Effect of pacing site on the atrial electrogram at target sites for slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

Atrial electrograms recorded from target sites during radiofrequency catheter ablation of the slow atrioventricular (AV) nodal pathway are often fractionated and may be associated with a late, high frequency component (the slow pathway potential). The purpose of the current study was to assess the effects of slow pathway ablation on the morphology of the atrial electrogram and to determine whether target site electrograms display direction dependent changes in morphology during atrial pacing maneuvers. Twenty-six patients with typical AV nodal reentry had electrograms recorded from target sites before and after successful ablation of the slow AV nodal pathway and during pacing from the high right atrium and distal coronary sinus at cycle lengths of 500 and 300 msec. There was no significant change in the duration or degree of fractionation of the atrial electrogram as the result of slow pathway ablation. In contrast, the duration and degree of fractionation were less when pacing from the coronary sinus compared with sinus rhythms or right atrial pacing. Pacing rate did not affect electrogram morphology. These data suggest that the morphology of the slow pathway target site electrogram is dependent on the direction of atrial activation and that the "slow pathway potential" does not represent activation of an anatomically discrete pathway.

Adult↗

Site of accessory pathway block after radiofrequency catheter ablation in patients with the Wolff-Parkinson-White syndrome.

INTRODUCTION: Recent studies have demonstrated that the most common site of accessory pathway conduction block following the introduction of a premature atrial stimulus during atrial pacing is between the accessory pathway potential and the ventricular electrogram, consistent with block at the ventricular insertion of the accessory pathway. However, no prior study has evaluated the site of conduction block during radiofrequency catheter ablation procedures. Therefore, the objective of this study was to determine the site of conduction block after catheter ablation of accessory pathways by analyzing and comparing the local electrograms recorded before and after radiofrequency energy delivery at successful ablation sites. METHODS AND RESULTS: The electrograms evaluated in this study were obtained from 85 consecutive patients who underwent successful radiofrequency catheter ablation of a manifest accessory pathway. The 50 left free-wall accessory pathways were ablated using a ventricular approach and the 35 right free-wall or posteroseptal accessory pathways were ablated using an atrial approach. The characteristics of local electrograms recorded immediately before and immediately after successful ablation of the accessory pathway were determined in each patient. The site of accessory pathway block was determined by comparing the amplitude, timing, and morphology of the local electrograms at successful sites of radiofrequency catheter ablation before and after delivery of radiofrequency energy. A putative accessory pathway potential was present at the successful target site in 74 of the 85 patients (87%). Conduction block occurred between the atrial electrogram and the accessory pathway potential in 66 patients (78%) and between the accessory pathway potential and the ventricular electrogram in eight patients (9%). The site of block could not be determined in 11 patients (13%) in whom an accessory pathway potential was absent. Conduction block occurred most frequently between the atrial electrogram and the accessory pathway potential regardless of accessory pathway location. No electrogram parameter or accessory pathway characteristic was predictive of the site of conduction block. CONCLUSION: The results of this study demonstrate that conduction block occurs most frequently between the local atrial electrogram and the accessory pathway potential during radiofrequency catheter ablation of accessory pathways. This is true regardless of whether the accessory pathway is ablated from the atrial or ventricular aspect of the mitral or tricuspid annulus.

Adolescent↗

Effects of partial and complete ablation of the slow pathway on fast pathway properties in patients with atrioventricular nodal reentrant tachycardia.

INTRODUCTION: The purpose of this study was to prospectively compare the effects of complete and partial ablation of slow pathway function on the fast pathway effective refractory period (ERP). METHODS AND RESULTS: The subjects were 20 patients (mean age 43 +/- 13 years) with atrioventricular nodal reentrant tachycardia (AVNRT), no structural heart disease, and easily inducible AVNRT. Autonomic blockade was achieved with propranolol (0.2 mg/kg) and atropine (0.04 mg/kg). After elimination of AVNRT and during autonomic blockade, the presence of residual slow pathway function was determined by the presence of a single AV nodal echo and/or dual AV nodal physiology. After autonomic blockade and before ablation, the mean fast pathway ERP was 319 +/- 44 msec and the mean slow pathway ERP was 251 +/- 31 msec. After slow pathway ablation and during autonomic blockade, 7 patients had residual slow pathway function and 13 did not. Complete loss of slow pathway function was associated with a shortening of the fast pathway ERP from 334 +/- 35 msec to 300 +/- 62 msec (P < 0.01), while the fast pathway ERP did not change significantly in patients with residual slow pathway function (291 +/- 29 msec vs 303 +/- 38 msec, respectively; P = 0.08). A shortening of 30 msec or more in the fast pathway ERP was observed in 11 of 13 patients who did not have residual slow pathway function, compared to 0 of 7 patients with residual slow pathway function (P < 0.001). CONCLUSION: Shortening of the fast pathway ERP after successful ablation of AVNRT is dependent upon complete loss of slow pathway function. This observation is consistent with electrotonic inhibition of the fast pathway by the slow pathway.

