Search PubMed⌕ Search

Biomedical subjects

F E Marchlinski

Publications and source records attributed to F E Marchlinski.

At least 19 recordsLinked to original sources

Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy.

BACKGROUND: Conventional activation mapping is difficult without inducible, stable ventricular tachycardia (VT). METHODS AND RESULTS: We evaluated 16 patients with drug refractory, unimorphic, unmappable VT. Nine patients had ischemic and 7 had nonischemic cardiomyopathy. All patients had implantable defibrillators and had experienced 6 to 55 VT episodes during the month before treatment. Patients underwent bipolar catheter mapping during baseline rhythm. The amount of endocardium with an abnormal electrogram amplitude was estimated using fluoroscopy in 3 patients and a magnetic mapping system (CARTO) in 13 patients. For the magnetic mapping, normal endocardium was defined by an amplitude >1.5 mV; this measurement was based on sinus rhythm maps in 6 patients who did not have structural heart disease. Radiofrequency point lesions extended linearly from the "dense scar," which had a voltage amplitude <0.5 mV, to anatomic boundaries or normal endocardium. To limit radiofrequency applications, 12-lead ECG during VT and pacemapping guided placement of linear lesions. No new antiarrhythmic drug therapy was added. The amount of endocardium demonstrating an abnormal electrogram amplitude ranged from 25 to 127 cm(2). A total of 8 to 87 radiofrequency lesions (mean, 55) produced a median of 4 linear lesions that had an average length of 3.9 cm (range, 1.4 to 9. 4 cm). Twelve patients (75%) have been free of VT during 3 to 36 months of follow-up (median, 8 months); 4 patients had VT episodes at 1, 3, 9, and 13 months, respectively. Only one of these patient had frequent VT. CONCLUSIONS: Radiofrequency linear endocardial lesions extending from the dense scar to the normal myocardium or anatomic boundary seem effective in controlling unmappable VT.

Adult↗

Hybrid therapy for ventricular arrhythmia management.

Optimum arrhythmia management has evolved to couple ICD therapy with catheter ablative and drug therapy to attempt to eliminate or reduce arrhythmia risk. No longer should the clinician approach such therapy as a choice among single alternative strategies only. Optimum patient management includes not only recognition of the indications and benefits of such hybrid therapy but also a complete understanding of potential pitfalls of such therapy.

Anti-Arrhythmia Agents↗

Efficacy and safety of catheter ablation in octogenarians.

OBJECTIVES: To determine whether catheter ablation is safe and effective in patients over the age of 80. BACKGROUND: There is a tendency to withhold invasive therapy in the elderly until it has been proven safe and effective. METHODS: Over a two-year period from February 1, 1996 to February 1, 1998, 695 consecutive patients underwent 744 catheter ablation procedures of supraventricular and ventricular arrhythmias. These patients were divided into three groups based on age: > or =80 years, 60 to 79 years and <60 years. Acute ablation success, using standard criteria and complication rates for these three groups were determined. RESULTS: There were 37 patients > or =80 years, 275 patients 60 to 79 years and 383 patients <60 years old. The overall acute ablation success rate for the entire group was 95% with no difference in rates among the three groups (97%, > or =80 years; 94%, 60-79 years; 95%, <60 years). The percentage of patients undergoing His bundle ablation was greatest in the > or =80-year-old group (43% vs. 19% vs. 2%, p < 0.01), and the percentage of patients undergoing accessory pathway ablation was greatest in the <60-year-old patients (0% vs. 4% vs. 25%, p < 0.01). The overall complication rate for the entire group was 2.6%, and there was only one major/life-threatening complication. There was no difference in complication rates among the groups (0%, > or =80 years; 2.2%, 60 to 79 years; 3.1%, <60 years). Based on the sample size, the 95% confidence interval is 0% to 7.8% for an adverse event in the octogenarian. CONCLUSIONS: Catheter ablative therapy for the arrhythmias attempted in the very elderly appears to be effective with low risk. Ablation results appear to be comparable with those noted in younger patients.

