Search PubMed⌕ Search

Biomedical subjects

F Kajiya

Publications and source records attributed to F Kajiya.

At least 37 records · Page 2Linked to original sources

Effects of size and shape (aspect ratio) on the hemodynamics of saccular aneurysms: a possible index for surgical treatment of intracranial aneurysms.

OBJECTIVE: The present study was undertaken to explore the relationship between the characteristic geometry of aneurysms prone to rupture and the blood flow patterns therein, using microsurgically produced aneurysms that simulated human middle cerebral artery aneurysms in scale and shape. METHODS: We measured in vivo velocity profiles using our 20-MHz, 80-channel, Doppler ultrasound velocimeter. We produced small (< or =5 mm, 5 cases) and large (6-13 mm, 12 cases) aneurysms with round, dumbbell, or multilobular shapes. RESULTS: The fundamental patterns of intra-aneurysmal flow were composed of inflow, circulating flow, and outflow. The inflow, which entered the aneurysm only during the systolic phase, was strongly influenced by the position and size of the neck and the flow ratio into the distal branches. The outflow was usually nonpulsatile and of low velocity. The circulating flow depended on the aspect ratio (depth/neck width). A single recirculation zone was observed in aneurysms with aspect ratios of less than 1.6. This circulation did not seem to extend to areas with aspect ratios greater than this value; in aneurysms with aspect ratios of more than 1.6, a much slower circulation was observed near the dome. Furthermore, in the dome of dumbbell-shaped aneurysms and daughter aneurysms, no flow was detected. Intra-aneurysmal flow was determined by the aspect ratio, rather than the aneurysm size. CONCLUSION: The localized, extremely low-flow condition that was observed in the dome of aneurysms with aspect ratios of more than 1.6 is a common flow characteristic in the geometry of ruptured aneurysms, so great care should be taken for patients with unruptured intracranial aneurysms with aspect ratios of more than 1.6.

Aneurysm, Ruptured↗

Transmural microcirculatory blood flow distribution in right and left ventricular free walls of rabbits.

Within-layer regional myocardial flows in the left and right ventricles (LV, RV) and in LV with increased myocardial workload (beta(1)-adrenoceptor stimulation) were studied transmurally in anesthetized rabbits. Myocardial flow distribution was visualized with resolutions between 0.1 x 0.1- and 1 x 1-mm(2) pixels, using digital radiography combined with the (3)H-labeled desmethylimipramine deposition technique. The spatial pattern of flow distribution was quantitated by the coefficient of variation of regional flows (CV, related to global flow heterogeneity) and the correlation between adjacent regional flows (CA, inversely related to local flow randomness). CV was lower in LV than in RV [P < 0.05, nonparametric 2-way analysis of variance (NANOVA)]. When resolution was lowered from 0.1 x 0.1- to 1 x 1-mm(2) pixels, CV decreased by 70% in both LV and RV. CA was higher in LV than in RV (P < 0.05, NANOVA); the interventricular difference in CA was large over the resolutions between 0.4 x 0.4- and 1 x 1-mm(2) pixels. In LV, both CV and CA increased with depth of myocardium (P < 0.05, NANOVA); in subendocardium CV was high comparable with CV in RV (P = 0.47, NANOVA). The enhancement of myocardial workload decreased CV and tended to decrease CA in LV subendocardium (P < 0.05, P = 0.06, respectively; NANOVA). We conclude that 1) microregional flow distribution is less heterogeneous and less random in LV than in RV; 2) transmurally, in LV subendocardium global flow heterogeneity was the highest whereas local flow randomness was the lowest, so that clusters of low- or high-flow regions exist in this LV layer; and 3) global flow heterogeneity decreased and local flow randomness tended to increase (flow homogenizing occurred) in LV subendocardium with increasing myocardial workload. Thus the distributed pattern of myocardial microregional flows may be adaptable to local myocardial metabolic change.

Animals↗

Role of NO and K(+)(ATP) channels in adenosine-induced vasodilation on in vivo canine subendocardial arterioles.

