The effects of fluid penetration and interfacial porosity on the fixation of cemented femoral components.

We have investigated the role of the penetration of saline on the shear strength of the cement-stem interface for stems inserted at room temperature and those preheated to 37 degrees C using a variety of commercial bone cements. Immersion in saline for two weeks at 37 degrees C reduced interfacial strength by 56% to 88% after insertion at room temperature and by 28% to 49% after preheating of the stem. The reduction in porosity as a result of preheating ranged from 71% to 100%. Increased porosity correlated with a reduction in shear strength after immersion in saline (r = 0.839, p < 0.01) indicating that interfacial porosity may act as a fluid conduit.

Arthroplasty, Replacement, Hip↗

Effects of the initial temperature of acrylic bone cement liquid monomer on the properties of the stem-cement interface and cement polymerization.

It has been shown that preheating the femoral stem prior to insertion minimizes interfacial porosity at the stem-cement interface. In this study, the effects of methylmethacrylate monomer temperature prior to mixing on the properties of stem-cement interface and cement polymerization were evaluated for 4 degrees C, room temperature, and 37 degrees C using a test model and cementing techniques that simulated a clinical situation. The nature and extent of interfacial porosity of stem-cement interface was quantified, the static shear strength of the stem-cement interface determined, and the time and temperature of polymerization at the cement-bone interface were measured. Compared to RT monomer, preheating monomer to 37 degrees C produced higher polymerization temperatures and greater initial interfacial shear strength with an unchanged amount of interfacial porosity. Precooling monomer to 4 degrees C produced lower polymerization temperatures and decreased initial interfacial shear strength, with the amount of interfacial porosity unchanged compared to the RT group. Although clinical techniques of preheating or precooling bone cement have some effects on the properties of the stem-cement interface and cement polymerization, they do not appear to enhance implant fixation.

Chromium↗

Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute.

STUDY DESIGN: A biomechanical study to evaluate the effects of a biodegradable calcium phosphate (Ca-P) bone substitute on the fixation strength and bending rigidity of vertebral body screws. OBJECTIVES: To determine if an injectable, biodegradable Ca-P bone substitute provides significant augmentation of anterior vertebral screw fixation in the osteoporotic spine. SUMMARY OF BACKGROUND DATA: Polymethylmethacrylate (PMMA) augmented screws have been used clinically; however, there is concern about thermal damage to the neural elements during polymerization of the PMMA as well as its negative effects on bone remodeling. Injectable, biodegradable Ca-P bone substitutes have shown enhanced fixation of pedicle screws. METHODS: Sixteen fresh cadaveric thoracolumbar vertebrae were randomly divided into two groups: control (no augmentation) (n = 8) and Ca-P bone substitute augmentation (n = 8) groups. Bone-screw fixation rigidity in bending was determined initially and after 10(5) cycles, followed by pullout testing of the screw to failure to determine pullout strength and stiffness. RESULTS: The bone-screw bending rigidity for the Ca-P bone substitute group was significantly greater than the control group, initially (58%) and after cyclic loading (125%). The pullout strength for Ca-P bone substitute group (1848 +/- 166 N) was significantly greater than the control group (665 +/- 92 N) (P < 0.01). Stiffness in pullout for the Ca-P bone substitute groups (399 +/- 69 N/mm) was significantly higher than the control group (210 +/- 51 N/mm) (P < 0.01). CONCLUSION: This study demonstrated that augmentation of anterior vertebral body screw fixation with a biodegradable Ca-P bone substitute is a potential alternative to the use of PMMA cement.

Absorbable Implants↗

The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty.

The effect of stem length, diameter, and mode of fixation on the motion and stress transfer of a cemented tibial tray were evaluated for in 12 cadaver knees. There was a significant decrease in motion of the tibial tray with increasing press-fit stem length (75-150 mm) and increasing stem diameter (10-14 mm). Cemented tibial stems showed significantly less tray motion than uncemented stems. The short cemented stems produced tray stability equivalent to long press-fit stems. Although there was a trend for increased proximal tibial stress shielding with the use of cement and longer, wider stems, the trend was not statistically significant. Modular, press-fit stems can achieve tray stability similar to a smaller cemented stem and can avoid the potential problems with cement.

