Search PubMedSearch

Biomedical subjects

F Hillenkamp

Publications and source records attributed to F Hillenkamp.

At least 19 recordsLinked to original sources

Infrared MALDI mass spectrometry of large nucleic acids.

Mass spectrometry has become an increasingly important tool of high accuracy, efficiency, and speed for the routine analysis of nucleic acids. To make it useful for large-scale sequencing of genomic material as required for example in genotyping and clinical diagnosis, it is necessary to find approaches that allow the analysis of sequences much larger than the 100 nucleotides currently possible. Matrix-assisted laser desorption/ionization (MALDI) mass spectra of synthetic DNA, restriction enzyme fragments of plasmid DNA, and RNA transcripts up to a size of 2180 nucleotides are reported. The demonstrated mass accuracy of 1 percent or better and the sample requirement of a few femtomoles or less surpass all currently available techniques for the analysis of large nucleic acids. DNA and RNA can be analyzed with only a limited investment in sample purification.

Calibration

DNA sequence analysis by MALDI mass spectrometry.

Conventional DNA sequencing is based on gel electrophoretic separation of the sequencing products. Gel casting and electrophoresis are the time limiting steps, and the gel separation is occasionally imperfect due to aberrant mobility of certain fragments, leading to erroneous sequence determination. Furthermore, illegitimately terminated products frequently cannot be distinguished from correctly terminated ones, a phenomenon that also obscures data interpretation. In the present work the use of MALDI mass spectrometry for sequencing of DNA amplified from clinical samples is implemented. The unambiguous and fast identification of deletions and substitutions in DNA amplified from heterozygous carriers realistically suggest MALDI mass spectrometry as a future alternative to conventional sequencing procedures for high throughput screening for mutations. Unique features of the method are demonstrated by sequencing a DNA fragment that could not be sequenced conventionally because of gel electrophoretic band compression and the presence of multiple non-specific termination products. Taking advantage of the accurate mass information provided by MALDI mass spectrometry, the sequence was deduced, and the nature of the non-specific termination could be determined. The method described here increases the fidelity in DNA sequencing, is fast, compatible with standard DNA sequencing procedures, and amenable to automation.

Animals

Separation and identification of peptides in single neurons by microcolumn liquid chromatography-matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and postsource decay analysis.

Microcolumn liquid chromatography (LC) was interfaced with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for separation and identification of peptides present in single neurons from the brain of the snail Lymnaea stagnalis. The nanoliter microcolumn LC effluent, mixed off-line with nanoliter matrix solution, was deposited onto the sample target every 60 s, producing fractions of approximately 145 nL in volume, which, upon drying, produced spots of approximately 1 mm in size. At the end of the chromatographic separation, fractions from the sample target were scanned by MALDI-TOF-MS. Identification of peptide peaks was achieved on the basis of LC elution order and mass information. Further identification based on sequence information was carried out for a native peptide fractionated by microcolumn LC from a single neuron with the postsource decay technique.

Animals

Investigations of the metastable decay of DNA under ultraviolet matrix-assisted laser desorption/ionization conditions with post-source-decay analysis and hydrogen/deuterium exchange.

The fragmentation of positive ions of DNA under the conditions of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was investigated by post-source decay (PSD) analysis and hydrogen/deuterium (H/D) exchange. Spectra of five different synthetic 4mer oligonucleotides were recorded. As a main result the hypothesis was confirmed that for these ions all fragment ions result from processes, initiated by protonation/deuteration of a suitable base followed by a loss of this base as a neutral or ion and further backbone cleavages. The three bases adenine, guanine, and cytosine all exhibit comparable lability for fragmentation. The spectra show evidence for an interaction of the adenine base with the phosphate backbone. Signals of fragments containing TT- and CT-cycloadducts were observed in the spectra.

Calibration

Detection of noncovalent tRNA.aminoacyl-tRNA synthetase complexes by matrix-assisted laser desorption/ionization mass spectrometry.

