Fetal abdominal wall mass detected on prenatal sonography: gastroschisis vs omphalocele.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to F N Tessler.
Explore the source record for details and available documents.
To determine the variability of pulsed Doppler peak velocity measurements, four radiologists with differing experience were tested using a calibrated flow phantom. Two ultrasound units, three probes and eight velocity rates varying between 40.5 and 78 cm/sec were studied, with a total of 303 measurements. The results were normalized against a set of 106 separate measurements made under highly-controlled conditions. The residual error standard deviation (not attributable to any systematically varied factor, including the velocity rate) was 6.8 cm/sec, with most of the remaining variation due to changing transducer or machine. Observer/equipment interactions accounted for 15.8% of the observed variability. The duration of the radiologist's Doppler experience had no significant effect.
A disconcertingly wide variation exists in the literature as to the accuracy of duplex Doppler sonography in the detection of acute renal transplant rejection. Sensitivities range from 9% to 76%. In an attempt to explain the disparity of results, we undertook a double-blind prospective study of the accuracy of duplex Doppler ultrasound in the detection of acute rejection in renal transplants. We scanned 49 consecutive patients with a total of 65 biopsies; 46 biopsies in 33 consecutive patients were included in our study. In our population, the prevalence of acute rejection was 61% (28/46). Using a resistive index (RI) cutoff of greater than 0.90 based on the main renal artery flow pattern, the sensitivity of our test was 43%, with a 67% specificity. The positive predictive value was 67%. Our results are contrasted and compared with the published data from other groups in a critical survey of the literature. We conclude that duplex Doppler sonography alone is inadequate to evaluate acute rejection in renal transplants.
To better understand portal vein pulsatility in congestive heart failure, the authors compared portal vein spectral patterns to right atrial pressures measured with a Swan-Ganz catheter in 17 adult patients suspected of having congestive heart failure. Portal vein pulsatility was also evaluated in 17 healthy adults. A pulsatility score (scale, 1-5) based on a ratio of minimum to peak portal vein velocity was assigned. A score of 1 indicated continuous, monophasic flow, while a score of 5 indicated that flow reversal was observed with each cardiac cycle. All 17 healthy volunteers had portal vein pulsatility scores of 2 or less. Among the 17 patients suspected of having congestive heart failure, seven had normal right atrial pressure (less than 10 mm Hg) and pulsatility scores of 2 or less. Among the 10 patients with a right atrial pressure of 10 mm Hg or greater, six had pulsatility scores of 3 or greater (sensitivity, 60%; specificity, 100%). Greater than 50% of the variation in portal vein score is explained by changes in right atrial pressure. Review of echocardiograms in 13 of 17 patients showed no significant correlation between the degree of tricuspid regurgitation and portal vein score. Portal vein pulsatility is a sign of elevated systemic venous pressure.
This study was designed to investigate the utility of color Doppler sonography in the evaluation of portosystemic shunts. Thirty-one patients with a total of 32 shunts were imaged. The types of shunts examined included portacaval, five; mesocaval, eight; distal splenorenal (Warren), 14; and mesoatrial, five. Sonography was performed without knowledge of the status of the shunt, although the type of shunt was known before beginning the study. The sonographic studies were evaluated to determine their sensitivity and specificity on the basis of a prospective comparison with angiography or MR imaging (22 cases). The possible advantages of color Doppler over duplex Doppler sonography in evaluating portosystemic shunts were also investigated, as was the ability of color Doppler sonography to image specifically the shunt anastomoses. Color Doppler sonography successfully inferred shunt patency (17 cases) or thrombosis (five cases) in all 22 shunts for which correlative imaging was available (sensitivity = 100%, specificity = 100%). In comparing duplex with color Doppler sonography in all 32 shunts, the two techniques were almost equally effective in establishing patency in portacaval, mesocaval, and mesoatrial shunts. Duplex Doppler sonography, however, provided useful diagnostic information in only four of 14 splenorenal shunts. Color Doppler correctly inferred patency or thrombosis in all 14. Among all 32 shunts, the anastomosis was shown clearly by color Doppler in 23, probably in four, and not all in five. Our results suggest that color Doppler sonography is an excellent method for the evaluation of all varieties of surgically created portosystemic shunts. In particular, color Doppler sonography appears to be superior to duplex Doppler sonography in imaging splenorenal communications.