Adult↗

Effect of articular step-off and meniscectomy on joint alignment and contact pressures for fractures of the lateral tibial plateau.

OBJECTIVES: To determine the effects of intraarticular step-off and lateral meniscectomy on the alignment of the articular axis, contact area, and pressures for lateral tibial plateau fractures. DESIGN: Biomechanical cadaver study. INTERVENTION: Six fresh cadaveric knees were used. A simulated split fracture of the lateral tibial plateau was reproducibly created by osteotomies, and articular step-offs of zero, one, two, four, and six millimeters were achieved by using support shims. The knee was loaded with 500 newtons in 0 degrees and 350 newtons in 30 degrees of flexion. A digital camera determined changes in the alignment of the articular axis, and F-Scan sensors were inserted into the medial and lateral joint compartments to determine the pressures and pressure distributions. MAIN OUTCOME MEASUREMENT: Each specimen was tested at step-offs of zero, one, two, four, and six millimeters, with the presence or absence of the lateral meniscus. The changes in alignment of the articular axis, the contact area, and the average and maximum contact pressures for each condyle were obtained. RESULTS: Increased articular step-off heights progressively increased valgus angulation and average and maximum contact pressures and progressively decreased contact areas in lateral compartment. At a six-millimeter step-off with 0 degrees of flexion, the valgus angle increased an average of 7.6 degrees, and average contact pressures and maximum contact pressures increased an average of 208 percent and 97 percent, respectively, and contact area decreased an average of 33 percent (p < 0.05). Meniscectomy increased valgus angles by an average of 38 percent and contact pressures by an average of 45 percent and decreased contact areas by 26 percent in the lateral compartment at the same articular step-off heights (p < 0.05). CONCLUSION: The results of this study show the importance of decreasing articular step-off heights in treating lateral tibial plateau split fractures, particularly if a meniscectomy is performed.

Adult↗

Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques.

This study evaluated 5 currently used periprosthetic femoral shaft fracture fixation techniques to determine which technique provided the greatest fixation stability. Periprosthetic fractures in 30 synthetic femurs were fixed with a plate with cables, plate with proximal cables and distal bicortical screws (Ogden concept), plate with proximal unicortical screws and distal bicortical screws, plate with proximal unicortical screws and cables and distal bicortical screws, or 2 allograft cortical strut grafts with cables. These specimens were then tested in 3 physiologic loading modes. The plate constructs with proximal unicortical screws and distal bicortical screws or with proximal unicortical screws, proximal cables, and distal bicortical screws were significantly more stable in axial compression, lateral bending, and torsional loading than the other fixation constructs studied.

Biomechanical Phenomena↗

The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation.

Patellofemoral complications, instability, and tibial polyethylene wear after total knee arthroplasty (TKA) resulting from malrotation of the tibial or femoral components (or both) may be difficult to diagnose based on physical examination and standard knee radiographs. The preoperative assessment of implant rotational alignment is critical in planning treatment because the femoral or tibial component (or both) may need to be revised if malpositioned. The purpose of this study was to ascertain the accuracy of computed tomography (CT) scan for determining rotational alignment of femoral and tibial components in TKA. TKA components were inserted in human cadaver specimens at neutral and 5 degrees of external or internal rotation. For each position, the amount of rotation, determined from digital photographs, was compared with CT scan. The correlation coefficient between these two values averaged 0.87, which was significant at P < .05. The CT scan protocol described in this study can be applied clinically to patients with patellofemoral complaints to confirm or rule out the presence of component malrotation.

Arthroplasty, Replacement, Knee↗

Effect of posterior cut angle on tibial component loading.

Although clinical studies have shown that posterior cut angle affects tibial component stability, biomechanical studies are lacking. Fifteen Sawbones tibiae were divided into 5 groups and prepared with 0 degrees , 3 degrees, 6 degrees, 9 degrees, and -5 degrees tibial surface cuts, and a tibial component was implanted with cement. Using a standard and then a highly congruent polyethylene insert, the knee was loaded at 0 degrees and 30 degrees of flexion. There were statistically significant increases in anterior micromotion of the standard polyethylene component for each increase in posterior slope cut angle, which increased for the highly congruent polyethylene component. The anterior slope cut (-5 degrees) led to significant posterior micromotion of the tibial polyethylene component. Increased posterior slope cut angle significantly decreased tibial anterior compressive strains and significantly increased tibial posterior compressive strains. The highly congruent insert significantly increased this posterior strain. The results indicate that cutting the articular surface of the tibia at a 0 degrees or 3 degrees posterior slope provides the greatest tibial component stability.