Adult↗

Transvenous and subcutaneous implantable cardioverter defibrillators: radiographic assessment.

PURPOSE: To assess chest radiograph configurations in 102 patients following total or partial transvenous and subcutaneous insertion of a non-thoracotomy lead implantable cardioverter defibrillator (NTL-ICD) device. MATERIALS AND METHODS: The four overlapping system types reviewed were the Endotak (49 patients), PCD (32 patients), Res-Q (10 patients), and hybrid combinations of NTL-ICD and surgically inserted pericardial and epicardial automatic implantable cardioverter defibrillator (AICD) devices (15 patients). RESULTS: Abnormalities were detected on radiographs both at the time of implantation and at early follow-up. NTL-ICD electrodes partially replaced or augmented AICD systems in 11 patients (10.7%) because of sensing lead or defibrillation failure or infection. Defibrillation failure necessitated augmentation of NTL-ICD systems with AICD pericardial patches in four patients (3.9%). Catheter displacement, lead fracture, or pneumothorax was detected in eight patients (7.8%). CONCLUSION: Complex radiographic appearances may be seen and important abnormalities may be detected after insertion of these devices.

Defibrillators, Implantable↗

Analysis of junctional ectopy during radiofrequency ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia.

BACKGROUND: Junctional ectopy may occur during radiofrequency (RF) catheter ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia (AVNRT). The purpose of the present study was to characterize this junctional ectopy quantitatively. METHODS AND RESULTS: The subjects of this study were 52 consecutive patients with AVNRT who underwent slow pathway ablation and 5 additional patients included retrospectively because they had developed high-degree atrioventricular (AV) block during the procedure. A combined anatomic and electrogram mapping approach was used for slow pathway ablation, and AVNRT was successfully eliminated in all patients. In the group of 52 consecutive patients, the incidence of junctional ectopy was significantly higher during 52 effective applications of RF energy than during 366 ineffective applications (100% versus 65%, P < .001). Compared with ineffective RF energy applications, successful RF energy applications had a significantly longer duration of individual bursts of junctional ectopy (7.1 +/- 7.1 versus 5.0 +/- 7.0 seconds [+/- SD], P < .05), a greater total number of junctional beats during the applications (24 +/- 16 versus 15 +/- 8, P < .01), and a greater total span of time during which junctional ectopy occurred (19 +/- 15 versus 11 +/- 12 seconds, P < .01). Four of the 52 patients plus an additional 5 patients developed transient AV block lasting 34 +/- 37 seconds. In 1 of the 9 patients who had transient AV block, third-degree AV nodal block requiring a permanent pacemaker recurred 2 weeks later. In each of the 9 patients who developed AV block, there was ventriculoatrial (VA) block in association with junctional ectopy during the RF energy application immediately preceding the AV block. Among 48 patients who did not develop AV block, 17 patients had at least one episode of VA block during junctional ectopy. The positive predictive value of VA block during junctional ectopy for the development of AV block was 19% in the consecutive series of 52 patients. Among 31 patients who always had 1:1 VA conduction in association with junctional ectopy, 12 had poor VA conduction in the baseline state, with a VA block cycle length of at least 500 milliseconds during ventricular pacing. CONCLUSIONS: In patients with AVNRT undergoing slow pathway ablation, junctional ectopy during the application of RF energy is a sensitive but nonspecific marker of successful ablation. The bursts of junctional ectopy are significantly longer at effective target sites than at ineffective sites. VA conduction should be expected during the junctional ectopy that accompanies slow pathway ablation, even when there is poor VA conduction during baseline ventricular pacing. VA block during junctional ectopy is a harbinger of AV block in patients undergoing RF ablation of the slow pathway. If energy applications are discontinued as soon as VA block occurs, the risk of AV block may be markedly reduced.

