Search PubMed⌕ Search

Biomedical subjects

F Schön

Publications and source records attributed to F Schön.

At least 19 recordsLinked to original sources

[Long term results after cochlear implantation in elderly patients].

BACKGROUND: Cochlear implantation has become the method of choice for the treatment of deaf patients. A better technology of stimulation opened a wider field of patients suitable for cochlear implantation. Aim of the present study was to evaluate to which extent senior patients benefit by cochlear implantation. PATIENTS AND METHODS: 36 patients between 65 and 85 years were tested by the Freiburger speech test for monosyllabic words and by the HSM sentence test with and without noise. The results were compared to those of younger implanted patients (16 - 64 years, n = 101). RESULTS: The speech perception for monosyllabic words did not differ significantly between both groups. A maximum plateau in speech perception for monosyllabic words was reached after 2 years at 55 %. The HSM sentence test revealed significant differences in the increase of speech perception between senior and younger patients in the first post surgical year. After one year elderly patients reached the same perception score as younger patients with a maximum of approximately 80 % after 3 years. At a signal to noise ratio of 15 % younger patients achieved a maximal perception of 55 % after 1 year whereas senior patients needed 4 years to reach this level. CONCLUSIONS: Senior patients benefited by cochlear implantation to the same extent as younger patients did. Senior patients gained a similar speech perception level as younger implanted patients although the elderly needed more time to reach the same scores. Nevertheless, cochlear implantation should not be denied due to age alone.

Aged↗

[Cochlea implantation: results and costs, a review].

The cochlear implantation, especially after bilateral operation provides a reliable and outstanding compensation in bilateral complete deafness or severe hearing impairment. Directional hearing can be restored with bilateral implantation so that warning signals are localized correctly and speech in noise is easier understood. Thus, rehabilitation is restored to a high degree. The involved expenses are severe, but are lower for the society when compared to the amount of money necessary to substitute a completely deaf patient lifelong.

Adolescent↗

[The Würzburg Ear Forms: a system to document surgery and follow-up evaluation].

BACKGROUND: About a decade ago a PC based system to document surgery and follow up evaluation was installed. At that time the wide spread DOS systems provided only inputs via the keyboard. However, we believed that to assure the system would be accepted by the user, a graphical user interface would be necessary. Such an interface provides greater user-comfort and ensures the validity of entered data. METHODS: A simple graphical platform was installed, which provided all the necessary functions without being too complex. Several forms were designed for data collection. The first form implemented was designed for ear surgery. It comprises 356 items. The relevant data in the form are selected by a mouse click from possible alternatives. Although a large number of items are provided, it takes only one to two minutes to fill in the form. RESULTS: At present, September 2001, the database contains 10 453 records related to ear operations, 9633 preoperative audiograms and the results from 16 140 follow up evaluations. A special language and an interpreter for analyzing the data were added to complete the system. CONCLUSIONS: The large number of cases stored in the database allows data analysis with a high level of statistical confidence for any conclusions based upon the data. It also allows investigations of the simultaneous influence of a large number of variables on the results.

Computer Graphics↗

[The Würzburg questionnaire for assessing the quality of hearing in CI-children (WH-CIK)].

BACKGROUND: The goal of this study was to compare the auditory behaviour of bilaterally implanted children while using both CIs to their auditory behaviour during the time when they were using one CI. METHODS: For this purpose a questionnaire looking at different aspects of hearing such as hearing in background noise, in complex listening situations and directional hearing was developed. The questionnaire was completed by the parents of 28 bilaterally implanted children. They were instructed to state their judgement on the behaviour of their children. The parents scaled their judgements using a method of extended category scaling similar to that applied in the loudness scaling with the Würzburg hearing field (WHF). Each of the five verbal categories was subdivided into 10 numerical subdivisions, so that the parents were able to express judgements lying between the different categories. RESULTS: Eight out of eleven items showed that hearing with bilateral CIs was significantly better than with one CI (p < 0,003). The two items, which did not show a significant difference between the two conditions were those related to the interest in auditory rehabilitation and to aversion to noise. CONCLUSIONS: The questionnaire has proven to be a useful instrument to assess the quality of hearing in children. The possibility of bilateral implantation should be considered during the decision process prior to implantation.

Adolescent↗

Speech understanding in quiet and noise in bilateral users of the MED-EL COMBI 40/40+ cochlear implant system.