Arthroplasty, Replacement, Knee↗

A biomechanical comparison of Schuhli nuts or cement augmented screws for plating of humeral fractures.

Schuhli locking nuts can be used in poor quality cortical bone to enhance fixation stability as an alternative to cement augmented screws. This study compared the fixation strength and stability of plate constructs using Schuhli locking nuts with standard screws and cement augmented screws for fixation of simulated humeral shaft fractures in a test model with osteoporosis. The constructs were tested in axial compression, 4-point bending, and torsion to determine fixation stability. The humeri were cycled in torsion (4.5 Nm) for 1000 cycles to simulate upper extremity use during the early postoperative period and retested for stability. The Schuhli locking nuts and cement augmented screws had significantly greater fixation stability than the standard screws before (range, 6-14 times greater) and after cycling in torsional loading (range, 3-3.6 times greater). Although cement augmented screws and Schuhli augmentation showed increased fixation stability compared with the standard screws in axial and 4-point bending before cycling (range, 1.3-1.4 times greater), this was not significant. Compared with Schuhli fixation, cement augmented screws showed no significant difference in fixation stability in all loading modes before and after cycling. Schuhli locking nuts offer the stability of cement augmentation while avoiding its potential adverse effects on fracture healing with extravasation and thermal necrosis.

Biomechanical Phenomena↗

New technique for treatment of unstable distal femur fractures by locked double-plating: case report and biomechanical evaluation.

BACKGROUND: A comminuted, intra-articular distal femur fracture was surgically treated by the authors with a locked, double-plating technique because fixation stability could not be initially achieved by using a standard double-plating technique. The purpose of this study was to determine biomechanically whether a locked double-plate construct would enhance fixation stability compared with a nonlocked double-plate construct. METHODS: Six matched pairs of mildly osteopenic femurs were selected and all had a reproducible intra-articular fracture pattern created. Each pair underwent fixation with either a double-plating construct or a locked, double-plating construct that was randomly assigned. The instrumented femurs were then mechanically tested in several loading modes to determine fixation stability. After initial testing, specimens were cyclically loaded and retested for stability. RESULTS: The locked, double-plating construct provided significantly greater fixation stability than the standard double-plating construct in precycling and postcycling biomechanical testing. CONCLUSION: The technique described is particularly applicable for severely comminuted fractures of the distal femur and fractures in osteopenic bone with poor screw purchase. It offers a simple alternative for enhancing fixation stability, which avoids the potential complications of methylmethacrylate-enhanced screw fixation.

Biomechanical Phenomena↗

Internal fixation of cervical trauma following corpectomy and reconstruction. The effects of posterior element injury.

Although biomechanical data indicates that anterior fixation alone in unstable cervical injuries may not provide adequate stability, reports of clinical series indicate general success with this method of treatment. The specific contribution of posterior column injury to overall stability following reconstruction has not been evaluated. This study examined the biomechanical stability of anterior and/or posterior plate fixation following anterior corpectomy and reconstruction for unstable cervical injuries with varying degrees of posterior element injury. The C4-C6 motion segments of ten fresh frozen bovine cervical spines were used. After mounting, nondestructive mechanical testing in axial compression, torsion, flexion, extension, and lateral bending was done as an intact control. A C5 corpectomy with reconstruction using a synthetic bone graft was performed and the posterior ligaments sectioned at the C5-C6 level. Each specimen was sequentially instrumented with anterior and posterior plating alone and in combination and each construct was mechanically retested. The specimens were then further destabilized by bilateral facetectomies at C5-C6 and again tested with the same instrumentation combinations. In comparison to the controls, the spines with a C5 corpectomy/bone graft and posterior ligament rupture with anterior plating demonstrated significantly increased stiffness in flexion, extension, and lateral bending; posterior plating increased stiffness in only flexion and lateral bending. In axial compression and torsion, anterior or posterior plating demonstrated stiffness similar to the controls. Further destabilization by facetectomy significantly decreased stiffness of the instrumented construct (less than control) in torsion with anterior or posterior plate fixation alone. Combined plating showed increased stability compared to controls in all loading conditions for both patterns of instability. Anterior plating alone was able to restore the stability of the cervical spines with posterior ligamentous injury after corpectomy, but it failed to do so with the addition of bilateral facetectomies. For the unstable cervical spine with significant bilateral loss of posterior bony contact, anterior or posterior plating alone may not provide sufficient stabilization in the absence of any additional external immobilization. Combined plating should be considered, which may obviate the need for external immobilization.

