Ultrasonic diagnostic system for interactive interrogation of adult brain through intact skull.

An integrated ultrasonic system has been developed employing static gray scale imaging, digital image processing, and analyses of quantitative ultrasonic backscatter for interactive interrogation of brain through the adult human skull. Operating at 750 kHz, to avoid severe spatial and temporal pulse distortion which accompany ultrasonic transkull transmission at higher frequencies, storage and image processing of successive images taken at selected gain settings in the same image plane allow the reconstruction of a composite cross-section of the brain and skull and enable visualization of internal brain structure. Analyses of digitized backscatter data obtained with the visualization transducer over selectable interrogation paths referenced to the cross-sectional image permit quantitative classification of tissue type independent of qualitative visual image analysis, such that enhanced diagnostic potential is provided. A previous paper described in detail the modifications of the commercial ultrasound diagnostic unit which serves as the core of this system. The present paper presents the rationale for the integrated system design approach, as well as a description of graphics display and tissue classification features which have been incorporated into the instrumentation configuration and are deemed necessary for successful transkull ultrasonic imaging and diagnosis.

Brain Diseases↗

Comparison of computed sonographic tomography and pulse-echo imaging in the head.

Computed sonographic transmission tomograms of infant and adult human cadaver heads are presented and compared with sonographic pulse-echo and x-ray tomograms of the same horizontal planes. The sonographic attenuation tomograms were reconstructed from broadband transmission data obtained using the rotate/translate axial scan mode in much the same way as x-ray tomography is performed. The formalin-fixed infant cadaver head was scanned through the anterior fontanelle using pulse-echo and in a horizontal plane (3.3 cm superior to the Frankfort plane) using both pulse-echo (3.5 MHz and 5 MHz) and transmission sonography (5 MHz). The computed sonographic transmission tomogram revealed superior anatomic detail as compared with the pulse-echo images obtained in the horizontal plane and compared favorably with x-ray scans. The quantitative, noninvasive nature of sonographic tomography shows promise for clinical applicability in the infant. In the adult human cadaver, sonographic tomograms at 750 kHz are presented in both the transskull and excised brain conditions. These scans also offer promise for the possible clinical exploration of the method.

Adult↗