Adolescent↗

Results and efficiency of programmed ventricular stimulation with four extrastimuli compared with one, two, and three extrastimuli.

BACKGROUND: Conventional programmed ventricular stimulation protocols are inefficient compared with more recently proposed protocols. The purpose of the present study was to determine if additional efficiency could be derived from a 6-step programmed ventricular stimulation protocol that exclusively uses four extrastimuli. METHODS AND RESULTS: The subjects were 209 consecutive patients with coronary artery disease and documented sustained monomorphic ventricular tachycardia, nonsustained ventricular tachycardia, aborted sudden death, or syncope. These patients underwent 159 electrophysiological tests in the absence of antiarrhythmic drug therapy and 105 electrophysiological tests in the presence of antiarrhythmic therapy. Programmed stimulation was performed with two protocols in random order in each patient. Both protocols used an eight-beat drive train, 4-s intertrain pause, and basic drive cycle lengths of 350, 400, and 600 ms. The 6-step protocol started with coupling intervals of 290, 280, 270, and 260 ms, which were shortened simultaneously in 10-ms steps until S2 was refractory. The 18-step protocol used one, two and three extrastimuli in conventional sequential fashion. The end points were 30 s of sustained monomorphic ventricular tachycardia, two episodes of polymorphic ventricular tachycardia requiring cardioversion, or completion of the protocol at two right ventricular sites. There was no significant difference in the yield of sustained monomorphic ventricular tachycardia using the two protocols, regardless of the clinical presentation or treatment with antiarrhythmic drugs. Polymorphic ventricular tachycardia occurred with the 18-step protocol twice as frequently as with the 6-step protocol (6% versus 3%, P < .001). The duration of the 18-step protocol was significantly longer than that of the 6-step protocol in patients with inducible ventricular tachycardia (5.5 +/- 7 versus 2.3 +/- 2 minutes, P < .001), as well as in patients without inducible ventricular tachycardia (25.4 +/- 7 versus 6.9 +/- 2 minutes, P < .001). CONCLUSION: A stimulation protocol that exclusively uses four extrastimuli improves the specificity and efficiency of programmed ventricular stimulation without compromising the yield of monomorphic ventricular tachycardia in patients with coronary artery disease.

Aged↗

A randomized comparison of the right- and left-sided approaches to ablation of the atrioventricular junction.

Radiofrequency ablation of the atrioventricular (AV) junction may be performed using either a right- or left-sided approach. This study prospectively compared the left-sided approach with persistent attempts from the right side in patients in whom initial radiofrequency applications on the right side were unsuccessful. Twenty-one of 54 patients did not have complete AV block induced after 3 right-sided radiofrequency applications. These 21 patients were randomly assigned to undergo either the left-sided approach (n = 10) or to undergo additional attempts from the right side (n = 11). The right-sided approach was performed by positioning the ablation catheter to record the largest possible atrial and His bundle electrograms. The left-sided approach was performed by positioning the ablation catheter along the left ventricular septum, where a His bundle potential was recorded. If either approach was not successful after an additional 17 radiofrequency applications, the alternative approach was then used. The AV junction was successfully ablated in all 10 patients randomized to the left-sided approach, but in only 6 of 11 patients randomized to persistent right-sided attempts (p < 0.05). The 5 patients in whom the AV junction was not successfully ablated using the right-sided approach underwent the left-sided approach and had a successful outcome after a mean of 1.2 +/- 0.4 radiofrequency applications. The left-sided approach required significantly fewer radiofrequency applications after randomization than the right-sided approach (3 +/- 3.4 vs 11 +/- 7.6, p < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Prospective, randomized comparison of conventional and high dose loading regimens of amiodarone in the treatment of ventricular tachycardia.

