Search PubMed⌕ Search

Biomedical subjects

F Eckstein

Publications and source records attributed to F Eckstein.

At least 37 records · Page 2Linked to original sources

Cartilage atrophy in the knees of patients after seven weeks of partial load bearing.

OBJECTIVE: It is currently unknown whether human cartilage properties change during short periods of partial load bearing. We used a post-ankle fracture model to explore whether changes in cartilage morphology occur in the knee under conditions of partial load bearing. METHODS: The knees of 20 patients with Weber type B and type C fractures were examined using magnetic resonance imaging. The first scan was obtained shortly (mean +/- SD 3.2 +/- 3.0 days) after the injury, and a second scan was obtained 7 weeks later (mean +/- SD 50.7 +/- 5.5 days). The morphology (mean and maximum thickness, volume, and surface area) of the patellar, tibial, and femoral cartilage was determined from coronal and axial magnetic resonance images (fat-suppressed gradient-echo). RESULTS: Between week 0 and week 7, the cross-sectional area of the quadriceps muscle was reduced by 11% (P< 0.001). Changes in the mean (+/-SD) cartilage thickness ranged from -2.9 +/- 3.2% in the patella to -6.6 +/- 4.9% in the medial tibia. No significant change in cartilage morphology of the contralateral knee was observed. CONCLUSION: Results of this study demonstrate that in a post-ankle fracture model of partial load bearing, cartilage morphology in all knee compartments is subject to significant change. Changes in the femorotibial joint exceeded those in the patella, whereas no change was observed in the contralateral knee. These findings raise the question of whether cartilage is mechanically less competent and particularly vulnerable after states of partial or complete immobilization.

Adolescent↗

In vivo precision of quantitative shoulder cartilage measurements, and changes after spinal cord injury.

Recent advances in MRI have enabled the quantitative assessment of articular cartilage morphology in human joints. In this study, we tested the hypothesis that the precision of quantitative shoulder cartilage measurements is sufficient to detect changes between and within patients, and that shoulder cartilage thickness in paraplegic patients increases due to increased loading. We imaged the shoulders of seven healthy volunteers four times using a coronal 3D, fat-suppressed, gradient-echo sequence. The humeral head cartilage in seven paraplegic patients was evaluated soon after injury and 1 year post injury. A precision of 4.5% (root mean square (RMS) average coefficient of variation (CV) %) was found for shoulder cartilage thickness measurements in the humeral head. Whereas a significant decrease of cartilage thickness (-11%, P < 0.05) was observed in the knee, there was no significant change in articular cartilage thickness in the shoulder (-1.1%). Our data show, for the first time, that articular cartilage of the humeral head can be quantified with acceptable precision in vivo. It was demonstrated that, in contrast to the knee, the articular cartilage morphology of the humeral head changes very little (i.e., there is no significant increase or decrease in thickness) after spinal cord injury (SCI).

Adaptation, Physiological↗

Technical considerations for microstructural analysis of human trabecular bone from specimens excised from various skeletal sites.

The purpose of this study was to test the effect of repositioning, systematic displacements of the region of interest (ROI), and acquisition parameters (scan mode and integration time) on quantitative analysis of human trabecular bone microstructure at various skeletal sites, using microcomputed tomographic (microCT) technology. We investigated 28 cylindrical specimens of human trabecular bone (length 14 mm, diameter 8 mm) from four skeletal sites (femoral neck, greater trochanter, second lumbar vertebra, and distal radius). These specimens were selected from over 200 microCT measurements, in order to cover a large range of bone volume fraction (BV/TV) observed at each site. Cylindrical ROIs (length 6 mm, diameter 6 mm) were examined twice at an isotropic resolution of 26 microm, 8 weeks apart. In addition, comparative analyses were performed for displacements of the volumes of interest (VOIs) by 1, 2, 3, and 4 mm (83.4%, 66.6%, 50%, and 33.3% overlap), respectively. Eventually, comparative measurements were obtained at different resolution scan modes and integration times. The results show that microCT measurements are highly reproducible (range of the root mean square coefficient variation % (RMS CV%) = 0.64% to 1.29% for BV/TV at different sites). Displacements of the VOI of up to 4 mm generally led to non significant systematic differences in mean values of < 10%. When comparing various combinations of resolution scan modes and integration times, the use of an integration time of 100 ms was found to be preferable for determining microstructural parameters from human samples with this microCT scanner.

Aged↗

The osteoporotic vertebral structure is well adapted to the loads of daily life, but not to infrequent "error" loads.