Adenosine (Ado) plays an important role in regulation of coronary vascular tone with nitric oxide (NO) and ATP-sensitive K(+) (K(+)(ATP)) channels. In vitro, it was reported that subendocardial (Endo) arterioles are more sensitive to Ado than subepicardial (Epi) arterioles. The purpose of this study was to observe enhanced vasodilation of Endo arterioles directly and to evaluate possible roles of K(+)(ATP) channels and NO in the different responses of Endo and Epi arterioles to Ado-induced vasodilation. We evaluated dilation of Endo and Epi arterioles (<120 micrometer) of beating canine hearts (n = 19) by Ado (20 and 50 microgram. kg(-1). min(-1) ic) before and after K(+)(ATP) channel blockade (glibenclamide; 200 microgram/kg ic), inhibition of NO synthase [N(G)-nitro-L-arginine methyl ester (L-NAME); 30 microgram. kg(-1). min(-1), 20 min ic], or glibenclamide + L-NAME using a novel needle-probe CCD intravital microscope. Ado induced dose-dependent vasodilation in both Epi and Endo arterioles, but vasodilation was greater in Endo arterioles, i.e., increase at 120 s (maximum dilation) after Ado (50 microgram. kg(-1). min(-1)) was 17% in Endo and 13% in Epi arterioles (P < 0.01). Endo arteriole dilation was attenuated by blockade of K(+)(ATP) channels from 18% (Ado) to 9% (Ado+glibenclamide) increase (P < 0.001) and by inhibition of NO synthase from 17% (Ado) to 9% (Ado+L-NAME) (P < 0.005). Epi arteriole vasodilation was attenuated by blockade of K(+)(ATP) channels from 15 to 9% (P < 0.005) and inhibition of NO from 16 to 10% (P < 0.005). Suppression of vascular response was additive (Endo, 14 to -1%; Epi, 12 to 3%) with glibenclamide + L-NAME. We conclude that 1) the degree of Ado-induced vasodilation was greater in Endo than in Epi arterioles, with higher sensitivity of smaller arterioles in both layers and 2) transmural difference of arteriolar sensitivity to adenosine was abolished or reversed by K(+)(ATP) channel blockade and/or by NO synthase inhibition, indicating crucial involvement of K(+)(ATP) and NO in transmural sensitivity difference.

Adenosine↗

Zonal heterogeneity in action of angiotensin-converting enzyme inhibitor on renal microcirculation: role of intrarenal bradykinin.

The present study examined the role of intrarenal bradykinin in angiotensin-converting enzyme inhibitor (ACEI)-induced dilation of renal afferent (AFF) and efferent arterioles (EFF) in vivo, and further evaluated whether ACEI-stimulated bradykinin activity differed in superficial (SP) and juxtamedullary nephrons (JM). Arterioles of canine kidneys were visualized with an intravital charge-coupled device camera microscope. E4177 (an angiotensin receptor antagonist, 30 microg/kg) dilated AFF and EFF in SP (15 +/- 3% and 19 +/- 5%) and JM (15 +/- 3% and 18 +/- 4%). Subsequently, cilazaprilat (30 microg/kg) caused further dilation of both AFF (29 +/- 4%) and EFF (36 +/- 4%) in JM, whereas in SP it dilated only EFF (29 +/-3%). Similarly, in the presence of E4177, cilazaprilat caused further increases in sodium excretion. This cilazaprilat-induced vasodilation and natriuresis was abolished by a bradykinin antagonist (N(alpha)-adamantaneacetyl-D-Arg-[Hyp3,Thi5,8,D-Phe7]b radykinin). In parallel with these results, cilazaprilat increased renal bradykinin content, more greatly in the medulla than in the cortex (5.7 +/- 0.4 versus 4.6 +/- 0.1 ng/g). Similarly, cilazaprilat elicited greater bradykinin-dependent increases of nitrite/nitrate in the medulla. In conclusion, zonal heterogeneity in renal bradykinin/nitric oxide levels and segmental differences in reactivity to bradykinin contribute to the diverse responsiveness of renal AFF and EFF to ACEI. ACEI-enhanced kinin action would participate in the amelioration of glomerular hemodynamics and renal sodium excretion by ACEI.

Angiotensin-Converting Enzyme Inhibitors↗

Integrative physiology of coronary microcirculation.

Coronary microvessels play a crucial role for mechanoenergetic interaction between blood flow and myocardial function, which is not uniform transmurally. Thus, highly organized vascular regulations are required for matching local blood flow with myocardial energy requirement. Recently, new technologies to investigate in vivo coronary microcirculation with new knowledge of the signaling molecules for vascular regulation have revolutionized our abilities to understand the integrative regulation of coronary microcirculation. In this review, the mechanical aspects of the interaction between coronary blood flow and myocardium, coronary arte-rial tree and its roles in myocardial blood flow regulation, hierarchical and dynamic control of coronary flow, capillary network and function, function of venous drainage system, and molecular and cellular aspects of integrative coronary blood flow regulation are discussed, focusing on their integrational roles in maintaining coronary microvascular function and cell signaling.

