Search PubMed⌕ Search

Biomedical subjects

F E Regnier

Publications and source records attributed to F E Regnier.

At least 19 recordsLinked to original sources

Spinning-disk self-referencing interferometry of antigen-antibody recognition.

A gold ridge microstructure fabricated to a height of lambda/8 on a high-reflectivity substrate behaves as a wave-front-splitting self-referencing interferometer in phase quadrature when illuminated by a Gaussian laser beam and observed in the far field along the optic axis. When immuno-gammaglobulin (IgG) antibodies are selectively immobilized on the gold microstructure, they recognize and bind to a specific antigen, which shifts the relative optical phase of the interferometer and modifies the far-field diffracted intensity. We detect bound antigen interferometrically on spinning disks at a sampling rate of 100 kHz and verify the interferometric nature of the signal by using two quadratures of opposite sign to rule out effects of dynamic light scattering. Strong molecular recognition is demonstrated by the absence of binding to nontarget molecules but strong signal change in response to a specific antigen. This BioCD has the potential to be applied as a spinning-disk interferometric immunoassay and biosensor.

Animals↗

Fractionation of isotopically labeled peptides in quantitative proteomics.

The goal of quantitative proteomics is to examine the expression levels of all of the proteins in a biological system and recognize those that change as a function of some stimulus. Quantification is now frequently based on derivatization of peptides with isotopically distinguishable labeling agents. This study examines the extent to which isotopic forms of peptides having the same amino acid sequence are resolved by reversed-phase chromatography and assesses the degree to which resolution of these isotopically different forms of a peptide impact quantification. Three derivatizing agents were examined, the do and d3 forms of N-acetoxysuccinimide, the do and d4 forms of succinic anhydride, and the do and d8 forms of the commercial ICAT reagent Peptide mixtures from control and experimental samples were derivatized individually, mixed, subjected to reversed-phase chromatography, and analyzed by ESI-MS. When partial resolution of the isotopic forms of a peptide occurs, the largest error in assessing the true isotope ratio in a sample occurs when sampling at the extremes of a peak. Early in the elution of a peak, the sample will be enriched in the deuterated species, whereas the opposite is true at the tailing edge of a peak. Acetylated peptides showed the lowest degree of separation. Resolution of the deuterated and nondeuterated forms in this case was 0.023. This amounts to slightly over a 1-s difference in their peak maxima and can cause a typical error of +/- 6% at the leading and tailing edges of a peak. In contrast, resolution of the deuterated and nondeuterated forms of the ICAT reagent were calculated to be 0.45. This means that in a peak of 1-min width (W1/2), the peak maxima will vary by approximately 30 s, and measurement errors of -83 and +500% can occur at the leading and tailing edges of a peak. It is concluded that resolution of isotopic forms of a peptide can cause substantial quantification errors in quantitative proteomics.

Angiotensin I↗

Automated signature peptide approach for proteomics.

This paper addresses the issue of automating the multidimensional chromatographic, signature peptide approach to proteomics. Peptides were automatically reduced and alkylated in the autosampler of the instrument. Trypsin digestion of all proteins in the sample was then executed on an immobilized enzyme column and the digest directly transferred to an affinity chromatography column. Although a wide variety of affinity columns may be used, the specific column used in this case was a Ga(III) loaded immobilized metal affinity chromatography (IMAC) column. Ga(III)-IMAC is known to select phosphorylated peptides. Phosphorylated peptides selected by the affinity column from tryptic digests of milk were automatically transferred to a reversed-phase liquid chromatography (RPLC) column. Further fractionation of tryptic peptides on the RPLC column was achieved with linear solvent gradient elution. Effluent from the RPLC column was electrosprayed into a time-of-flight mass spectrometer. The entire process was controlled by software in the liquid chromatograph. With slight modification, it is possible to add multiple columns in parallel at any of the single column positions to further increase throughput. Total analysis time in the tandem column mode of operation was under 2 h.

Automation↗

Channel-specific coatings on microfabricated chips.