Osteoporotic vertebral fractures typically have a gradual onset, frequently remain clinically undetected, and do not seem to be related to traumatic events. The osteoporotic vertebrae may therefore be expected to display a less "optimal" bone architecture, leading to an uneven load distribution over the bone material. We evaluated the trabecular load distribution in an osteoporotic and a healthy vertebra under normal daily loading by combining three recent innovations: high resolution computed tomography (microCT) of entire bones, microfinite element analyses (microFEA), and parallel supercomputers. Much to our surprise, the number of highly loaded trabeculae was not higher in the osteoporotic vertebra than in the healthy one under normal daily loads (8% and 9%, respectively). The osteoporotic trabeculae were more oriented in the longitudinal direction, compensating for effects of bone loss and ensuring adequate stiffness for normal daily loading. The increased orientation did, however, make the osteoporotic structure less resistant against collateral "error" loads. In this case, the number of overloaded trabeculae in the osteoporotic vertebra was higher than in the healthy one (13% and 4%, respectively). These results strengthen the paradigm of a strong relationship between bone morphology and external loads applied during normal daily life. They also indicate that vertebral fractures result from actions like forward flexion or lifting, loads that may not be "daily" but are normally not traumatic either. If future clinical imaging techniques would enable such high-resolution images to be obtained in vivo, the combination of microCT and microFEA would produce a powerful tool to diagnose osteoporosis.

Activities of Daily Living↗

Femoro-tibial and menisco-tibial translation patterns in patients with unilateral anterior cruciate ligament deficiency--a potential cause of secondary meniscal tears.

OBJECTIVE: To analyze menisco-tibial and femoro-tibial translation patterns in healthy and ACL-deficient knees in different knee flexion angles under muscle activity. METHODS: The ACL-deficient and contralateral healthy knees of 10 patients were examined with an open MRI system at 30 degrees and 90 degrees of knee flexion, under isometric contraction of the extensors or flexor muscle groups. Translations between the tibia, the femoral condyles and the menisci were analyzed by three-dimensional image postprocessing. RESULTS: Posterior translation of the femur and menisci relative to the tibia occurred during knee flexion (30-90 degrees) in all knees. In ACL-deficient knees, posterior translation of the medial femoral condyle (+1.3 +/- 3.8 mm) was significantly larger than in healthy knee (-0.9 +/- 2.9 mm; p<0.05), while the translation pattern of the menisci was similar (med. meniscus 0.6 +/- 2.3 mm vs. 0.6 +/- 2.7 mm). Under isometric contraction of the extensors (relative to the flexor muscle group), an increased posterior position of the femur and menisci was observed at 30 degrees knee flexion, but not at 90 degrees. This applied to ACL-deficient and healthy knees. CONCLUSIONS: This study shows a significant increase of translation of the medial femoral condyle in ACL-deficient knees, whereas menisco-tibial translation remains almost unchanged. This difference in translation patterns indicates that the posterior horn of the medial meniscus might encounter shear, potentially explaining the high rate of secondary medial meniscal tears in patients with ACL-deficiency.

Adolescent↗

[Multislice-CT for structure analysis of trabecular bone - a comparison with micro-CT and biomechanical strength].

OBJECTIVES: MS-CT (Multislice-Spiral-CT) has a higher spatial resolution compared to the SS-CT (Singleslice-CT). The purpose of this study was to investigate, if the higher spatial resolution of the MS-CT has advantages for structural analyses in the assessment of osteoporosis. MATERIAL AND METHODS: 20 cylindrical trabecular bone specimens (diameter 12 mm, length 15 - 20 mm) were harvested from formalin-fixed human thoracic spines. All specimens were examined by Micro-CT and quantitative, histomorphologic parameters were determined. Analogous structural parameters were calculated from the high-resolution images acquired by both MS- and SS-CT. Additionally, the BMD (bone mineral density) was measured by QCT (quantitative CT). The maximum compressive strength (MCS) was determined in a biomechanical test. The structural parameters were correlated with the histomorphologic parameters and with the MCS. RESULTS: The parameters bone fraction and trabecular separation correlated significantly in both MS- and SS-CT with the analogous parameters from Micro-CT (r (2) = 0.84, p < 0.01) and the MCS (r (2) = 0.81, p < 0.01). The highest correlation with the MCS was calculated using the trabecular number measured by MS-CT in the superior region near the endplate of the vertebra with the high-resolution kernel U90 u (r (2) = 0.85, p < 0.01). This correlation was significantly higher than the correlation between MCS and BMD (r (2) = 0.49, p < 0.01). CONCLUSION: Micro-CT- and MS-CT-determined structural parameters of the trabecular bone showed significant, high correlations. Thus, a characterisation of the trabecular structure seems to be possible. The biomechanical stability of the bone can also be predicted well. The structural parameters acquired by MS-CT show higher correlations with the MCS than the BMD or structural parameters determined by SS-CT do. In this study MS-CT was best suited to predict biomechanical strength of trabecular bone.