OBJECTIVE: The purpose of the study was to investigate speech understanding in quiet and noise in subjects bilaterally implanted with multi-channel cochlear implants. DESIGN: Nine adults bilaterally implanted with MED-EL implants were included in the study. The subjects were tested in three conditions: with both implants, with the right implant only, and with the left implant only. Speech tests included monosyllables in quiet and sentences in noise (10 dB signal to noise ratio). Speech was presented from the front, and noise was presented from either 90 degrees or 270 degrees azimuth. RESULTS: All subjects reported benefit from bilateral stimulation. Speech scores for all subjects were higher with bilateral than with unilateral stimulation. The average score across subjects for sentence understanding was 31.1 percentage points higher with both cochlear implants compared with the cochlear implant ipsilateral to the noise, and 10.7 percentage points higher with both cochlear implants compared with the cochlear implant contralateral to the noise. The average score for recognition of monosyllabic words was 18.7 percentage points higher with both cochlear implants than with one cochlear implant. All of these differences in average scores were significant at the 5% level. CONCLUSIONS: Bilateral cochlear implantation provides a significant benefit in speech understanding in both quiet and noise.

Acoustic Stimulation↗

Candidate tumour suppressor genes at 11q23-q24 in breast cancer: evidence of alterations in PIG8, a gene involved in p53-induced apoptosis.

One of the most consistently deleted chromosomal regions in solid tumours is 11q23-q25, which consequently has been postulated to harbour one or more tumour suppressor loci. Despite large efforts to identify the responsible genes, the goal remains elusive, but as knowledge accumulates new candidates are emerging. The present study was undertaken in an attempt to assess the possible implication of four genes residing at 11q23-q24, in a population of early onset breast cancer (n=41). The coding sequence of PIG8, CHK1, LOH11CR2A and PPP2R1B were screened for mutations using the protein truncation test or single-strand conformational polymorphism, in combination with direct DNA sequencing. Varying proportions of alterations were detected, ranging from 6% in PPP2R1B to 39% in PIG8. Many of these changes were deletions, in some cases corresponding to complete exons, thus likely to represent splice variants, while others were presumed to arise from aberrant splicing, since they occurred at sites with resemblance to exon/intron borders. Considering only bona fide mutations, the highest alteration frequency (17%) was again found in PIG8. Most of these alterations were likely to have an adverse impact on the translated protein as they either altered the reading frame or affected phylogenetically conserved residues. Our data represent the first evidence of alterations in the PIG8 gene in human malignancies, a finding that substantiates its role as a potential tumour suppressor gene as suggested by its involvement in p53-induced apoptosis.

Adult↗

[Inner ear depression after middle ear interventions].

BACKGROUND: Any type of otosurgical procedure involves the risk of inner ear damage. As middle ear surgery is also performed for functional reasons this risk should be taken into consideration. The aim of this study was to analyse the frequency and the nature of sensorineural hearing loss following chronic ear surgery. PATIENTS: A total of 3989 middle ear cases operated on between 1991 and February 1999 at the Department of Otorhinolaryngology, Head and Neck Surgery, University of Würzburg, Germany were studied retrospectively: 781 type I tympanoplasties, 2408 type III tympanoplasties and 800 cases of stapes surgery. The pre- and the postoperative audiograms in the frequency range between 500 and 8000 Hz were analysed and correlated to the different intraoperative findings. RESULTS: Sensorineural hearing loss occurred in a total of 1.3% of 2224 patients with normal preoperative bone conduction thresholds: 0.2% became deaf, 0.8% acquired a high tone loss at 4 kHz and in 0.3% patients also 2 kHz was affected. None of the documented intraoperative complications such as bleeding, unexpected opening of a semicircular canal, extensive manipulation at the ossicular chain or a gusher phenoma showed a relevant effect on postoperative bone conduction thresholds. The incidence of high tone loss was not increased in cases of extensive drilling of the temporal bone. An unexpected opening of the vestibulum led to a small, but statistically significant change in postoperative bone conduction thresholds. CONCLUSIONS: Our results demonstrated that the risk for sensorineural hearing loss caused by middle ear surgery is low. None of the analysed factors seems to be a relevant prognostic risk factor for postoperative inner ear depression.

Adolescent↗

Effect of gingival fluid on marginal adaptation of Class II resin-based composite restorations.

