Search PubMed⌕ Search

Biomedical subjects

F G Yanowitz

Publications and source records attributed to F G Yanowitz.

27 records · Page 2Linked to original sources

A randomized trial of intracoronary streptokinase in the treatment of acute myocardial infarction.

Fifty patients with acute myocardial infarction were randomly assigned to receive either intracoronary streptokinase or standard (control) therapy within about three hours after the onset of pain. Coronary perfusion was reestablished in 19 of 24 patients receiving streptokinase. Streptokinase alleviated pain (as indicated by differences in subsequent morphine use). The Killip class was significantly improved after therapy with streptokinase, as were changes in radionuclide ejection fraction between Days 1 and 10 in surviving patients (+3.9 vs. -3.0 per cent, P less than 0.01). The echocardiographic wall-motion index also showed greater improvement after streptokinase treatment (P less than 0.01). Streptokinase therapy was associated with rapid evolution of electrocardiographic changes, which were essentially complete within three hours after therapy, but loss of R waves, ST elevation, and development of Q waves in the convalescent period were greater in the control group (P less than 0.01). The time required to reach peak plasma enzyme concentrations was significantly shorter after streptokinase. The incidence of early and late ventricular arrhythmias was not affected by treatment. We conclude that intracoronary streptokinase appears to have a beneficial effect on the early course of acute myocardial infarction.

Adult↗

"Anaerobic threshold": problems of determination and validation.

Despite the popularity of the concept of "anaerobic threshold" (AT), the noninvasive detection criteria remain subjective, and invasive validations of AT have been based on lactate data of arterial, mixed venous, venous, and capillary blood samples without any concern for the possible lactate differences from these sources. Eight normal subjects underwent two exercise tests on a bicycle ergometer. The protocol consisted of 3 min of rest, 3 min of 0 work load, and a 20 W/min ramp (1 W/3 s) until exhaustion. Simultaneous arterial and venous blood samples were drawn during the second test. Noninvasive gas response data were measured using a computerized breath-by-breath stress test system. Threshold phenomenon of the lactate accumulation was not found. The arterial lactate levels increased continuously after the start of the exercise ramp. The rise in venous lactate lagged behind the rise of the arterial lactate by about 1.5 min, and therefore venous lactate was not considered suitable for AT detection. Four independent exercise physiologists determined AT from the gas response data. The reviewer variability (avg range 16%) of AT for a given subject was representative of AT values reported for untrained and trained individuals (40-70% maximum O2 consumption). We concluded that 1) AT is not detectable using invasive methods (arterial and venous lactates); and 2) the noninvasive gas response determination has such a large range of reviewer variability that it is unsuitable for clinical use.

Adult↗

Application of body surface mapping to exercise testing: S-T80 isoarea maps in patients with coronary artery disease.

Body surface electrocardiographic maps were recorded before and after exercise in 25 men with angiographically documented coronary disease. Torso potential distributions at 192 locations were derived from a 32 lead electrode array using methods previously described in our laboratory. The S-T segment was characterized by the spatial distribution of the integral of S-T segment voltage over 80 ms (S-T80). Body surface regions where the S-T80 areas were =8 mV . ms or greater were identified in 18 of 25 patients. The most negative S-T80 site on the map was called the "S-T80 minimum." The S-T80 minima were located 1 or 2 electrode rows away from the standard V4--V6 electrode positions in 6 of 18 patients who developed S-T80 areas of -8 mV . ms or greater. Our data suggest that standard electrocardiographic leads may not be optimal for identifying S-T segment depression in all patients with coronary disease. Furthermore, body surface mapping during exercise provides a more quantitative and qualitative method for characterizing the ischemic response to exercise.

Adult↗

Computerized determination of pneumotachometer characteristics using a calibrated syringe.

A computerized method has been developed to determine the conductance characteristics of pneumotachometers. Conductance values of the flowmeter, which correspond to all pressure values, can be determined by a weighted averaging technique, when multiple strokes of a precision 3-liter calibrated syringe are used. The conductance values then allow the measured differential pressures to be converted, point by point, into flows. The accuracy of measured volumes is within +/- 0.5% for a 100-stroke calibration process, and calibration with 50 strokes provides +/- 1% accuracy. The method improves the accuracy of the on-line measurements of ventilation. O2 consumption, and CO2 production during exercise.

Calibration↗

Noninvasive evaluation of exercise training in college-age men.

The purpose of this study was to assess noninvasively the effects of intense aerobic training on cardiac structure and function in a group of healthy, college-age men (25 experimental and 11 control, mean age 22 years). Echocardiographic, electrocardiographic (ECG), and fitness measurements were obtained before and after a 3-month endurance training program and compared with similar measurements obtained in nonexercising subjects. The supervised training program consisted of 50-minute jogging sessions 5 days a week at 85% of maximal heart rate. Compared with the control group, echocardiography after training showed an increase in left ventricular (LV) end-diastolic dimension (p less than 0.05). LV posterobasal wall thickness, septal wall thickness and ejection fraction did not change significantly. ECG measurements revealed a decrease in resting heart rate (p less than 0.05) and an increase in R-wave voltage in leads V5 and V6 (p less than 0.01). The measured maximal oxygen consumption increased by 16% (p less than 0.001). These data indicate that intense aerobic training in college-age men results in a significant increase in resting LV end-diastolic dimension and volume. The increase in maximal stroke volume associated with exercise training may be partially explained by these changes in cardiac dimensions.

Adipose Tissue↗

Evaluation of a computerized arrhythmia alarm system.

A prospective study of a computerized arrhythmia alarm system was carried out in the coronary care unit during 200 patient hours of monitoring. The computer system was designed to activate an alarm on the development of rhythm and conduction disorders including asystole, ventricular tachycardia, atrial tachycardia, sinus tachtcardia, bradycardia, frequent premature ventricular beats, atrial fibrillation and bundle branch block. Study patients were simultaneously monitored by the computer system and a conventional analog heart rate alarm system. All alarms generated by the two systems were evaluated. Of 79 computer alarms, 42 (53 percent) were true positive alarms; during the same period there were 167 analog alarms of which only 13 (8 percent) were true positive alarms. In both systems, false positive alarms were primarily due to patient movement, but they occurred only 25 percent as often with the computer system as with the analog system. These results indicate that computerized arrhythmia monitoring systems offer significant advantages over conventional monitoring techniques.

Arrhythmias, Cardiac↗

Effects of aminophylline upon the exercise performance of patients with stable chronic airflow obstruction.

To assess the effects of aminophylline upon the exercise performance of patients with chronic airflow obstruction (CAO), we performed ramp exercise tests (1 W/3 s) on six CAO subjects before and after intravenous aminophylline (6 mg X kg-1). The subjects had airflow obstruction (mean FEV1/FVC = 0.53) which did not improve following the inhalation of aerosolized isoetharine. After intravenous aminophylline, maximal oxygen uptake, maximal work rate and exercise duration increased (p less than 0.03) and the subjective dyspnea scores during exercise decreased (p less than 0.05). These changes were not accompanied by increases of FEV1 or peak expiratory flow rate, but maximal inspiratory pressure and peak inspiratory flow rate during exercise increased (p less than 0.05). These observations suggest that aminophylline acutely improves the maximal exercise performance of CAO subjects by mechanisms other than bronchodilation.

Adult↗