This study was undertaken to assess the significance of diastolic flow reversal seen on duplex Doppler sonograms of patients with renal transplant dysfunction. Earlier studies have evaluated the causes of increased vascular resistance in renal transplants. None, however, have investigated specifically the subset of patients in whom impedance in the renal microcirculation has increased to the degree that retrograde arterial flow is present. In our series, 533 consecutive scans in 270 patients were reviewed. The patients were referred for evaluation of renal transplant dysfunction during a 25-month period. Doppler samples were obtained from main, segmental, and, when possible, arcuate arteries. An episode of reversed diastolic flow was identified in nine patients. Correlation was made with clinical, laboratory, histologic (biopsy in six patients, nephrectomy in three patients), and imaging studies (DTPA scintigraphy in seven patients, angiography in one patient). On the basis of histologic and nephrectomy results, we determined that among the nine patients, four had acute tubular necrosis, three had acute rejection, and two had renal vein thrombosis. One of these patients had both severe rejection and renal vein thrombosis. One additional patient had neither biopsy nor nephrectomy and was not included in the diagnostic groups listed here. Our study suggests that reversed diastolic flow is not specific for either acute rejection or acute tubular necrosis. Reversal of diastolic flow, however, is a poor prognostic sign; nephrectomy was imminent in three of the nine patients. Furthermore, two (22%) patients had renal vein thrombosis, whereas renal vein thrombosis was not found in any of the 261 patients without reversed diastolic flow. Duplex Doppler examinations with reversed diastolic flow should suggest renal vein thrombosis.
Transabdominal and endovaginal pelvic sonograms were obtained in 108 nonpregnant patients referred for pelvic sonography. The studies were independently obtained by two radiologists and interpreted on the basis of identical clinical information. The sonograms were then compared for anatomic detail and abnormalities. A determination was made about which examination, if either, was superior. Follow-up was performed through a review of the medical records and follow-up studies. Overall, the endovaginal study was judged superior in 65 cases (60.2%), equal in 39 (36.1%), and inferior in four (3.7%). The authors conclude that the endovaginal examination can effectively replace the transabdominal examination as the initial approach for routine pelvic sonography.
The frequency responses of nine real-time mechanical probes and two pulsed Doppler probes from four manufacturers were measured. The reflected frequency was measured in a clinical environment by evaluating the pulser, transducer assembly, and receiver as a system. Two independent systems were used for these measurements: a spectrum analyzer and a data acquisition system that computed the fast Fourier transform of the reflected waveform. Results showed that probe frequency (calibrated by the manufacturer in the transmit mode with a hydrophone) was as much as 30% higher than that found by means of frequency measurement procedures with the probe attached to the ultrasound system and evaluated in the receive mode. Such large discrepancies indicate that if acceptance testing of the frequency spectrum is not performed at a clinical facility, prolonged clinical evaluation of new equipment should be arranged.
This study was designed to evaluate duplex and color-flow Doppler imaging as potential noninvasive methods of diagnosing patients with Budd-Chiari syndrome and following them after surgery. Five patients with confirmed hepatic venoocclusive disease were imaged. All five underwent duplex Doppler examinations; three were also evaluated with color-flow Doppler. The hepatic vasculature was examined in all five patients; decompressive mesoatrial shunts were present and were evaluated in four of the five patients. Color-flow Doppler precisely defined intrahepatic, portal, and inferior vena caval circulatory dynamics. Correlation with angiography was excellent. In the two patients in whom hepatic vasculature was evaluated with duplex Doppler alone, the results were less impressive. Intrahepatic flow abnormalities were identified, but the sites of occlusion were not determined convincingly. Signals transmitted from the heart and the inability to visualize the hepatic veins made duplex Doppler evaluation problematic. Duplex Doppler was able to define patency and the direction of flow in the portal vein and inferior vena cava. Our results suggest that color-flow Doppler is an excellent technique for the initial evaluation of patients suspected of having Budd-Chiari syndrome. In the evaluation of decompressive mesoatrial shunts, color-flow Doppler produced dramatic images. However, both duplex and color-flow Doppler were highly accurate in determining the patency of decompressive shunts. Either duplex or color-flow Doppler may be used as the primary imaging procedure to determine shunt patency.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Twelve cases of fallopian tube dilatation were diagnosed in 10 patient by using endovaginal sonography. The diagnosis was confirmed by surgery in seven patients and by hysterosalpingography in three. A tubular shape was present in every case. Other sonographic features included a well-defined echogenic wall, a folded configuration, and linear echoes protruding into the tube lumen. Dilated tubes were distinguished from bowel loops by a lack of peristaltic activity and from pelvic veins by a lack of moving low-level echoes on real-time sonography. We conclude that the findings of dilated fallopian tubes on endovaginal sonography are sufficiently characteristic to allow the diagnosis to be made with this technique.
Five neonates with cranial arteriovenous malformations were studied with color Doppler sonography. Excellent correlation was found between sonography and subsequent angiography. In three patients with vein of Galen aneurysms, sonography showed a cystic structure with rapid or swirling flow. Careful adjustment of the color Doppler system was required to demonstrate flow in another patient with a dural arteriovenous malformation. An arteriovenous fistula in a fifth patient appeared as an area of increased flow. Arterial feeders and major draining veins were visualized in all five patients. Color Doppler imaging also was used to assess the effect of embolic or operative therapy in three of the patients. We conclude that color Doppler sonography is able reliably to characterize flow patterns in neonatal cranial arteriovenous malformations. Color Doppler imaging also is helpful in assessing flow after embolic or surgical therapy.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.