Animals↗

In vivo observations of the intramural arterioles and venules in beating canine hearts.

1. To evaluate the effects of cardiac contraction on intramyocardial (midwall) microvessels, we measured the phasic diameter change of left ventricular intramural arterioles and venules using a novel needle-probe videomicroscope with a CCD camera and compared it with the diameter change in subepicardial and subendocardial vessels. 2. The phasic diameter of the intramural arterioles decreased from 130 +/- 79 ìm in end-diastole to 118 +/- 72 micron (mean +/- S.D.) in end-systole by cardiac contraction (10 +/- 6 %, P < 0.001, n = 21). 3. The phasic diameter in the intramural venules was almost unchanged from end-diastole to end-systole (85 +/- 44 vs. 86 +/- 42 micron, respectively, 2 +/- 6 %, n. s., n = 14). 4. Compared with intramural vessels, the diameters of subendocardial arterioles and venules decreased by a similar extent (arterioles: 10 +/- 8 %, P < 0. 001; venules: 12 +/- 10 %, P < 0.001) from end-diastole to end-systole, respectively, whereas the diameter of the subepicardial arterioles changed little during the cardiac cycle, and subepicardial venule diameter increased by 9 +/- 8 % (P < 0.01) from end-diastole to end-systole. These findings are consistent with our previous report. 5. We suggest that the almost uniform distribution of the cardiac contractility effect and arteriolar transmural pressure between the subendocardium and the midmyocardium, which together constitute the systolic vascular compressive force, accounts for the similarity in the arteriolar diameter changes in both myocardial layers. The smaller intravascular pressure drop from deep to superficial myocardium relative to the larger intramyocardial pressure drop explains the difference in the phasic venular diameter changes across the myocardium.

Animals↗

Decrease in the amount of focal adhesion kinase (p125(FAK)) in interleukin-1beta-stimulated human umbilical vein endothelial cells by binding of human monocytic cell lines.

Monocytes in the blood circulation migrate across endothelial cell monolayers lining the blood vessels and infiltrate into the underlying tissues in inflammation. However, little is known about the mechanisms by which leukocytes migrate across the endothelial barrier after binding and what molecules participate in the process. Addition of the human monocytic cell line THP-1 to interleukin-1beta (IL-1beta)-stimulated human umbilical vein endothelial cells (HUVEC) induced a decrease in the amount of focal adhesion kinase (p125(FAK)) protein, a tyrosine kinase localized at focal contacts and essential for cell attachment to the extracellular matrix, whereas little change was observed in the amount of other molecules associated with cell adhesion such as vascular cell adhesion molecule-1, alpha-catenin, and talin. A maximum decrease in the amount of p125(FAK) was observed 15-30 min after addition of THP-1 cells to HUVEC, after which the level of p125(FAK) gradually recovered. A reduction in the density of actin stress fibers in IL-1beta-activated HUVEC was observed in parallel with the decrease in p125(FAK). The p125(FAK) decrease was partially inhibited by preventing THP-1 binding to HUVEC using a mixture of antibodies to adhesion molecules. We suggest that the decrease in p125(FAK) triggered by binding of monocytes in inflammation facilitates the transendothelial migration of the monocytes by altering the adhesiveness of endothelial cells to the extracellular matrix.

Antibodies, Monoclonal↗

In-vivo measurements of blood flow velocity profiles in canine ilio-femoral anastomotic bypass grafts.

In-vivo velocity profiles were recorded with a 20 MHz 80-channel pulsed Doppler ultrasound velocimeter in canine end-to-side ilio-femoral anastomotic grafts. The geometries were obtained from casts of the anastomotic region, and flow rates were measured with electromagnetic flow probes. Three cases reported here include a "standard" geometry, which was similar to previously studied in vitro models, a stenosed geometry, and a case with below average flow rate. Observed flow features include separation at the hood and toe, movement of the floor stagnation point, and skewed profiles in the proximal outflow segment. Out-of-plane curvature and lateral displacement of the anastomosis inlet appear to have a strong effect on the flow fields. In addition, compliance affects the instantaneous flow rates within the proximal and distal branches.