Aged↗

Accuracy of fluoroscopic localization of the Crista terminalis documented by intracardiac echocardiography.

The crista terminalis is an important anatomic target for ablation of atrial arrhythmias. We determined the accuracy of catheter placement guided by fluoroscopy alone when directed to 24 sites along the crista terminalis in 6 patients. The sites selected included the most medial superior, most lateral superior, mid lateral, and most inferolateral sites along the crista terminalis in each patient. These sites were selected because of their recognized importance in sinus node and/or atrial tachycardia ablation and the importance of avoiding caval structures when targeting the most superior and/or inferior right atrium. The position of the catheter tip was documented using a catheter based ultrasound transducer in the right atrium or vena cava. The operator was blinded to the intracardiac echocardiographic (ICE) results until reviewing the images after the procedure in each patient. The catheter tip, guided by fluoroscopy alone, was identified by ICE to be within the right atrium and within 1cm of the crista terminalis at only 10 of the 24 sites (42%). Importantly, when targeting the most superior and inferior sites along the crista terminalis, the catheter tip, guided by fluoroscopy, was noted to be adjacent to the venous junction with the right atrium but actually located in the superior or inferior vena cava at 5 of the 18 such sites. The catheter was positioned appropriately (within 1 cm of the crista and within the right atrium) guided by fluoroscopy alone when targeting 1 of the 12 sites in the first 3 patients versus 9 of 12 sites in the last 3 patients, p<0.05. In conclusion, it appears that using fluoroscopic guidance alone: 1) localization of the crista terminalis is frequently inaccurate and 2) catheter positioning in the superior/inferior vena cava is commonly noted when targeting very superior and inferior sites along the crista terminalis. A learning curve, assisted by review of ICE recordings after each procedure, appears to improve the accuracy of catheter placement by fluoroscopy alone but still does not result in uniform success. ICE appears to facilitate and ensure accurate targeting of specific anatomic sites along the crista terminalis and thus may serve as an important adjunctive imaging technique in electrophysiology.

Adult↗

Sex-specific triggers for right ventricular outflow tract tachycardia.

BACKGROUND: Right ventricular outflow tract tachycardia (RVOT-VT) is a common arrhythmia in young patients without heart disease. The arrhythmia is characterized by repetitive bursts and premature ventricular contractions with a left bundle branch block, inferior-axis QRS morphology, and symptoms of palpitations. Although more frequent in women, sex-specific triggers for symptomatic RVOT-VT have not been identified. METHODS AND RESULTS: We interviewed 34 women and 13 men referred for ablation of RVOT-VT to determine if predictable but sex-specific exacerbations in symptomatic RVOT-VT exist. After a general query asking if there was predictability to what triggered palpitations, we then specifically queried all patients about symptomatic RVOT-VT initiation with exercise, stress, caffeine, fatigue, and, in women only, periods of recognized hormonal flux. The times identified as states of hormonal flux included premenstrual, gestational, perimenopausal, and coincident with the administration of birth control pills. In response to the completed interview, the most common recorded trigger for RVOT-VT in women was recognized states of hormonal flux with 20 (59%) of 34 women responding positively and 14 (41%) of the 34 indicating that states of hormonal flux were the only recognizable triggers. Men were more likely than women to report that their RVOT-VT was predictably triggered by exercise, stress, or caffeine: 12 (92%) of 13 men versus 14 (41%) of 34 women (P <.01). CONCLUSIONS: Triggers for RVOT-VT initiation are sex specific. Women have RVOT-VT initiation with recognized states of hormonal flux. Men more commonly have RVOT-VT initiated by exercise or stress. These data have important implications related to patient education and counseling in the setting of RVOT-VT and may influence the timing of drug treatment and electrophysiologic evaluation in selected patients.

Adult↗

Basket catheter localization of the origin of atrial tachycardia with atypical morphology after atrial flutter ablation.