OBJECTIVES: The purpose of this prospective randomized study was to compare the electrophysiologic effects of conventional and high dose loading regimens of amiodarone in patients with sustained ventricular tachycardia. BACKGROUND: Uncontrolled studies in which patients have been treated with an oral loading dose of 2 to 4 g/day of amiodarone have suggested that, compared with a conventional loading dose, this dosing regimen results in more rapid control of spontaneous ventricular tachycardia and ventricular tachycardia induced by programmed stimulation. METHODS: Patients in whom sustained monomorphic ventricular tachycardia was inducible by programmed stimulation and who were refractory to class I antiarrhythmic medications were randomly assigned to receive either a conventional (n = 15) or a high (n = 17) loading dose of amiodarone. The conventional dose consisted of 600 mg twice a day for 10 days. The high dose regimen consisted of 50 mg/kg body weight per day on days 1 to 3, 30 mg/kg per day on days 4 and 5 and 600 mg twice a day on days 6 to 10. An electrophysiologic test was performed in the baseline state and after 3 and 10 days of therapy. An adequate response to amiodarone was defined as the inability to induce ventricular tachycardia or the ability to induce only relatively slow (cycle length > or = 350 ms) hemodynamically stable ventricular tachycardia. RESULTS: After 3 days of therapy, 2 of 14 patients who received the conventional loading dose and 6 of 15 patients who received the high dose loading regimen had an adequate response to amiodarone (p = 0.08). After 10 days of therapy, four patients in each group had an adequate response to amiodarone (p = NS). Three patients who received the high dose and one patient who received the conventional dose of amiodarone had an adequate response after 3 days of therapy but not after 10 days of therapy. There were significant increases in the sinus cycle length, atrioventricular block cycle length, ventricular effective refractory period and ventricular tachycardia cycle length after 3 and 10 days of therapy compared with baseline values regardless of the dosing regimen. The extent of the effects of amiodarone on these variables after 3 and 10 days of therapy was similar with both dosing regimens. CONCLUSIONS: The therapeutic and electrophysiologic effects of conventional and high dose loading regimens of amiodarone do not differ significantly after 3 or 10 days of therapy. High oral loading doses of amiodarone do not offer any significant clinical advantage over a conventional loading dose of amiodarone for controlling ventricular tachycardia induced by programmed stimulation.

Aged↗

Relation between efficacy of radiofrequency catheter ablation and site of origin of idiopathic ventricular tachycardia.

The results of radiofrequency catheter ablation of ventricular tachycardia (VT) in patients without structural heart disease are reported. Particular attention was focused on the relation between efficacy and the site of origin of the VT. Eighteen consecutive patients (5 women and 13 men; mean age 41 +/- 13 years) with idiopathic VT underwent catheter ablation using radiofrequency energy. Sites for radiofrequency energy delivery were selected on the basis of pace mapping. A follow-up electrophysiologic test was performed 1 to 3 months after the ablation procedure. Twenty VTs were induced. Radiofrequency catheter ablation was successful in eliminating all 10 VTs originating from the right ventricular outflow tract, and 5 of 10 from other sites in the left or right ventricle. There were no complications. The duration of ablation sessions was shorter, the frequency of identifying a site resulting in an identical pace map was higher, and the efficacy of catheter ablation was greater for VTs originating from the right ventricular outflow tract than for those from other locations. The results of this study demonstrate that radiofrequency catheter ablation of idiopathic VT is safe and effective. The efficacy of the procedure is dependent on the site of origin of the VT, with the efficacy being greater for VTs originating from the outflow tract of the right ventricle than for those from other locations.

Adult↗

Safety, feasibility and cost of outpatient radiofrequency catheter ablation of accessory atrioventricular connections.

OBJECTIVES: The purpose of this study was to evaluate prospectively the safety, feasibility and cost of performing radiofrequency catheter ablation of accessory atrioventricular (AV) connections on an outpatient basis in 137 cases. BACKGROUND: The efficacy and low complication rate of radiofrequency ablation as performed in the hospital suggested that it might be feasible to perform it on an outpatient basis. METHODS: In 100 cases (73%) performed between September 1, 1991 and April 20, 1992, patients met criteria for treatment as outpatients. Reasons for exclusion were age < 13 or > 70 years (4), anteroseptal location of the accessory AV connection (5 patients), obesity (> 30% of ideal body weight) (4 patients) or clinical indication for hospitalization (24 patients). Patients with only venous punctures had a recovery period of 3 h and those with arterial punctures had a recovery period of 6 h. There were 63 men and 32 women (5 patients underwent two ablation procedures > 1 month apart), with a mean age +/- SD of 36 +/- 13 years. The pathway was left-sided in 67 cases and right-sided or posteroseptal in 33. RESULTS: The procedure was successful in 97 of 100 cases, with a mean procedure duration of 99 +/- 42 min. In 70 cases the patient was discharged the day of ablation, and in 30 cases the patient required a short (< or = 18-h) overnight stay because the procedure was completed too late in the day for recovery in the outpatient facility. The mean duration of observation was 4.8 +/- 1.5 h for outpatients and 15 +/- 1.4 h for patients who underwent overnight hospitalization. At follow-up study, two patients had a clinically significant complication; both had a femoral artery pseudoaneurysm detected > or = 1 week after the procedure and both required surgical repair. Thirty consecutive patients (22 outpatients and 8 hospitalized overnight) undergoing catheter ablation after January 1, 1992 were chosen for a cost analysis. The mean cost of the procedure was $10,183 +/- $1,082. CONCLUSIONS: The majority of patients undergoing radiofrequency catheter ablation of an accessory AV connection can be treated safely on an outpatient basis.