Aged↗

Correlation and sex differences between ankle and knee cartilage morphology determined by quantitative magnetic resonance imaging.

OBJECTIVE: To study the correlation between ankle and knee cartilage morphology to test the hypothesis that knee joint cartilage loss in gonarthritis can be estimated retrospectively using quantitative MRI analysis of the knee and ankle and established regression equations; and to test the hypothesis that sex differences in joint surface area are larger in the knee than the ankle, which may explain the greater incidence of knee osteoarthritis in elderly women than in elderly men. METHODS: Sagittal MR images (3D FLASH WE) of the knee and hind foot were acquired in 29 healthy subjects (14 women, 15 men; mean (SD) age, 25 (3) years), with no signs joint disease. Cartilage volume, thickness, and joint surface area were determined in the knee, ankle, and subtalar joint. RESULTS: Knee cartilage volumes and joint surface areas showed only moderate correlations with those of the ankle and subtalar joint (r = 0.33 to 0.81). The correlations of cartilage thickness between the two joints were weaker still (r = -0.05 to 0.53). Sex differences in cartilage morphology at the knee and the ankle were similar, with surface areas being -17.5% to -23.5% lower in women than in men. CONCLUSIONS: Only moderate correlations in cartilage morphology of healthy subjects were found between knee and ankle. It is therefore impractical to estimate knee joint cartilage loss a posteriori in cross sectional studies by measuring the hind foot and then applying a scaling factor. Sex differences in cartilage morphology do not explain differences in osteoarthritis incidence between men and women in the knee and ankle.

Adult↗

Image-based micro-finite-element modeling for improved distal radius strength diagnosis: moving from bench to bedside.

Although osteoporosis is characterized by quantitative (mass) and qualitative (structural) changes, standard clinical techniques (dual-energy X-ray absorptiometry, DXA) only measure the former. Three-dimensional micro-finite-element (micro-FE) models based on high-resolution images can account for structural aspects as well, and it has recently been shown that an improved prediction of distal radius strength is possible with micro-FE analysis. A clinical application of this technique, however, is limited by its high imaging and computational demands. The objective of this study is to investigate if an improved prediction of bone strength can be obtained as well when only a small part of the radius is used for micro-FE modeling. Images of a 1-cm region of the metaphysis of the distal radius of 54 cadaver arms (mean age: 82 +/- 9 SD) made with a three-dimensional peripheral quantitative computed tomography (pQCT) device at 165- micro m resolution formed the basis for micro-FE models that were used to predict the bone failure load. Following imaging, specimens were experimentally compressed to failure to produce a Colles'-type fracture. Failure loads predicted from micro-FE analyses agreed well with those measured experimentally (R2 = 0.66, p < 0.001). Lower correlations were observed with bone mass (R2 = 0.48, p < 0.001) and microstructural parameters (R2 = 0.47, p < 0.001). Hence, even when only a small region is modeled, micro-FE analysis provides an improved prediction of radius strength.

Absorptiometry, Photon↗

Feasibility of T and Z scores from magnetic resonance imaging data for quantification of cartilage loss in osteoarthritis.

OBJECTIVE: T scores (an indicator of the difference between patients and young healthy subjects) and Z scores (an indicator of the difference between patients and age-matched healthy subjects) are used in the diagnosis of osteoporosis and form the current basis for the definition of osteoporosis by the World Health Organization. We tested the feasibility of using T and Z scores derived from quantitative cartilage imaging with magnetic resonance imaging (MRI) for the diagnosis of osteoarthritis (OA). METHODS: High-resolution MR images of tibial cartilage were acquired from 126 young healthy adults (ages 20-35 years), 24 age-matched elderly healthy adults (ages 50-75 years), 7 OA patients prior to tibial osteotomy, and 7 OA patients prior to knee arthroplasty. Cartilage volume, thickness, surface area, and original joint surface area (before onset of disease) were determined in the medial and lateral tibia. RESULTS: The cartilage volume of the medial tibia of osteotomy patients with varus malalignment displayed moderate T scores (-1.0), and more negative T scores (-3.8) were observed in knee arthroplasty patients with varus malalignment. Normalization of the cartilage volume to the original joint surface area substantially enhanced the scores in patients undergoing osteotomy (-2.3) and in patients undergoing knee arthroplasty (-5.5), and this was superior to the normalization ratios of cartilage volume to body height and cartilage volume to body weight, in terms of distinguishing the loss of articular cartilage. CONCLUSION: Quantitative analysis of OA by MRI is feasible using T and Z scores. However, cartilage volume should be normalized to the individual joint surface area in order to maximize the discriminatory power of this technique for the diagnosis of OA.