This paper reports channel-specific immobilization of fluorescein-5-isothiocyanate (FITC)-labeled bovine serum albumin and beta-galactosidase on microchips with a central channel and two crossing channels; referred to as a double cross channel configuration. Solvent wells at the termini of all channels were used to store reagents. Coatings were applied in multiple steps using electroosmotically driven flow to deliver reagents to specific channels in the chip. The first step in all coating reactions was derivatization of the capillary walls with an organosilane having a reactive pendant functional group. As the silylating reagent was transported from the reagent storage well to a specific waste well, capillary walls in the route of transport were silylated. Flow was maintained throughout a reaction. The route of transport, and thus the specificity of channel coating, were controlled by the well to which negative potential was applied. Flow in a multichannel network takes the shortest route between the electrodes delivering the motive potential. The second reagent in the reaction was delivered from a different well and took a different path through the channel network, as did other reagents. Only the channel being coated was in the flow path of all the reagents used in the coating process. The zone of immobilization in the case of FITC-labeled albumin was determined with confocal fluorescence microscopy. Enzyme activity of immobilized beta-galactosidase (beta-Gal) was monitored by following the hydrolysis of fluorescein mono-beta-D-galactopyranoside to fluorescein with laser-induced fluorescence.

Bioreactors↗

Proteomics based on selecting and quantifying cysteine containing peptides by covalent chromatography.

This paper describes a procedure in which cysteine containing peptides from tryptic digests of complex protein mixtures were selected by covalent chromatography based on thiol-disulfide exchange. identified by mass spectrometry, and quantified by differential isotope labeling. Following disruption of disulfide bridges with 2,2'-dipyridyl disulfide, all proteins were digested with trypsin and acylated with succinic anhydride. Cysteine containing peptides were then selected from the acylated digest by disulfide interchange with sulfhydryl groups on a thiopropyl Sepharose gel. Captured cysteine containing peptides were released from the gel with 25 mM dithiothreitol (pH 7.5) containing 1 mM (ethylenedinitrilo)tetraacetic acid disodium salt and alkylated with iodoacetic acid subsequent to fractionation by reversed-phase liquid chromatography (RPLC). Fractions collected from the RPLC column were analyzed by matrix-assisted laser desorption ionization mass spectrometry. Based on isotope ratios of peptides from experimental and control samples labeled with succinic and deuterated succinic anhydride, respectively, it was possible to determine the relative concentration of each peptide species between the two samples. Peptides obtained from proteins that were up-regulated in the experimental sample were easily identified by an increase of the relative amount of the deuterated peptide. The results of these studies indicate that by selecting cysteine containing peptides, the complexity of protein digest could be reduced and database searches greatly simplified. When coupled with the isotope labeling strategy for quantification it was possible to determine proteins that were up-regulated in plasmid bearing Escherichia coli when expression of plasmid proteins was induced. Up-regulation of several proteins of E. coli origin was also noted.

Alkylation↗

A picoliter-volume mixer for microfluidic analytical systems.

Mixing confluent liquid streams is an important, but difficult operation in microfluidic systems. This paper reports the construction and characterization of a 100-pL mixer for liquids transported by electroosmotic flow. Mixing was achieved in a microfabricated device with multiple intersecting channels of varying lengths and a bimodal width distribution. All channels running parallel to the direction of flow were 5 microm in width whereas larger 27-microm-width channels ran back and forth through the parallel channel network at a 45 degrees angle. The channel network composing the mixer was approximately 10 microm deep. It was observed that little mixing of the confluent solvent streams occurred in the 100-microm-wide, 300-microm-long mixer inlet channel where mixing would be achieved almost exclusively by diffusion. In contrast, after passage through the channel network in the approximately 200-microm-length static mixer bed, mixing was complete as determined by confocal microscopy and CCD detection. Theoretical simulations were also performed in an attempt to describe the extent of mixing in microfabricated systems.

Algorithms↗

Proteolysis of whole cell extracts with immobilized enzyme columns as part of multidimensional chromatography.

This paper describes the efficacy of immobilized trypsin columns in the digestion of cellular extracts that contained thousands of proteins. Effectiveness of proteolysis was evaluated with extracts of Escherichia coli by size-exclusion chromatography. Immobilized trypsin columns were operated in either the continuous-flow or stopped-flow mode at temperatures ranging from ambient to 37 degrees C with incubation times of 0-2 h. The results of these studies indicate that reduced and alkylated extracts of proteins from E. coli can be digested in 20 min when the enzyme column is operated at elevated temperature. The advantage of immobilized enzyme columns is that they can be easily incorporated into multidimensional separation systems for automated proteomics.