PURPOSE: To evaluate in vitro the marginal quality of Class II composite restorations at the gingival enamel margins as affected by contamination of the cavities with gingival fluid (GF) during different steps of resin bonding procedures. MATERIALS AND METHODS: 70 Class II cavities were prepared in extracted human molars and restored with composite using a multi-component bonding system (OptiBond FL/Herculite XRV; OPTI) or a single-bottle adhesive (Syntac Sprint/Tetric Ceram; SYN). The cavities were contaminated with human GF: C1 after acid etching, C2 after application of the primer (OPTI) or light-curing of the primer-adhesive (SYN), and C3 after light-curing of the resin adhesive (OPTI). Uncontaminated cavities were used as the control (C0). The restored teeth were subjected to thermocycling (TC) and replicated for SEM analysis of marginal gap formation. Microleakage at the gingival margins was determined by dye penetration with basic fuchsin. STATISTICS: non-parametric tests (Kruskal-Wallis test, Mann-Whitney test with Bonferroni correction). RESULTS: In both bonding systems, contamination with GF after acid etching (C1) did not impair the marginal quality; the mean percentages of continuous margin/mean depths of dye penetration were: OPTI: C0: 88.5%/0.10 mm, C1: 95.6%/0.04 mm; SYN: C0: 90.9%/0.08 mm, C1: 97.0%/0.05 mm. Marginal adaptation was adversely affected when GF contamination was performed after

Acid Etching, Dental↗

[Reliable fixation of cochlear implant electrode mountings in children and adults--initial experiences with a new titanium clip].

BACKGROUND: There is a reported 1% incidence of delayed migration of extrusions of the electrode arrays out of the cochlea. METHODS: A titanium clip to fix the electrode array of the MED EL Combi 40 Cochlear Implant System is described. The clip is designed and shaped in a double U configuration. The clip material allows easy adaption to the individual anatomical situation. The clip is fixed to a bony bridge at the incus bar and fixes the electrode in a plane parallel to the chorda facial angle. It is closed around the electrode similarly to a stapes piston around the incus. Additional tests which examined the possible risk of damaging the electrode carrier and clinical findings are described. RESULTS: The clip was used in 23 cases with a follow-up period up to 1 year. No signs for dislocation of the electrode were found. In one revision case the clip was covered with a thin mucosal layer. The electrode array showed no signs of damage. Intraoperative findings confirmed the experimental tests on the electrode fixation. CONCLUSION: The titanium clip facilitates safe and quick fixation of the electrode array and prevents dislocation. its flexibility and shape minimizes the risk of damage.

Adult↗

[Voice prostheses with sound-producing metal reed element--an experimental study and initial clinical results].

BACKGROUND: Following total laryngectomy the voice is produced by esophageal speech as well as with voice prostheses by vibrations of pharyngeal mucosal folds. This pharyngeal sound normally has a significantly lower fundamental frequency than the healthy voice (men about 120 Hz, women about 240 Hz, pharyngeal voice about 70 Hz), which is a handicap especially for female laryngectomy patients. In order to improve the postlaryngectomy voice, a new type of voice prostheses containing an integrated sound-producing metallic reed element was developed (ADEVA Company, Lübeck, Germany). METHODS/PATIENTS: Thirty-five of these new sound-producing voice prostheses were tested in vitro for different prosthesis-specific physical parameters (pressure, flow, sound pressure, flow resistance, frequency range). In 15 voice prosthesis speakers, a sound-producing prosthesis was introduced during a routine outpatient visit. Besides measurement of the above mentioned physical parameters in patients with conventional and sound-producing prostheses, the resulting voice as also evaluated by means of a video recording. RESULTS: In vitro all prostheses with the metallic reed element produced a clear sound. Flow resistance of the prostheses was slightly elevated by the reed element. Insertion of the prostheses was hindered by the reed element. Period of uninterrupted sound production was prolonged after insertion of a sound-producing prosthesis and patients could speak on a lower pressure level, but the sound of the reed element was permanently distinguishable only in 6 of 15 patients. CONCLUSIONS: In principle a variation of the pharyngeal voice by means of a sound producing element, which is integrated into a voice prosthesis, is possible. The current design of the metallic reed element tested is not yet suitable for routine clinical use: 1. The reed element is too sensitive and is easily damaged during insertion, so the insertion device has to be improved. 2. The sound producing element is blocked by small amounts of tracheal secretions, so that this element should be replaceable separately without requiring removal of the silicone value (if possible by the patient himself). Prior to insertion of the sound producing voice prosthesis the maximum air flow through the shunt should be measured to determine if the patient can produce the necessary air flow for activation of the reed element. A further improvement for these special types of voice prostheses would be a sound producing element, which generates a variable frequency of sound. Limiting the patient to only one fundamental frequency creates a monotone, which does not sound naturally. Initial progress toward a sound-producing voice prostheses has been made. This should be followed by the necessary improvements in order to improve the feasibility of this design for routine clinical use.

