Search PubMed⌕ Search

Biomedical subjects

F Gottsauner-Wolf

Publications and source records attributed to F Gottsauner-Wolf.

24 records · Page 2Linked to original sources

[From the nail/plate to the dynamic hip screw--example of a generation change in implants for para-articular femoral fractures].

In trochanteric fractures of the femur, where operative techniques are preferable to conservative treatment, a change in the choice of implants has taken place over the past years. As several comparative studies show, the traditional system of nail/plate fixation has not been completely replaced by Ender nailing in many surgical departments. The system of nail/plate is, however, losing significance in face of the increasing usage of screwing-systems (such as, for instance, DHS of AO-Dynamic Hip Screw). The possibility of compression during the operation in screwing methods is the decisive factor.

Aged↗

[Bone fixation of tumor endoprostheses with cast-on spherules of a cobalt-base alloy].

Special tumor endoprostheses manufactured from cobalt-base alloy with cast-on globules upon the intramedullary shaft and two paracortical flanges for screw fixation can be stabilized at the ends of long bones without using bone cement. Three such implants, retrieved in clinically stable condition after 3 months (proximal tibia), 5 months (distal humerus), and 13 months (distal femur), were investigated microscopically: new bone was found immediately adjacent to the porous surface structures and the fixation screws in many areas. The contribution of bone fragments originating from the preparation of the implant bed to this bone reaction was extremely slight. On the other hand, fibrous tissue layers and a foreign body reaction were found on the remaining surfaces, which may have been related to the compatibility of the implant material and must therefore be regarded as detrimental for the long-term prognosis concerning the fixation of such implants.

Bone Neoplasms↗

[Risk factors for dislocation of a cementless total hip endoprosthesis--a statistical analysis].

AIM: This retrospective study aimed at the statistical identification of risk factors for dislocation for a certain cementless hip endoprothesis. MATERIAL AND METHOD: At our department 2605 primary total hip arthroplasties were performed between 1987 and 1997. In 40 patients (1.5%) a dislocation occurred. These patients were compared with a control group matched in number. RESULTS: No difference was found in both groups with respect to age, height, weight, body-mass index, and diagnosis. A tendency was found that more males were involved in the dislocation group. There were more previous operations found in this group (p = 0.005). Also significant was the fact, that patients in the dislocation group more often had epidural anaesthesia (p = 0.02), more often the implantation of the smaller 28-mm head (vs. 32 mm) (p = 0.02), and a higher inclination angle of the acetabular component (p = 0.02). No difference was found in terms of the surgeons experience, the postoperative leg length, femoral offset, medialisation, cranialisation and antetorsion of the acetabular component. CONCLUSION: Dislocation after total hip arthroplasty is a multifactorial complication. With the use of the Alloclassic/Zweymüller total hip endoprothesis, a higher risk for dislocation was found for patients with previous hip surgery, the use of the smaller endoprosthesis head, a high acetabular inclination angle, and in the use of epidural anaesthesia.

Aged↗

[Six to ten year results of use of the alloclassic hip prosthesis--a multicentre survival analysis].

AIM: This prospective study describes This retrospective multicenter study was undertaken to calculate mid- and long-term survival rates of the cementless Zweymüller/Alloclassic total hip prosthesis. MATERIAL AND METHODS: The rectangular titanium stem and threaded cup have been in use since 1986. The ball head is made of alumina ceramic, the inlay of UHMW polyethylene. Five hospitals in Austria, France and Germany cooperated in the follow-up of 848 patients operated between October 1986 and September 1990 (mean age 62.2 years, 62% women, 38% men, mean patient weight 73.8 kg, body mass index 26.8). 468 patients were followed clinically, 320 patients interviewed on the phone, 29 sent a letter. No information was available concerning the remaining 31 patients. Probabilities of implant survival were estimated with the Kaplan-Meier method. RESULTS: 98 patients (11.5%) had died at a median follow-up time of 81.1 months. The probability of survival at 81.1 months was 98.6% looking at stem and cup. There was no significant association of survival of the prosthesis and patient weight, gender or body mass index. CONCLUSION: Our results are in accordance with previously published data of smaller series using the Zweymüller/Alloclassic( total hip. The survival rate of this cementless rectangular titanium prosthesis for the reported follow-up time compares favorably with contemporary cemented hip prostheses.

Adult↗

[2-to-4-year results of the cementless application of the PCA unicondylar knee prosthesis. Clinico-radiological histomorphological study].

Since 1984 35 PCA unicondylar endoprostheses of the knee joint were implanted due to unicondylar high grade osteoarthritis or Morbus Ahlbäck. 19 endoprostheses with a minimum follow up of two years were investigated. Three implants had to be changed because of an aseptic loosening and were retrieved for histomorphological analysis. The implants which were found clinically stable were graded from the patients point of view as excellent to fair. Only in 5 cases, however, no seam at the implants interface was found in the radiological screening. These radiological lucencies can only be seen in x-ray amplifier controlled x-rays. No correlation has been seen of the clinical performance to the type of anchorage. The position of the implants which had revision was fair in one case and poor in two cases, although a correlation between the radiological seam and the position of the implant was not found. The histological analysis showed up a well developed osseointegration on the femoral component in the area of the porous coated pegs. At the interface to the bone of the tibial components intervening connective tissue has been found. 3 implants still in function have to be seen as endangered to loosening and further 8 prostheses with partial radiolucencies might become potential failures.

Aged↗

Mechanical characteristics of four allograft tendon-to-muscle anastomotic techniques.

Four methods of allograft tendon-to-muscle anastomosis were tested in single cycle distraction to failure using 10 anastomosed ovine calcaneal tendon-biceps brachii units. The tendon-muscle units were compared to intact ovine biceps brachii muscle units. Methods of tendon-to-muscle anastomosis were derived from modifications of existing muscle tendon repair and tenorrhaphy techniques. Load to failure (N), stiffness (N/cm), distraction (cm), and modes of failure were recorded. Of the four methods tested, the side-to-side technique demonstrated the highest load to failure (152.1 N), the greatest stiffness (17.6 N/cm), the least distraction (2.99 cm) before failure, and the least amount of muscle tissue trauma at failure. Results indicate that, of the methods tested, the side-to-side technique offers the greatest initial stability and should therefore allow adequate revascularization and healing of the anastomosis site.

Anastomosis, Surgical↗