Search PubMed⌕ Search

Biomedical subjects

F Perret

Publications and source records attributed to F Perret.

At least 19 recordsLinked to original sources

Percutaneous closure of atrial septal defect type ostium secundum using the new Intrasept occluder: initial experience.

We report the first experience obtained with the new Intrasept device. We attempted to treat 35 patients with a mean age of 43 +/- 21 years. The mean size of the defect was 17/15 mm. It was successfully closed in 31 patients. In the remaining four the device could not be stabilized because of excessive defect size. A small residual shunt was present immediately following implantation in three patients. No complications occurred during the procedure and at 6 months, 31 patients had an uneventful outcome. Only one patient had a small residual shunt. No thrombus, embolization, or device fracture was documented during a mean follow-up of 17 +/- 11 months. Percutaneous closure of ASD ostium secundum is feasible with the Intrasept device with a high success rate and very good medium-term outcome. Our initial experience and results were excellent with small to medium size defects, however, large defects (>20 mm) remain challenging.

Adolescent↗

[Percutaneous closure of patent foramen ovale: preliminary experience with the PFO Star].

This article reports the experience of percutaneous closure of patent foramen ovale with the PFO Star device. Between January 2000 and December 2002, 44 consecutive patients with a mean age of 53 years were included in this registry. The implantation of the prosthesis was successful in 43 patients (98%): in 1 patient the atrial septum could not be crossed at operation. An early complication was observed in 3 patients (7%): one had transient amnesia and two patients had temporary ST elevation in the inferior ECG leads. Four patients (7%) had late complications: there was one case of spontaneously regressive atrial fibrillation, two recurrences of stroke (one in the patient without an implanted prosthesis and the other in a patient in whom the patent foramen ovale had been closed). Finally, one patient developed a fistula between the aorta and right atrium which occluded spontaneously when the anticoagulants were stopped. Complete closure of the patent foramen ovale was confirmed at 1 year in 92% of patients. The authors conclude that this preliminary experience shows that closure of patent foramen ovale with this device is effective and safe.

Adult↗

p-Sulfonatocalix[6]arene is an effective coacervator of poly(allylamine hydrochloride).

p-Sulfonatocalix[6]arene is shown to form insoluble complexes with poly(allylamine hydrochloride) when the charge balance between the negative calixarene sulfonate groups matches the positive charge carried by the polyelectrolyte, this makes this glycosylaminoglycan analog an interesting candidate for controlled release systems in the case of proteins encapsulated in mesoscopic complexes with polyelectrolytes.

Journal Article↗

Structural determination of zinc dithiophosphates in lubricating oils by gas chromatography-mass spectrometry with electron impact and electron-capture negative ion chemical ionization.

Pentafluorobenzyl ester derivatives were used to identify zinc dialkyldithiophosphates and diaryldithiophosphates antiwear engine oil additives by GC-electron impact ionization (EI) MS and GC-electron-capture negative ion chemical ionization (ECNCI) MS analysis. GC-EI-MS of the dialkyldithiophosphate-pentafluorobenzyl derivatives afforded characteristic fragment ions corresponding to the cleavage of one and two alkyl radicals. In most cases, information was only obtained on one alkyl chain. Additional and complete information was obtained with retention time indices using synthetic derivatives and with GC-ECNCI-MS analysis. ECNCI afforded characteristic dithiophosphate anions which allowed the determination of the total number of carbon atoms in the alkyl radicals. The diastereoisomer mixtures of 2-hydroxy-sec.-alkyl radicals were completely separated on GC analysis.

Gas Chromatography-Mass Spectrometry↗

High prevalence of peripheral atherosclerosis in a rapidly developing country.