Cell Extracts↗

Detoxification of endotoxin by aluminum hydroxide adjuvant.

Langmuir adsorption isotherms of endotoxin and aluminum-containing adjuvants at pH 7.4 and 25 degrees C revealed that aluminum hydroxide adjuvant has a greater adsorption capacity (283 microg/mg Al) and adsorption coefficient (1.3x10(4) ml/miccrog) than aluminum phosphate adjuvant (3.0 microg/mg Al, 0.20 ml/microg). The difference in endotoxin adsorption was related to two adsorption mechanisms: electrostatic attraction and covalent bonding. The isoelectric point (iep) of endotoxin is approximately 2. An electrostatic attractive force will be present with aluminum hydroxide adjuvant (iep=11.4), and an electrostatic repulsive force will operate with aluminum phosphate adjuvant (iep=4.6). Endotoxin contains two phosphate groups in the lipid A portion. Covalent bonding occurs with surface aluminum in aluminum hydroxide adjuvant but is inhibited by surface phosphate in aluminum phosphate adjuvant. In-vitro desorption experiments using components of interstitial fluid showed that endotoxin adsorbed by aluminum hydroxide adjuvant was not desorbed by interstitial anions (5 mM phosphate or 2.7 mM citrate) or interstitial proteins (25 mg albumin/ml). The effect of aluminum-containing adjuvants on the systemic response of Sprague-Dawley rats to a 15 microg/kg subcutaneous dose of endotoxin was determined by measuring the serum concentration of tumor necrosis factor-alpha (TNF-alpha) and interleukin-6 (IL-6). TNF-alpha and IL-6 were observed in the group which received an endotoxin solution or endotoxin and aluminum phosphate adjuvant. No TNF-alpha or IL-6 was detected in the group that received endotoxin and aluminum hydroxide adjuvant. Aluminum hydroxide adjuvant detoxifies endotoxin by adsorbing it in the vaccine and then not releasing it in interstitial fluid upon administration.

Adjuvants, Immunologic↗

Electrophoretically mediated microanalysis of beta-galactosidase on microchips.

Electrophoretically mediated microanalysis (EMMA) is a method of accomplishing chemical analyses, typically in an open-tubular capillary, due to the difference in the electrophoretic mobility between the particular reagents. This work reports on combining this technique onto microfabricated systems. Two methods of this technique were applied, constant potential and zero potential EMMA onto chips. A dosage response curve was run using this constant potential mode that resulted in a linear response over three orders of substrate concentration magnitude. The chemical system used here is beta-galactosidase (beta-Gal) as the enzyme and fluorescein mono-beta-D-galactopyranoside (FMG) as the substrate. The zero potential mode was used to amplify product turnover using various incubation times. Using this technique and a 10 min incubation, approximately 40000 enzyme molecules could be detected. The zero potential mode is also used in conjunction with an internal standard to show how one can quantitate using this method. The power and ease of utility of this technique is described.

Electrophoresis, Capillary↗

Electrophoretically mediated microanalysis of leucine aminopeptidase using two-photon excited fluorescence detection on a microchip.

Two-photon excited fluorescence detection was performed on a microfabricated electrophoresis chip. A calibration curve of the fluorescent tag beta-naphthylamine was performed, resulting in a sensitivity of 2.5 x 10(9) counts M(-1) corresponding to a detection limit of 60 nM. Additionally, leucine aminopeptidase was assayed on the chip using electrophoretically mediated microanalysis. The differential electroosmotic mobilities of the enzyme and substrate, L-leucine beta-naphthylamide, allowed for efficient mixing in an open channel, resulting in the detection of a 30 nM enzyme solution under constant potential. A zero potential incubation for 1 min yielded a calculated detection limit of 4 nM enzyme.

Animals↗

The impact of buffers and surfactants from micellar electrokinetic chromatography on matrix-assisted laser desorption ionization (MALDI) mass spectrometry of peptides. Effect of buffer type and concentration on mass determination by MALDI-time-of-flight mass spectrometry.