Adult↗

The economic burden of unrecognized vasodepressor syncope.

BACKGROUND: The objective of this study was to describe the cost of prior diagnostic evaluation in patients referred for evaluation of syncope whose history was typical of vasodepressor syncope. METHODS AND RESULTS: Thirty consecutive patients who were referred for evaluation of syncope of undetermined origin and whose history was highly suggestive of vasodepressor syncope participated in this study. These 30 patients represented 19% of 158 patients referred for evaluation of syncope during the period of enrollment. All patients had positive results of an upright-tilt test, confirming the diagnosis of vasodepressor syncope. At the time of evaluation, the type and results of all diagnostic tests that had been performed prior to referral were recorded for each patient. The cost of diagnostic testing was then determined based on the 1991 cost of these tests at the University of Michigan Medical Center. A mean of 4 +/- 2 major diagnostic tests were performed before referral to the University of Michigan Medical Center. The mean and median costs of diagnostic testing per patient prior to referral were $3,763 +/- 3,820 and $2,678 (range: 0 to $16,606) respectively. Six patients underwent no major diagnostic tests prior to referral and, therefore, the cost of major diagnostic testing was zero in these patients. In the remaining patients, the mean and median costs of diagnostic testing per patient were $4,704 +/- 3,713 and $3,777 (range: $1,025 to $16,606) respectively. CONCLUSIONS: The results of this study demonstrate that a diagnosis of vasodepressor syncope can be established clinically in approximately 20% of patients referred to a university hospital for evaluation of syncope of undetermined origin. Failure to recognize the clinical features of vasodepressor syncope in these patients resulted in up to $16,000 of unnecessary diagnostic testing. A greater awareness of the clinical features of vasodepressor syncope may, therefore, result in significant economic savings.

Adolescent↗

Recognition and catheter ablation of subepicardial accessory pathways.

OBJECTIVES: The purpose of this study was to characterize left-sided accessory pathways that traverse the atrioventricular (AV) groove subepicardially and to describe results of radiofrequency catheter ablation within the coronary sinus in the patients studied. BACKGROUND: Radiofrequency catheter ablation has proved to be a safe and effective method for treatment of accessory pathways; however, subepicardial accessory pathways may account for some of the failures encountered during endocardial ablation. METHODS: The study group comprised 51 consecutive patients with a left-sided accessory pathway who were undergoing radio-frequency catheter ablation. Initially, the ablation catheter was introduced into a femoral artery and positioned on the ventricular aspect of the mitral annulus. If this endocardial approach was unsuccessful, the ablation catheter was introduced into the coronary sinus and energy applied at sites with shorter activation times than those recorded from the endocardium. RESULTS: Five (10%) of 51 patients with a left-sided accessory pathway could not have accessory pathway conduction interrupted with a median of 18 endocardial radiofrequency energy applications. Accessory pathway potentials were less frequent during endocardial mapping in these 5 patients than in the 46 patients whose accessory pathway was successfully ablated from the endocardial surface. All five of these patients later had successful ablation using one or two applications of radiofrequency energy from within the coronary sinus. Effective target site electrograms in the coronary sinus were characterized by an accessory pathway potential that was larger than the corresponding atrial or ventricular electrogram. There were no complications or recurrences after ablation within the coronary sinus. CONCLUSIONS: Some left-sided accessory pathways may be difficult to ablate from the endocardial surface because they traverse the AV groove subepicardially. The absence of an accessory pathway potential during endocardial mapping in combination with a relatively large accessory pathway potential within the coronary sinus may be a useful marker of a subepicardial pathway. In this select group of patients, radiofrequency catheter ablation from within the coronary sinus appears to enhance efficacy.