Atrial activation from a site in the low lateral right atrium will typically proceed in a superior direction. We present a case of a low lateral right atrial tachycardia with a surface electrocardiographic P wave morphology that appeared to have an inferiorly directed axis. The tachycardia occurred 2 years after successful atrial flutter ablation. The use of a multipolar basket catheter allowed confirmation of the focal origin of the tachycardia, permitted its rapid localization, facilitated catheter ablation, and provided clues to atrial activation that helped describe the appearance of the P wave.

Cardiac Catheterization↗

Using intracardiac catheter recordings from the His and proximal coronary sinus to distinguish isthmus conduction block during catheter ablation of type I atrial flutter.

Isthmus conduction block, demonstrated with the use of multipolar catheter recordings, is considered the preferred endpoint for ablation of type I atrial flutter. This study investigated the feasibility of using recordings from the His and coronary sinus (CS) to document isthmus conduction block. Isthmus conduction block was produced with linear radiofrequency (RF) ablation in 27 patients with type I atrial flutter. In 13 patients (group I), RF was delivered until bidirectional isthmus conduction block was demonstrated with multipolar Halo catheter recordings. In 14 patients (group II), RF was delivered during pacing from the lateral isthmus at 600 ms until a reversal in activation of the proximal CS and His occurred. At this point, data from the Halo recordings were reviewed to see if reversal correlated with conduction block; if not, further ablation was performed until block was demonstrated. The initial reversal in His and CS activation during RF energy delivery correlated with isthmus block in only 4 (28.6%) of 14 patients in group II. Additional RF delivery produced isthmus block in the other ten patients resulting in a further increase in the St-CS interval of 35 +/- 20 ms. A His-CS interval of at least -40 ms signified isthmus block with a sensitivity and specificity of 48% and 100%, respectively. Reversal in His-CS activation during pacing from the lateral margin of the isthmus is not specific for the creation of isthmus block. While activation of the proximal CS bipole > 40 ms after activation of the His appears specific for isthmus block, the low sensitivity of this finding limits its clinical use.

Atrial Flutter↗

Use of multisite electroanatomic mapping to facilitate ablation of intra-atrial reentry following the Mustard procedure.

Ablation of intra-atrial reentrant tachycardia following Mustard or Senning procedures has low success rates. The Biosense Carto system was used to map intra-atrial reentry in a 22-year-old woman who had undergone a Mustard procedure. A line of block was created connecting a Mustard baffle suture line to the tricuspid valve annulus, which terminated the arrhythmia and prevented its reinitiation. Multisite electroanatomic mapping was invaluable in defining atrial anatomy and the intra-atrial reentrant pathway, and in creating a contiguous line of block. This mapping may improve ablation success rates in patients following the Mustard or Senning repair.

Adult↗

Concomitant device and drug therapy: current trends, potential benefits, and adverse interactions.

Antiarrhythmic drug therapy in patients with implantable cardioverter defibrillators (ICDs) has decreased over the last 10 years. This trend, primarily seen with class I agents, has occurred mainly in patients with a cardiac arrest. However, despite this overall decrease, antiarrhythmic drug therapy remains an important adjuvant to ICD therapy. In addition to primary prevention of ventricular tachycardia and supraventricular tachycardia, antiarrhythmic drug therapy may potentiate tachycardia rate slowing and make ventricular tachycardia more tolerated hemodynamically and possibly more amendable to pacing therapy. Some of the class III antiarrhythmic drugs may actually lower defibrillation threshold. Unfortunately, these drugs may have adverse interactions with ICDs. An increase in defibrillation threshold or rate-dependent increase in pacing threshold may interfere with the effectiveness of device therapy. Proarrhythmic effects of antiarrhythmic drugs may enhance the frequency of device use. The bradycardic effects of antiarrhythmic drug therapy may similarly enhance the requirements for persistent bradycardia pacing and lead to early battery depletion and other adverse consequences. An awareness of potential benefits and adverse effects of antiarrhythmic drug therapy along with careful electrophysiologic assessment are necessary for optimum combination drug and device therapy.

