Mid-infrared difference-frequency generation source pumped by 1.1-1.5 micrometer dual-wavelength fiber amplifier for trace-gas detection.

Continuous-wave mid-infrared radiation near 3.5 micrometers is generated by difference-frequency mixing of the output of a compact 1.1-1.5 micrometer dual-wavelength fiber amplifier in periodically poled LiNbO3. The diode side-pumped amplifier is constructed with double-cladding Yb-doped fiber followed by single-mode Er/Yb codoped fiber. Output powers of as much as 11 microW at 3.4 micrometers are obtained, and spectroscopic detection of CH4 and H2CO is demonstrated.

Environmental Monitoring↗

Pulsed laser ablation of soft tissues, gels, and aqueous solutions at temperatures below 100 degrees C.

BACKGROUND AND OBJECTIVE: It is desirable for laser microsurgical procedures to remove tissue accurately and with minimal thermal and mechanical damage to adjacent non-irradiated tissues. Pulsed laser ablation can potentially remove biological tissue with microprecision if appropriate irradiation conditions are applied. The major goal of this study was to determine whether laser ablation is possible at temperatures below 100 degrees C. Another aim was to test thermoelastic and recoil stress magnitudes and to estimate their effects on phantom and biological tissue. STUDY DESIGN/MATERIALS AND METHODS: Pulsed laser ablation of water (aqueous solution of potassium chromate) and water containing soft tissues (collagen gel and pig liver) irradiated under confined stress conditions was studied. The ablation mechanism and stages of the ablation process were determined based on time-resolved measurements of laser-induced acoustic waves with simultaneous imaging of the ablation process by laser-flash photography. RESULTS: This study reveals the important role of tensile thermoelastic stress, which produces efficient cavitation that drives material ejection at temperatures substantially below 100 degrees C. Ablation thresholds for the aqueous solution, collagen gel, and liver were 20, 38, and 55 J/cm3, respectively, which correspond to temperature jumps of 5, 10, and 15 degrees C. Two distinct stages of material ejection were observed: (1) initial removal of small volumes of material due to the rupture of single subsurface bubbles, (2) bulk material ablation in the form of jets produced by intense hydrodynamic motions formed upon collapse of large bubbles after coalescence of smaller bubbles. The duration of material ejection upon short-pulse ablation may vary from microseconds to submilliseconds, and depended on the mechanical properties of materials and the incident laser fluence. CONCLUSION: Nanosecond laser ablation of water, gels, and soft tissue under confined-stress conditions of irradiation may occur at temperatures below 100 degrees C. This ablation regime minimizes thermal injury to adjacent tissues and involves thermoelastic stress and recoil pressure magnitudes, which may be tolerated by tissues adjacent to an ablated crater.

Animals↗

The influence of boundary conditions on the accuracy of diffusion theory in time-resolved reflectance spectroscopy of biological tissues.

The applicability of diffusion theory for the determination of tissue optical properties from time-resolved reflectance spectroscopy is investigated. Analytical expressions from diffusion theory using the three most commonly assumed boundary conditions at the air-tissue interface are compared with time-resolved Monte Carlo simulations and measurements on tissue phantoms. The effects of the choice of the boundary conditions on the accuracy of the findings for the optical parameters are quantified, and criteria for accurate curve-fitting algorithms are developed.

Algorithms↗

Influence of blood vessels on the measurement of hemoglobin oxygenation as determined by time-resolved reflectance spectroscopy.

We report the development of a heterogeneous resin-tube model to study the influence of blood vessels on the apparent absorption of the system, mu a(sys), using a time-resolved technique. The experimental results show that mu a(sys) depends on the absorption inside the tubes, mu a(tube), tube diameters, and tube-to-sample volume ratios. A mathematical expression relating mu a(sys) and mu a(tube) is derived based on the experimental results and is verified by time-resolved Monte Carlo simulations for heterogeneous models. This analytical formula predicts that the apparent absorption coefficient measured on a biological organ is a volume-weighted sum of the absorption coefficients of different absorbing components. We present some apparent absorption coefficients measured in vivo in animals and humans and discuss improved algorithms that calculate the hemoglobin saturation by including background-tissue absorption and blood vessel distribution.