Anastomosis, Surgical↗

Alpha-adrenergic vasoconstriction reduces systolic retrograde coronary blood flow.

There is a paradoxical alpha-adrenoceptor-mediated coronary vasoconstriction whenever there is adrenergic activation of the heart, as during cardiovascular reflexes or exercise. A previous study demonstrated that this paradoxical vasoconstriction helps maintain blood flow to the vulnerable inner layer of the left ventricular wall during exercise, but the mechanism for this effect was not elucidated. The purpose of the present investigation was to test the hypothesis that alpha-adrenoceptor-mediated vasoconstriction lessens the to-and-fro oscillation of blood flow that occurs in the coronary arterial tree during systole and diastole. Septal coronary artery blood velocity was measured in anesthetized open-chest dogs with a 20-MHz pulsed Doppler velocimeter. Systolic retrograde velocity and diastolic forward velocity were compared during norepinephrine infusion before and after alpha-adrenoceptor blockade with phenoxybenzamine. Systolic aortic pressure was held constant by aortic banding; heart rate was controlled by pacing at 80, 140, and 200 beats/min; and maximum left ventricular dP/dt was unchanged by alpha-blockade. At each pacing rate, systolic retrograde velocity was significantly greater after alpha-blockade, indicating that alpha-vasoconstriction reduced systolic retrograde flow by changing coronary vascular impedance. Transmural blood flow was measured with microspheres in a second group of dogs during the same experimental conditions, and flow to the inner layer of the left ventricle was diminished by alpha-adrenoceptor blockade at a heart rate of 250 beats/min, demonstrating a beneficial effect of alpha-vasoconstriction. In conclusion, adrenergic alpha-adrenoceptor-mediated coronary vasoconstriction reduces systolic retrograde coronary flow during norepinephrine infusion. This lessens to-and-fro flow oscillation in the coronary circulation and probably is the mechanism whereby alpha-vasoconstriction helps maintain blood flow to the inner layer of the left ventricle during exercise.

Adipose Tissue↗

Spatial fluctuation of regional myocardial blood flows.

Digital radiography (100 pixels/mm2) combined with the technique of 3H-labeled desmethylimipramine deposition was employed to visualize regional blood flow distributions in rabbit left ventricular myocardium. A fluctuated pattern of myocardial flow and its dependence on arterial oxygen tension (PaO2) was evaluated with the coefficient of variation (CV) computed at each step of coarse-graining; flow images were revisualized by increasing pixel area (PA) step by step from 0.01 to 1 mm2. The CV values decreased with hypoxia at all resolution levels, suggesting that there is a vascular regulatory mechanism for making myocardial perfusion uniform in response to decreased PaO2. In both perfusion states, CV decreased with increasing PA. The relationship between CV and PA fitted the noninteger power law function, implying an apparent fractality of CV.

Animals↗

Temporal and spatial heterogeneity of blood supply to the heart: visualization and interpretation.

Blood flow of the heart muscle (the coronary circulation) exhibits both temporal and spatial heterogeneity. In this paper, the unique blood velocity waveform during a cardiac cycle, the flow fluctuation of a longer period and the within-layer spatial flow heterogeneity of the coronary circulation are described with a reference to the pathogenesis of angina pectoris and myocardial infarction.

Animals↗

Effects of intraaortic balloon pumping on septal arterial blood flow velocity waveform during severe left main coronary artery stenosis.

OBJECTIVES: We sought to evaluate the effect of intraaortic balloon pumping on the phasic blood velocity waveform into myocardium with severe coronary artery stenosis. BACKGROUND: In the presence of severe coronary artery stenosis, it is not clear whether intraaortic balloon pumping augments intramyocardial inflow during diastole or changes systolic retrograde blood flow from the myocardium to the extramural coronary arteries. METHODS: Using anesthetized open chest dogs (n=7), we introduced severe stenosis in the left main coronary artery to reduce the poststenotic pressure to approximately 60 mm Hg (>90% diameter stenosis). Septal arterial blood flow velocities were measured with a 20-MHz, 80-channel ultrasound pulsed Doppler velocimeter. Left anterior descending arterial flow, aortic pressure and poststenotic distal coronary pressure were measured simultaneously. The diastolic anterograde flow integral and systolic retrograde flow integral were compared in the presence and absence of intraaortic balloon pumping. RESULTS: Although intraaortic balloon pumping augmented diastolic aortic pressure, this pressure increase was not effectively transmitted through stenosis. Septal arterial diastolic flow velocity was not augmented, and left anterior descending arterial flow was unchanged during intraaortic balloon pumping. CONCLUSIONS: In the presence of severe coronary artery stenosis, intraaortic balloon pumping failed to increase diastolic inflow in the myocardium and did not enhance systolic retrograde flow from the myocardium to the extramural coronary artery. Thus, the major effect of intraaortic balloon pumping on the ischemic heart with severe coronary artery stenosis may be achieved by reducing oxygen demand by systolic unloading.