Amiodarone↗

Electroanatomic left ventricular mapping in the porcine model of healed anterior myocardial infarction. Correlation with intracardiac echocardiography and pathological analysis.

BACKGROUND: Catheter ablation for ventricular tachycardia in healed infarction is limited to patients with inducible, tolerated arrhythmias. Strategies that would allow mapping during sinus rhythm might obviate this limitation. METHODS AND RESULTS: Two sets of experiments were performed in adult pigs to refine a new technique for left ventricular mapping. First, detailed endocardial maps were done in 5 normal pigs and 7 pigs 6 to 10 weeks after left anterior descending coronary artery infarction to characterize electrograms in normal and infarcted tissue by electroanatomic mapping (CARTO, Biosense). Electrogram recording sites were verified by intracardiac echo (ICE, 9 MHz) and grouped by location: infarct (area of akinesis by ICE), border (0.5-cm perimeter of akinetic area), and remote. Compared with remote sites, electrograms from infarct sites had smaller amplitudes (1.2+/-0.5 versus 5.1+/-2.1 mV, P<0.001), longer durations (74.2+/-26.3 versus 36.3+/-6.4 ms, P<0.001), and more frequent notched or late components. Border zone electrograms were intermediate in amplitude and duration. Second, infarct characterization by electroanatomic mapping was compared with pathological (exclusion of triphenyltetrazolium chloride staining) and ICE measurements. Infarct size by pathology correlated with the area defined by contiguous electrograms with amplitude </=1 mV (r=0.98, P=0.0001). Infarct size by ICE imaging correlated with the area defined by contiguous electrograms with amplitude </=2 mV (r=0.95, P=0.0016). CONCLUSIONS: Electroanatomic mapping during sinus rhythm allows accurate 3D characterization of infarct architecture and defines the relationship of electrophysiological and anatomic abnormalities. This technique may prove useful in devising anatomically based strategies for ablation of ventricular tachycardia.

Animals↗

Intracardiac echocardiography (9 MHz) in humans: methods, imaging views and clinical utility.

A new low-frequency (9 MHz, 9 Fr) catheter-based ultrasound (US) transducer has been designed that allows greater depth of cardiac imaging. To demonstrate the imaging capability and clinical utility, intracardiac echocardiography (ICE) using this lower frequency catheter was performed in 56 patients undergoing invasive electrophysiological procedures. Cardiac imaging and monitoring were performed with the catheter transducer placed in the superior vena cava (SVC), right atrium (RA) and/or right ventricle (RV). In all patients, ICE identified distinct endocardial structures with excellent resolution and detail, including the crista terminalis, RA appendage, caval and coronary sinus orifices, fossa ovalis, pulmonary vein orifices, ascending aorta and its root, pulmonary artery, RV and all cardiac valves. The left atrium and ventricle were imaged with the transducer at the limbus fossa ovalis of the interatrial septum and in the RV, respectively. ICE was important in identifying known or unanticipated aberrant anatomy in 11 patients (variant Eustachian valve, atrial septal aneurysm and defect, lipomatous hypertrophy, Ebstein's anomaly, ventricular septal defect, tetralogy of Fallot, transposition of the great arteries, disrupted chordae tendinae and pericardial effusion) or in detecting procedure-related abnormalities (narrowing of SVC-RA junction orifice or pulmonary venous lumen, atrial thrombus, interatrial communication). In patients with inappropriate sinus tachycardia, ICE was the primary ablation catheter-guidance technique for sinus node modification. With ICE monitoring, the evolution of lesion morphology with the three imaging features including swelling, dimpling and crater formation was observed. In all patients, ICE was contributory to the mapping and ablation process by guiding catheters to anatomically distinct sites and/or assessing stability of the electrode-endocardial contact. ICE was also used to successfully guide atrial septal puncture (n = 9) or RA basket catheter placement (n = 4). Thus, ICE with a new 9-MHz catheter-based transducer has better imaging capability with a greater depth. Normal and abnormal cardiac anatomy can be readily identified. ICE proved useful during electrophysiological mapping and ablation procedures for guiding interatrial septal puncture, assessing placement and contact of mapping and ablation catheters, monitoring ablation lesion morphological changes, and instantly diagnosing cardiac complications.