Blood Vessels↗

XeCl laser ablation of atherosclerotic aorta: luminescence spectroscopy of ablation products.

XeCl laser ablation of atherosclerotic aorta tissue was investigated. Luminescence spectra of ablation products were measured for soft and hard arterial tissues. A pronounced difference observed between plume luminescence for various plaques and normal vessel wall correlates with the chemical composition of the tissue. The mechanism of plume luminescence appeared to be thermochemical excitation ablation products (particles, atoms, molecules, etc.) in the air. The process of soft tissue ablation was delayed with respect to the exciting laser pulse at relatively low laser fluences close to the ablation threshold. The kinetics of the ablation process as a function of laser-pulse energy fluence is reported. The data indicate that tissue ejection mechanism, which involves vapor bubbles formation, expansion and explosion, is suitable for the description of the XeCl excimer laser ablation of soft tissues.

Angioplasty, Laser↗

Atherosclerotic tissue analysis by time-resolved XeCl excimer laser reflectometry.

The temporal modification of XeCl laser pulses reflected from human aorta tissue immersed in saline has been studied. Dynamic tissue reflectivity of both normal and atherosclerotic tissues has been examined for various incident pulse fluences between 0.7 and 6.5 J/cm2. Changes in reflected pulse duration are observed for fluences at or above 2.6 J/cm2 with normal tissue targets and 3.0 J/cm2 with calcified plaque. Such reflected pulse analysis may prove useful in identifying tissue targets for ablation during laser angioplasty.

Adult↗

XeCl laser-induced fluorescence of atherosclerotic arteries. Spectral similarities between lipid-rich lesions and peroxidized lipoproteins.

Autofluorescence spectroscopy of arterial surfaces provides information about the distribution and composition of atherosclerotic plaques. The aim of the study was to determine whether accumulation of peroxidized lipoproteins in arterial walls, a process postulated to play a role in initiating atherosclerotic changes, can be demonstrated by fluorescence spectroscopy. XeCl excimer laser (308 nm)-induced fluorescence of human aortas containing early lipid-rich noncollagenous lesions exhibited marked red shifts and broadening of the fluorescence spectra compared with spectra from nonatherosclerotic aortas. Similar profiles were observed in spectra obtained from oxidatively modified low density lipoprotein but not native low density lipoprotein. In hypercholesterolemic rabbits with early foam cell lesions, spectral shifts resembled those of oxidized beta-very low density lipoprotein, the major lipoprotein accumulating in arteries of rabbits fed cholesterol. XeCl laser-fluorescence spectroscopy of arterial surfaces may be useful for the identification of arteries accumulating modified lipoproteins (oxidized low density lipoprotein), a chemical change indicative of atherosclerosis in its early and probably reversible stages.

Angioscopes↗

XeCl laser ablation of atherosclerotic aorta: optical properties and energy pathways.

The energetics of 308-nm excimer laser irradiation of human aorta were studied. The heat generation that occurred during laser irradiation of atherosclerotic aorta equaled the absorbed laser energy minus the fraction of energy for escaping fluorescence (0.8-1.6%) and photochemical decomposition (2%). The absorbed laser energy is equal to the total delivered light energy minus the energy lost as specular reflectance (2.4%, air/tissue) and diffuse reflectance (11.5-15.5%). Overall, about 79-83.5% of the delivered light energy was converted to heat. We conclude that the mechanism of XeCl laser ablation of soft tissue involves thermal overheating of the irradiated volume with subsequent explosive vaporization. The optical properties of normal wall of human aorta and fibrous plaque, both native and denatured were determined. The light scattering was significant and sufficient to cause a subsurface fluence (J/cm2) in native aorta that equaled 1.8 times the broad-beam radiant exposure, phi o (2.7 phi o for denatured aorta). An optical fiber must have a diameter of at least 800 microns to achieve a maximum light penetration (approximately 200 microns for phi o/e) in the aorta along the central axis of the beam.