This paper describes the effect of various buffers, surfactants, and organic additives commonly encountered in capillary zone electrophoresis and micellar electrokinetic chromatography on the molecular weight determination of peptides by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Signal-to-noise ratio generally decreased with increasing buffer concentration without affecting mass accuracy, but the type of buffer was also important. Good spectra were obtained with an ammonium acetate buffer up to a concentration of 500 mM without impacting ionization of either peptides or other mobile phase constituents. Ionization of organic additives, such as anionic surfactants, non-ionic surfactants, and cyclodextrins was buffer dependent and presented a problem when the mass of the additive was in the range of the peptide mass. Brij-35, Tween-80, and cyclodextrins all produced prominent spectra of their own in the presence of sodium or potassium containing buffers, but not with ammonium acetate. Cationization of these neutral species with sodium or potassium ions allowed them to acquire a positive charge and produce spectra. In contrast, the ammonium ion appears to be a poor cationizating agent. Ionization of neutral surfactants was suppressed in ammonium acetate without impacting the spectra of peptides. Ammonium acetate buffers containing 30 mM sodium dodecyl phosphate also gave spectra with good signal intensity and no interference from the surfactant. Suppression of peptide ionization in MALDI was a problem when methanol, tetrabutyl amine, or poly(vinyl alcohol) were used with either ammonium acetate, sodium phosphate, and N-(2-hydroxyethyl)piperazine-N-(2-ethansulfonic acid).

Buffers↗

Signature-peptide approach to detecting proteins in complex mixtures.

The objective of the work presented in this paper was to test the concept that tryptic peptides may be used as analytical surrogates of the protein from which they were derived. Proteins in complex mixtures were digested with trypsin and classes of peptide fragments selected by affinity chromatography, lectin columns were used in this case. Affinity selected peptide mixtures were directly transferred to a high-resolution reversed-phase chromatography column and further resolved into fractions that were collected and subjected to matrix-assisted laser desorption ionization (MALDI) mass spectrometry. The presence of specific proteins was determined by identification of signature peptides in the mass spectra. Data are also presented that suggest proteins may be quantified as their signature peptides by using isotopically labeled internal standards. Isotope ratios of peptides were determined by MALDI mass spectrometry and used to determine the concentration of a peptide relative to that of the labeled internal standard. Peptides in tryptic digests were labeled by acetylation with acetyl N-hydroxysuccinimide while internal standard peptides were labeled with the trideuteroacetylated analogue. Advantages of this approach are that (i) it is easier to separate peptides than proteins, (ii) native structure of the protein does not have to be maintained during the analysis, (iii) structural variants do not interfere and (iv) putative proteins suggested from DNA databases can be recognized by using a signature peptide probe.

Amino Acid Sequence↗

Analysis of channel-geometry effects on separation efficiency in rectangular-capillary electrochromatography columns.

A three-dimensional random walk model was developed to evaluate the impact of column geometry on separation efficiency in chromatography systems driven by electroosmotic flow. Contributions of injection plug length, cross-sectional area of channels, and aspect ratio of rectangular channels were examined in these simulation studies. Sample plug length had no impact on efficiency until it exceeded roughly 0.4% of the channel length. Plate height increased rapidly with increasing k' as expected, almost doubling in going from k'=0.25 to 0.35. Channel geometry also had a major effect on efficiency. Plate height increased sharply in rectangular channel columns until the channel aspect ratio reached 4-8. But the effect of channel depth was even more dramatic. Minimum plate height (Hmin) was roughly half that of the channel depth in ideal cases. Hmin in a 10x2 microm channel was at 1.6 mm s(-1). Rectangular channels comparable to those obtained by microfabrication are equivalent to packed column capillary electrochromatography columns in all cases.

Algorithms↗

Eliminating disulfide exchange during glutamyl endopeptidase digestion of native protein.