Adult↗

Longitudinal analysis of cartilage atrophy in the knees of patients with spinal cord injury.

OBJECTIVE: A previous cross-sectional study indicated that the morphology of patellar and tibial cartilage is subject to change after spinal cord injury (SCI). The aim of this study was to perform a longitudinal analysis of cartilage atrophy in all knee compartments, including the femoral condyles, in SCI patients over 12 months. METHODS: The right knees of 9 patients with complete, traumatic SCI were examined shortly after the injury (mean +/- SD 9 +/- 4 weeks) and at 6 and 12 months postinjury. Three-dimensional morphology of the patellar, tibial, and femoral cartilage (mean and maximum thickness, volume, and surface area) was determined from coronal and transversal magnetic resonance images (fat-suppressed gradient-echo sequences) using validated postprocessing techniques. RESULTS: The mean thickness of knee joint cartilage decreased significantly during the first 6 months after injury (range 5-7%; P < 0.05). The mean change at 12 months was 9% in the patella, 11% in the medial tibia, 11% in the medial femoral condyle, 13% in the lateral tibia, and 10% in the lateral femoral condyle (P < 0.05 for all compartments). CONCLUSION: This is the first report of a longitudinal analysis of cartilage atrophy in patients with SCI. These data show that human cartilage atrophies in the absence of normal joint loading and movement after SCI, with a rate of change that is higher than that observed in osteoarthritis (OA). A potential clinical implication is that cartilage thinning after SCI may affect the stress distribution in the joint and render it vulnerable to OA. Future studies should focus on whether specific exercise protocols and rehabilitation programs can prevent cartilage thinning.

Adolescent↗

Validation of cartilage volume and thickness measurements in the human shoulder with quantitative magnetic resonance imaging.

OBJECTIVE: To validate quantitative magnetic resonance imaging (qMRI) for the assessment of cartilage volume and thickness in thin and curved cartilage layers, such as the shoulder. METHODS: Eight shoulder specimens from healthy individuals (aged 31-69 years) were investigated using a 3D gradient echo sequence with selective water excitation. After segmentation with a B-spline Snake algorithm, the cartilage volume and thickness were determined three dimensionally. The cartilage volume data were compared with water displacement of surgically removed tissue, and the thickness with A-mode ultrasound. RESULTS: The glenoid and humeral head cartilage volume from qMRI agreed highly with that from water displacement (systematic difference, +/-1 to +/-3%; absolute difference, 4 to 7%). For the cartilage thickness, the mean systematic difference ranged from -17% (mean cartilage thickness of the glenoid) to +7% (maximal cartilage thickness of the glenoid); the standard error of the estimate was 3.7% for the humeral head, and 6.4% for the glenoid. CONCLUSIONS: The applied technique can be used for accurate determination of cartilage volume and thickness in human joints with highly curved and thin cartilage layers, such as the shoulder. In vivo application of this method will depend on the development of efficient surface coils that allow high resolution imaging under in situ conditions.

Adult↗

Impact of bone density on distal radius fracture patterns and comparison between five different fracture classifications.