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-MS) was used for the study of complexes formed by yeast seryl-tRNA synthetase (SerRS) and tyrosyl-tRNA synthetase (TyrRS) with tRNASer and tRNATyr. Cognate and noncognate complexes were easily distinguished due to a large mass difference between the two tRNAs. Both homodimeric synthetases gave MS spectra indicating intact desorption of dimers. The spectra of synthetase-cognate tRNA mixtures showed peaks of free components and peaks assigned to complexes. Noncognate complexes were also detected. In competition experiments, where both tRNA species were mixed with each enzyme only cognate alpha2.tRNA complexes were observed. Only cognate alpha2.tRNA2 complexes were detected with each enzyme. These results demonstrate that MALDI-MS can be used successfully for accurate mass and, thus, stoichiometry determination of specific high molecular weight noncovalent protein-nucleic acid complexes.

Binding, Competitive

Pattern changes of pituitary peptides in rat after salt-loading as detected by means of direct, semiquantitative mass spectrometric profiling.

We have established a differential peptide display method, based on a mass spectrometric technique, to detect peptides that show semiquantitative changes in the neurointermediate lobe (NIL) of individual rats subjected to salt-loading. We employed matrix-assisted laser desorption/ionization mass spectrometry, using a single-reference peptide in combination with careful scanning of the whole crystal rim of the matrix-analyte preparation, to detect in a semiquantitative manner the molecular ions present in the unfractionated NIL homogenate. Comparison of the mass spectra generated from NIL homogenates of salt-loaded and control rats revealed a selective and significant decrease in the intensities of several molecular ion species of the NIL homogenates from salt-loaded rats. These ion species, which have masses that correspond to the masses of oxytocin, vasopressin, neurophysins, and an unidentified putative peptide, were subsequently chemically characterized. We confirmed that the decreased molecular ion species are peptides derived exclusively from propressophysin and prooxyphysin (i.e., oxytocin, vasopressin, and various neurophysins). The putative peptide is carboxyl-terminal glycopeptide. The carbohydrate moiety of the latter peptide was determined by electrospray tandem MS as bisected biantennary Hex3HexNAc5Fuc. This posttranslational modification accounts for the mass difference between the predicted mass of the peptide based on cDNA studies and the measured mass of the mature peptide.

Amino Acid Sequence

Analysis of proteins by direct-scanning infrared-MALDI mass spectrometry after 2D-PAGE separation and electroblotting.

A novel approach is reported for the analysis and identification of proteins separated by 2D-PAGE with scanning infrared matrix-assisted laser desorption/ionization mass spectrometry (scanning IR-MALDI-MS). The proteins of human blood plasma were separated by 2D-PAGE, electroblotted onto PVDF membranes, incubated in matrix solution, and then scanned by IR-MALDI-MS. Mass contour plots of selected spots were obtained. Protein separation is shown to be conserved by comparison with silver-stained gels. The sensitivity for the protein detection is comparable if not better than that of silver-stained gels. Posttranslational modifications were identified by comparing the measured mass to the one calculated from the known DNA sequence. Adduct formation to unprotected cysteine residues during gel separation is demonstrated for selected proteins.

Blood Proteins

Calicheamicin derivatives conjugated to monoclonal antibodies: determination of loading values and distributions by infrared and UV matrix-assisted laser desorption/ionization mass spectrometry and electrospray ionization mass spectrometry.