Numerous advantages of using immobilized enzymes over free-solution protein digests have been cited in the literature. This investigation examines both the rate of hydrolysis and the extent of disulfide bond exchange in disulfide bridged dipeptide fragments formed during proteolysis of native protein. Glutamyl endopeptidase as both an immobilized enzyme and in free solution was used in these studies. It was found that extensive hydrolysis of insulin was achieved in 2 min with immobilized enzyme cartridges operated in the stopped-flow mode orders. This is orders of magnitude faster than was seen in free solution. Other advantages ranging from ease of use and reduction in sample size to the potential for automation were also noted with the immobilized enzyme cartridge. Normal free-solution proteolysis generally requires 12-24 h, based on the lower enzyme-to-substrate ratio in solution. A disturbing feature noted in these lengthy free-solution reactions was the tendency to form disulfide bridged peptide artifacts. This could lead to the erroneous conclusion that disulfide bonding in a sample was not that of the native protein. It is concluded that the advantage of immobilized enzymes over free-solution reactions will be most important in the pharmaceutical industry where proteolytic fragment "fingerprinting" of recombinant proteins is being used to confirm structure.

Amino Acid Sequence↗

Electrokinetically-driven cation-exchange chromatography of proteins and its comparison with pressure-driven high-performance liquid chromatography.

This paper examines protein ion-exchange behavior in electrokinetically-driven open-tubular chromatography with columns produced by immobilization of poly(aspartic acid) on capillary walls. Retention and selectivity are similar in the electrokinetic elution mode to that observed in HPLC. The separation mechanism was found to depend on the relationship of mobile phase pH to that of protein pI and ionic strength. Column efficiency in the electrokinetic elution mode was found to be 10-100-times higher than in HPLC. The best separations were achieved at intermediate ionic strength and high pH. The great advantage of these low-phase-ratio, high-efficiency open tubular columns is that isocratic separations in the electrokinetic elution mode were equivalent to gradient elution in the HPLC mode. Low phase ratio has the net effect of collapsing the chromatogram into a narrow elution window while the very high efficiency produces the requisite resolution.

Animals↗

Capillary electrochromatography of peptides in a microfabricated system.

Reversed-phase liquid chromatography of tryptic peptides is shown in the capillary electrochromatography mode using microfabricated columns. Although selectivity is different, a mixture of tryptic peptides from ovalbumin appears to be as easily separated in the CEC as HPLC mode. The major difference between a separation in the macrofabricated CEC column and conventional separations in the HPLC mode is that separations are more readily achieved in the isocratic mode in the lower surface area microfabricated CEC columns.

Chromatography, High Pressure Liquid↗

The in vitro displacement of adsorbed model antigens from aluminium-containing adjuvants by interstitial proteins.

Vaccines prepared by adsorbing an antigen onto an aluminium-containing adjuvant are usually administered by intramuscular or subcutaneous injection. The vaccine then comes in contact with interstitial fluid which contains proteins. In vitro displacement studies were performed to determine whether antigens, which are adsorbed to aluminium-containing adjuvants, can be displaced by interstitial proteins. It was found that when previously adsorbed model antigens such as lysozyme or myoglobin were exposed to interstitial proteins such as albumin or fibrinogen that extensive displacement occurred. A factorial study of the displacement of myoglobin from aluminium hydroxide adjuvant by albumin was performed. The displacement occurred rapidly with the majority of the displacement occurring in less than 15 min. Whether the concentration of the adsorbed myoglobin was above or below the adsorptive capacity of the aluminium hydroxide adjuvant affected the amount which could be displaced. Less myoglobin was displaced when the concentration was below the adsorptive capacity. The age of the model vaccine (1, 2 or 7 days) prior to exposure to the interstitial protein did not influence the amount of myoglobin that was displaced. The affinity of model antigens and interstitial proteins for aluminium hydroxide or aluminium phosphate adjuvant was characterized by the adsorption coefficient in the Langmuir equation. In every case studied, the protein having the larger adsorption coefficient was able to displace the protein with the smaller adsorption coefficient.

Adjuvants, Immunologic↗

Metallocenes as cationizing agents in the characterization of polystyrenes and polyethylene glycols by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Very little work has been done on exploring the transition metals as suitable cationizing agents for the analysis of polymers by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF). This paper reports on the characterization of polystyrenes and polyethylene glycols with select metallocenes as cationizing agents. It was found that ferrocene, nickelocene and cobaltocene did indeed cationize the polymer and that, at higher molecular weights, very little if any metal clusters were observed. It was also found that the signal intensity was improved for the higher molecular weight polymers.

Lasers↗