OBJECTIVE: To investigate the impact of bone mineral density (BMD) and bone geometry on failure loads and fracture patterns of the distal radius and to compare 5 different fracture classifications. DESIGN: Biomechanical and radiologic in vitro study. SETTING: Research laboratory. MAIN OUTCOME MEASUREMENTS: A total of 118 intact human forearms from elderly donors were examined by means of conventional radiography and peripheral quantitative computed tomography (PQCT) to determine BMD and geometry. The forearms were subjected to a standardized biomechanical test simulating a fall on the outstretched hand. The distal radius fractures were classified from x-rays using the AO ( 33), Cooney ( 9), Fernandez ( 15), Frykman ( 17), and Melone ( 31) classifications. The grading was repeated after preparation and direct visual inspection of the fracture site and was correlated with radiographic results. Fracture patterns also were correlated with BMD and geometry. RESULTS: Correlations between bone properties and fracture patterns (r = 0.09-0.70) suggested an increase in the severity of fractures with decreasing bone quality. The highest correlation between failure load and bone properties was found for the cortical area (r = 0.70) and trabecular density (r = 0.60). Good correlations between radiographic and direct visual classification were obtained for the Cooney ( 9) (r = 0.70), the AO ( 33) (r = 0.68), and the Fernandez ( 15) (r = 0.65) classifications. Smaller values were found for the Frykman ( 17) (r = 0.44) and the Melone ( 31) (r = 0.27) classifications. CONCLUSIONS: With increasing osteopenia, the load to failure decreases, and the severity of fractures increases. Fracture patterns in this patient population can be adequately graded with the AO ( 33) and Cooney ( 9) classifications. The severity of distal radius fractures tends to be underestimated by conventional x-ray examination, which needs to be taken into account when a fracture treatment plan is selected.

Aged↗

Trabecular bone tissue strains in the healthy and osteoporotic human femur.

UNLABELLED: Quantitative information about bone tissue-level loading is essential for understanding bone mechanical behavior. We made microfinite element models of a healthy and osteoporotic human femur and found that tissue-level strains in the osteoporotic femoral head were 70% higher on average and less uniformly distributed than those in the healthy one. INTRODUCTION: Bone tissue stresses and strains in healthy load-adapted trabecular architectures should be distributed rather evenly, because no bone tissue is expected to be overloaded or unused. In this study, we evaluate this paradigm with the use of microfinite element (microFE) analyses to calculate tissue-level stresses and strains for the human femur. Our objectives were to quantify the strain distribution in the healthy femur, to investigate to what extent this distribution is affected by osteoporosis, to determine if osteoporotic bone is simply bone adapted to lower load levels, and to determine the "safety factor" for trabecular bone. MATERIALS AND METHODS: microFE models of a healthy and osteoporotic proximal femur were made from microcomputed tomography images. The models consisted of over 96 and 71 million elements for the healthy and osteoporotic femur, respectively, and represented their internal and external morphology in detail. Stresses and strains were calculated for each element and their distributions were calculated for a volume of interest (VOI) of trabecular bone in the femoral head. RESULTS: The average tissue-level principal strain magnitude in the healthy VOI was 304 +/- 185 microstrains and that in the osteoporotic VOI was 520 +/- 355 microstrains. Calculated safety factors were 8.6 for the healthy and 4.9 for the osteoporotic femurs. After reducing the force applied to the osteoporotic model to 59%, the average strain compared with that of the healthy femur, but the SD was larger (208 microstrains). CONCLUSIONS: Strain magnitudes in the osteoporotic bone were much higher and less uniformly distributed than those in the healthy one. After simulated joint-load reduction, strain magnitudes in the osteoporotic femur were very similar to those in the healthy one, but their distribution is still wider and thus less favorable.

Aged↗

Knee cartilage of spinal cord-injured patients displays progressive thinning in the absence of normal joint loading and movement.

OBJECTIVE: Alterations in the morphologic, biochemical, and mechanical properties of cartilage occur after unloading and immobilization in animals. However, the findings have been inconsistent and it is unclear whether such changes also take place in humans. This study tested the hypothesis that progressive thinning of knee joint cartilage is observed after spinal cord injury. METHODS: In this in vivo study, knee cartilage was assessed in patients with complete, traumatic spinal cord injury at 6 (n = 9), 12 (n = 11), and 24 months (n = 6) after injury. Morphologic parameters of the knee cartilage (mean and maximum thickness as well as surface area) were computed from magnetic resonance imaging (MRI) data, and results were compared with those in young, healthy volunteers (n = 9). RESULTS: After 6 months of injury, the mean articular-cartilage thickness was significantly less in the patella and medial tibia (decrease of 10% and 16%, respectively; P < 0.05), but not in the lateral tibia (decrease of 10%), compared with the MRI findings in healthy volunteers. After 12 and 24 months of injury, the differences amounted to a reduction of 21% and 23%, respectively, in the patella, 24% and 25%, respectively, in the medial tibia, and 16% and 19%, respectively, in the lateral tibia. The changes were significant in all 3 surfaces of the spinal cord-injured joint cartilage (P < 0.05-0.01). CONCLUSION: Our data show, for the first time, that progressive thinning (atrophy) of human cartilage occurs in the absence of normal joint loading and movement. This may have important implications for patient management, in particular for spinal cord-injured patients and patients who are immobilized after surgery.