Calicheamicin derivatives (MW approximately 1500) and monoclonal antibodies (MoAbs) conjugated to calicheamicin derivatives (MW approximately 150,000) were analyzed by UV-MALDI/MS, IR-MALDI/MS, and ESI/MS. These materials are potent anticancer agents. Calicheamicin derivatives and conjugates rapidly degrade upon UV irradiation but are relatively stable during IR irradiation and under ESI conditions. A unique feature of IR-MALDI/MS is a 2 times enhancement in resolution relative to UV-MALDI/MS for masses above approximately 50,000 Da resulting in a molecular ion envelope containing a series of partially resolved peaks of the calicheamicin-MoAb conjugates. The mass shift difference between the peak maxima corresponded to the mass change due to the covalent addition of calicheamicin derivatives to the monoclonal antibody. The distribution of the calicheamicin derivatives in the monoclonal antibodies was computed by deconvoluting the partially resolved peak envelope. A unique feature of the ESI mass spectra, under unit resolution conditions, is that the distribution of the carbohydrates can be well resolved for pure MoAbs and can be only partially resolved for conjugated MoAbs. Average loading values for calicheamicia derivatives when conjugated to MoAbs were computed from UV-MALDI/MS, IR-MALDI/MS, and ESI/MS data and the results compared with the average loading values obtained by UV absorption spectrometry. Very low average loading values were computed from UV-MALDI/MS data due to the degradation of the conjugated calicheamicin derivatives during the UV irradiation process. The IR-MALDI/MS average loading values, obtained with glycerol as the matrix, were consistent with the UV absorption spectrometry values for conjugates having hydrolytically stable linkers, but not when the linker contained a hydrolytically labile hydrazone. ESI/MS average loading values were generally lower than the corresponding values obtained by IR-MALDI/MS. The average loading values and distributions obtained using IR-MALDI/MS were more reliable than the corresponding ESI/MS values because the partially resolved, singly and doubly charged peaks in the IR-MALDI spectra can be mathematically deconvoluted, while the overlapping, highly multiply charged peaks of the electrospray spectra can only be partially deconvoluted.

Aminoglycosides

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI) of endonuclease digests of RNA.

The determination of RNA sequences using base- specific enzymatic cleavages is a well established method. Different synthetic RNA molecules were analyzed for uniformity of degradation by RNase T1, U2, A and PhyM under reaction conditions compatible with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS), to identify the positions of G, A and pyrimidine residues. In order to get a complete set of fragments derived from cleavage at every phosphodiester bond, the samples were also subjected to a limited alkaline hydrolysis. Additionally, the 5'-terminus fragments of a 49mer RNA transcript were isolated by way of 5'-biotinylation and streptavidin-coated magnetic beads (Dynal), followed by a RNase U2digestion. MALDI-MS of the generated fragments is presented as an efficient technique for a direct read out of the nucleotide sequence.

Animals

Matrix-assisted laser desorption/ionisation mass spectrometry of transfer ribonucleic acids isolated from yeast.

tRNATyr and tRNASer purified from bulk brewer's yeast tRNA were subjected to analysis by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry. Choosing a mixture of 2,4,6- and 2,3,4-trihydroxy-acetophenone and diammonium citrate as matrix a mass resolution of up to 220 (FWHM) was achieved in the linear mode of operation. Cation adduct suppression by addition of cation exchange beads and a chelating agent (CDTA) is shown to substantially improve mass resolution for this class of molecules.

RNA, Fungal

Analysis of fructans from higher plants by matrix-assisted laser desorption/ionization mass spectrometry.

In this communication both matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and high-performance anion-exchange chromatography (HPAEC) have been applied to analyze fructans from higher plants. Size distribution of a commercially available fructan preparation from Dahlia variabilis L. was determined by MALDI-MS. Molecular masses ranged from 2,000 up to 6,000 Da with a peak value of distribution at 2,635 Da. Essentially the same pattern was obtained using HPAEC. Low-molecular-weight fructans from onion bulbs (Allium cepa L.) were studied in more detail. Tissue extracts were analyzed by MALDI-MS without any analyte purification. Mass-spectra of both proteins and oligosaccharides were obtained. For identification, metastable ion scanning was performed. Neither deproteinization nor deionization of the samples affected the oligosaccharide pattern. Using HPAEC, a more complex oligosaccharide pattern was obtained because isomeric glycans were differentiated. However, the overall size distribution was similar to that obtained by MALDI-MS. In further experiments epidermal or parenchyma cell layers of the onion bulb were placed into matrix solution and were then subjected to MALDI-MS and metastable ion scanning as well. By taking this approach, analyte desorption was achieved immediately from plant tissue. Oligosaccharide mass spectra were essentially the same as those of the extracts. To our knowledge, this is the first time that MALDI-MS has been applied as a microprobe to plant tissue. Finally MALDI-MS analysis was performed using single-cell extracts from onion tissues without any purification of the analyte.