Cardiovascular disease is rapidly increasing in developing countries experiencing epidemiological transition. We investigated the prevalence of peripheral atherosclerosis in a rapidly developing country and compared our findings with data previously reported in Western populations. A cardiovascular risk factor survey was conducted in 1067 individuals aged 25-64 randomly selected from the general population of Seychelles. High-resolution ultrasonography of the right and left carotid and femoral arteries was performed in a random subgroup of 503 subjects (245 men and 258 women). In each of the four arteries, arterial wall thickness (in plaque-free segments) and atherosclerotic plaques (i.e. focal wall thickening at least 1.0 mm thick) were measured separately. The prevalence of peripheral atherosclerosis was high in this population. For instance, at least one plaque > or =1.0 mm was found in, respectively, 34.9 and 27.5% of men and women aged 25-34 and at least one plaque > or =2.5 mm was found in, respectively, 58.2 and 36.9% of men and women aged 55-64. With reference to data found in the literature, the prevalence of carotid atherosclerosis appeared to be significantly higher in Seychelles than in Western populations. This study provides further evidence for the importance of cardiovascular disease in developing countries. Determinants should be identified and relevant prevention and control programs implemented.

Adult↗

Electrocardiographic findings in a middle-aged African population in the Seychelles islands.

This study describes major electrocardiogram (ECG) measurements and diagnoses in a population of African individuals; most reference data have been collected in Caucasian populations and evidence exists for interethnic differences in ECG findings. This study was conducted in the Seychelles islands (Indian Ocean) and included 709 black individuals (343 men and 366 women) aged 25 to 64 years randomly selected from the general population. Resting ECG were recorded by using a validated ECG unit equipped with a measurement and interpretation software (Cardiovit AT-6, Schiller, Switzerland). The epidemiology of 14 basic ECG measurements, 6 composite criteria for left ventricular hypertrophy and 19 specific ECG diagnoses including abnormal rhythms, conduction abnormalities, repolarization abnormalities, and myocardial infarction were examined. Substantial gender and age differences were found for several ECG parameters. Moreover, tracings recorded in African individuals of the Seychelles differed from those collected similarly in Caucasian populations in many respects. For instance, heart rate was approximately 5 beats per minute lower in the African individuals than in selected Caucasian populations, prevalence of first degree atrio-ventricular block was especially high (4.8%), and the average Sokolow-Lyon voltage was markedly higher in African individuals of the Seychelles compared with black and white Americans. The integrated interpretation software detected "old myocardial infarction" in 3.8% of men and 0% of women and "old myocardial infarction possible" in 6.1% and 3%, respectively. Cardiac infarction injury scores are also provided. In conclusion, the study provides reference values for ECG findings in a specific population of people of African descent and stresses the need to systematically consider gender, age, and ethnicity when interpreting ECG tracings in individuals.

Adult↗

[Retrospective multivariate analysis of radio-pathological correlations of nonpalpable breast lesions. Experience of the Hospital Saint-Louis].

PURPOSE: Several studies have demonstrated that systematic breast cancer screening increases overall survival. We report our experience regarding diagnosis of breast lesions detected using mammography. METHODS: Case reports of patients operated on in either 1992 or 1993 were retrospectively reviewed. A multivariate analysis of the clinico-pathological correlation was performed. RESULTS: Four hundred fifty seven patients representing on total 544 procedures, were included in the study. Mean age was 50.5 years (range 19-80 years). Most of the patients had no previous history of mammary lesion. Mammography was performed with prophylactic intent in more than 60% of the cases. Four hundred twelve (75.7%) benign lesions were diagnosed. Main lesions were: adenofibroma (15.7%), fibrocystic mastopathy (66.3%), adenosis (26.2%), ductal hyperplasia (23.9%), lobular hyperplasia (10.7%), and combined ductal and lobular hyperplasia (8.5%). Hyperplasia accompanied by cytonuclear atypia was observed in 49 (11%) cases. One hundred thirty two (24.3%) malignant lesions were reported, including 69 (52.3%) invasive carcinomas and 63 (47.7%) in situ carcinomas. Only nine axillary lymph node dissections were positive and 75 minimal breast cancers were diagnosed. The multivariate analysis showed that only radiological signs are a risk factor for cancer. The relative risk for cancer when focus of irregular and vermicular microcalcifications are diagnosed is 4.2 (2.0-8.5). It is 5.6 (2.5-12.5) in case of spiculated opacity. CONCLUSION: Exeresis following radiological prophylactic screening allows diagnosis of high-risk benign lesions and low-stage breast cancer. Radiological parameters are the most powerful predictive factors for malignancy.