Analysis of Variance↗

Evaluation of intramyocardial coronary blood flow waveform during intraaortic balloon pumping in the absence or presence of coronary stenosis.

Our aim was to evaluate the effects of intraaortic balloon pumping (IABP) on the blood velocity waveform in the absence or presence of coronary artery stenosis. Using anesthetized open-chest dogs, the septal arterial blood flow velocities were measured with a 20 MHz 80-channel ultrasound pulsed Doppler velocimeter in the absence (n = 5) or presence (n = 3) of left main coronary artery stenosis. The blood velocity waveform was analyzed by calculating the systolic retrograde velocity integral (SR) and the diastolic antegrade velocity integral (DA). A slosh ratio was defined as SR/DA. The left anterior descending arterial flow (CBF), aortic pressure (AoP), and poststenotic distal coronary pressure (DiP) were also measured simultaneously. We compared the effect of IABP on the velocity waveforms in the absence and in the presence of coronary artery stenosis. In the absence of stenosis, IABP increased DiP during diastole and augmented DA while it also increased SR. IABP augmented the net CBF because of the greater increase in DA than SR. In the presence of stenosis, however, IABP did not increase DiP and resulted in no significant effect on the net CBF.

Animals↗

Microheterogeneity of myocardial blood flow in rabbit hearts during normoxic and hypoxic states.

The goal of this study was to evaluate microheterogeneity of myocardial blood flow and its dependence on arterial O2 tension (PaO2). We measured within-layer distribution of regional blood flows in the left ventricles of anesthetized rabbits in both normoxic and hypoxic states with myocardial region sizes in the range of 0.01-1.0 mm2. A novel method of digital radiography combined with the technique of 3H-labeled desmethylimipramine deposition enabled us to visualize and accurately quantitate regional blood flow at such high levels of resolution. To analyze myocardial blood flow patterns, we computed the coefficient of variation (CV) and the correlation between adjacent regional flows (CA). The CA values were larger in the hypoxic state (PaO2 = 26 +/- 5 mmHg) than in the normoxic state (PaO2 = 97 +/- 20 mmHg) at all levels of resolution (P < 0.001). In the normoxic state, there was a transmural difference in CA (P < 0.001); CA increased with depth of the left ventricle (from subepicardium to subendocardium). However, the relation between CA and the depth of the left ventricle was not statistically significant in the hypoxic state. The CV values were smaller in the hypoxic state than in the normoxic state at all levels of resolution (P < 0.001). When the degree of resolution was reduced from 0.01 to 1.0 mm2, CV decreased by 75% in the normoxic and by 69% in the hypoxic state. Thus we conclude that 1) the decrease in PaO2 increases similarity of blood flows in nearby regions and decreases myocardial blood flow heterogeneity, and 2) similarity of regional blood flows increases with depth of the left ventricle in the normoxic state, but this transmural difference disappears in the hypoxic state.

Animals↗

Blood velocity profiles in the human renal artery by Doppler ultrasound and their relationship to atherosclerosis.

Blood velocity profiles were measured in the renal branch (diameter 5.9 +/- 1.3 mm) of the aortorenal bifurcation using a 20-MHz 80-channel pulsed Doppler velocimeter during retroperitoneal surgery in 10 patients. The peak Reynolds number was 1145 +/- 140 and the frequency parameter (Wormersley parameter) was 3.0 +/- 0.8. Immediately distal to the ostium of the renal artery, reverse flow, indicating flow separation, was observed near the cranial wall mainly during the first part of the cardiac cycle. There were flows from the cranial to the caudal side of the artery at this location, indicating the presence of strong secondary flows. Two diameters downstream of the ostium, the velocity profiles were skewed to the caudal side in all patients. Four diameters downstream, the flow profile was symmetrical (3 patients) or only slightly skewed (7 patients) and virtually parabolic throughout the cardiac cycle. These observations mean that the flow on the cranial side of the renal branch of the human aortorenal bifurcation is characterized by (1) a bidirectional oscillation of the flow, (2) separation of the flow during systole, and (3) low time-averaged shear rate. These blood velocity patterns may be related to the localization and development of atheromatous plaque that occurs preferentially in this region of the renal artery. Conversely, the unidirectional, axisymmetrical flow found in more distal parts of the renal artery are associated with a very low incidence of lesions.