Allium

Intracellular degradation of C-peptides in molluscan neurons producing insulin-related hormones.

Single Light Green Cells (LGC) of Lymnaea stagnalis, expressing four genes encoding insulin-related peptides (MIPs) and C-peptides, and sections from the median lip nerve (MLN) were subjected to MALDI-MS. Mass spectra of LGCs and MLNs were almost identical. Masses corresponding to those of the MIPs and some C alpha-peptides could be distinguished. ProMIP III C alpha-peptide and C beta-peptides were not found. The spectra showed additional masses matching those of carboxyterminally truncated C alpha-peptides. Peptides with similar masses were isolated from MLN extracts by HPLC, using electrospray-MS screening. Amino acid sequence analysis revealed intact proMIP I, II and V C alpha-peptides and I, II C alpha-peptide 1-24, 1-22 and 1-15.

Amino Acid Sequence

High-sensitivity peptide mapping by micro-LC with on-line membrane blotting and subsequent detection by scanning-IR-MALDI mass spectrometry.

A novel approach to the on-line mass determination of peptides from digested proteins by scanning infrared matrix-assisted laser desorption/ionization (scanning-IR-MALDI) is described. The peptides were continuously collected directly onto a PVDF (polyvinylidene fluoride) strip during a HPLC run. Individual peptides were detected by lining up the PVDF strip with the UV trace from the HPLC run, using visible dye markers as reference points. The local resolution of the peptides on the PVDF membrane is preserved during matrix incubation for MALDI-MS as shown by comparing the UV chromatogram and the total ion current (TIC) from an on-line coupled electrospray ionization (ESI) mass spectrometer with the scanning-IR-MALDI data from the corresponding areas on the PVDF strip. The intensities of the mass profiles obtained by scanning-IR-MALDI reflect the amount of peptides present on the PVDF strip. The higher sensitivity of IR-MALDI-MS yielded mass information not detectable by ESI-MS. After the scanning-IR-MALDI experiment, the same membrane strip can be used directly for automated Edman degradation. Comparable initial and repetitive yields were obtained for blotted peptides with and without matrix incubation.

Chromatography, High Pressure Liquid

Ice as a matrix for IR-matrix-assisted laser desorption/ionization: mass spectra from a protein single crystal.

Lasers emitting in the ultraviolet wavelength range of 260-360 nm are almost exclusively used for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of macromolecules. Reports about the use of lasers emitting in the infrared first appeared in 1990/1991. In contrast to MALDI in the ultraviolet, a very limited number of reports on IR-MALDI have since been published. Several matrices have been identified for infrared MALDI yielding spectra of a quality comparable to those obtained in the ultraviolet. Water (ice) was recognized early as a potential matrix because of its strong O-H stretching mode near 3 microm. Interest in water as matrix derives primarily from the fact that it is the major constituent of most biological tissues. If functional as matrix, it might allow the in situ analysis of macromolecular constituents in frozen cell sections without extraction or exchanging the water. We present results that show that IR-MALDI of lyophilized proteins, air dried protein solutions, or protein crystals up to a molecular mass of 30 kDa is possible without the addition of any separate matrix. Samples must be frozen to retain a sufficient fraction of the water of hydration in the vacuum. The limited current sensitivity, requiring at least 10 pmol of protein for a successful analysis needs to be further improved.

Animals

A peptidoglycan binding domain in the porin-associated protein (PAP) of Rhodospirillum rubrum FR1.