Analysis of Variance↗

Characterization of acromial concavity. An in vitro computer analysis.

Variations in the shape and orientation of the anterior acromion have been implicated as predisposing factors for the development of rotator cuff problems. We determined and analyzed by computer digitization the anterior and posterior acromial slopes for 141 cadaver shoulders (whose rotator cuff status had been previously assessed). No significant differences in either the anterior or posterior angle were found between the intact and rotator cuff tear groups. Frequency histograms of both angles demonstrated continuous, normal distributions. The individual acromions were consistently asymmetric in that the anterior slope was larger than the posterior slope. However, the anterior slope distribution did not reveal groupings indicative of the specific acromial types previously reported. These results suggest that acromial classification into flat, curved, and hooked types does not accurately describe the actual anatomical findings.

Acromion↗

Dislocations of the sternoclavicular joint.

The effects of the anterior and posterior sternoclavicular joint (SCJ) soft tissue structures on joint dislocation strength by sequential sectioning the ligaments and capsule of twenty-eight SCJs were evaluated. The medial clavicle of each specimen was initially loaded in the anterior and posterior directions to provide control values for joint laxity. The anterior or posterior ligaments and capsular structures of the SCJs were then selectively cut and the specimens retested for laxity and then loaded to failure simulating either anterior or posterior dislocation. Testing of intact specimens showed that the posterior ligaments were stiffer than other structures in that it was significantly more difficult to posteriorly displace the SCJ than in any other direction and that the capsule was the important anterior structure affecting joint laxity. Load-to-failure testing showed that it required 50% more force to create a failure by posterior dislocation than by anterior dislocation. The results of this study explain the clinical rarity of posterior sternoclavicular joint dislocations.

Aged↗

The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures.

STUDY DESIGN: A biomechanical study comparing two materials for augmentation of osteoporotic vertebral bodies and vertebral bodies after compression fracture. OBJECTIVES: To compare an injected, biodegradable calcium phosphate bone substitute with injected polymethylmethacrylate bone cement for strengthening osteoporotic vertebral bodies and improving the integrity of vertebral compression fractures. SUMMARY OF BACKGROUND DATA: Injection of polymethylmethacrylate bone cement into fractured vertebral bodies has been used clinically. However, there is concern about thermal damage to the neural elements during polymerization of the polymethylmethacrylate bone cement as well as its negative effects on bone remodeling. Biodegradable calcium phosphate bone substitutes have been studied for enhancement of fixation in fractured vertebrae. METHODS: Forty fresh osteoporotic thoracolumbar vertebrae were used for two separate parts of this study: 1) injection into osteoporotic vertebrae: intact control (n = 8), calcium phosphate (n = 8), and polymethylmethacrylate bone cement (n = 8) groups. Each specimen then was loaded in anterior compression until failure; 2) injection into postfractured vertebrae: calcium phosphate (n = 8) and polymethylmethacrylate bone cement (n = 8) groups. Before and after injection, the specimens were radiographed in the lateral projection to determine changes in vertebral body height and then loaded to failure in anterior bending. RESULTS: For intact osteoporotic vertebrae, the average fracture strength was 527 +/- 43 N (stiffness, 84 +/- 11 N/mm), 1063 +/- 127 N (stiffness, 157 +/- 21 N/mm) for the group injected with calcium phosphate, and 1036 +/- 100 N (stiffness, 156 +/- 8 N/mm) for the group injected with polymethylmethacrylate bone cement. The fracture strength and stiffness in the calcium phosphate bone substitute group and those in the polymethylmethacrylate bone cement group were similar and significantly stronger than those in intact control group (P < 0.05). For the compression fracture study, anterior vertebral height was increased 58.5 +/- 4.6% in the group injected with calcium phosphate and 58.0 +/- 6.5% in the group injected with polymethylmethacrylate bone cement as compared with preinjection fracture heights. No significant difference between the two groups was found in anterior vertebral height, fracture strength, or stiffness. CONCLUSION: This study demonstrated that the injection of a biodegradable calcium phosphate bone substitute to strengthen osteoporotic vertebral bodies or improve vertebral compression fractures might provide an alternative to the use of polymethylmethacrylate bone cement.