Adult↗

Narrowing of the superior vena cava-right atrium junction during radiofrequency catheter ablation for inappropriate sinus tachycardia: analysis with intracardiac echocardiography.

OBJECTIVES: The study explored the potential for tissue swelling and venous occlusion during radiofrequency (RF) catheter ablation procedures using intracardiac echocardiography (ICE). BACKGROUND: Transient superior vena cava occlusion has been reported following catheter ablation procedures for inappropriate sinus tachycardia (IST). Presumably, venous occlusion could occur owing to thrombus formation or tissue swelling with resultant narrowing of the superior vena cava-right atrial (SVC-RA) junction. METHODS: Intracardiac echocardiography (9 MHz) was used to guide ablation catheter position and for continuous monitoring during RF application in 13 ablation procedures in 10 patients with IST. The SVC-RA junction was measured prior to and following ablation. Successful ablation was marked by abrupt reduction in the sinus rate and a change to a superiorly directed p-wave axis. RESULTS: Eleven of 13 procedures were successful, requiring 29 +/- 20 RF lesions. Prior to the delivery of RF lesions, the SVC-RA junction measured 16.4 +/- 2.9 mm. With RF delivery, local and circumferential swelling was observed, causing progressive reduction in the diameter of the SVC-RA junction to 12.6 +/- 3.3 mm (24% reduction, p = 0.0001). A reduction in SVC-RA orifice diameter of > or = 30% compared to baseline was observed in five patients. CONCLUSIONS: The delivery of multiple RF ablation lesions, often necessary for cure of IST, can cause considerable atrial swelling and resultant narrowing of the SVC-RA junction. Smaller venous structures, such as the coronary sinus and the pulmonary veins, would also be expected to be vulnerable to this complication. Thus, ICE imaging may be helpful in preventing excessive tissue swelling leading to venous occlusion during catheter ablation procedures.

Adult↗

Antidromic reciprocating tachycardia in patients with paraseptal accessory pathways: importance of critical delay in the reentry circuit.

Previous studies in patients with antidromic reciprocating tachycardia (ART) have observed a critical anatomic requirement (> 4 cm) between an antegrade bypass tract limb and a retrograde AV nodal limb. We report two patients with ART utilizing a paraseptal accessory pathway. In both cases, a critical degree of slow conduction within the circuit provides unusual electrophysiologic substrate to overcome the expected anatomical constraints.

Adult↗

Imaging technique and clinical utility for electrophysiologic procedures of lower frequency (9 MHz) intracardiac echocardiography.

Intracardiac echocardiography using a new 9-MHz ultrasound catheter was performed in 30 patients undergoing percutaneous catheter mapping and radiofrequency ablation of a tachyarrhythmia, because the imaging capabilities with this intracardiac echocardiographic catheter permit detailed identification of normal and abnormal cardiac anatomy with improved imaging depth. Intracardiac echocardiography is of significant clinical utility during ablation for guiding interatrial septal puncture, assessing placement and contact of mapping/ablation catheters, monitoring ablation lesion morphologic changes, and diagnosing procedure-related complications.

Adult↗

Interactions between implantable cardioverter-defibrillators and class III agents.

