy restored in vitro the sensibility of a MDR resistant strain.

Animals↗

Contrast-enhanced spiral CT of the head and neck: comparison of contrast material injection rates.

BACKGROUND AND PURPOSE: Contrast-enhanced spiral CT studies of the head and neck are performed frequently using contrast material volumes of approximately 30 g iodine and a scan delay of 30-45 seconds. Because little is known about the effects of contrast material injection rates on tissue enhancement, this was prospectively investigated in our study. METHODS: Ninety-seven patients underwent spiral CT of the head and neck. Each patient was assigned randomly to one of four groups who received 100 mL of nonionic contrast material (300 mg I/mL) at different monophasic injection flow rates with 1.5, 2, 3, and 4 mL/s. Scanning started after a constant delay of 35 seconds. The attenuation of the carotid artery, jugular vein, and sternocleidomastoid muscle was measured over time and the attenuation of the submandibular and thyroid gland was evaluated. Vascular attenuation of at least 150 HU was considered to be sufficient. RESULTS: The mean scan time was 33+/-5 seconds. The study, using an injection rate of 2 mL/s, showed the longest time of sufficient overall (arterial and venous) vessel attenuation (27+/-4 seconds, P< or =.008). The injection flow rate did not influence significantly muscular attenuation (mean enhancement during scan time: 9+/-7 HU). The 1.5 mL/s protocol showed the lowest attenuation values of the submandibular gland (81+/-12 HU) and the highest attenuation values of the thyroid gland (164+/-22 HU), but the attenuation of the thyroid gland was not statistically different from that revealed by the 2 mL/s protocol. CONCLUSION: Using 100 mL of intravenous contrast material with 300 mg I/mL for spiral CT studies of the entire head and neck, the optimal injection flow is 2 mL/s, whereas lower flow rates resulted in insufficient venous enhancement.

Adult↗

Medical audit after 26,711 breast imaging studies: improved rate of detection of small breast carcinomas (classified as Tis or T1a,b)

BACKGROUND: Patients with breast carcinomas 1 cm or smaller are known to have the highest long term survival rates. This pathologic measurement was used as a quality indicator of the performance of different reporting radiologists. METHODS: A total of 26,711 diagnostic breast imaging studies were performed over a period of 5 years. Within the first 18 months, several general radiologists reported mammograms, whereas during the rest of the evaluated period only 1 radiologist was responsible for all mammography reporting. Radiologic findings leading to open biopsy were correlated with the histologic results. The cancer sizes from the histologic reports were recorded, and the number of Tis, T1a, and T1b cancers were correlated with all cancers found at open biopsy. The change in the relative percentage of small cancers was evaluated, along with the positive predictive value (PPV). RESULTS: Between 1991 and 1995, 26,711 breast imaging studies were performed. This resulted in 2698 open biopsies with 620 breast carcinomas detected. In the first 2 years, the percentages of small cancers detected (Tis or T1a,b) were 27.2% and 25.7%, respectively. In the third, fourth, and fifth years, the percentages increased to 38.8%, 34.5%, and 38.8%, respectively. At the same time, the PPV increased slightly, from 0.23 in 1991 to 0.27 in 1995. CONCLUSIONS: The detection of curable early stage breast carcinomas requires the dedication and commitment of a small group of radiologists who are willing to spend most of their time on this single subject. This will increase considerably the number of early stage cancers found and reduce the number of false-positive diagnoses. [See editorial counterpoint on pages 2430-1 and reply to counterpoint on pages 2432-3.]

Breast Neoplasms↗

[Operation of multidisciplinary, interventional 0.5 Tesla magnetic resonance tomograph. Technical and logistic problems and initial clinical results].

Multidisciplinary usage of a MRI system with a superconducting 0.5-T magnet (Signa SP, General Electric) with a vertical gap suited for diagnostic and therapeutic interventions raises complex problems. The MR equipment, including a special localizing system and the instruments for diagnostic and therapeutic interventions, is described. Before putting the system into operation tests were necessary to check MR compatibility of various materials and instruments and to build some auxiliary equipment. We report on the coordinating activities of the radiologist in the context of MR use by different medical specialities. Within the course of 12 months, 428 examinations/interventions of different kinds were carried out, among them 75 functional examinations of the spine or of joints, 31 diagnostic biopsies, 23 cerebral biopsies, and 23 operations. The special design of the Signa SP allows the whole scale of functional examinations, up to complete neurosurgical interventions, in the sitting position and under nearly real-time imaging control.

Equipment Design↗