Search PubMed⌕ Search

Biomedical subjects

F Peter

Publications and source records attributed to F Peter.

47 records · Page 3Linked to original sources

Lead-erythrocyte protoporphyrin correlation in blood of exposed workers.

A systematic survey of blood samples from 174 industrial workers occupationally exposed to lead fumes and lead dust, revealed some poor correlations between the lead (Pb) level and the free erythrocyte protoporphyrin (FEP) level. In addition to those workers who had an expected correlation (normal Pb-normal FEP or elevated Pb-elevated FEP) there were two groups with atypical correlations. In one group a normal Pb level was associated with an elevated FEP level and in the other group an elevated Pb level was associated with a normal FEP level. This shows that neither the Pb nor the FEP test can substitute for the other. Since the individual FEP response to Pb absorption is unpredictable, both tests should be carried out routinely. This would make it possible to determine simultaneously the degree of absorption (Pb level) and the degree of intoxication (FEP level) and would improve significantly the assessment of undue lead absorption of occupationally exposed workers. If, however, only one of these tests is used for screening the other test should always be carried out as a confirmatory test when the screening detects an elevated Pb or FEP level.

Environmental Exposure↗

Quantitative analysis of human serum cholesterol by thin-layer chromatographic spot test.

A fast, inexpensive, simple method is described for the determination of the total cholesterol concentration in human serum. The cholesterols (free and esterified) are extracted from serum by a double extraction procedure, using isopropanol-water-10 N sodium hydroxide (250:125:10) and then n-octane. An aliquot of the octane extract is spotted on a thin-layer plate and the cholesterol in the spot is rendered visible using an aqueous phosphomolybdic acid staining solution and a heat treatment for the color development. The colored spot is scanned with a densitometer.

1-Propanol↗

The stability of human blood lead in storage.

Whole blood specimens from 12 occupationally exposed workers were stored for 10 weeks either in heparin or EDTA at 22 degrees, 4 degrees, and -20 degrees C for the study of the stability of lead in storage. The lead concentrations of these specimens ranged from 226 to 616 micrograms/L. Polypropylene and vacutainer tubes were used for storage. A Zeeman Graphite Furnace Atomic Absorption Spectrophotometer was used to determine the lead concentration. No loss of lead was found on the 12 specimens stored with heparin or EDTA at three different temperatures in all containers over the 10-week period. The variation of the lead concentration is comparable to the average precision of two quality control specimens, Tox-EL 1 and Tox-EL 2, of 7.4% and 6.1%. The use of the original vacutainer tubes with either heparin or EDTA and refrigerated temperature (4 degrees C) for the storage of human whole blood specimens for routine lead determination is recommended.

Anticoagulants↗