Although implantable cardioverter-defibrillators (ICDs) can successfully terminate ventricular arrhythmias, antiarrhythmic drugs are often required to prevent recurrent events. Class III antiarrhythmic agents have emerged as the safest, most effective, and widely used agents in the 40-70% of ICD patients who require concomitant antiarrhythmic medication. Antiarrhythmic agents can influence the effectiveness of ICDs to terminate arrhythmias through their effect on defibrillation threshold. All class III agents share the ability to prolong ventricular refractoriness and those with "pure" class III activity consistently decrease defibrillation threshold in the normal canine heart model. Sotalol, amiodarone, and bretylium all have other Vaughan Williams class actions that influence their respective effects on defibrillation threshold. Sotalol has been associated with a decrease in defibrillation threshold in both animal and in clinical studies, whereas amiodarone has been associated with variable effects in animal models and an increase in defibrillation threshold in clinical studies. Additionally, antiarrhythmic agents may prolong ventricular tachycardia (VT) cycle length, which may affect the ability to pace terminate or cardiovert VT. Amiodarone has a moderate slowing effect on the VT cycle length. Finally, class III drugs also have proarrhythmic potential that may affect the defibrillator's function. Sotalol can be associated with dose-related torsade de pointes, whereas amiodarone may slow the VT cycle length below the tachycardia detection rate cutoff. In conclusion, class III pharmacotherapy can be safely administered in conjunction with ICD therapy as long as the interaction between these therapeutic modalities is appreciated.

Amiodarone↗

Efficacy of radiofrequency catheter ablation for ventricular tachycardia in healed myocardial infarction.

Radiofrequency catheter ablation has been useful in the treatment of ventricular tachycardia (VT) in selected patients with healed myocardial infarction. Previous studies have demonstrated success rates of 60% to 96% for targeted VT morphologies; however, these studies included patients only after they have had successful mapping procedures and have received radiofrequency lesions. All patients referred for VT ablation from July 1992 to November 1996 were included in this analysis on an intention-to-treat basis. Ninety-five procedures were performed in 66 patients for 77 distinct presentations with tolerated, sustained VT. Fifty-five procedures were successful (58%) and 40 procedures failed. Reasons for procedural failure included failed radiofrequency application despite adequate VT mapping (21 procedures), no tolerated VT induced (12), and aborted procedures due to complications or technical difficulties (7). Fifty-five patients (71%) eventually had a successful VT ablation, although 10 required > 1 procedure. This analysis revealed factors that contribute to failure of VT ablation procedures in addition to inadequate mapping and lesion formation. Procedural difficulties, particularly the inability to induce tolerated VT, frequently prevent successful catheter ablation in patients who present with tolerated, sustained VT.

Aged↗

Clinical presentation and analysis of risk factors for infectious complications of implantable cardioverter-defibrillator implantations at a university medical center.

The objective of this report is to describe the characteristics of patients who develop infections associated with implantable cardioverter-defibrillators (ICDs) implanted with sternotomy and thoracotomy approaches. A retrospective chart review identified all patients who underwent ICD implantation at a university medical center from November 1982 through February 1990. Several patient and procedural variables were compared between infected patients and noninfected patients. One hundred fifty-seven patients underwent 202 ICD generator implantations (45 generator changes), and nine of these patients developed infection (4.5% per implantation and 5.7% per patient). Of the patient variables analyzed, a significant correlation (P < .0001) was made only with a diagnosis of diabetes mellitus: 36% of diabetics versus 3.9% of nondiabetics were infected. The only patient- or procedure-specific variable that was found to correlate with the development of infection was the presence of diabetes mellitus.

Aged↗

Implantable defibrillator diagnostic storage capabilities: evolution, current status, and future utilization.

There has been a rapid and significant evolution in the stored diagnostic information available from implantable cardioverter defibrillators (ICDs). The diagnostic information available in current generation ICDs has greatly enhanced the clinicians' ability to determine the rhythm triggering device therapy as well as to identify potential problems with the ICD system. Furthermore, this information may be useful in identifying triggers of ventricular arrhythmias in patients at high risk for sudden death. The history, evolution, value, and limitations of the stored diagnostic capabilities of implantable defibrillators are discussed.

Arrhythmias, Cardiac↗