Aorta↗

Laser-induced autofluorescence of human arteries.

A new technique for imaging the intimal surface of arteries through optic fibers has been devised. With the aid of an optical multichannel analyzer, we recorded in real time fluorescence spectra during excitation of the arterial surface with an argon ion laser. Spectral parameters were used to detect atherosclerotic plaques and to discriminate normal tissue from lipid rich and calcified atheromas. By digitizing relative intensity values and the ratios of the peak at 550 nm to that at 520 nm into a gray scale, we generated pseudocolor maps of the arterial wall of 10 human aortas. Specific color distributions were congruent with the distribution of calcified tissue visualized by soft x-ray radiography and the distribution of lipid delineated by staining with Sudan IV. Thus, bidimensional maps obtained by laser spectroscopy can be used to identify the presence and composition of atherosclerotic lesions. Fluorescence imaging may prove to be an important application of laser techniques for the diagnosis and treatment of atherosclerosis.

Adolescent↗

Tissue interactions and measurement of ablation rates with ultraviolet and visible lasers in canine and human arteries.

Ablation rates measured as the depth of tissue excavation per unit time were determined in human and canine aortas subjected to radiation with ultraviolet (UV) excimer (ArF 193 nm, KrF 248 nm, XeF 351 nm) and visible lasers [continuous wave (cw) and 50-ms chopped argon ion, 478 nm-514 nm; pulsed double-frequency Nd:YAG, 532 nm]. For UV and pulsed double-frequency Nd:YAG lasers ablation rates were constant in time and depended linearly on average laser power, but for cw and chopped argon lasers ablation rates varied with irradiation time and were nonlinearly dependent on laser power. In human aortas, atherosclerosis without gross calcification had no influence on ablation rates. Charring and tissue disruption were observed with cw and chopped argon ion, whereas excimer and pulsed Nd:YAG lasers produced only minimal injury to surrounding tissue. We conclude that the determination of ablation rates is useful for the selection of laser wavelengths and power densities applicable to angioplasty and that UV and pulsed visible laser permit a better control of ablation compared to continuous wave lasers.

Animals↗

Portable fiber-coupled diode-laser-based sensor for multiple trace gas detection.

Tunable narrowband mid-infrared radiation from 3.25 to 4.4 micrometers is generated by a compact fiber-coupled, difference-frequency-based spectroscopic source. A 20-mW external cavity diode laser (with a tuning range from 814 to 870 nm) and a 50-mW distributed-Bragg-reflector diode-laser-seeded ytterbium-doped fiber amplifier operating at 1083 nm are difference-frequency mixed in a multi-grating, temperature-controlled periodically poled LiNbO3 crystal. A conversion efficiency of 0.44 mW/(W2cm) (corresponding to a power of approximately equal to 3 microW at 3.3 micrometers) represents the highest conversion efficiency reported for a portable device. Performance characteristics of such a sensor and its application to spectroscopic detection of CO2, N2O, H2CO, HCl, NO2, and CH4 will be reported in this work.

Carbon Dioxide↗

Novel diode laser-based sensors for gas sensing applications.

The development of compact spectroscopic gas sensors and their applications to environmental sensing will be described. These sensors employ mid-infrared difference-frequency generation (DFG) in periodically poled lithium niobate (PPLN) crystals pumped by two single-frequency solid state lasers such as diode lasers, diode-pumped solid state, and fiber lasers. Ultrasensitive, highly selective, and real-time measurements of several important atmospheric trace gases, including carbon monoxide, nitrous oxide, carbon dioxide, formaldehyde [correction of formaldehye], and methane, have been demonstrated.

Carbon Dioxide↗