Adult↗

Direct in vivo observation of subendocardial arteriolar response during reactive hyperemia.

To study the vasodilatory capacity of subendocardial (ENDO) arterioles, we evaluated the reactive hyperemic responses of ENDO as well as subepicardial (EPI) arterioles in 40 dogs by our needle-probe intravital microscope. We also examined the individual and combined effects of an ATP-sensitive K+ channel blocker (glibenclamide, 200 micrograms/kg), an inhibitor of nitric oxide synthase (NG-monomethyl-L-arginine [L-NMMA], 2 mumol/min, 20 minutes), and an adenosine-receptor antagonist (8-phenyltheophylline [8PT], 0.75 mumol/min, 15 minutes). The percent increase in end-diastolic diameter of ENDO arterioles was larger (P < .01) than that of EPI arterioles during reactive hyperemia, especially for the arterioles larger than 120 microns (P < .01). The diastolic-to-systolic vascular pulsation amplitude at the peak flow was greater in ENDO than EPI arterioles (25% versus 6%, P < .05). Compared with control conditions, the presence of both glibenclamide and L-NMMA suppressed the vasodilation responses of ENDO arterioles (P < .01 for both) and EPI arterioles (P < .05 for both). The effect of L-NMMA was greater in ENDO arterioles (P < .01), but that of glibenclamide was not different between ENDO and EPI arterioles. 8PT influenced the hyperemic response, although statistical significance was found only in the flow response. The effect of combined infusion of L-NMMA and glibenclamide with or without 8PT was greater than that of individual infusions in both ENDO and EPI arterioles. Conclusions are as follows: (1) The vasodilatory response of ENDO arterioles was even larger than that of EPI arterioles. Thus, the smaller flow reserve of ENDO arterioles may be caused by other factors, including the greater effects of myocardial compression and nitric oxide on the ENDO arterioles. (2) The vascular responses of ENDO and EPI arterioles were modulated by both endothelium-independent and -dependent vasodilative factors, and the effect of each factor including adenosine was associated with the effects of others.

Adenosine↗

Influence of heart rate and vasoactive drugs on blood flow patterns at the canine ilio-femoral bifurcation.

OBJECTIVE: The aim was to study the effects of altered heart rate and vasoactive drugs on the blood velocity patterns in the region of an arterial bifurcation. METHODS: Blood velocity profiles were measured in an exposed iliofemoral bifurcation of paced dogs using a pulsed Doppler ultrasound velocimeter with high temporal and spatial resolution. RESULTS: Decrease of the heart rate from 120 beats.min-1 (2 Hz) to 60 beats.min-1 (1 Hz) increased the peak forward velocity (30%), the peak reverse velocity (20%), and the duration of reverse flow (25%). Each drug caused qualitatively similar changes in velocity patterns at both heart rates. The systemic administration of angiotensin II reduced peak forward velocity (-26% at 2 Hz and -33% at 1 Hz) and forward flow duration (-15% at 1 Hz), the peak reverse velocity (-30% at 1 Hz), and reverse flow duration (-20% at 2 Hz and -28% at 1 Hz). Glyceryl trinitrate also reduced the peak forward velocity (-19% at both 2 and 1 Hz) but prolonged forward flow duration (28% at 2 Hz and 17% at 1 Hz) and that of reverse flow (45% at 2 Hz and 24% at 1 Hz), and also decreased the degree of oscillation (-16% at 2 Hz). Barnidipine hydrochloride (a calcium channel antagonist) also increased the duration of forward flow (48% at 1 Hz) and of reverse flow (31% at 2 Hz) but reduced the peak reverse velocity (-29% at 1 Hz) and flow oscillation (-22% at 2 Hz and 20% at 1 Hz). CONCLUSIONS: These dramatic changes in the pattern of blood flow, including alterations in the amplitudes and durations of the different phases of the flow cycle, are expected to have important consequences on the shear dependent responses of endothelial cells in the region of the bifurcation.

Angiotensin II↗