Action Potentials↗

Differentiation of paroxysmal narrow QRS complex tachycardias using the 12-lead electrocardiogram.

OBJECTIVES: The purpose of this study was to evaluate the utility of the 12-lead electrocardiogram (ECG) for differentiating paroxysmal narrow QRS complex tachycardias. BACKGROUND: Previous studies evaluating the utility of the 12-lead ECG for differentiating paroxysmal supraventricular tachycardia types have shown conflicting results on the usefulness of some ECG criteria, and some criteria that are considered to be useful have never been formally evaluated. METHODS: Two hundred forty-two ECGs demonstrating paroxysmal narrow QRS complex (< 0.11 ms) tachycardia (rate > or = 120 beats/min) were analyzed. All ECGs were analyzed by an observer who had no knowledge of the mechanism of the tachycardia. RESULTS: There were 137 atrioventricular (AV) reciprocating tachycardias, 93 AV node reentrant tachycardias and 12 atrial tachycardias. Six criteria were found to be significantly different between tachycardia types by univariate analysis. A P wave separate from the QRS complex was observed more frequently in AV reciprocating tachycardia (68%) and atrial tachycardias (75%). A pseudo r' deflection in lead V1 and a pseudo S wave in the inferior leads were more common in AV node reentrant tachycardia (58% and 14%, respectively); QRS alternans was present more often during AV reciprocating tachycardia (27%). When a P wave was present, an RP/PR interval ratio > or = 1 was more common in atrial tachycardias (89%). During sinus rhythm, manifest pre-excitation was observed more often in patients with AV reciprocating tachycardia (45%). By multivariate analysis, the presence of a P wave separate from the QRS complex, pseudo r' deflection in lead V1, QRS alternans during tachycardia and the presence of pre-excitation during sinus rhythm were independent predictors of tachycardia type. These criteria correctly identified 86% of AV node reentrant tachycardias, 81% of AV reciprocating tachycardias and incorrectly assigned the tachycardia type in 19% of cases. CONCLUSIONS: Several features on the ECG are useful for differentiating supraventricular tachycardia type. However, approximately 20% of tachycardias may be incorrectly classified on the basis of analysis of the ECG; therefore, the ECG should not serve as the sole means for determining tachycardia mechanism.

Adolescent↗

A prospective randomized comparison of direct current and radiofrequency ablation of the atrioventricular junction.

OBJECTIVES: The purpose of this study was to compare direct current and radiofrequency ablation of the atrioventricular (AV) junction in a prospective randomized fashion. BACKGROUND: Catheter ablation of the AV junction can be performed using either direct current shocks or radiofrequency energy. To date, these two techniques have never been compared prospectively or in a randomized study. METHODS: Forty patients with drug-refractory uncontrolled atrial fibrillation-flutter (38 patients) or inappropriate sinus tachycardia (2 patients) were randomly assigned to undergo direct current ablation (20 patients) using up to four shocks of 200 to 300 J or radiofrequency ablation (20 patients) using up to 15 applications of 16 to 25 W for 30 s. If complete AV block was not successfully induced, the ablation procedure was repeated using the alternate type of energy. A rate-responsive ventricular pacemaker was implanted in each patient. The intrinsic escape rhythm was evaluated 15 min, 2 days and 3, 6 and 12 months after ablation. RESULTS: Persistent complete AV block was successfully induced during the first ablation session in 13 (65%) of 20 patients randomly assigned to undergo direct current ablation, compared with 19 (95%) of 20 patients randomly assigned to undergo radiofrequency ablation (p < 0.05). Each patient whose first ablation attempt failed had a successful outcome with the alternate type of energy. The overall efficacy of radiofrequency ablation (26 [96%] of 27 patients) was significantly greater than that of direct current ablation (14 [67%] of 21 patients, p < 0.01). The duration of the direct current and radiofrequency ablation sessions did not differ significantly. The mean peak plasma creatine kinase MB fraction concentration was significantly higher after direct current ablation (58 +/- 29 IU/liter) than after radiofrequency ablation (2 +/- 2 IU/liter) (p < 0.001). An escape rhythm was present 15 min after ablation in an equal proportion of patients undergoing direct current and radiofrequency ablation (78% and 85%, respectively, p = 0.6). An escape rhythm was present in all patients 3, 6 and 12 months after ablation. The mean escape rhythm cycle length 15 min after direct current ablation (2,074 +/- 677 ms) was significantly longer than that 15 min after radiofrequency ablation (1,460 +/- 294 ms) (p < 0.05); however, the mean escape rhythm cycle lengths did not differ significantly at 2 days or 3, 6 or 12 months after ablation. Immediate arrhythmic complications did not occur after either procedure. One patient died suddenly 6.5 months after direct current ablation. CONCLUSIONS: Radiofrequency ablation of the AV junction is more efficacious and safer than direct current ablation and should be the preferred method for inducing complete AV block in patients who are appropriate candidates for ablation of AV conduction.