The porin-associated protein of Rhodospirillum rubrum FR1 was found to contain a peptidoglycan binding motif. A partial fragment of 179 amino acids, obtained by cleavage of PAP with trypsin, Asp-N protease, and CNBr, was sequenced. Substantial sequence homology was found of the C-terminal part (residues 126-179) of porin-associated protein with OmpA, the peptidoglycan-associated lipoprotein of several bacteria, protein F of Pseudomonas aeruginosa, and PIII of Neisseria gonorrhoeae, the latter being also a porin-associated protein. The 179 amino acid fragment comprised about 67% of the mass spectrometrically determined total mass of PAP of 27850 Da.

Amino Acid Sequence

Cell-associated glucans of Burkholderia solanacearum and Xanthomonas campestris pv. citri: a new family of periplasmic glucans.

The cell-associated glucans produced by Burkholderia solanacearum and Xanthomonas campestris pv. citri were isolated by trichloroacetic acid treatment and gel permeation chromatography. The compounds obtained were characterized by compositional analysis, matrix-assisted laser desorption ionization mass spectrometry, and high-performance anion-exchange chromatography. B. solanacearum synthesizes only a neutral cyclic glucan containing 13 glucose residues, and X. campestris pv. citri synthesizes a neutral cyclic glucan containing 16 glucose residues. The two glucans were further purified by high-performance anion-exchange chromatography. Methylation analysis revealed that these glucans are linked by 1,2-glycosidic bonds and one 1,6-glycosidic bond. Our 600-MHz homonuclear and 1H-13C heteronuclear nuclear magnetic resonance experiments revealed the presence of a single alpha-1,6-glycosidic linkage, whereas all other glucose residues are beta-1,2 linked. The presence of this single alpha-1,6 linkage, however, induces such structural constraints in these cyclic glucans that all individual glucose residues could be distinguished. The different anomeric proton signals allowed complete sequence-specific assignment of both glucans. The structural characteristics of these glucans contrast with those of the previously described osmoregulated periplasmic glucans.

Burkholderia

Separation and characterisation of bovine histone H1 subtypes by combined ion-exchange and reversed-phase chromatography and mass spectrometry.

In order to separate and identify histone H1 subtypes from calf thymus we used both electrospray mass spectrometry (ES-MS) and matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS) after a three-step chromatographic procedure consisting of reversed-phase high-performance liquid chromatography (RP-HPLC), size-exclusion chromatography (SEC) and ion-exchange chromatography (IEC). Under the RP-HPLC conditions described, we obtained two baseline-separated H1-fractions which were characterised by MALDI-TOF-MS. The determined masses ranged from 22,850 to 22,590 for the first fraction and from 22,070 to 21,250 for the second fraction. Further, it was shown that the first fraction contained at least four and the second one at least five subtypes of the histone class H1. Four homogeneous pure H1 subtypes were obtained by a combination of IEC followed by SEC and RP-HPLC. The molecular masses of these four subtypes determined by ES-MS were 22,606, 22,761, 21,347 and 21,263. We obtained six additional molecular masses of histone H1 subtypes from three heterogeneous fractions, namely 22,066, 21,802, 20,586 and 19,817 by ES-MS and 22,800 and 22,675 by MALDI-TOF-MS. The retention times of these fractions and the molecular masses were in agreement with the data obtained from RP-HPLC fractions by MALDI-TOF-MS.

Animals

7-Deaza purine bases offer a higher ion stability in the analysis of DNA by matrix-assisted laser desorption/ionization mass spectrometry.

Oligodeoxynucleotides which contain 7-deaza analogues of the normal purine nucleotides have been synthesized both enzymatically and chemically. When subjected to matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis, the modified samples offer both higher stability and increased sensitivity compared to otherwise identical unmodified oligodeoxynucleotides. In view of these observations, models for the fragmentation of oligodeoxynucleotides in MALDI-MS with positive ion detection mode are presented. Additionally, the potential use of 7-deaza purine nucleotides in the MALDI-MS analysis of DNA sequencing reactions is discussed.

Base Sequence