Adult↗

[Quantitative cartilage analysis with magnetic resonance tomography (qMRI)--a new era in arthrosis diagnosis?].

Magnetic resonance imaging (MRI) is a new and very powerful method for the diagnostics and monitoring of osteoarthritis. Its advantage is that all articular tissues can be visualized directly and are accessible for three-dimensional analysis. This article reviews qualitative, semi-quantitative, and quantitative studies on articular cartilage with MRI. In particular we discuss pulse sequences and three-dimensional postprocessing methods for quantitative analysis of cartilage volume and thickness, along with their accuracy and precision in healthy volunteers and patients with osteoarthritis. It addition, we present approaches for quantitative analyses of structural/biochemical parameters and for the deformational behavior of cartilage in vivo.

Cartilage, Articular↗

Developments in RNA chemistry, a personal view.

This review describes some of the contributions of chemistry to the RNA field with a personal bias towards the phosphorothioate modification and the derivatives at the ribose 2'-position. The usefulness of these modifications is discussed and documented with some examples.

Animals↗

Mechanical strength of the proximal femur as predicted from geometric and densitometric bone properties at the lower limb versus the distal radius.

This experimental study compares geometric and densitometric properties of cortical and trabecular bone at the lower limb and the distal radius with those at the femoral neck, and evaluates their ability to predict mechanical failure loads of the proximal femur. One hundred five cadavers were examined with peripheral quantitative computed tomography (LpQCT), with measurements being performed in situ at the distal radius (4%, 20%, 33%), at the distal and proximal tibia, at the tibial and femoral shaft, and at the distal femur. Ex situ measurements were obtained at the femoral neck and at the proximal femoral shaft. Pairs of femora were mechanically tested in a vertical loading and a side impact (fall) configuration. The total (cross-sectional) bone mineral content and trabecular density, but not the cortical properties, displayed a higher association between the femoral neck and the peripheral lower limb than between the neck and the distal radius. Approximately 50%-60% of the variability of femoral failure loads (and >80% of trochanteric side impact fractures) were predicted by in vitro measurements at the neck. Geometric cortical parameters and density contributed independently and significantly to femoral strength. Measurements at the peripheral skeleton explained, however, only 30%-45% of the variability of femoral failure, with no significant difference between the lower limb and the distal radius. At peripheral sites, a combination of geometric and densitometric variables was slightly superior to bone mineral content alone in predicting failure in vertical loading, but this was less evident for cervical side impact fractures. The results show that a stronger association of total bone mineral content and trabecular density between the femoral neck and the lower limb does not translate into improved prediction of femoral strength from measurements at the lower limb vs. those at the distal radius.

Aged↗

Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images.

There is increasing evidence that, in addition to bone mass, bone microarchitecture and its mechanical load distribution are important factors for the determination of bone strength. Recently, it has been shown that new high-resolution imaging techniques in combination with new modeling algorithms based on the finite element (FE) method can account for these additional factors. Such models thus could provide more relevant information for the estimation of bone failure load. The purpose of the present study was to determine whether results of whole-bone micro-FE (microFE) analyses with models based on three-dimensional peripheral quantitative computer tomography (3D-pQCT) images (isotropic voxel resolution of 165 microm) could predict the failure load of the human radius more accurately than results with dual-energy X-ray absorptiometry (DXA) or bone morphology measurements. For this purpose, microFE models were created using 54 embalmed cadaver arms. It was assumed that bone failure would be initiated if a certain percentage of the bone tissue (varied from 1% to 7%) would be strained beyond the tissue yield strain. The external force that produced this tissue strain was calculated from the FE analyses. These predictions were correlated with results of real compression testing on the same cadaver arms. The results of these compression tests were also correlated with results of DXA and structural measurements of these arms. The compression tests produced Colles-type fractures in the distal 4 cm of the radius. The predicted failure loads calculated from the FE analysis agreed well with those measured in the experiments (R(2) = 0.75 p < 0.001). Lower correlations were found with bone mass (R(2) = 0.48, p < 0.001) and bone structural parameters (R(2) = 0.57 p < 0.001). We conclude that application of the techniques investigated here can lead to a better prediction of the bone failure load for bone in vivo than is possible from DXA measurements, structural parameters, or a combination thereof.

Aged↗