Aged↗

Association between atrioventricular node reentrant tachycardia and inducible atrial flutter.

OBJECTIVES: The purpose of this study was to evaluate the inducibility of atrial flutter in patients with atrioventricular (AV) node reentrant tachycardia and to determine the effect of radio-frequency ablation of the slow AV node pathway on the inducibility of atrial flutter. BACKGROUND: Studies have shown that both AV node reentrant tachycardia and atrial flutter are reentrant arrhythmias having an area of slow conduction that is located in the low posterior right atrium near the ostium of the coronary sinus. METHODS: Ninety-one patients were prospectively evaluated using a standardized atrial pacing protocol. Three groups of patients were analyzed: 42 patients with inducible AV node reentrant tachycardia, 13 with a history of spontaneous atrial flutter and 36 control patients. A subgroup of 34 patients with AV node reentrant tachycardia who underwent successful radiofrequency ablation of the slow AV node pathway underwent atrial pacing again after ablation. RESULTS: Atrial flutter was more frequently inducible in patients with AV node reentrant tachycardia (88%) and in those with a history of atrial flutter (92%) than in control patients (36%) (p = 0.0001). There were no differences between the patient groups with respect to atrial effective refractory period, P wave duration or PA interval at the His position. Among the 34 patients with AV node reentrant tachycardia who underwent atrial pacing before and after radiofrequency ablation, there were 30 with atrial flutter and 4 with atrial fibrillation before ablation and 29 with atrial flutter and 5 with atrial fibrillation after ablation (p = NS). There was no difference in the duration of the induced atrial flutter before and after ablation. The mean atrial flutter cycle length before ablation (206 +/- 22 ms) was not different from that after ablation (196 +/- 20 ms) (p = NS). CONCLUSIONS: There is a strong association between AV node reentrant tachycardia and inducible atrial flutter, suggesting that there may be a common area of perinodal atrium participating in the two tachycardia circuits. However, radiofrequency ablation of the slow pathway of the AV node reentrant tachycardia circuit does not influence the inducibility of atrial flutter.

Adult↗

Interference from a hand held radiofrequency remote control causing discharge of an implantable defibrillator.

A 46-year-old man with a history of sustained monomorphic ventricular tachycardia underwent an implantation of a third generation multiprogrammable implantable cardioverter defibrillator. One year post implant, while manipulating a remote control to a radiofrequency modulated toy car, the patient experienced a defibrillator discharge not preceded by an arrhythmia prodrome. Subsequent interrogation of the defibrillator revealed that a 34-joule shock had been delivered and had been preceded by RR intervals ranging from 141-406 msec, consistent with sensing lead noise. The remote control utilizes a 12-volt battery and has a carrier frequency of 75.95 MHz and a modulating frequency of 50 Hz. Evaluation of the remote control and defibrillator interaction revealed that the remote control was able to trigger tachyarrhythmia sensing and reproduce the clinical episode. Interference was present only when the remote control was within 8 cm of the pulse generator and at specific angles relative to the device and only when the antenna length was > 45 cm. Interference was eliminated when a ground wire was attached to the antenna and when an aluminium shield was placed between the pulse generator and the remote control. This case report suggests that patients with third generation multiprogrammable defibrillators should be cautioned against close contact with potential sources of electromagnetic interference, such as remote control units.

Artifacts↗