Adult↗

Performance of classic electrocardiographic criteria for left ventricular hypertrophy in an African population.

ECG criteria for left ventricular hypertrophy (LVH) have been almost exclusively elaborated and calibrated in white populations. Because several interethnic differences in ECG characteristics have been found, the applicability of these criteria to African individuals remains to be demonstrated. We therefore investigated the performance of classic ECG criteria for LVH detection in an African population. Digitized 12-lead ECG tracings were obtained from 334 African individuals randomly selected from the general population of the Republic of Seychelles (Indian Ocean). Left ventricular mass was calculated with M-mode echocardiography and indexed to body height. LVH was defined by taking the 95th percentile of body height-indexed LVM values in a reference subgroup. In the entire study sample, 16 men and 15 women (prevalence 9.3%) were finally declared to have LVH, of whom 9 were of the reference subgroup. Sensitivity, specificity, accuracy, and positive and negative predictive values for LVH were calculated for 9 classic ECG criteria, and receiver operating characteristic curves were computed. We also generated a new composite time-voltage criterion with stepwise multiple linear regression: weighted time-voltage criterion=(0.2366R(aVL)+0.0551R(V5)+0.0785S(V3)+ 0.2993T(V1))xQRS duration. The Sokolow-Lyon criterion reached the highest sensitivity (61%) and the R(aVL) voltage criterion reached the highest specificity (97%) when evaluated at their traditional partition value. However, at a fixed specificity of 95%, the sensitivity of these 10 criteria ranged from 16% to 32%. Best accuracy was obtained with the R(aVL) voltage criterion and the new composite time-voltage criterion (89% for both). Positive and negative predictive values varied considerably depending on the concomitant presence of 3 clinical risk factors for LVH (hypertension, age >/=50 years, overweight). Median positive and negative predictive values of the 10 ECG criteria were 15% and 95%, respectively, for subjects with none or 1 of these risk factors compared with 63% and 76% for subjects with all of them. In conclusion, the performance of classic ECG criteria for LVH detection was largely disparate and appeared to be lower in this population of East African origin than in white subjects. A newly generated composite time-voltage criterion might provide improved performance. The predictive value of ECG criteria for LVH was considerably enhanced with the integration of information on concomitant clinical risk factors for LVH.

Adult↗

Time trends in the treatment of acute myocardial infarction in Switzerland from 1986 to 1993: do they reflect the advances in scientific evidence from clinical trials?

Three acute coronary care surveys (1986, 1990, and 1993) were conducted in the Swiss region of Vaud-Fribourg on all men aged 25 to 64 years hospitalized for a definite myocardial infarction (218, 224, and 167 cases). Nearly all patients received anticoagulants and nitrates. The proportion of patients treated increased significantly, between 1986 and 1990, for antiplatelet drugs (from 51% to 96%) and thrombolytics (from 9% to 44%) and, between 1990 and 1993, for beta-blockers (from 57% to 78%) and angiotensin-converting enzyme inhibitors (from 26% to 43%). The use of calcium antagonists and antiarrhythmics dropped over time. Coronary arteriography and angioplasty were increasingly performed (53% and 18% in 1993), although progressively postponed in-hospital stay. The observed trends reflect a rapid translation of clinical trials into medical practice. However the use of thrombolytics could be raised further by shortening the hospitalization delay (median: 3 hours in 1993) and door-to-needle time (median: 47 minutes) which remained stable over time.

Adrenergic beta-Antagonists↗

[Cardiac pacemaker dysfunction secondary to outside interference: a review].