Equipment Failure Analysis↗

[Tragus perichondrium-cartilage island transplant in middle ear surgery. Method and results after 5 years].

Temporalis fascia remains the most widespread material for reconstructing the tympanic membrane in tympanomastoid surgery. If total or partial ossicular replacement prostheses are needed or pathology of the eustachian tube causes ventilation impairment, a more rigid transplant material is required. Between 1989 and 1994 perichondrium-cartilage composite grafts were used in a series of 597 cases of tympanomastoid surgery performed at the University ENT Clinic of Würzburg. The graft was taken from the tragus and prepared as a cartilage island with perichondrium attached to one side, the perichondrium-cartilage island transplant (PCI). If reconstruction of the ossicular chain was necessary, glass ionomer cement protheses (IONOS) were used. Closure of the tympanic membrane could be achieved in 90% of all cases. In those cases where ossicular chain reconstruction was postponed to a second procedure, closure of the drum was achieved in 96%. The audiological results of the different type III procedures were evaluated. By using the PCI technique a favorable closure of the air-bone gap to 10-25 dB was achieved, even in cases with advanced ear pathology technique and results are presented in detail.

Audiometry, Pure-Tone↗

[Recent morphofunctional findings on the left atrium: their relations to thromboembolic risk].

In the past, the left atrial appendage has been considered a "useless" structure but associated to thromboembolic complications; its physiologic role is still undefined. Owing to its great distensibility, left atrial appendage positively influences atrial compliance and left ventricular performances. In addition this structure seems to play an important role in circulatory homeostasis by the release of atrial natriuretic factor in response to volume loading and atrial stretch. Transesophageal echocardiography provides a detailed anatomical characterization of this structure and, by means of Doppler flow velocities recordings, supplies relevant functional data. Despite their anatomical contiguity, the left atrium and atrial appendage result from a separate embryonic development; likewise, their function may differentiate. In the left atrial appendage a quadriphasic flow pattern has been described in subjects with sinus rhythm; however, as we reported, in some patients a more complex Doppler pattern can be observed, with an additional systolic forward flow wave which is presumably due to reflection phenomena. In patients with atrial fibrillation, an irregular flow pattern has been detected, which is mostly dependent on the duration of the arrhythmia, the underlying heart disease and the left atrial pressure. By transesophageal echocardiography a clear correlation has been established between the left atrial appendage slow flow and the occurrence of thromboembolic events; however, while waiting data from large studies, stratification of patients according to thromboembolic risk and decisions about anticoagulant prophylaxis should be performed by clinical information and transthoracic echocardiographic findings. No clinical or echocardiographic parameter has been found to be predictive of the thromboembolic events after cardioversion; in this setting the exclusion of atrial or atrial appendage thrombi by transesophageal echocardiography does not rule out the need for anticoagulation in patients with atrial fibrillation undergoing electrical or pharmacological cardioversion.

Atrial Function, Left↗

[Atrial fibrillation--the value of transesophageal echocardiography].

Transesophageal echocardiography is superior to transthoracic echocardiography in detection of superior to transthoracic echocardiography in detection of left atrial thrombi and spontaneous echocardiographic contrast, particularly in patients with atrial fibrillation and spontaneous echocardiographic contrast, thrombus formation is likely. In addition to the morphology, Doppler-echocardiography can be used to access left atrial appendage function. In patients with lone atrial fibrillation, reduced velocity was found in 60%, and no flow was detected in the left atrial appendage in 40%. These patients had a higher risk for spontaneous echocardiographic contrast and thrombus formation. As left atrial thrombi are found in 12% of patients, transesophageal echocardiography can be used to avoid cardioversion in these patients, which may lead to cerebral or peripheral emboli. Despite ruling out left atrial thrombi, embolism occurred after cardioversion when anticoagulation was insufficient or not performed. Current investigations are undertaken in order to demonstrate the clinical benefit of transesophageal echocardiography in patients with left atrial fibrillation.

Atrial Fibrillation↗