Absorbable Implants↗

The effect of locking fixation screws on the stability of anterior cervical plating.

STUDY DESIGN: Current anterior cervical plate systems were tested with locked and unlocked fixation screws and with unicortical and bicortical fixation screws to determine fixation rigidity and pull-off strengths. OBJECTIVES: To evaluate the effects of screw-plate locking and screw length on fixation strength and stability of anterior cervical plates. SUMMARY OF BACKGROUND DATA: New plate systems provide for rigid locking of the screw-plate interface, theoretically increasing construct rigidity, allowing unicortical fixation, and preventing screw back-out. There are few data on the effects of locking screws on the stability of anterior cervical plating. METHODS: Eighty fresh lamb vertebrae (C3-T1) were used. Test systems included: Cervical Spine Locking Plate (CSLP; Synthes, Paoli, PA, Orion plate (Sofamor-Danek, Memphis, TN), and Acroplate (AcroMed, Cleveland, OH). The CSLP and Orion plates were tested with fixation screws, locked and unlocked, and the AcroMed plate with unicortical and bicortical screw purchase. Biomechanical testing of the screw-plate constructs was performed to determine the initial bone-plate rigidity and pull-off strength. A 2.5-Nm cyclic bending moment was then applied to additional constructs for 10(5) cycles, and these constructs retested. RESULTS: Locked CSLP and Orion constructs were more rigid than all unlocked unicortical systems initially and after cyclic loading (P < 0.05). After cycling, the rigidity of all unlocked unicortical constructs decreased significantly (P < 0.05). There was no significant difference in pull-off strengths between the CSLP, the Orion, and the unicortical AcroMed plate. However, all had significantly less pull-off strength than the AcroMed plate with bicortical screws. A negative correlation was observed between initial pull-off strength and sagittal vertebral body diameter. CONCLUSIONS: Locking screws significantly increased the rigidity of the tested screw-plate systems initially and after cyclic loading. Because pull-off strength was affected by the vertebral body diameter, use of longer unicortical screws may be clinically beneficial in the patient with larger cervical vertebrae.

Animals↗

The effect of acetabular cup orientations on limiting hip rotation.

The orientation of the acetabular cup and position of lip augmentation (if present) may improve postoperative total hip replacement stability by decreasing dislocation caused by hip prosthesis impingement during rotation. To determine how these cup parameters affect dislocation, the range and amount of rotation for two standard femoral components was determined in a Sawbones hemipelvis model. The parameters that allowed for maximal range of rotation were a cup angle of inclination between 35 degrees and 45 degrees and cup anteversion between 0 degrees and 10 degrees. Cup anteversion angles greater than 20 degrees and cup angles of inclination greater than 45 degrees significantly limited internal and external rotation, particularly for hip flexion greater than 60 degrees. The position of the cup lip augmentation did not affect the amount of rotation except when the hip was flexed and the lip superiorly oriented. Although there are currently devices to facilitate a particular cup position, hip stem type and orientation are other important factors affecting range of rotation that must be considered.

Acetabulum↗

Analysis of the heel pad fat in rheumatoid arthritis.

The heel fat pad is organized, both in structure and in composition, to bear the stresses and strains of normal activities and to permit pain-free weightbearing. The fatty acid composition of heel pads in 11 patients with rheumatoid arthritis, a disease process frequently associated with heel fat pad atrophy, was analyzed using gas-liquid chromatography and was compared with that of patients without systemic disease. The heels of patients with rheumatoid arthritis demonstrated a significant change in the composition of saturated fatty acids when compared with heels of nonrheumatoid patients. This composition reflects an increased fat viscosity, which decreases the ability of the heel to absorb and dissipate the energy generated during ambulation. This factor could cause degeneration of the heel septal system, with resulting fat pad atrophy.