Electromagnetic signals from various sources may cause interference with pacemakers. The safety systems developed by manufacturers are generally effective. Nevertheless, some electromagnetic sources, particularly those found in the medical environment, can induce transitory or permanent pacemaker dysfunction. This paper presents the various sources of electromagnetic signals to which a pacemaker may be exposed. Taking into account the available literature, it attempts to clarify those which are really deleterious for the pacemaker and how to avoid them.

Biophysical Phenomena↗

[Preliminary evaluation of the Profilomat, a new portable blood pressure recorder].

Ambulatory blood pressure monitoring is increasingly used in clinical evaluation of the hypertensive patient. The aim of the present study is to investigate the accuracy of non-invasive blood pressure measurements provided by the Profilomat, a new portable, automatic blood pressure recorder, in normotensive subjects and hypertensive patients. The results showed a good correlation between the blood pressure values measured by this apparatus and those determined simultaneously by the conventional auscultatory method (sphygmomanometer). Thus, the Profilomat appears to be a useful instrument for study of arterial blood pressure outside the doctor's office.

Adult↗

Conduit artery compliance and distensibility are not necessarily reduced in hypertension.

The goal of this study was to investigate whether the elastic behavior of conduit arteries of humans or rats is altered as a result of concomitant hypertension. Forearm arterial cross-sectional compliance-pressure curves were determined noninvasively by means of a high precision ultrasonic echo-tracking device coupled to a photoplethysmograph (Finapres system) allowing simultaneous arterial diameter and finger blood pressure monitoring. Seventeen newly diagnosed hypertensive patients with a humeral blood pressure of 163/103 +/- 4.4/2.2 mm Hg (mean +/- SEM) and 17 age- and sex-matched normotensive controls with a humeral blood pressure of 121/77 +/- 3.2/1.9 mm Hg were included in the study. Compliance-pressure curves were also established at the carotid artery of 16-week-old anesthetized spontaneously hypertensive rats (n = 14) as well as Wistar-Kyoto normotensive animals (n = 15) using the same echo-tracking device. In these animals, intra-arterial pressure was monitored in the contralateral carotid artery. Mean blood pressures averaged 197 +/- 4 and 140 +/- 3 mm Hg in the hypertensive and normotensive rats, respectively. Despite the considerable differences in blood pressure, the diameter-pressure and cross-sectional compliance-pressure and distensibility-pressure curves were not different when hypertensive patients or animals were compared with their respective controls. These results suggest that the elastic behavior of a medium size muscular artery (radial) in humans and of an elastic artery (carotid) in rats is not necessarily altered by an increase in blood pressure.

Animals↗

Non-invasive determination of arterial diameter and distensibility by echo-tracking techniques in hypertension.

METHODOLOGY: A new non-invasive ultrasonic device was developed to characterize the biomechanical properties of medium and large peripheral arteries. Simultaneous recordings of internal diameter and blood pressure over the whole cardiac cycle are used to establish compliance-pressure curves. Since blood pressure, which is an inherent co-determinant of arterial compliance, is taken into account, the comparison of arteries from patients with markedly different blood pressures has become possible. In a first study, the effects of three different antihypertensive drugs (20 mg lisinopril, 100 mg atenolol, 20 mg nitrendipine administered once a day) on arterial compliance and distensibility were investigated in young healthy volunteers. RESULTS: After 8 days of treatment, lisinopril induced a significant increase in arterial compliance. Subsequently, we compared the mechanical behaviour of arteries from newly diagnosed hypertensive patients (radial artery) or the carotid artery from spontaneously hypertensive rats (SHR) with that of corresponding arteries in normotensive counterparts. No decrease in arterial distensibility was found in the hypertensive groups over the measured blood pressure range. This result is not totally consistent with previous in vitro or in situ localized studies. Methodological differences, the absence of blood flow and/or denervation may partly explain these contradictory results. Finally, we tested the effects of hydralazine (5 mg/day) and captopril (25 mg/day), administered for 6 weeks in drinking water, on the behaviour of the carotid arteries of 16-week-old SHR. The two drugs effectively reduced blood pressure while shifting the distensibility-pressure curves upward in comparison to the placebo-treated animals, suggesting an improvement in arterial compliance. CONCLUSIONS: While hypertension does not itself appear to alter the elastic behaviour of large peripheral arteries, antihypertensive treatment may increase the compliance of these blood vessels.

Adult↗

Effects of SCH 34826, an orally active inhibitor of atrial natriuretic peptide degradation, in healthy volunteers.

Atrial natriuretic peptide is cleared from plasma by clearance receptors and by enzymatic degradation by way of a neutral metalloendopeptidase. Inhibition of neutral metalloendopeptidase activity appears to provide an interesting approach to interfere with metabolism of atrial natriuretic peptide to enhance the renal and haemodynamic effects of endogenous atrial natriuretic peptide. In this study, the effects of SCH 34826, a new orally active neutral metalloendopeptidase inhibitor, have been evaluated in a single-blind, placebo-controlled study involving eight healthy volunteers who had maintained a high sodium intake for 5 days. SCH 34826 had no effect on blood pressure or heart rate in these normotensive subjects. SCH 34826 promoted significant increases in excretion of urinary sodium, phosphate, and calcium. The cumulative 5-hour urinary sodium excretion was 15.7 +/- 7.3 mmol for the placebo and 22.9 +/- 5, 26.7 +/- 6 (p less than 0.05), and 30.9 +/- 6.8 mmol (p less than 0.01) for the 400, 800, and 1600 mg SCH 34826 doses, respectively. During the same time interval, the cumulative urinary phosphate excretion increased by 0.3 +/- 0.4 mmol after placebo and by 1.5 +/- 0.3 (p less than 0.01), 1.95 +/- 0.3 (p less than 0.01), and 2.4 +/- 0.4 mmol (p less than 0.001) after 400, 800, and 1600 mg SCH 34826, respectively. There was no change in diuresis or excretion of urinary potassium and uric acid. The natriuretic response to SCH 34826 occurred in the absence of any change in plasma atrial natriuretic peptide levels but was associated with a dose-dependent elevation of urinary atrial natriuretic peptide and cyclic guanosine monophosphate.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance↗

Non-invasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurements.

The non-linear elastic response of arteries implies that their mechanical properties depend strongly on blood pressure. Thus, dynamic measurements of both the diameter and pressure curves over the whole cardiac cycle are necessary to characterise properly the elastic behaviour of an artery. We propose a novel method of estimating these mechanical properties based on the analysis of the arterial diameter against pressure curves derived from ultrasonic and photoplethysmographic measurements. An ultrasonic echo tracking device has been developed that allows continuous recording of the internal diameter of peripheral arteries. It measures the diameter 300 times per second with a resolution of 2.5 microns. This system is linked to a commercially available light-plethysmograph which continuously records the finger arterial pressure (0.25 kPa accuracy). Because of the finite pulse wave velocity, the separation between the diameter and the pressure measurement sites causes a hysteresis to appear in the recorded diameter-pressure curve. Using a model based on haemodynamic considerations, the delay between the diameter variations and the finger arterial pressure is first eliminated. As the pulse wave velocity depends on the pressure, the delay is determined for each pressure value. The relationship between pressure and diameter is then described by a non-linear mathematical expression with three parameters, which best fits the recorded data. The dynamic local behaviour of the vessel is fully characterised by these parameters. Compliance, distensibility and pulse wave velocity can then be calculated at each pressure level. Thus, the mechanical behaviour of peripheral human arteries can now be characterised non-invasively over the pressure range of the whole cardiac cycle. The results obtained in vivo on human radial and brachial arteries show that a thorough analysis of the compliance-pressure curves and their modifications (curving, shift) is needed in order to compare two different vessels in a meaningful way.

Adult↗